| 1 | Excavation in soft/disintegrated/weatheredrock including wet excavation, dressing, placing the excavated material neatly inspecified dump area or disposing off the sameas directed, including cost of site clearance, all materials, machinery, labour and dressing etc. Complete. |
| 2 | Excavation in general in soft material comprising of soft soil,soft moorum,sand, hard moorum with boulders in wet or drycondition for head works and allied works by well sinking process for average depth of 12 m and lead of 150m including shoring, barricading, guarding ,refilling, disposing of surplus excavated stuff as directed by Engineer-in-charge , etc. complete.Diameter more than 3M. |
| 3 | Earth work in excavation for foundation, trenches for pipes /cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.Hard rock. Blasting prohibited. |
| 4 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Dewatering and pumping the working area includingall connecting operation required etc. complete. forcleanliness of working area by Measured in terms of electric energy consumed. |
| 6 | Providing and laying M-15 grade Mass Concrete design mix using graded aggregates, clean, hard, including cost of all materials, machinery, labour, formwork, cantering, scaffolding, cleaning, batching, mixing,placing in position, levelling, yibrating, finishing, curing, packing joints of shuttering etc, Complete. 40 mm. |
| 7 | Providing and layitrg M-25 grade Reinforced Cement Cotrcrete design mix using graded aggregate, clean, hard including cost of all materials(excluding cost of pr0viding and placing reinforcement steel/bars ), machinery, labour, formwork, centring, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishitrg, curing, packing joints ofshuttering etc. Cornplete. Using aggregate of maximum size:-20 mm. |
| 8 | Providing, fabricating and placing in position steel reinforcement bars for Reinforced cement concrete / Plain Cement Concrete structures including cost of all materials. machinery. labour, cleaning. straightening, cutting, bending, hooking, lapping / welding joints wherever required, tying with 1.25 mm diameters off annealed steel wire etc. Complete. |
| 9 | Tubular Steel Railing on Medium Weight steel channel (ISMCseries) 100 mm x 50 mm Providing, fixing and erecting 50 mm dia steel pipe (weighing 3.56kg per mts.) railing in 3 rows duly painted on medium weight steelchannels (ISMC series) 100 mm x 50 mm, 1.2 metres high aboveground, 2 m centre to centre, complete as per approved drawings. |
| 10 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required. |
| 11 | Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.150 mm dia. |
| 12 | Providing, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.150 mm dia. |
| 13 | Providing and supplying of cast iron sluice gate square type as per IS 13349 duly tested inclusive of all taxes related to central, state and municipal, inclusive of excise duty, inspection charges, transportation charges, transit insurance, loading/unloading and stacking at site store etc. complete. Sluice gate square type as per IS: 13349, size 500x500 mm, cast iron wall thimble mounted, manually operated CL-PL 5.5 metre, class -1, Flush Bottom closure. |
| 14 | Providing laying, testing and commissioning of \"C\" class heavy duty MS pipe confirming to IS 1239/3589 i/c fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gaskets and welding etc. and fixing the pipe on wall/ceiling with suitable hangers, clamps, supports, as required and painting with two or more coats of synthetic. Enamel paint of required shade complete as directed by Engineering-in-Charge.150 mm dia. |
| 15 | Supplying, fabricating, erectingstructural steel members fabricatedfrom rolled steel sections like channels,angles, beams, rails, plates etc., as per specifications and drawings includingcost of all materials, machinery, labour,scaffolding, cutting, welding, grinding,cleaning, applying two coats ofapproved synthetic enamel paint over acoat of zinc chromate red oxide primerpaint etc., complete with all lead and all lift. |
| 16 | Chain Pully block 3 ton with 15 metre chain |
| 17 | H-Beams 152 X 152 mm., 37.1 Kg./Mtr. |
| 18 | Supply,installation, testing and commissioning of 60 HP submersible High Head dewatering Pump & Control Panel. |
| 19 | Supply and laying of three core 25 sqmm flat copper cable for submersibble pump. |
| 20 | Supply and installation of MCCB 250A 4 Pole for submersible pump. |
| 21 | 12 mm cement plaster of mix :1:4 (1 cement : 4 sand). |
| 22 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 23 | Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. |
| 24 | Painting with synthetic enamel paint ofapproved brand and manufacture to givean even shade: Two or more coats onnew work. |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately).For fixed portion :Powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 26 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).Powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 27 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) :With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ). |
| 28 | Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium. |
| 29 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 30 | Providing and laying non- pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc.complete :300 mm dia. R.C.C. pipe. |
| 31 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-On separate board:-Medium point |
| 32 | Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp |
| 33 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-6 Module PVC box. |
| 34 | Supplying, erection and testing of approved make air circulator fan A.C. 230-250 volts with blades speed regulator etc duly wired with all necessary material complete as required.Air circulator wall mounting fan.600 mm sweep. |
| 35 | Supply and fixing Led tube rod comprising of LED tube with nonintegral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser. |
| 36 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor.Armoured 3 core.10 sq. mm |
| 37 | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required. |
| 38 | Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation in hard rock and refilling the pit with black soil. |
| 39 | Providing and fixing 25mm X 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required. |
| 40 | Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. |
| 41 | Providing and fixing 25mm X 5mm G.I. strip on surface or in recessed for connection etc. as required |
| 42 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) of ISI marked suitable size etc. as required as per specification.2x2.5 Sq.mm. |
| 43 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-Light point/fan points.Primary short point. |
| 44 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-Light point/fan points.Primary medium point. |
| 45 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-Light point/fan points.Primary long point. |
| 46 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-Pin 6 Amp socket outlet on separate board.Medium point. |
| 47 | Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board. |
| 48 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-12 Module PVC box. |
| 49 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.1.5 sq. mm. wire.2 X 1.5 sq. mm. |
| 50 | Fixing of metal clad iron clad enclosure on 25X 5 mm flat iron clamp including supplying and fixing of clamp as required duly embedded in masonry including cable connection and other required material as per specification :-15/16Amp SP/DP switch/SPN, DB up to 4 way. |
| 51 | Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) 2 Wire sub main.2.5 sq. mm. cable. |
| 52 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-MCB SP 6Amp to 32Amp 10kA rating. |
| 53 | Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification.DP (4 module).pole 40Amp, 30mA sensitivity. |