|
| 1 | Maintenance of approach road and service road |
| 2 | 3.15:Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means |
| 3 | OD69520/2023-2024:Diamantling and Relaying departmental interlocking tile 80mm or 100mm or nearest sizethickness, minimum strength M30 including providing a layer of 6mm aggregate for 5cmthickness, then laying interlock cobbles in lines and levels as per the directions of thedepartmental officers at site inclusive of all cost & conveyance charges etc. complete |
| 4 | OD69470/2023-2024:Construction of embankment with approved material obtained from borrow pits with allleads and lifts transporting to site spreding grading to required slop and compacting to meet requirement of table300-2 |
| 5 | OD183967/2023-2024:Providing and fixing non woven Geotextile 120 gram per sqm including conveyance andlabour charges etc: complete. |
| 6 | 4.2.A.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-III -For lower sub-base - Mix in Place Method |
| 7 | 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. |
| 8 | 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. |
| 9 | 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. |
| 10 | OD183990/2023-2024: Mix seal Surfacing Providing ,laying and rolling of close - graded premixsurfacing material of 40mm thickness composed of 11.2mm to 0.9 mm Type -Aaggregate using penetration grade bitumen to required line, grade and level to serve aswearing course on previously prepared base, including mixing in a suitable plant,laying and rolling with a three wheel 8-10 KN static roller and finishing to requiredlevel and grades as per Technical specifications clause 509 of MORD (Usage ofbitumen is 44.00 kg/10M2)- BY Manual Means |
| 11 | 55.22:Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete. |
| 12 | 55.23:Supplying and laying interlocking tile 80mm or nearest size thickness, minimum strength M30 including providing a layer of 6mm aggregate for 5cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc. complete. |
| 13 | 12.8.1.C:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical SpecificationsRCC Grade M20 - Using Concrete Mixer - (Without formwork) |
| 14 | 55.10.1:Providing and erecting retro-reflectorised Object Hazard Marker 300mm x 900mm Providing and erecting retro-reflectorised Object Hazard Marker sign with 07 years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick / aluminium composit material sheeting 4 mm thick with suitable back support frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly fixed 30cm above ground level by means of properly designed foundation with M 15 grade cement concrete 30cmx30x45cm, 45cm below ground level including painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as per approved drawing and clause 801.300 mm x 900 mm |
| 15 | 8.15:Supplying and installation of delineator (Roadway indicators) posts 80- 100cm high above ground level, pained black, and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorized panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification) |
| 16 | OD69707/2023-2024:Engaging man mazdoor for cleaning and accumulated earth, wastes etc complete |
| 17 | OD188706/2023-2024:Dry rubble masonry using blasted rubbles including wedging them tightly with chips, allmaterials and labour charges etc complete as directed by departmental officers at site |