Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #41101479

Tender For Construction And Commissioning Of 200 Mm Dia Tubewell Under Division Makrana

Issued by Government Departments · Makrana, Rajasthan
Tender Value
87 Lakhs
Estimated cost
Bid Submission
28 Dec 2023
0 days left
EMD
1.74 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Makrana → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Construction And Commissioning Of 200 Mm Dia Tubewell Under Division Makrana

BOQ

Name of Work: Construction and Commissioning of 08 Nos bore hole by DTH/Rotary/ Combination rig of 200 mm dia, supply and installation of energy efficient Submersible Pump sets, Panels Cables and other allied works including commissioning and testing of tube well under Div. Makrana with 24 months defect liability, 3 years operation and maintenance after completion of defect liability period under sanctioned Revised BSR 2023
Sl. No. Item Description
1Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.
2Nominal bore 200 mm dia.
3Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
4Add 30% extra on above item(Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
5Construction of Tube Well from ground level and upto 100 mtr. depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe.
6Nominal bore 200 mm dia
7Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.
8Nominal bore 200 mm dia.
9Add 15% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
10Add 30% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
11Development of Tube well as per I.S.11189:1985 and IS-2800 (Part-I):1991 (both amended upto date) using suitable compressor to give sand- free water for required yield of the gravel packed TW
12Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS: 8110-2000 or as amended up to date
13200 mm dia nominal bore of 5.4 mm thickness
14Supply of ERW M.S. black casing pipe ISI marked (IS : 4270/2001) or amended upto date of grade Fe 410 of following sizes
15200 mm dia nominal bore of 5.4 mm thickness and mass of tube 28.46 Kg/m)
16Providing & Lowering in tubewell ISI marked GI Pipe \"B\" class as per IS : 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
1750 mm dia
18Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc.
193 core 6.0 mm2
20Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS : 8034-2011 (pump) and IS 9283-2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting& accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect.
219.3 KW (12.5 HP) & head above 120 mtr
22S&F MS clamps set of 50 mm x 6 mm flat form iron with nuts and bolts etc for holding the riser pipe assembly of submersible pumpset
23Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter, over load relya, ampere n meter with CTs, volt meter, phase preventor, suitable starting copacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out form 18 guage MS sheet with powder coating. panel should be of minimum size 900 X 600 x 450 mm with stand (made of angle iron of size 35x35x5m) duly bolted/ screwed with enclosure box having 4 legs, each leg\"s length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC plate form should be equal or bigger thatn the base size of panel having height of at least 200 mm from gound level. The panel should have opening of suitable size in fron of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt AC supply
24Above 10 HP and up to 15 HP
25Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 65 mm dia
26Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.200 MM DIA
27Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.
28Testing verticality of tube well by plumping system and yield test and draw down test by pumping system as per IS : 2800 (Part- II) - 1979 as amended up to date
29Providing and Fixing of ISI marked PVC storage tank of following capacityas per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four nos of superior quality and approved make, including interconnections complete job. (2000 ltr capacity)
30Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 1 0.0 Sq.mm, 4 core
31Maintiance of TWs which includes round the the clock monitoring of TWs of all sizes, complete including cost of material components required to repair pump sets, staters meters etc. of electrict panel of TWs, lowering and unlowreing of pump sets complete in all respect maintiance of log book and histrory sheets as directed by Engiener - in- charge for TW per month. (excluding repairing of Pump sets)
32O&M for Third Year
33O&M for Fourth Year
34O&M for Fifth Year

AI Tender Summary

OUR REF NO 41101479
AUTHORITY Government Departments
TENDER VALUE 87 Lakhs
LAST DATE 28-12-2023
Authority
Authority Name Public Health Engineering Department
Work Description Tender For Construction And Commissioning Of 200 Mm Dia Tubewell Under Division Makrana
Basic Detail
Tender No NIT NO.85/2023-24
Bidding Type Tender
Location
City Makrana
State Rajasthan
Key Dates
Publish Date 14 Dec 2023
Submission Date 28 Dec 2023
Open Date 29 Dec 2023
Finance
Tender Value 87 Lakhs
Tender Fee 2000
EMD 1.74 Lakhs
Exemption Not Available
Document List
6c8a124c-a913-4166-95ec-6cc5aaf26c66.html
BOQ_671703.xls
TECHBID85.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 14, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 28, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 29, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

6c8a124c-a913-4166-95ec-6cc5aaf26c66.html

xls

BOQ_671703.xls

pdf

TECHBID85.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders