Himachal Pradesh State Electricity Board-HPSEB has published Tender For Supply Including Transportation And Insurance Of Equipment/Devices To Be Used In Starter Panel Of 3X42mw Larji Hydro Power Plant, Thalout Distt Mandi (Hp. Submission Date for this Tender is 21-12-2023. Fuses Tenders in Mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply including transportation and insurance of equipment/devices to be used in starter Panel of 3x42MW Larji hydro power plant, Thalout Distt Mandi (HP) |
2 | MCCB 415V, TriplePole 100A, Short circuit rating 35KA complete with thermal release setting, extended terminals and extended rotary handle of make L&T, Schneider, Havells, C&S, ABB only. |
3 | Fuse switch unit, 415 V AC, Triple Pole, 63 A, complete with 32 A with fuse links of make L&T, Schneider, Havells, C&S, ABB only. |
4 | Fuse switch unit, 415 V AC, Triple Pole, 32 A, complete with 10A with fuse links of make L&T, Schneider, Havells, C&S, ABB only. |
5 | Air Break Contactor415V, 3 phase, 110A, 3NO main and 2 NO+2NC Aux Contacts, Coil Voltage 110 V AC of make L&T, Schneider, Havells, C&S only. |
6 | Air Break Contactor415V, 3 phase, 16A, 3NO main and 2 NO+2NC Aux Contacts, Coil Voltage 110 V AC of make L&T, Schneider, Havells, C&S only. |
7 | Air Break Contactor415V, 3 phase, 65 A, 3NO main and 2 NO+2NC Aux Contacts, Coil Voltage 110 V AC of make L&T, Schneider, Havells, C&S,ABB only. |
8 | Air Break Contactor415V, 3 phase,45 A, 3NO main and 2 NO+2NC Aux Contacts, Coil Voltage 110 V AC of make L&T, Schneider, Havells, C&S,ABB only. |
9 | Air Break Contactor415V, 3 phase, 32 A, 3NO main and 2 NO+2NC Aux Contacts, Coil Voltage 110 V AC of make L&T, Schneider, Havells, C&S , ABB only. |
10 | Auxiliary contactor 110 V AC coil voltage, 4 NO+4NC contacts of make L&T, Schneider, Havells, C&S,ABB only. |
11 | Thermal Overload relay 415V, 3 phase 45-75A of make L&T, Schneider, Havells, C&S , ABB only. |
12 | Thermal Overload relay 415V, 3 phase 3-5A, 1 C/Ocontact of make L&T, Schneider, Havells, C&S,ABB only. |
13 | Thermal Overload relay 415V, 3 phase 20-33, 1 C/Ocontact of make L&T, Schneider, Havells, C&S,ABB only. |
14 | Thermal Overload relay 415V, 3 phase 9-15A, 1 C/Ocontact of make L&T, Schneider, Havells, C&S ,ABB only. |
15 | Thermal Overload relay 415V, 3 phase 14-23 A, 1 C/Ocontact of make L&T, Schneider, Havells, C&S,ABB only. |
16 | Thermal Overload relay 415V, 3 phase 30-50 A, 1 C/Ocontact of make L&T, Schneider, Havells, C&S ,ABB only. |
17 | Auxiliary relay, 415 V, 2 Element each with 1NO+1NC, self reset contacts, Reverse Flag of make Alstom VAA ,Series.,ABB, L&T. |
18 | Auxiliary Contactor, 415V AC, Coil Voltage 415V, 4NO+4NC contacts of make L&T, Schneider, Havells, C&S,ABB only. |
19 | Push Button, 110 V AC, 1NO+1NC, Red-49, Green-49 of make L&T, Schneider, Havells, C&S only. |
20 | Control Circuit Transformer 415/110V, Single Phase, 300 VA epoxy cast resin type of make Pragati Electrical, Kalpa or equivalent |
21 | Duty Selector Switch, 4 position, 4 ways, Stay put type of make L&T or equivalent. |
22 | Indicating Lamps 110V AC, LED Type, Complete with fittings, Red-51 and Green-51 of Make Binay electronics, Siemens, L&T. |
23 | Current Transformer single phase, CT-100/5A, 5VA, Bar primary type, Accuracy-1.5 of make AE, Meco or equivalent |
24 | Current Transformer single phase, CT-50/5A, 5VA, Bar primary type, Accuracy-1.5 of make AE, Meco.Or equivalent. |
25 | Ammeter 0-100A, Moving Iron type, 100/5A, CTR 5VA, 96x96 sq. mm Flush Mounting, Accuracy 1.5 of make AE, Meco, Havells or equivalent. |
26 | Ammeter 0-50 A, Moving Iron type, 50/5A, CTR 5VA, 96x96 sq. mm Flush Mounting, Accuracy 1.5 of make AE, Meco, Havells or equivalent. |
27 | Control circuit fuse 2A, complete with fuse pullar and base of of make Havells, L&T or equivalent |
28 | Panel ilumination fuse 5A, complete with fuse pullar and base of make Havells, L&T, anchor. |
29 | Illumination Lamp, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, 5 Watt, 220V AC of make Havells, Anchor, crompton. |
30 | On/Off switch, 240V AC Single pole, 5A, Piano type, flush mounting of make Havells, Anchor, crompton. |
31 | 3 pin socket, 5A, 240V AC, Flush Mounting of make Havells, Anchor, crompton. |
32 | Panel Heater 80 Watt, 240V of make L&T or equivalent |
33 | Thermostat 240V AC, 0-85° C, 1 Aux contact of make L&T, Havells, C&S. |
34 | Single phase preventer/ phase failure relay 415 V AC of make minilec, L&T, Havells only |
35 | Terminal Block 5 Amp, 6mm thickness (Pack of 50) |
36 | Bus Bar type terminal Block of rating 1000V, 200A, flexible wire size 35-95 sq.mm din rail mount type |
37 | Non insulated ring type copper thimbles of size 2.5 mm² |
38 | Non insulated ring type copper thimbles of size 10 mm² |
39 | Non insulated ring type copper thimbles of size 25 mm² |
40 | Non insulated ring type copper thimbles of size 50 mm² |
41 | Non insulated ring type copper thimbles of size 70 mm². |
42 | Non insulated ring type copper thimbles of size 120 mm². |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy