Repair And Maintenance Of 12 Nos. Of Mini Mast Andhigh Mast Systems At Various Locations In Changanassery Municipality.
Tender Value
7.68 Lakhs
Estimated cost
Bid Submission
21 Dec 2023
0 days left
EMD
19223
Bank guarantee accepted
Document Fee
1814
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
changanassery → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair And Maintenance Of 12 Nos. Of Mini Mast Andhigh Mast Systems At Various Locations In Changanassery Municipality.
BOQ
| Sl. No. | Item Description |
| 1 | Repair and Maintenance of 8 Mtr High Mast Light atvandipetta junction,Ward-33 |
| 2 | od204298/2023_2024 : Supply of 150W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 3 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 4 | Repair and Maintenance of 8 Mtr High Mast Light atinfront of anadhapuram temple,Ward-28 |
| 5 | od204298/2023_2024 : Supply of 150W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 6 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 7 | Repair and Maintenance of 12 Mtr High Mast Light atPalathara, Ward-5 |
| 8 | od204501/2023_2024 : Supply of 200W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 9 | od204547/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 10 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 11 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 12 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 13 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 14 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 15 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. |
| 16 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 17 | od204724/2023_2024 : Charges for KSEB Connection Conversion from LT Three phase to LT Single phase |
| 18 | Repair and Maintenance of 12 Mtr High Mast Light at SH junction,Ward-4 |
| 19 | od204501/2023_2024 : Supply of 200W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 20 | od204547/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 21 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 22 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 23 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 24 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 25 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 26 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. |
| 27 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 28 | od204724/2023_2024 : Charges for KSEB Connection Conversion from LT Three phase to LT Single phase |
| 29 | Repair and Maintenance of 8 Mtr High Mast Light at Pattathimuck, Ward-14 |
| 30 | od204926/2023_2024 : Supply of 100W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 31 | od204945/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 32 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 33 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 34 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 35 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 36 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 37 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 38 | Repair and Maintenance of 12 Mtr High Mast Light at Bakthapriyath Temple, Ward-14 |
| 39 | od204501/2023_2024 : Supply of 200W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 40 | od204945/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 41 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 42 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 43 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 44 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 45 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 46 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. |
| 47 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 48 | Repair and Maintenance of 8 Mtr Mini Mast Light atinfront Vettadi temple, Ward-25 |
| 49 | od204926/2023_2024 : Supply of 100W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 50 | od204945/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 51 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 52 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 53 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 54 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 55 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 56 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. |
| 57 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 58 | Repair and Maintenance of 8 Mtr Mini Mast Light at Assumptions college, Ward-4 |
| 59 | od204298/2023_2024 : Supply of 150W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 60 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 61 | Repair and Maintenance of 8 Mtr Mini Mast Light at Neerchappara, Ward-8 |
| 62 | od204926/2023_2024 : Supply of 100W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 63 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 64 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 65 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 66 | Repair and Maintenance of 8 Mtr Mini Mast Light at Chithra Kulam, Ward-29 |
| 67 | od204926/2023_2024 : Supply of 100W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 68 | od204945/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 69 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 70 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 71 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 72 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 73 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 74 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. |
| 75 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 76 | Repair and Maintenance of 8 Mtr Mini Mast Light at Hidayath, Ward-29 |
| 77 | od204926/2023_2024 : Supply of 100W LED Flood Light output greater than 105lumenM 4000-6000K with lP66 protection LED Chip Make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than 1 0%, power factor greater than 0.98, RoHS compliant duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM79&80 certificates from NAISL accredited Third party lab to be produced mentioning chip manufacturer) |
| 78 | od204945/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 79 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 80 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 81 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 82 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 83 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 84 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. |
| 85 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
| 86 | Repair and Maintenance of 12 Mtr High Mast Light at Iroopa,Ward-17 |
| 87 | od204501/2023_2024 : Supply of 200W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 88 | od204945/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 89 | od206769/2023_2024 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor,Digital timer. |
| 90 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 91 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 92 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 93 | 90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 94 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. |
| 95 | od204718/2023_2024 : Charges for Removal of Faulty light from Existing HM/MM light pole & Installation of Flood lights |
AI Tender Summary
Tender Timeline
Dec 14, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedDec 21, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 22, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender