Tender For Internal And External Electrification Work., jhansi-Uttar Pradesh

Jhansi Development Authority has published Tender For Internal And External Electrification Work.. Submission Date for this Tender is 27-12-2023. Electrification Work Tenders in jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41164716
Tender For Internal And External Electrification Work.
Open Tender
Indian
Uttar Pradesh
jhansi
27-12-2023

Tender Details

Tender For Internal And External Electrification Work.

Key Value

Document Fees
INR 4720 /-
EMD
INR 537350.0 /-
Tender Value
INR 67.46 Lakhs /-

BOQ Items

Name of Work: Jhansi Nagar Ke Antargat Gram Karari mein Transport Nagar ke liye 50 Shopes hetu Internal and External Electric work.
Sl. No. Item Description
1Name of Work: Jhansi Nagar Ke Antargat Rajasv Gram Karari mein Transport Nagar ke liye 50 Shopes hetu Internal and External Electric work. Note : (1) GST Excluded on the aforesaid work.
2Supplying and fixing of following sizes of medium size PVC conduit along with accessories in surface/recess incluiding cutting the wall and making good the same in case of recessed conduit as requird.SOR.1.21 20mm
3Supplying and drawing follwing sizes of FRLS PVCinsulated copper conductor ,single core cable in the existing surface / recessed steel/ pvc as required. 1x1.5 sq.mm
42x2.5 sq mm
52X4 SQ MM
6wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor ,single core cable in surface /reecessed steel conduit as required.DSR.1.7 2x1.5 sq mm+1x1.5sq.mm earth wire(DSR1.14.1)
72x2.5 sq mm+1x2.5sq.mm earth wire(DSR1.14.2)
82X4 SQ MM+1X4 sq.mm earth wire(DSR1.14.3)
9Wiring for light/power plug with 2x4 sq.mm FRLS insulated coppe conductor core cable in surface / recessed medium class PVC conduit along with 1 nos.4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR.1.12)
10Wiring for light point/fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit ,with modular switch modular plate ,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required .Group C (DSR.1.10.3)
11Supply and fixing of 2/3/4 ways round pvc junction box confirming to ISS for 20mm dia PVC conduit concealed in wall keeping its level upto 20 mm dia PVC conduit concealed in wall keeping its level upto plaster duly provided with proper size cover screwed as directed at site by Engineer in charge with supply of all the material labour and t&p required for proper completion of work.(SOR.154).
12supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc,as required.(DSR.1.27) 3 module
1312 module
14supplying and fixing followingmodular base & cover plate on existing modular metal boxes etc.as required.(DSR.1.28) 3 module
1512 module
16supplying and fixing following modular switch/socket on the existing modular plate & switch box incluiding connections vbut excluiding modular plate etc,as required.(DSR.1.24) 6 A Switch
1716 A Switch
1816 A Socket outlet
19Supplying and fixing hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWG MS sheet incorporating 10mm dia M.S round bar duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid R.C.C roof before concreting along with supply of all.(sor.1149)
20supplying and fixing following modular blanking plate on existing modular plate & switch box excluding modular plate as required.(DSR.1.26)
21Supplying and fixing following way single pole and neutral sheet steel MCB distribution board 24 v on surface / recess,complete with tinned copper bus bar,neutral bus bar ,earth bar ,din bar interconnections powder powder painted incluiding earthing etc,as required.(But without MCB/RCCB/Isolator).(DSR.2.3.4) 12 way, Double door.
22Supplying and fixing rating ,double pole (single phase and neutral) 240 V residual current circuit breaker (RCCB) having a sensitivity current 30 Ma in the existing MCB DB complete with connection testng and commisssioning etc.as required.(DSR.2.14) 25 A
23Supplying and fixing following rating four pole,415V isolator in the existing MCB DB complete with connections,testing and commissioning etc,as required. (DSR2.13.1)
24Supplying and fixing 3 pin 5 A Ceiling rose on the existing junction box/ wooden block incluiding connections etc as required.(DSR.1.31)
25Supplying and fixing two module stepped type electronic fan regulator on the existing modular pate switch box incluiding connections but excluding modular plate.etc as required(DSR.1.25)
26Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD SOR.501 16 sq. mm 4 core(PWD SOR.501.9)
27120 sq. mm 3-1/2 core(PWD SOR.501.15)
28Supply and fixing of plainor pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the EngineerIncharge.(PWD SOR 503) 16 sq. mm
29120 sq. mm
30Supply and fixingof LED Street light Fitting having die cast aluminiumbody and diffuserwith driver set suitable for 110 to 130 Watt. Confirmingto IP 65 and above Protection complete in all respect. CAT-AA(PWD (SOR.1424)
31Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (PWD SOR.14.16) 63 mm Dia (OD-63mm & ID-51 mm Nominal )
32200 mm Dia (OD -200mm & ID -175 mm Nominal)
33Supply & fixingof 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having3mm thiknesswith Double arm bracket (1 Mtr lengtheach ) on RCC foundation includingthe cost of foundation,foundation bolts, excavation& back fillingand Required T&P completee in all respect(PWD SOR 641)
34Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors HRC fuses isolating switch metering instrument & instrumental box with CTs etc,in case of TPN ,complete in all respect. (SOR.807 (b)
35Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the followingHRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switchesfor ammeter and voltmeter,instrumentfuses, current transormer etc. The board shall have suitable capacity electroytic alumininumbusbars as per IS8623 istulatewith heat shrink sleevingand mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compressionglandsand indicatinglamp on incomingetc. The job includesthe grountingof the board as per direction of Engineer-inCharge. All coutgoingswitchesof 100 Amp. and above willbe provided with ampere metre current transformersand selector switches and instrumentfuses etc. The switchesboard shallbe fabricatedwithCRCA sheet with a minimum thicknessof 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only(PWD SOR.801) INCOMIMG 100 Amp TPN 1 Nos (a) Outgoing 63 Amp TPN 2 Nos Cat.B.Cubical Type
36Supplying and making outdoor end termination with cast resin compund including alminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed /xlpe ALMINIUM CONDUCTOR CABLE OF 1.1 kv grade as required.(DSR.9.2) 4X16 sq.mm(DSR 9.2.29)
373X120 sq.mm(DSR 9.2.11)
38Supplying and making straight through joint with cast resin compound incluiding ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR.9.3) 4X16 sq.mm(DSR 9.3.29)
393X120 sq.mm(DSR9.3.11)
40Transformer 11/.433 copper wound capacity 250 KVA complete.(UPPCL cost Data Annexure-28)
41G.I pipe 6 inches dia
42Supply and fixing of steel tubular pole 11 mtr.(UPPCL cost Data Annexure-17)
43Top Channel M.S.100X50X2240
44Cross bracing M.S Angle
45Clamps with Bolt&Nuts
46Barbed wire
47Danger Board with clamp
48Concreting of ST pole
49Earthing complete
50F Bracket
5111 KV Disc insulators B&S type
5211 KV Disc fittings
5311 KV Pin Insulator
5411 KV Pin WITH nut
55P.G clamp
56Stay complete
57concreting of stay
58Paintingof the electricpole with 2 coats of aluminiumpaint over red oxide primercomplete in allrespect.(SOR.634)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail