Tender For Special Repair To Conversion Of Oh Lt Line To Ug Cable At Dronachal Bhopal And Special Repair Replacement Of Unsv Ber Summer Appliances At Dronachal Bhopal, bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Special Repair To Conversion Of Oh Lt Line To Ug Cable At Dronachal Bhopal And Special Repair Replacement Of Unsv Ber Summer Appliances At Dronachal Bhopal. Submission Date for this Tender is 03-01-2024. AMC of Air Condition Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41113488
Corrigendum : Tender For Special Repair To Conversion Of Oh Lt Line To Ug Cable At Dronachal Bhopal And Special Repair Replacement Of Unsv Ber Summer Appliances At Dronachal Bhopal
Open Tender
Indian
Madhya Pradesh
bhopal
03-01-2024

Tender Details

Special Repair To Conversion Of Oh Lt Line To Ug Cable At Dronachal Bhopal And Special Repair Replacement Of Unsv Ber Summer Appliances At Dronachal Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Dec-2023 Corrigendum No. 01 BOQ 03-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 58200.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:SPECIAL REPAIR TO CONVERSION OF OH LT LINE TO UG CABLEAT DRONACHAL AND SPL REPAIR /REPLACEMENT OF UNSV/BER SUMMER APPLIANCES AT DRONACHAL BHOPAL
Sl. No. Item Description
1Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mmmultistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete all as specified and directed with following accessories:-
2INCOMING:- (a) MCCB 400 Amps microprocessor released type 415 Volts,36 KA, 4 pole.-01 No. OUT GOING:- (a) MCCB 160 Amps with adjustable type 4 pole 415 Volts, 16 KA-01 Nos (b) MCCB 100 Amps with adjustable type4 pole 415 Volts, 16 KA-04 Nos (c)MCCB 63 Amps with adjustable type 3 pole 415 Volts, 16 KA-05 Nos (d) Digital type Volt meter 0-500 Voltssquare typewith selector switch- 01 No. (c) Digital type Ammeter 0-400 Amps square typewith selector switch- 01 No. (d)Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set. (f) Cable glands brass of suitable size for cable. Note:- Approval of GE must be obtainedfor Panel design/drawing and CPRI approval of manufacturerbefore placing order.
3Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mmmultistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete all as specified and directed with following accessories:-
4INCOMING:- (a) MCCB 250 Amps microprocessor released type 415 Volts,36 KA, 4 pole.-01 No. OUT GOING:- (a) MCCB 160 Amps with adjustable type 4 pole 415 Volts, 16 KA-03 Nos (b) MCCB 100 Amps with adjustable type4 pole 415 Volts, 16 KA-06 Nos (c)Digital type Volt meter 0-500 Voltssquare typewith selector switch- 01 No. (c) Digital type Ammeter 0-400 Amps square typewith selector switch- 01 No. (d)Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set. (f) Cable glands brass of suitable size for cable. Note:- Approval of Engr-In-Charge must be obtainedfor Panel design/drawing and CPRI approval of manufacturerbefore placing order.
5Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 4 corecomplete all as specified and directed by the Engineer-in-Charge.
6Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core complete all as specified and directed by the Engineer-in-Charge.
7Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by the Engineer-in-Charge.
8Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 3½ core complete all as specified and directed by the Engineer-in-Charge.
9Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core complete all as specified and directed by the Engineer-in-Charge.
10Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and directed by the Engineer-in-Charge.
11Excavation in trench by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and directed by the Engineer-in-Charge.
12M & L for sand cushioning to PVC/XLPE cables with river sand and punning to provide required cover to UG cables, complete all as specified and directed. Note:- For the purpose of payment only punned thickness will be measured.
13Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding25 cm in any type soil.
14Removing excavated surplus soil (hard rock) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by the Engineer-in-Charge
15Sub class "B" old size well burnt brick laid flate in trenches as protection to LT cable complete all as specified and directed by the Engineer-in-Charge.
16Supply and lay for tubes "medium grade " with all galvanised fittings laid in trenches/on ground complete of dia 100 mm.
17Supply and lay for tubes "medium grade " with all galvanised fittings laid in trenches/on ground complete of dia 50 mm.
18Supply and lay for tubes "medium grade " with all galvanised fittings laid in trenches/on ground complete of dia 25 mm.
19Earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25X4 mmas earthing lead covered with 40mm bore GI pipe light gradeby means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20 mm dia GI watering pipe "medium grade", funnel with wire mesh, earthing chamber with cement concrete (1:3:6) type C-1, RCC chamber cover 80 mm thick (1:2:4) type B-1, excavating & earth work all asshown in electrical plate No. 3 of SSR (Part-I) and testing on completion complete all as specified and directed. Note:- Length upto 7.5m of GI strip is inclusive in unit rate.
20Taking down old insulator any type and make - from existing over head line and poles/stay after dismantling electrically complete all as specified and directed by the Engineer-in-Charge.
21Dismantling cross-arms of M.S. channel or angle sections etc. and taking down complete all as specified and directed by the Engineer-in-Charge.
22Dismantling/Taking down old LT, over head line of ACSR from PCC/Steel pole. (Note :-Dismentaling of MS work and insulators shall be removed and paid seperatly)
23Dismantling/Taking down old guard wire and stay wire of galvanised iron wire from LT over head line PCC/Steel pole. (Note :-Dismentaling of MS work and insulatores shall be removed and paid seperatly)
24Supply & fix street lightjunction box of size 300 x200 x105 mm innerdimension made out of FRP sheet with weather proof hinged doors, locking arrangements horizontal / vertical operated with6 amps MCB SP, along with provision of 04 Nos aluminium bus bar of capacity 40 Amps and including 25mm x3mm MS flat iron clamps duly painted with two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed including dismantling of existing unserviceble box.Make of Box Sintex/Hensel orequivalent
25supply & fixweather proof PVC insulated multistranded copper conductor 1.5 Sqmm flat / round, threecore 1100 volts grade complete all as specified and directed.
26Supply, install,testing and commissioningof 5 Star ratedair cooled spilt type airconditionerselectric driven( 250 Volts, single phase, 50 HZ supply)withEnergy efficient Rotary Compressor, working on R-32 or superior enviornment-friendly refrigerant, cordless remote operated, comprising of indoor unit,wall mounted, material of construction of indoor unit ABS, Nominal cooling capacity 4500 KCal/Hr, Minimum Power consumption , Minimum room discharge airflow 700 CuM /Hr Guranteed cooling capacity(Min) 4275 KCal/Hr, outdoor unit, Material of CabinetGI Sheet 1.0 mm thick powder coated,Copper tubing, electric connection (Between indoor and outdoor unit located upto a maximum distance of 10 Meters) andcondensate water drainage arrangement etc complete of capacity 2 Ton complete all as specified and directed at site. Note :- The outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS stand. The cost is deemed to be included in the quoted rates.
27Supply, install,testing and commissioningof 5 Star ratedair cooled spilt type airconditionerselectric driven( 250 Volts, single phase, 50 HZ supply)withEnergy efficient Rotary Compressor, working on R-32 or superior enviornment-friendly refrigerant, cordless remote operated, comprising of indoor unit,wall mounted, material of construction of indoor unit ABS, Nominal cooling capacity 4500 KCal/Hr, Minimum Power consumption , Minimnu room discharge airflow 700 CuM /Hr Guranteed cooling capacity(Min) 4275 KCal/Hr, outdoor unit, Material of CabinetGI Sheet 1.0 mm thick powder coated,Copper tubing, electric connection (Between indoor and outdoor unit located upto a maximum distance of 10 Meters) andcondensate water drainage arrangement etc complete of capacity 1.5 Ton complete all as specified and directed at site. Note :- The outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS stand. The cost is deemed to be included in the quoted rates.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail