Tender For Repair Of Lightning Protection Lightning Conductor Earthing Of Blgs Sub Main Wiring Incl Services Maint Of Solar Water Heater System At Palampur And Alhilal Mil Stn, palampur-Himachal Pradesh

Military Engineer Services-MES has published Tender For Repair Of Lightning Protection Lightning Conductor Earthing Of Blgs Sub Main Wiring Incl Services Maint Of Solar Water Heater System At Palampur And Alhilal Mil Stn. Submission Date for this Tender is 11-01-2024. Electrification Work Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41097336
Corrigendum : Tender For Repair Of Lightning Protection Lightning Conductor Earthing Of Blgs Sub Main Wiring Incl Services Maint Of Solar Water Heater System At Palampur And Alhilal Mil Stn
Open Tender
Indian
Himachal Pradesh
palampur
11-01-2024

Tender Details

Repair Of Lightning Protection Lightning Conductor Earthing Of Blgs Sub Main Wiring Incl Services Maint Of Solar Water Heater System At Palampur And Alhilal Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINT OF LIGHTNING PROTECTION, LIGHTNING CONDUCTOR, EARTHING OF BLDGS, SUB MAIN WIRING INCL SERVICES/MAINT OF SOLAR WATER HEATER SYSTEM AT PALAMPUR & ALHILAL MIL STN
Sl. No. Item Description
1Taking down old unserviceable copper/ aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
2Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all asspecified and directed.
3Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed.
4M&L concealed point wiring for one light point/fan point/bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) singel core FRLSH PVC insulated unsheathed and multi stranded copper conductor cable 1100 volts (ISI marked) drawn through and including PVC conduit 20mm dia (medium grade, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc. including pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 60mm deep, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/socket/regulator etc including provn of 1.5 Sqmm single core FRLSH PVC insulated multi stranded copper conductor wire continous as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceilings/floor etc. by using CM (1:3) complete all as specified and directed. Note: Switches/socket/regulator shall be measured and paid separately under appropriate item of BoQ)
5All as per the description of serial item No 04 here-in-before but one 5 pin socket outlet, 5 amps on the same board complete all as specified and directed
6All as per the description of serial item No 04 here-in-before but one 5 pin socket outlet, 5 amps, independent complete all as specified and directed.
7All as per the description of serial item No 04 here-in-before but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed. Note:- Power circuit shall be done in separate circuit.
8S&F in replacement modular switch 1 way 6 A,1 module, 240 volts ISI marked complete all as specified and directed.
9S&F in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
10S&F in replacement socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
11S&F in replacement modular switch 1 way 16 A,1 module, 240 volts ISI marked complete all as specified and directed.
12S&F in replacement ceiling rose, 3 terminal surface type complete all as specified and directed.
13S&F in replacement angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and directed.
14S&F in replacement ding dong bell musical type AC 230 volt single pole complete all as specified and directed.
15S&F in replacement modular fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed.
16S&F in replacement LED complete fitting including batten LED polycarbonate 1 x 20 watt tuberod, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and specifications complete all as specified and directed. Make:- Crompton/Havells/Bajaj or equivalent make as approved by GE.
17Supply & fixing energy efficient LED light of 10/12 Watt of length - 02 Feet long having minimum 1100-1300 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make:- Cat part No: -LUMILINEPLUSSBS 10WLED865SPCSS of make Havells "or" BN 021 LED10S- 6500 PSU GR S1 of make Philips "or" LDL-10-WW of make Crompton or its equivalent as approved by GE.
18Taking down old burnt out bulk head fitting any type and supply and fix LED bulk head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP66 complete all as specified and directed. Make Crompton/Havells/Bajaj
19M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB"s should be same make.
20M&Ldistribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB"s should be same make.
21S&F in replacement 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
22S&F in replacement SPN 40 Amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
23M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
24S&F in replacement post top lantern LED type 20 watt 230 votls AC outdoor type with decorative post top for 360 degree indirecddt light IP65 protection with impact and corrosion resistent complete with driver and lamp complete all as specified and directed.
25S&F LED flood light fitting 50 watt 230V outdoor type with high pressure die cast aluminium housing and heat resistant complete with dirver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
26S&F LED flood light fitting 70 watt 230V outdoor type with high pressure die cast aluminium housing and heat resistant complete with dirver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
27S&F LED flood light fitting 100 watt 230V outdoor type with high pressure die cast aluminium housing and heat resistant complete with dirver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
28S&F LED flood light fitting 150 watt 230V outdoor type with high pressure die cast aluminium housing and heat resistant complete with dirver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
29S&F LED flood light fitting 200 watt 230V outdoor type with high pressure die cast aluminium housing and heat resistant complete with dirver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
30S&F in replacement LED round bollard light type 7 watt 230 volt AC outdoor type for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
31S&F in replacement LED spike light type 9 watt 230 volts AC outdoor type with impact and corrosion resistant complete all as specified and directed.
32S&F in replacement recess mounted slim LED luminaire with drop down diffuser light of size 2ft x 2ft, 36W 230 volts AC corrosion resistant complete all as specified and directed.
33S&F single pole and neutral enclosure with 1 two pin and earth plug and a socket complete with one single pole MCB, 20 Amp, 240 volts ISI marked complete all as specified and directed.
34S&F in repair air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
35S&F in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
36S&F in repair aluminium strip of size 25x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
37S&F in repairs galvanised iron strip of size 32x6mmburied in ground complete all as specified and directed.
38M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connecting to GI earth wire of size 4mm size by means of bolts, nuts, check nuts and protected by provision of GI medium grade pipe of 15mm bore including provision of 40mm tk cover of RCC (1:2:4) reinforced with XPM (wt no less than 4Kg/sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm dia pipe for watering of suitable length placed on tp edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and excavation and earthwork in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as per plate No. 3 of SSR 2009 Part-I and connecting to earth test point all as specified and directed by Engineer-in-Charge and including testing on completion.
39Note:-(i)RCC pit cover shall be pre-cast of RCC (1:2:4) type B1, 80mm thick reinforcement with 8mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii)Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe up to 7.50m and the rate includes in the unit rate of item. (iii)Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and the rate includese in the unit rate of item. (iv)The earth chamber shall be constructed 5m away from the edge of the bldg pit and the cost of the same is deemed to be included in the rate for this item.
40Disconnecting & opening of solar water heater storage type of capacity 100 ltr, descaling with chemical and pressure pump, change the unserviceable parts, re-assembling the same, testing complete all as specified and directed. Note:- All defective or unserviceable spare parts change during servicing shall be measured and paid separately as supply only.
41Disconnecting & opening of solar water heater storage type of capacity 200 ltr, descaling with chemical and pressure pump, change the unserviceable parts, re-assembling the same, testing complete all as specified and directed. Note:- All defective or unserviceable spare parts change during servicing shall be measured and paid separately as supply only.
42S&F in replacement rubber flange of 25mm dia with nut, bolt and washer for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
43S&F in replacement brass flange of 25mm dia with nut, bolt and washer for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
44S&F in replacement copper pipe of existing size and length for collector of solar water heater of 100 to 400 litre capacity complete all as specified and directed.
45S&F in replacement nitrate insulation sleeve for solar water heater as per site requirement of 100 to 400 litre capacity complete all as specified and directed.
46S&F PVC insulation tape and aluminium filing tape for one solar water heater including taking down old unserviceable insulation tape and aluminium filing tape for one solar water heater of 100 to 400 litre capacity complete all as specified and directed.
47S&F in replacement heating element 3 Kw of existing make for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
48S&F in replacement thermostat 0 to 80 degree 11" long of existing make for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
49S&F in replacement of heat exchanger of existing size and make for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
50S&F in replacement of rubber hose pipe (as per existing make and size) for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
51S&F in replacement of flange gasket (as per sample) for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
52S&F in replacement heat collector strip (as per existing make and size) for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
53S&F in replacement tank mixture valve (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
54S&F soldering to copper pipe to rectify the leakage in solar water heater complete all as specified and directed.
55S&F in replacement tubing collector (as per existing make and size) for solar water heater of 100 to 400 litre capacity complete all as specified and directed.
56S&F in repairs tuffen glass of heat collector for solar water heater 100 to 400 litre capacity complete all as specified and directed.
57M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sq mm for phase and neutral and one run of 4.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
58S&F light fitting pre wired suitable for single T8 LED tube along with fitting of nominal wattage-18 watt, Lumen output- 2100 Lm, colour temp- 6500 Kelvin, size & length- G13/T8/4 Feet, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.00076 complete all as specified and directed.
59S&F in repairs surface mounting 2 ft length, 10 watt LED batten with light fitting complete all as specified and directed.
60S&F in repairs 4ft length ultra bright 20W LED polycarbonate tube rod with THD<10% with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders (single side connection) complete all as specified and directed. Make: Havells Cart Part No. PHOTONULTRA2.01213T8SSTL20WLED865SPC or equivalent in Crompton Greaves /Bajaj/Philips/Wipro as approved by GE.
61M&L complete testing and servicing of solar water heater system any type (flat plate collector/evacuated tube collector type) of 200/300/100 ltr per day (LPD) capaciyt complete checking of hot and cold water line, cleaning of deposited impurities, testing of heating element, cleaning and flushing out solar panel, arresting leakage in the system, replacing hot water hose pipe & PUF insulation of pipe, painting the solar panel frame and hot water storage tank frame with two coats of synthetic enamel paint complete all as specified and directed. Note: Rate quoted is deemed to be included for solar ssytem installed atroof top at a a height upto and including 20 mtr from normal ground level.
62Taking down hot water storage tank and transporting to work shop for repair and taking back after repair, cutting the copper tubing, removing the scale from the tubes by drilling/using wire mesh etc. and brazing, arresting leakages etc. refixing in the same position and testing etc. of capacity upto 400 LPD complete all as specified and directed.
63M&L de-scaling, cleaning of hot water tanks including heat collector, pipes etc with suitable agents incl mixing of anti freezing agent of solar heating system of capacity 400 LPD complete all as specified and directed.
64Supply and laying 20mm bore hot water pipe "medium grade", ISI marked, galvanized, with all fittings like socket, union, elbow, bend, tees etc and threading, cutting etc duly insulated with glass wool and aluminium cladding, jointed and laid in trenches or floors fixed to walls/roofs etc, complete including taking down old pipe line complete all as specified and directed.
65S&F in replacement hose pipe including threads clamps at both ends of suitable length as required on site suitable upto 32mm bore GI pipe including nut bolts as required on site complete all as specified and directed.
66S&F in replacement toughened sun glass collector, 4mm thickness or as per existing suitable size for 200/300/400 ltr capacity solwar water heater panel complete all as specified and directed.
67S&F in repair flat plate solar collector including brazing of leaked copper tubes complete all as specified and directed.
68S&F in replacement cladding on existing pipe by replacing with insulation rockwool 2" thick, aluminium sheet of 26 gauge and steel screws as per existing complete all as specified and directed.
69S&F in repairs decorative wall light fixture made up of polycarbnate suitable for 9 watt retrofit LED lamp B 22 Base including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting complete fitting and accessories complete all as specified and directed.
70S&F motor of exhaust fan (plastic body) capacity 200mm as in repair including taking down old unsv motore complete all as specified and directed.
71S&F motor of exhaust fan (plastic body) capacity 250mm as in repair including taking down old unsv motore complete all as specified and directed.
72S&F in repairs electronic meter temper proof LCD display with polycarbonate cover 230V, 10-60A, accuracy class-I 50 Hz, conforming ot IS 13779, IP-54, with parameters to show data, time, current rading, load, PF, voltage and KWH complete all as specified and directed.
73Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
74Returning filling in including spreading leveling watering and well ramming inlayers not exceeding 25 cm in any type of soil complete all as specified and directed.
75Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
76M&L sand cushioning to undergound cable with using fine river sand and gently punning for cushioning to cable complete all as specified and as directed. Note:-for the purpose of payment only punned thickness will be measured.
77S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
78M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equalto length of the brickcomplete all as specified and as directed.
79Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 16 sq.mm 4 coreincluding taking out old unserviceable cable complete all as directed by Engineer-in-charge.
80Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 4 coreincluding taking out old unserviceable cable complete all as directed by Engineer-in-charge.
81Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 16 sq.mm 2 coreincluding taking out old unserviceable cable complete all as directed by Engineer-in-charge.
82Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 2 coreincluding taking out old unserviceable cable complete all as directed by Engineer-in-charge.