Public Health Engineering Department-PHED has published Drilling Of Bore Hole By Dth & Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube Well At Rural And Urban Scheme Of Division M. Submission Date for this Tender is 28-12-2023. Drilling Work Tenders in malpura Rajasthan. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Constructionoftubewellfromgroundlevel& upto 100mtrdepthto accommodatehousingandassemblypipeoffollowingsizesinalltypeof alluviumstrata unconsolidatedformationsuchaspebbles,bouldersetc.by percussion/rotary drilling method as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it"s packing as per IS: 2800 (Part I & II) 1979 as amended uptodate(theworkincludesthecostofgravel&it"sprimarypackingand packingduringdevelopment,loweringofhousing&strainerassemblypipes withsupplyandwrappingofcoir-rope,wherevernecessaryforarrestingfine sandparticlesanddevelopmentwork,butexcludingthecostofhousingand strainerpipeassembly).Theworkwouldbecompletedafterobtainingsand free water. |
2 | Nominal bore 200 mm dia. |
3 | Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and up to 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. |
4 | Add 40% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 200 mtr, rate shall be applicable for only extra depth beyond 200 mtr . |
5 | ConstructionofTubeWellfromgroundlevelandupto100mtr.depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drillingmethod asperIS:2800Part1:1991and IS:2800PartII:1979(both amended up todate) andtechnical specificationsfor removalofoverburden. The work includes the cost oflowering of casing pipe, but excludes the cost of casingpipe. |
6 | Nominal bore 200 mm dia. |
7 | Add 15% extra on above item(Item No 2.2.1 to 2.2.2) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr . |
8 | Constructionoftubewellaftercompletionofdrillingbyrotary/percussion method&upto100mtr.depth inalltypeofrocksbyDTHsystem asper IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technicalspecifications.Thework shallbedeemedcompletedonlyafter obtainingsandfreewater.Theborewellshouldhaveathroughoutnominal size bore beyond casing pipe. |
9 | Nominal bore 200 mm dia. |
10 | Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. |
11 | Add 30% extra on above item(Item No 2.3.1 to 2.3.3) for drilling depth beyond 200mtrandfromgroundlevel,rateshallbeapplicableforonlyextradepth beyond 200 mtr . |
12 | Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling, where strata iscollapsibleandloweringofcasingpipeisrequired.Theworkincludes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only. |
13 | ConstructionofTubeWellupto100mtr.depth inalltypeofrocksbyDTH system&overburdentoaccommodatecasingpipeoffollowingsizesinall typesofsoils&overburdenincludingloweringofcasingpipes,(ifrequired) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would becompletedafterobtainingsandfreewater.Thetubewellshouldhavea through out bore as per nominal dia of casing pipe. |
14 | Nominal bore 200 mm dia. |
15 | Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. |
16 | Add 30% extra on above item(Item No 2.4.1 to 2.4.2) for drilling depth beyond 200mtrandfromgroundlevel,rateshallbeapplicableforonlyextradepth beyond 200 mtr . |
17 | Add 15% extra on above item (Item No 2.4.1 to 2.4.4) for drilling, where strata iscollapsibleandloweringofcasingpipeisrequired.Theworkincludes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only. |
18 | Constructionoftubewellfromgroundlevelandupto100mtr.depthand above of following sizes in all types of soils in alluvium strata, unconsolidated formationsuchaspebbles,bouldersetc.by"bailing"methodandwithout gravelpackingasperIS:2800Part1:1991and IS:2800PartII:1979(both amended up to date) and technical specifications. The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering of casing pipe but excluding cost of the casing pipe. The tube well should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water. |
19 | Nominal bore 200 mm dia. |
20 | Constructionoftubewellfromgroundlevelandupto100mtrdepthand abovetoaccommodatehousingassemblypipeinalltypeofunconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended uptodate)andtechnicalspecifications.Theworkwillincludeloweringof housing andstrainerpipeassemblyandcasingshoeincludingcostofcasing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water. |
21 | Nominal bore 200 mm dia. |
22 | Add 15% extra on above item (Item No 2.6.1 to 2.6.3) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr . |
23 | Testingverticalityoftubewellbyplumbingsystemandyieldtestanddraw downtestbypumpingsystemasperIS:2800(Part–II)–1979orasper amended up to date. |
24 | Supplying & PackingP-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date. |
25 | Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well. |
26 | Supply of ERWM.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes |
27 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) |
28 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. |
29 | 200 mm dia nominal bore of 5.4mm thickness |
30 | Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casingpipeforsubmersiblecableexternalwork40mmdiacompleteinall respect. |
31 | Supply&Installationof3phaseISImarkedsubmersiblemotorpumpsetof three star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283- 2013(motor)orasamendeduptodateofapprovedmakeoffollowing duty conditionwithrequiredaccessoriesincludingmakingconnectionsuitablefor tubewell/DCB.Thejobincludesloweringof motorpump,installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect. |
32 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
33 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
34 | 7.5 KW (10 HP) & head up to 120 mtr. |
35 | 7.5 KW (10 HP) & head above 120 mtr. |
36 | 9.3 KW (12.5 HP) & head up to 120 mtr. |
37 | 9.3KW (12.5 HP) & head above 120 mtr. |
38 | 11 KW (15 HP) & head up to 120 mtr. |
39 | 11 KW (15 HP) & head above 120 mtr. |
40 | 13 KW (17.5 HP) & head up to 120 mtr. |
41 | 13 KW (17.5 HP) & head above 120 mtr. |
42 | 15 KW (20 HP) and above, head up to 120 mtr. |
43 | 15 KW (20 HP) and above, head above 120 mtr. |
44 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
45 | Centrifugal Monoblock Pump set (Single Stage) |
46 | 2.2 KW (3.0 HP) |
47 | 3.7 KW (5.0 HP) |
48 | 5.5 KW (7.5 HP) |
49 | 7.5 KW (10 HP) |
50 | 9.3 KW (12.5 HP) |
51 | 11.0 KW (15 HP) |
52 | 15.0 KW (20.0 HP) |
53 | 18.5 KW (25.0 HP) |
54 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approvedmakeandthepanelenclosureshouldbemadeoutfrom18gauge M.S.Sheetwithpowdercoating.PanelsizeHeight600mmWidth500mm depth250mmwithStand(madeofangleironofsize35x35x5mm)duly bolted/screwedwithenclosureboxhaving4legs,eachleg’slength18"and double door including in built locking system.The legs should be embedded in M-15cementconcreteplatform.ThesizeofCCplatformshouldbeequalor biggerthanthebasesizeofpanelhavingheightofatleast200mmfrom groundlevel.Theoperationofpanelshouldbesuitableforon240VoltAC Supply. |
55 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. completesuitable forthree phase pumpset.Thepanel shouldhavespaceforenergy meter( suppliedby DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600x300mmwithStand(madeofangleironofsize35x35x5mm)duly bolted/screwedwithenclosureboxhaving4legs,eachleg’slength18"and double door including in built locking system.The legs should be embedded in M-15cementconcreteplatform.ThesizeofCCplatformshouldbeequalor biggerthanthebasesizeofpanelhavingheightofatleast200mmfrom ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation ofpanel should be suitable for on 440 Volt AC Supply. |
56 | Up to 5.00 HP |
57 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lightingarrangementetc.completesuitableforthreephasepumpset.The panelshouldhavespaceforenergymeter(suppliedbyDISCOM). Allthese equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel shouldbe of minimumsize900 x600 x450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meterreading.Theoperationofpanelshouldbesuitableforon440VoltAC Supply. |
58 | Above 5 HP and up to 10 HP |
59 | Above 10 HP and up to 15 HP |
60 | Above 15 HP and up to 20 HP |
61 | Above 20 HP and up to 30 HP |
62 | DOL STARTER 5.5 KW (7.5HP)- : For 2 motors (1 W+ 1S)I/C -MCB 40A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G-MCB 25A ,TP, 10 KA, C Curve (2), Power Cont 12A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2) |
63 | SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. |
64 | STAR DELTA STARTER 7.5 KW (10.0 HP)- : For 2 motors(1 W+ 1S) I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G-MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2) |
65 | STAR DELTA STARTER 9.3 KW (12.5 HP)- : For 2 motors (1 W+ 1S) I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G-MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2) |
66 | STAR DELTA STARTER 11.0 KW (15.0 HP)- :For 2 motors (1 W+ 1S) I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G-MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) |
67 | STAR DELTA STARTER15.0 KW (20.0 HP) :For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G-MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) |
68 | Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
69 | 3 core 4.0 Sq.mm |
70 | 3 core 6.0 Sq.mm |
71 | Supply&FixingXLPEinsulated/P.V.C.sheathedcableof1.1KVgradewith aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground asperIS:1255includingexcavationof30cmx75cmsizetrench,25cmthick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
72 | 10.0 Sq.mm, 4 core |
73 | Plate Earthingas per IS:3043 with G.I. Earth plate ofsize 600mmx 600mmx 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete withalternatelayersofsaltandcoke/charcoal,testingofearthresistanceas required. |
74 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
75 | Supply & Fixingtube well coverofMS sheet 8mmthick attop &5mmthick 100mmwideshroudaroundtheedgesoastoformacaponthe topend of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre ofMS sheet. A25 mmsocket with end plug shall also be welded over top plate. A GI nipple having outside thread ofsize 1/2" (for installation pressure gauge) shall be provided &welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
76 | 200 mm dia |
77 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), SteeltubeasperIS:1239oramendeduptodateandzinccoatingasperIS 4736,threadedanddoubleflanged(welded)onbothendsandtwonumber 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
78 | 32 mm dia |
79 | 50 mm dia |
80 | 65 mm dia |
81 | 80mm dia |
82 | Providing,installing,testingandcommissioningofdoubleflangedbulkflow meterwithremovablemechanism,ofclassBconformingtoISO4064/1or amendeduptodateofapprovedmakeincludingcostofallmaterialand labouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. |
83 | 50 mm dia |
84 | Providing and Fixing of ISI marked PVC storage tank of following capacityas per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four no"s of superior quality and approved make, including interconnections complete job. |
85 | 1000 litres capacity |
86 | 2000 litres capacity |
87 | Providing&Fixingpumpsafetycageasperspecificationsorasdirectedby Engineer in charge. |
88 | Fabrication & Fixing M.S.Stand of specified class of angle iron L-shaped of 50 mmsizewithfourlegsgroutedby300*300*300mmCCBlockM-15inthe groundandalllegstiedupwitheachotherthroughsamesizeofangleiron along with cross bars to support the bottomof1000 Ltr./ 2000 Ltr.PVC tank complete in all respect. |
89 | Providing&Fixingofdoubleflanged,CIbody,ISImarkedNRVofapproved make of following sizes |
90 | 65 mm dia |
91 | 80 mm dia |
92 | ProvingandFixing32mmdiaFullwayvalveorwheelvalveas perIS:778 or amended up to date of approved make, on pump delivery pipe. |
93 | Supplying&Installing100mmdiametersealeddiaphragmbourdontype pressuregaugeofrange0to10kg. includingalljointingmaterialasper specification with safety cover. |
94 | Constructionofboreholeforshallowdepthtubewellfromgroundlevelto required depth for following size for all type of relevant strata by percussion/ rotarydrilling/handboringmethodexcludingcostofcasingpipe.The bore holeshouldbeaspernominalboreofPVCcasingpipe.Theworkwillbe complete after obtaining sand free water. |
95 | 200 mm dia nominal bore |