Tender For Spl Repair Of Complete Rewiring And Replacement Of Electric Fitting Of All Sec And Replacement Of All Fans In Wksp Floor Bldg No 260 In Zone J At Military Station Agartala, Agartala-Tripura

Military Engineer Services-MES has published Tender For Spl Repair Of Complete Rewiring And Replacement Of Electric Fitting Of All Sec And Replacement Of All Fans In Wksp Floor Bldg No 260 In Zone J At Military Station Agartala. Submission Date for this Tender is 23-01-2024. Electrification Work Tenders in Agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

41122376
Corrigendum : Tender For Spl Repair Of Complete Rewiring And Replacement Of Electric Fitting Of All Sec And Replacement Of All Fans In Wksp Floor Bldg No 260 In Zone J At Military Station Agartala
Open Tender
Indian
Tripura
Agartala
23-01-2024

Tender Details

Tender For Spl Repair Of Complete Rewiring And Replacement Of Electric Fitting Of All Sec And Replacement Of All Fans In Wksp Floor Bldg No 260 In Zone J At Military Station Agartala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Dec-2023 Date Date 15-01-2024
2 05-Jan-2024 BOQ and other BOQ 16-01-2024
3 05-Jan-2024 Date1 Date 16-01-2024
4 16-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 38000.0 /-
Tender Value
INR 19 Lakhs /-

BOQ Items

NAME OF WORK: SPL REPAIR OF COMPLETE REWIRING AND REPLACEMENT OF ELECTRIC FITTING OF ALL SEC AND REPLACEMENT OF ALL FANS IN WKSP FLOOR BLDG NO-260 IN ZONE "J"AT MILITARY STATION AGARTALA.
Sl. No. Item Description
1Taking down celing Fan, carefully of any size from its original position and dismantling kept in safe custody and refixing the fan in same position or at new place including cleaning and reassembling complete all as specified and as directed.
2Taking down carefullyexisting copper/Aluminum point wiring (light,fan,socket or power) complete includingfittings such as switches, ceiling roses, pendents, sockets, boxes, light fitting etc and removing from site and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
3Material and labour for point wiring ,for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuitywire connected to common earth dolly drawn through and including PVC casing and caping of adequate sizewith all accessories and the cables will terminate to Modular Type Pressed Metal Flush Box made out of 2.5mm thick MS Sheet of suitable size duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet top cover for housing Switches, Sockets and Regulators etc. concealed in walls complete all as specified and as directed.
4Material and labour for point wiring ,for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuitywire connected to common earth dolly drawn through and including stove enamelled steel conduit (ISI Mark)with all accessories and the cables will terminate to Modular Type Pressed Metal Flush Box made out of 2.5mm thick MS Sheet of suitable size duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet top cover for housing Switches, Sockets and Regulators etc. concealed in walls complete all as specified and as directed.
5All as per item No 4 above but for 3 pin, 5 Amp Socket outlet on the same board complete all as specified and directed.
6All as per item No 4 above but for 3 pin,5 Amp switch Socket outlet on independent board complete all as specified and directed.
7All as per item no 4 here in before but for power point controlled by one 15 Amp switch on independent boardwith 2.5 sqmmPVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor.
8All as per item no 4 here in before but for power point controlled by one 15 Amp switch on independent boardwith 4.0 sqmmPVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 4.0 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor. Note for Item Nos 3 to 8: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting chases will be carried out by using mechanical means like Groove cutter/ wall chaser. (iii) payment for cutting chases shall deemed to be included in the quote rate.
9Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified and as directed.
10Supply and fixing Switch socket combination3 pin, 5Amp flush type universal complete all as specified and asdirected.
11Supply and fixing Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and asdirected.
12Supply and fixing fan regulator 100/120 watt step type AC 220 volts complete all as specified and as directed.
13Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 65mm x 25mm,ISI marked three terminals complete all as specified and asdirected.
14Supply and fixing LED lights fitting 1x 20W, 220V,with necessary fitting and fixtures including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Note:-Light fitting shall be of PF>0.95.
15Supply & fixing in repairs MCCB 3 pole 415 V, fixed type, 125 Amps with breaking capacity 16 KA complete all as specified and asdirected.
16Supply & fixing in repairs MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and asdirected.
17Supply & fixing in repairs MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and asdirected.
18Supply & fixing in repairs MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and asdirected.
19Supply and fixing 415V 10KA "C" curve miniature circuit breaker (MCB) of triple pole Neutral and current carrying capacity100 Amps in the DB complete with connection testing and commissioning complete all as specified and asdirected.
20Supply and fixing 415V 10KA "C" curve miniature circuit breaker (MCB) of triple pole andNeutral and current carrying capacity 16 to 32 Amps in the DB complete with connection testing and commissioning commissioning complete all as specified and asdirected.
21Supply and fixing 415V 10KA "C" curve miniature circuit breaker (MCB) of triple pole andNeutral and current carrying capacity 25 to 63 Amps in the DB complete with connection testing and commissioning commissioning complete all as specified and asdirected.
22Supply and fixing in repairs amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of single poles and neutral ,current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and asdirected.
23Supply and fixing in repairs amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of single poles,current carrying capacity 5 to 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and asdirected.
24Supply and fixing in repairs single pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB supply of 240 volt 20 Amp,complete all as specified and as directed.
25Supply and fixing in repairs Triple pole and neutral sheet metal enclosure with double door for DBs conforming to IS:8623.III , IP:43 protection, shrouded neutral link and earth bar and cement spill protector, 8 way, 415 Volt . all as specified and directed.
26Supply and fixing in repairs Triple pole and neutral sheet metal enclosure with double door for DBs conforming to IS:8623.III , IP:43 protection, shrouded neutral link and earth bar and cement spill protector, 4 way, 415 Volt . all as specified and directed.
27Supply and fixing in repairs single pole and neutral sheet metal enclosure with double door for DBs conforming to IS:8623.III , IP:43 protection, shrouded neutral link and earth bar and cement spill protector, 8 way, 240 Volt . all as specified and directed.
28Supply and fixing in repairs single pole and neutral sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral link and earth bar and cement spill protector, 4 way, 240 Volt . all as specified and directed.
29Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy dutycable with stranded alluminium conductors 25 sqmm x 4 core,1100 Volt grade, laid in duct/ surface / wall / roof / pole / through pipe , including taking dwn old cable compleate all as specified and as directed
30Supply and fixing sub-main wiring with steel conduit insulated & unsheathed 4 run of 16 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade along with two run of 16 Sqmm PVC insulated and unsheathed copper conductor cable (FRLSH), 1100 Volt grade connected to common earth dolly as earth continuity conductor drawn through steel conduit after and including taking down existing sub main wiring complete all as specified and as directed Note:- 6 Run of 16 Sqmm cable andone run of conduit shall be measured as one unit.
31Supply and fixing sub-main wiring with steel conduit insulated and unsheathed 4 run of 10 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade along with two run of 10 Sqmm PVC insulated andunsheathed copper conductor cable (FRLSH), 1100 Volt grade connected to common earth dolly as earth continuity conductor drawn through steel conduit after and including taking down existing sub main wiring complete all as specified and as directed. Note:- 6 Run of 10 Sqmm cable andone run of conduit shall be measured as one unit.
32Supply and fixing sub-main wiring with steel conduit insulated & unsheathed 4 run of 6 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade along with two run of 6 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade connected to common earth dolly as earth continuity conductor drawn through steel conduit after and including taking down existing sub main wiring complete all as specified and as directed Note:- 6 Run of 6 Sqmm cable andone run of conduit shall be measured as one unit.
33Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completionall as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
34Supply and fixing Earth continuity aluminium strip of 25x3mm earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. For more than 7.5 mtr earth lead from test point, complete all as specified and as directed.
35Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down old unserceable light fitting complete all as specified and as directed. Note:-Light fitting shall be of PF>0.95.
36Taking down exhaust Fan,wall mounted fan,high bay lightcarefully of any size from its original position, kept in safe custody and refixing the fan in same position or at new place including cleaning complete all as specified and as directed.
37Material and Labour for wall mounted Busbar chamber TPN 4 bar 63 Amp rated, 415 volt, 4 way including taking down existingcomplete all as specified and as directed.
38Material and labour for sub main wiring with two single core ,1100 V grade ,PVC insulated cable with Copper conducter unsheathed cable of size 4.0 sqmm drawn through & including PVC Casing -N- capping with 4.0 sqmm PVC insulated copper wire single core for continuous earthing after taking out old unservicable submain wiring complete all as specified and as directed. Note : Two run of 4.0 sqmm and one run of 4.0 sqmm of cable shall be measured as single run.
39Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail