Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 100 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Ladda Under Jjm Scheme On Turnkey Basis.- 1 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Ladda ( Stage First ) . 2 9 Mtr. Long St Pole ( St-410 Sp-33 ) 3 Gi V Cross -Arm With Top Bracket Including Clamps 4 Gi Channel X-Arm Including Clamps And Angle For Braces 5 30Mm² Acsr Weasel Conductor 6 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 7 Pg Clamps 8 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 9 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 10 Galvanized Nuts And Bolts 11 Danger Plates With Clamps 12 Anti Climbing Device With Clamps 13 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 14 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 15 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 16 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 17 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Installation Of 100 Kva Substation At Wss Ladda ( Stage-First ) 18 11 / 0.433 Kv, 3-Phase Distribution Transformer 100 Kva With Bimetallic Terminal Connectors Energy Level-2 Aluminiumwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 19 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 20 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 21 11 Kv Horn Gap Fuse Set 3 Phase 200 A 22 185Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 23 9 Mtr. Long St Pole ( St-410 Sp-33 ) 24 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 25 Gi Channel / Angle / Flat Of Sizes Including Clamps 26 Galvanized Nuts And Bolts. 27 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 28 11 Kv Poloymer Composite Pin Insulator, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 29 Lt Distribution Box For 100 Kva Dtr With Mccb For Incomer And SfuS For Outgoing Circuits 30 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 31 Pg Clamps 32 Danger Plates With Clamps 33 Gi Barbed Wire For Anticlimbing 34 3-Phase 4-Wire Prodigy Meter With Box 35 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 36 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 37 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Ladda ( Stage First ) . 38 8 Mtr. Long St Poles ( St-410 Sp15 ) 39 Gi M Clamps For Shackle Insulator 40 30Mm²acsr Weasel Conductor 41 Shackle Insulator 42 Galvanized Nuts And Bolts. 43 Danger Plates With Clamps 44 Anti Climbing Device With Clamps 45 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 46 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 47 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole