Tripura Industrial Development Corporation Limited-TIDCL has published Tender For Renovation Work Of Conference Hall Including Internal Electrification Maintenance Of Water Supply System And Project Room At Directorate Of Industries And Commerce Govt Of Tripura 2Nd Call. Submission Date for this Tender is 26-12-2023. Electrification Work Tenders in West Tripura Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Dismantling aluminium/ Gypsum partitions, doors,windows, fixed glazing and false ceiling includingdisposal of unserviceable surplus material and stacking of serviceable material with in 50 meterslead as directed by Engineer-in-charge. |
2 | Providing wood work in frames of false ceiling,partitions etc. sawn and put up in position : Local Teak Wood |
3 | Providing and fixing flat pressed 3 layer mediumdensity particle board or graded particle board (Grade I)IS: 3087 marked in ceiling with necessary nails etc.complete (frame work to be paid separately):12 thick |
4 | Providing and fixing curtain rods of 1.25 mm thickchromium plated brass plate, with two chromiumplated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete:25 mm dia. |
5 | Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded builtup standard tubular sections/ appropriate Z sectionsand other sections of approved make conforming toIS: 733 and IS : 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up ofgaps at junctions, i.e. at top, bottom and sides withrequired EPDM rubber/neoprene gasket etc. Aluminiumsections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleatangle, aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as perarchitectural drawing and the directionof Engineer in charge.(Glazing and paneling and dashfasteners to be paid for separately) :- |
6 | For fixed portion of approved quality:-Polyester powder coated aluminium ( minimum thickness of polyester powder coating of 50 micron ). |
7 | For shutters of doors, windows & ventilators includingproviding and fixing hinges / pivots and makingprovision for fixing fittings wherever required includingthe cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately ):- |
8 | Providing and fixing aluminium tubular handle bar of 32mm outer dia, 3.0 mm thick and 2100 mm long withStainless Steel screws etc. of approved quality completeas per direction of Engineer-in-charge:-Polyester powder coated aluminium minimum thickness 50micron. |
9 | Providing and fixing IS : 3564 marked aluminiumextruded section body tubular type universalhydraulic door closer with double speed adjustmentwith necessary accessories and screws etc. complete. |
10 | Providing and fixing aluminium sliding door bolts ISImarked anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc.complete :300x16 m |
11 | Providing and fixing aluminium tower bolts ISImarked anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed torequired colour or shade with necessary screws etc.complete :300x10 mm |
12 | Providing and fixing aluminium hanging floor doorstopper ISI marked anodised (anodic coating not lessthan grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessaryscrews etc. complete. Single rubber stopper |
13 | Providing and fixing aluminium casement stays ISImarked anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc.complete. |
14 | Providing and fixing glazing of approved quality inaluminium doors, windows, ventilator, shutters andpartition etc. with EPDM rubber / neoprene gasket etc.complete as per architectural drawing and the directionof Engineer-in-charge (Cost of snap beading shall be paidin basic item) :- With float glass panes |
15 | Repairs to plaster of thickness 12 mm to 20 mm inpatches of area 2.5 sqm and under including cutting thepatch in proper shape and preparing and plastering thesurface of the walls complete including disposal ofrubbish to the dumping ground with all leads and liftsincluding finishing even and smooth and curing complete as per direction of the Engineer in charge:-13.30.1 With cement mortar 1:3 ( 1 cement : 3 fine sand ). |
16 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
17 | Finishing walls with premium acrylic smooth exterior paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge |
18 | Distempering with oil bound washable distemper ofapproved brand and manufacture and of requiredshade on old work ( one or more coats ), to give an even shade as required complete as per direction of theEngineer in charge. |
19 | French spirit polishing ( one or more coats of gluesizing ) on old work including preparation of surfaceclean, dirt and dust free, sand papered smooth asrequired complete as per direction of the Engineer incharge. |
20 | Providing and fixingfixing ECOCORE pet panels acoustical systems maximum dimention l-2.44m,W-1.22density (+/-10%) 12mm 190kg , composition 100% polyester coreedges squre/bevelled /mitre, fire rating class " A" and class "B" as per astme -B4 tunnel test mounting method glued to the wall with or with out air gap using adhesive (warranty :-warranted against workmanship and manufacturing defects for 2 years from the date of purchase)-.complete as per specification and direction of Engineer-incharge. |
21 | Provoding and fittingfixing in positiondoor and window curtainpoly cotton (material) as per deriction by the Engineer in charge . |
22 | Providing wood work in frames of doors, windows,clerestory windows and other frames, wrought framed and fixed in positionLocal Teak Wood |
23 | Providing and fixing ISI marked flush door shuttersconforming to IS: 2202 (Part I) decorative type, coreof block board construction with frame of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneerson both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
24 | Supplying and Fixing of folllowing Surface/recess mounting LED luminaries in powder coated die cast housing complete with high efficiency diffuser and necessary connection etc.12-18 watt(Round/Square shaped LED Fixture: |
25 | Wiring for light/fan/exhaust fan/call bell point with 2X1.5 sq.mm PVC insulated copper conductor cable (FR) in PVC casing and capping complete with surface modular switch board with cover plate and modular switch including connection etc as required, |
26 | Short Point |
27 | Medium Point |
28 | Long Point |
29 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2X1.5 Sq.mm PVC insulated Copper Conductor Cable (FR) on Surface modular Switch Board,Earthing etc. |
30 | Providing and fixing of 3/6pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2X2.5 Sq.mm PVC insulated Copper Conductor Cable (FR) on Surface modular Switch Board,Earthing etc. |
31 | Wiring Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC Cassing capping etc. |
32 | 2 X 1.5 Sq.mm |
33 | 2 X 4 Sq.mm |
34 | Supplying and fixing of the following sizes modular type cover plates for GI/Plastic modular switch board etc. |
35 | 1-2 module plastic switch board :- |
36 | 12 module plastic switch board :- |
37 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. |
38 | 1-2 module plastic switch board :- |
39 | 12 module plastic switch board :- |
40 | MCB (Single Pole) SP (15Amp) |
41 | MCB (Single Pole) DP (15Amp) |
42 | 250V,6A Switches |
43 | 250V,5Amp,3-Pin Socket |
44 | LED Display Screen 56" inch (Mount type wall) |
45 | Disconnecting damaged overhead/terrace PVC waterstorage tank of any size from water supply line andremoving from the terrace including shifting at groundlevel as per direction of Engineer-in-charge. |
46 | Demolishing brick work including stacking ofserviceable materials and disposal of unserviceablematerials with all lifts and upto a lead of 50m etc.complete as per direction of the Engineer- in-charge:- In cement mortar. |
47 | Dismantling G.I. pipes (external work) includingexcavation and refilling trenches after taking out thepipes, manually/ by mechanical means includingstacking of pipes within 50 metres lead as perdirection of Engineer-in-charge :14.28.1 15 mm to 40 mm nominal bore |
48 | Providing and applying cement slurry on old CC / RCC/ Brick works in joints to receive new and fresh CC /RCC / Brick works including roughening and cleaningthe old surface as required complete as per direction ofthe Engineer in charge. |
49 | Grading roof for water proofing treatment complete asrequired as per direction of the Engineer-in-charge with :17.14.1 Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 gradedstone aggregate 20 mm nominal size) |
50 | Providing and laying APP (Atactic PolypropylenePolymer) modified prefabricated five layer 3 mm thickwater proofing membrane, black finished reinforcedwith non-woven polyester matt consisting of a coat ofbitumen primer for bitumen membrane @ 0.40 litre/sqmby the same membrane manufacture of density at 25°C,0.87-0.89 kg/ litre and viscocity 70-160 cps. Over theprimer coat the layer of membrane shall be laid usingButane Torch and sealing all joints etc, and preparingthe surface complete. The vital physical and chemicalparameters of the membrane shall be as under : Jointstrength in longitudinal and transverse direction at 23°Cas 650/ 450N/5cm. Tear strength in longitudinal andtransverse direction as 300/250N. Softening point ofmembrane not less than 150°C. Cold flexibility shall beupto -2°C when tested in accordance with ASTM, D -5147 as per direction of the Engineer-in-Charge. Thelaying of membrane shall be got done through theauthorised applicator of the manufacturer of membraneas required as per direction of the Engineer-in-charge :17.20.1 3 mm thick |
51 | First class brick work in superstructure above plinthlevel & upto floor-five level including cost of allmaterials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
52 | Half brick masonry work with first class bricks insuperstructure upto floor five level including cost ofall materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
53 | Reinforced cement concrete work in walls (anythickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor fivelevel excluding cost of centring, shuttering, finishing and reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
54 | Reinforced cement concrete work in beams, suspendedfloors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishingand reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
55 | Centering shuttering including struttings, propping etc. and removal of form work for: |
56 | Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
57 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
58 | Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding allcomplete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
59 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
60 | 15 mm cement plaster on the rough side of single orhalf brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
61 | Neat cement punning. |
62 | Repairs to plaster of thickness 12 mm to 20 mm inpatches of area 2.5 sqm and under including cutting thepatch in proper shape and preparing and plastering thesurface of the walls complete including disposal ofrubbish to the dumping ground with all leads and liftsincluding finishing even and smooth and curingcomplete as per direction of the Engineer in charge:-13.30.1 With cement mortar 1:3 ( 1 cement : 3 fine sand ). |
63 | Providing and applying white cement based putty ofaverage thickness 1 mm, of approved brand andmanufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
64 | Distempering with oil bound washable distemper ofapproved brand and manufacture and of requiredshade on old work ( one or more coats ), to give aneven shade as required complete as per direction of theEngineer in charge. |
65 | Finishing walls with acrylic smooth exterior paint ofrequired shade of approved brand and manufacture onold work ( one or more coats ) including preparation ofsurface as required complete as per direction of theEngineer in charge. |
66 | Distempering with oil bound washable distemper ofapproved brand and manufacture to give an even shade[Payment shall be made after submission of TestCertificate issued by the Manufacturer] :12.24.1 New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
67 | Finishing walls with acrylic smooth exterior paint ofrequired shade of approved brand and manufacture [Payment shall be made after submission of TestCertificate issued by the Manufacturer] :12.30.1 New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/10 sqm) |
68 | Providing and fixing G.I. pipes of medim class as perIS : 1239 with latest amendment complete with G.I.fittings including trenching and refilling etc. completeas per CPWD specification and direction of theEngineer - in - charge.External work40 mm dia. nominal bore |
69 | Providing and fixing G.I. Union in existing G.I. pipeline, cutting and threading the pipe and making longscrews including excavation, refilling the earth orcutting of wall and making good the same completewherever required :40 mm nominal bore |
70 | Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded builtup standard tubular sections/ appropriate Z sectionsand other sections of approved make conforming toIS: 733 and IS : 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up ofgaps at junctions, i.e. at top, bottom and sides withrequired EPDM rubber/neoprene gasket etc. Aluminiumsections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleatangle, aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as perarchitectural drawing and the directionof Engineer in charge.(Glazing and paneling and dashfasteners to be paid for separately) |
71 | For fixed portion of approved quality:- Anodised aluminium (anodised transparent or dyed torequired shade according to IS: 1868, Minimum anodiccoating of grade AC 15). |
72 | For shutters of doors, windows & ventilators includingproviding and fixing hinges / pivots and makingprovision for fixing fittings wherever required includingthe cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately ):-Anodised aluminium (anodised transparent or dyed torequired shade according to IS: 1868, Minimum anodiccoating of grade AC 15). |
73 | Providing and fixing aluminium casement windowsfastener of required length for aluminium windows withnecessary screws etc. of approved quality complete asper direction of Engineer-in-charge:-16.11.1 Anodised aluminium of grade AC 15 ). |
74 | Providing and fixing glazing of approved quality inaluminium doors, windows, ventilator, shutters andpartition etc. with EPDM rubber / neoprene gasket etc.complete as per architectural drawing and the directionof Engineer-in-charge (Cost of snap beading shall be paidin basic item) :- With float glass panes With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
75 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 markedwith cover and suitable locking arrangement andmaking necessary holes for inlet, outlet and overflowpipes but without fittings and the base support fortank. |
76 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain &brass threaded fittings including fixing the pipe withclamps at 1.00 m spacing. This includes jointing ofpipes & fittings with one step CPVC solvent cementand testing of joints complete as per direction ofEngineer in Charge. internal work - Exposed on wall 25 mm nominal outer dia .Pipes. metre |
77 | Providing and fixing PTMT Ball cock of approvedquality, colour and make complete with Epoxy coatedrod with L.P./ H.P.H.D. plastic ball. |
78 | 25 mm nominal bore, 152mm long, weighing not less than 440gms |
79 | 40mm nominal bore, 206mm long, weighing not less than 690gms. |
80 | 50 mm nominal bore, 242 mm long, weighing not less than 1240gms. |
81 | Providing, fixing and laying rigid UPVC pipes conforming to IS: 4985 jointing with couplers, of same class conforming to IS :10124 ( Pt-II ) with solvent cement conforming to IS : 14182including testing of joints complete ( but excluding the cost ofspecials like bend, tees etc. which will be paid separately ) asper CPWD specification and direction of the Engineer - in -charge |
82 | 40 mm OD |
83 | 50 mm OD |
84 | Class - 5 ( working pressure 10.0 kg / cm2) 160 mm OD |
85 | Providing, fixing and laying fabricated UPVC bend of requireddegree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 )with solvent cement conforming to IS : 14182 includingtesting of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
86 | 40 mm dia |
87 | 50 mm dia |
88 | 160 mm dia |
89 | Cutting holes upto 30x30 cm in walls includingmaking good the same : With 1st class bricks. |
90 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes (working pressure 4kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion:Single socketed pipe - 110 mm OD |
91 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water pipes conforming to IS : 13592 Type-Aincluding jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion |
92 | Coupler 110 mm |
93 | Single equal tee without door110x110x110mm |
94 | Single equal tee with door 110x110x110mm |
95 | Bend 87.5°110mm |
96 | Providing and fixing unplasticised -PVC pipe clips ofapproved design to unplasticised - PVC rain waterpipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required lengthincluding cutting brick work and fixing with cementmortar 1 : 4 (1cement : 4 fine sand) making good thewall etc. complete.110mm |
97 | Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete.100mm |
98 | Grading roof for water proofing treatment complete asrequired as per direction of the Engineer-in-charge with : 17.14.1 Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
99 | Providing and applying cement slurry on old CC / RCC/ Brick works in joints to receive new and fresh CC / RCC / Brick works including roughening and cleaningthe old surface as required complete as per direction of the Engineer in charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy