Providing Road Furniture Works To The Four Lane Road Of Ariyalur - Jayankondam Road ( Via ) Sendurai Km2 / 0 - 10 / 0 ( Vpm-122 ) ; 1 Providing And Fixing Reflective Road Stud Of Category A Raised Pavement Markers Made Out Of Poly Corbonite / Methyl Methecrylate / Abs Moulded Body Confirming Toastm D788 And Reflective Panels With Micro Prismatic Lens Capabale Of Provididng Totalinternal Reflection Of The Light Entering The Lens Face With Retro-Reflectance And Chromaticity Values Conforming To Astm D4280. The Reflective Raised Pavement Markers Shall Also Confirm To The Morth Circular No.Rw / Nh33023 / 10 / 97-Do.Iii Dt 11.06.97. The Height, Width And Length Shall Not Be Less Than15mm, 90Mmand 100Mm And With Minimum Reflective Area Of13sq.Cm On Each Side And Slope To The Base Shall Be 35+ / - 5 Degree. Each Reflector Shall Have A Cil Not Less Than Values Specified In Table 2 Of Said Mort&H Circular. The Strength Of Detachment Of The Integrated Cylindrical Shanks ( Of Diameter Not Less Than 19+ / -2Mm And Height Not Less Than 30+ / -2Mm ) From The Body Is To Ba Minimum Value Of 500Kgf. Fixing Will Be By Drilling Holes On The Road For The Shanks To Go Inside, Without Nails And Using Epoxy Resin Based Adhesive As Per ManufacturerS Recommendation And Complete As Directed By The Engineer.The Marker Shall Support A Load Of 13635Kg Tested In Accordance With Astm D4280 And Confirming To Irc 35-2015 Guidelines And Morth Specification 804 Etc.Complete 2 Providing And Erecting Retro Reflectorised Hazard Marker Trafficsignmade Out Of High Intensity Prismatic Grade Sheeting Conforming Totype-Iv Standards Ofirc 67 - 2012 And Astmd 4956 - 09.Specification And Fixed Over 2 Mm Thick Aluminium Sheet Fixed On Back Supporting Frame Mild Steel Angle 25 Mm X 25 Mm X 3 Mm Mild Steel Angle And Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm And 0.60M Below Ground Level.The Sign Post Should Be Painted As Per Irc 67-2012 And Firmly Fixed To The Ground By Measn Of Properly Designed Foundation With M15 Grade Cement Concrete 45Cmx 45Cm X 60Cm Size Including Cost And Conveyance Of All Materials, Equipment, Machinery And Labour With All Leads And Lifts, Loading Charges Necessary For Satisfactory Completion Of The Work As Directed By The Engineer In Charge.High Intensity Retrol Reflectro Sheet Shall Consist Of Minimum Coefficient Of Retro- Reflection As Per Table 6.6 Of Irc 67-2012 The Retro Reflective Sheeting Shall Be Covered Under 7 Year Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67:2012 ( As Per Mort&H Specification No.801 ) 30Cm X 90 Cm Rectangular 3 Providing And Erectingof Retro Reflectorisedcautionary, Mandatory And Informatory Signs ( Without Definition Board ) Made Out Of High Intensity Prismatic Grade Sheeting Conforming Totype-Iv Standards Ofirc 67 - 2012 And Astmd 4956 - 09.Specification And Fixed Over 2 Mm Thick Aluminium Sheet Fixed On Back Supporting Frame Of 25 Mm X 25 Mm X 3 Mm Mild Steel Angle And Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm With A Clear Height Of Not Less Than 2.10M From The Ground Levelto The Bottom Of The Sign Board And 0.60M Below Ground Level.The Sign Post Should Be Painted As Per Irc 67-2012 And Firmly Fixed To The Ground By Means Of Properly Designed Foundation With M15 Grade Cement Concrete 45Cmx 45Cm X 60Cm Size Including Cost And Conveyance Of All Materials, Equipment, Machinery And Labour With All Leads And Lifts, Loading Charges Necessary For Satisfactory Completion Of The Work As Directed By The Engineer In Charge.High Intensity Retrol Reflectro Sheet Shall Consist Of Minimum Coefficient Of Retro- Reflection As Per Table 6.6 Of Irc 67-2012 The Retro Reflective Sheeting Shall Be Covered Under 7 Year Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67:2012 ( As Per Mort&H Specification No.801 ) 60Cm X 45Cm Rectangular 4 Providing And Erecting Direction And Place Identification Of Retro Reflectorised Signmade Out Of Cube Corner Micro Prismatic Grade Sheeting Conforming Totype-Xi Standards Ofirc 67 - 2012 And Astmd 4956 - 09.Specification And Fixed Over 2 Mm Thick Aluminium Sheet Fixed Over A Back Supporting Frame Of 25 Mm X 25 Mm X 3 Mm Mild Steel Angle And Supported On A Mild Steel Angle Post 75 Mm X 75 Mm X 6 Mm With A Clear Height Of Not Less Than 2.10M From The Ground Levelto The Bottom Of The Sign Board And 0.60M Below Ground Level.The Sign Post Should Be Painted As Per Irc 67-2012 And Firmly Fixed To The Ground By Measn Of Properly Designed Foundation With M15 Grade Cement Concrete 45Cmx 45Cm X 60Cm Size Including Cost And Conveyance Of All Materials, Equipment, Machinery And Labour With All Leads And Lifts, Loading Charges Necessary For Satisfactory Completion Of The Work As Directed By The Engineer In Charge.Micro Prismatic Grade Retro Reflectro Sheet Shall Consist Of Minimum Coefficient Of Retro- Reflection As Per Table 6.90 Of Irc 67-2012 The Retro Reflective Sheeting Shall Be Covered Under 10 Year Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67:2012 ( As Per Mort&H Specification No.801 ) ( For Sign Having Area More Than 0.90 Sqm ) .Type-Xi 5 Providing And Erectingof Retro Reflectorisedcautionary, Mandatory And Informatory Signs ( Without Definition Board ) Made Out Of High Intensity Prismatic Grade Sheeting Conforming Totype-Iv Standards Ofirc 67 - 2012 And Astmd 4956 - 09.Specification And Fixed Over 2 Mm Thick Aluminium Sheet Fixed On Back Supporting Frame Of 25 Mm X 25 Mm X 3 Mm Mild Steel Angle And Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm With A Clear Height Of Not Less Than 2.10M From The Ground Levelto The Bottom Of The Sign Board And 0.60M Below Ground Level.The Sign Post Should Be Painted As Per Irc 67-2012 And Firmly Fixed To The Ground By Means Of Properly Designed Foundation With M15 Grade Cement Concrete 45Cmx 45Cm X 60Cm Size Including Cost And Conveyance Of All Materials, Equipment, Machinery And Labour With All Leads And Lifts, Loading Charges Necessary For Satisfactory Completion Of The Work As Directed By The Engineer In Charge.High Intensity Retrol Reflectro Sheet Shall Consist Of Minimum Coefficient Of Retro- Reflection As Per Table 6.6 Of Irc 67-2012 The Retro Reflective Sheeting Shall Be Covered Under 7 Year Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67:2012 ( As Per Mort&H Specification No.801 ) 60 Cm Circular 6 Providing And Erectingof Retro Reflectorisedcautionary, Mandatory And Informatory Signs ( Without Definition Board ) Made Out Of High Intensity Prismatic Grade Sheeting Conforming Totype-Iv Standards Ofirc 67 - 2012 And Astmd 4956 - 09.Specification And Fixed Over 2 Mm Thick Aluminium Sheet Fixed On Back Supporting Frame Of 25 Mm X 25 Mm X 3 Mm Mild Steel Angle And Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm With A Clear Height Of Not Less Than 2.10M From The Ground Levelto The Bottom Of The Sign Board And 0.60M Below Ground Level.The Sign Post Should Be Painted As Per Irc 67-2012 And Firmly Fixed To The Ground By Means Of Properly Designed Foundation With M15 Grade Cement Concrete 45Cmx 45Cm X 60Cm Size Including Cost And Conveyance Of All Materials, Equipment, Machinery And Labour With All Leads And Lifts, Loading Charges Necessary For Satisfactory Completion Of The Work As Directed By The Engineer In Charge.High Intensity Retrol Reflectro Sheet Shall Consist Of Minimum Coefficient Of Retro- Reflection As Per Table 6.6 Of Irc 67-2012 The Retro Reflective Sheeting Shall Be Covered Under 7 Year Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67:2012 ( As Per Mort&H Specification No.801 ) 90Cm Equilateral Triangle 7 Supply And Installation Of Delineators ( Road Way Indicators, Hazard Markers Object Makers ) 80-100 Cm High Above Ground Level, Painted At Alternatively Black And White In 15 Cm Wide Strips, Fitted With 80 X 100Mm Rectangular Or 75Mm Dia Circular Reflectorised Panels At The Top Burned Or Pressed In To The Ground And Conforming To Irc 79 Etc.Complete. ( As Per Mort&H Specification No.806 ) For Delineators 8 Providing And Fixingof Flexible Median Marker That Are Made Of Tough, High Impact Resistant, Injection Molded, Thermoplastic Body With Property Of Flexibility To Provide High Durability.The Dimension Of Flexible Medianmarker Should Not Exceed 18.4Cm In Height ( Including Shank Height ) 12.5Cm In Width, 0.65Cm In Thickness And Shank Depth Shallbe 3.4Cm.The Body Structure Shall Be Rounded At All Its Corners And Edges.The Plastic Used For Molding The Flexible Median Marker Should Survive Impact Load Of 5Kg Continuously For 750 Times At Room Temperature.The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body In The Injection Molding Process.The Median Marker Shall Have Flame Like Shaped Body With, Fluorescent Yellow Color Retro- Reflective Sheeting Of Size Not Less Than 90Cm Square, With Fully Reflective Micro Prismatic Cube Corners As Its Retro Reflective Elements As Per Irc 67-2012 And Astm D4956-09 Type Xi Specfications Reflectivity Values.The Retro - Reflective Sheeting Shall Be One Or Both Sides O The Flexible Median Marker And Shall Be Edge Protected With No Exposed Edges Which Will Prevent Edge Lifting, Vandalism. Sheeting Damage Etc.The Flexible Median Marker Shall Be Fixed By A Combination Of Epoxy Adhesive And Grouting As Recommended By Manufacturer. 9 Providing And Erectingof Retro Reflectorisedcautionary, Mandatory And Informatory Signs ( Without Definition Board ) Made Out Of High Intensity Prismatic Grade Sheeting Conforming Totype-Iv Standards Ofirc 67 - 2012 And Astmd 4956 - 09.Specification And Fixed Over 2 Mm Thick Aluminium Sheet Fixed On Back Supporting Frame Of 25 Mm X 25 Mm X 3 Mm Mild Steel Angle And Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm With A Clear Height Of Not Less Than 2.10M From The Ground Levelto The Bottom Of The Sign Board And 0.60M Below Ground Level.The Sign Post Should Be Painted As Per Irc 67-2012 And Firmly Fixed To The Ground By Means Of Properly Designed Foundation With M15 Grade Cement Concrete 45Cmx 45Cm X 60Cm Size Including Cost And Conveyance Of All Materials, Equipment, Machinery And Labour With All Leads And Lifts, Loading Charges Necessary For Satisfactory Completion Of The Work As Directed By The Engineer In Charge.High Intensity Retrol Reflectro Sheet Shall Consist Of Minimum Coefficient Of Retro- Reflection As Per Table 6.6 Of Irc 67-2012 The Retro Reflective Sheeting Shall Be Covered Under 7 Year Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67:2012 ( As Per Mort&H Specification No.801 ) 60Cm X 60Cm Square 10 Providing And Fixing Of Retro Reflectorized Overhead Cantileverinformatory Sign Madeof Cube Corner Micro Prismatic Grade Sheeting Conformimg To Type Xi Standards Of Irc 67 -2012 And Astm D 4956 - 09 Specification And Fixed Over 2Mm Thick Aluminium Sheet Fixed On Back Supporting Frame Mild Steel L Angle Of Size 50Mmx50mmx 6Mm. The Vertical Support Post For The Installation Of Overhead Sign Gantry Shall Be Made Of 300 Nb ( Nominal Bore ) Ms Pipe With 12Mm Thick With A Ground Clearance Of 6M Along With 80 Nb ( Nominal Bore ) Ms Pipe With 4Mm Thick And 40Nb ( Nominal Bore ) Ms Pipe With 3.20Mm Thick Support Posts. Ms Base Plate Of Size 1200Mm X 1200Mmx 25Mm Andms Top Plates Of Size 900Mmx 1650Mm X 16Mmto Be Used To Hold The Sign Board At The Top And Bottom Respectively.Ms Stiffiener Plates 8Mm Thick Of Sizes 420X420, 682X420, 288X288, 288X927 & 44X 130 Are To Be Used.Anchor Bolts Of Dimension 25Mm Dia And 1000Mm Length Are To Be Used As Fixtures.The Approved Directioninformation Should Be Digitallyprinted And Should Have 70%Of The Co- Efficient Of Retro- Reflection Values Against The Values As Mentioned In Table 6.9 Of Irc 67-2012.The Latex Printer Used For Digital Printing Should Use Inks With Low Voc Emissions And Have Green Guard, Eco Logo Certificates As Per Ul 2801 Standards.The Retro - Reflective Sheeting Shall Be Coveredunder 10 Years Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67-2012 ( Asper Mort&H Specification No.801 ) . Cantilever Sign Shall Be Installed At The Site As Per The Approved Structural And Foundation Drawing Provided In The Tender Document And Including Cost Andconveyance Of All Materials, Euqipment, Machineries To Worksite, Including All Labour Charges For Fixing The Gantry In Position With All Leads And Lift, Loading Charges And Necessary For Satisfactorycompletion Of The Work As Directed By The Engineer In Charge Etc. Complete Digially Printed Retro Reflectorised Overhead Gantryinformation Sign Board. 11 Providing And Erectingof Retro Reflectorisedcautionary, Mandatory And Informatory Signs ( Without Definition Board ) Made Out Of High Intensity Prismatic Grade Sheeting Conforming Totype-Iv Standards Ofirc 67 - 2012 And Astmd 4956 - 09.Specification And Fixed Over 2 Mm Thick Aluminium Sheet Fixed On Back Supporting Frame Of 25 Mm X 25 Mm X 3 Mm Mild Steel Angle And Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm With A Clear Height Of Not Less Than 2.10M From The Ground Levelto The Bottom Of The Sign Board And 0.60M Below Ground Level.The Sign Post Should Be Painted As Per Irc 67-2012 And Firmly Fixed To The Ground By Means Of Properly Designed Foundation With M15 Grade Cement Concrete 45Cmx 45Cm X 60Cm Size Including Cost And Conveyance Of All Materials, Equipment, Machinery And Labour With All Leads And Lifts, Loading Charges Necessary For Satisfactory Completion Of The Work As Directed By The Engineer In Charge.High Intensity Retrol Reflectro Sheet Shall Consist Of Minimum Coefficient Of Retro- Reflection As Per Table 6.6 Of Irc 67-2012 The Retro Reflective Sheeting Shall Be Covered Under 7 Year Warranty Issued For Field Performance And A Certified Copy Of Three Years Outdoor Exposure Report Shall Be Obtained As Per Irc 67:2012 ( As Per Mort&H Specification No.801 ) 90Cm High Otagon 12 Supplying Of Solar Raised Pavement Markers Made Of Polycarbonate Molded Body, Solar Powered, Led Self Illumination In Active Mode, 360 Degreeillumination And Reflective Panels With Micro Prismatic, Lens Capable Of Providing Total Internal Reflection Of The Light Entering The Lens Face In Passive Mode.The Productshall Support A Load Of 13635Kg Tested In Accordance To Morth And Astm D 4280 Type H.The Product Should Be Resistant To Water Ingress According To Ip 65 Standards With Is 12063:1987 Category 2 And Shouldwithstand Temperatures In The Range Of -7 C To 70C.Flashing Rate And Color Of Lighting Is To Be Provided As Per Requirement.There Should Be Minimum Current Losses Of Less Than 20 Micro - Amperesin Sleep - Charging Mode To Enhance Product Life And Single Charge Shouldprovide For A Minimum Autonomy Of 50 Hours.The Height, Width And Length Shallnot Be Less Than 10Mm X 100Mm X 100Mm.Fixing Will Be By Drilling Holes On The Road For The Shanksto Go Inside, Without Nails And Using Epoxy Resin Based Adhesive As Per ManufacturerS Recommendation And Complete As Directed By The Engineer.Warranty Certificate And Testreports Confirming To Compressive Strength As Per Morth Circular Shall Be Obtained From The Manufacturer And Submitted To The Engineer -In- Charge.Two Years Warranty Certificate For Solar Rpmfor The Quantity Installed Anda Certified Copy Of Test Reports From An Independent Test Laboratory Conforming To Water Ingress Shall Be Obtained From Themanufacturer By The Contractor And Submitted To The Engineer - In - Charge ( Two Years Warranty Certificate For Solar Rpm ) 13 Calculation Of Subtotal, Gst And Total Amount Carried Out By System Automatically 14 Basic Cost Of Value Put To Tender As Per Estimate 15 Add Gst At 18% 16 Total Value Put To Tender 17 Difference In Value 18 Bidder Quoted Value 19 Add Gst At 18% Of Final Quoted Value 20 Total Value Of Contract Including 18% Of Gst 21 Basic Cost Of Value Put To Tender As Per Estimate 22 Quoted Rate In Figures ( Total Value Of Contract Including 18% Of Gst )