Tender For Renovation Of Rttc Building (Gf) For Renting Out To Office Of The Sr. Registrar, Mp Govt At Indore, indore-Madhya Pradesh

Bharat Sanchar Nigam Limited-BSNL has published Tender For Renovation Of Rttc Building (Gf) For Renting Out To Office Of The Sr. Registrar, Mp Govt At Indore. Submission Date for this Tender is 23-12-2023. Kitchen Equipment Tenders in indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41090088
Tender For Renovation Of Rttc Building (Gf) For Renting Out To Office Of The Sr. Registrar, Mp Govt At Indore
Open Tender
Indian
Madhya Pradesh
indore
23-12-2023

Tender Details

Tender For Renovation Of Rttc Building ( Gf ) For Renting Out To Office Of The Sr. Registrar, Mp Govt At Indore ; 1 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. ( A ) All Kinds Of Soil. 2 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 3 Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation / Banking Excavated Or Stacked Materials. ( A ) All Kinds Of Soil. 4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : ( A ) 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 5 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : ( A ) 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 6 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Sizederived From Natural Sources ) . 7 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : ( A ) Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 8 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : ( A ) Suspended Floors, Roofs, Landings, Balconies And Access Platform 9 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. ( A ) Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 10 Smooth Finishing Of The Exposed Surface Of R.C.C. Work With 6 Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) . 11 Brick Work With Common Burnt Clay M.K.S. Modular Bricks Of Class Designation 3.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : ( A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 12 Half Brick Masonry With Common Burnt Clay M.K.S. Modular Bricks Of Class Designation 3.5 In Superstructure Above Plinth Level Up To Floor V Level. ( A ) Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 13 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry.Ird Course Of Half Brick Masonry. 14 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. ( A ) Granite Stone Slab All Colour And Texture Except Black, Cherry / Ruby Red ( I ) Area Of Slab Over 0.50 Sqm 15 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approvedmake, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 16 Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete 17 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., ., Complete. 18 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08%And Conforming To Is : 15622 , Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. ( A ) Size Of Tile 600X600 Mm 19 Providing And Fixing Tiled False Ceiling Of Specified Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc.Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. ( A ) 12.5 Mm Thick Fully Perforated Gypsum Board Tile Made From Plasterboard Having Glass Fibre Conforming To Is: 2095 Part I , Of Size 595X595 Mm, Having Perforation Of 9.7X9.7 Mm At 19.4 Mm C / C With Center Borders Of 48 Mm And The Side Borders Of 30 Mm, Backed With Non Woven Tissue On The Back Side, Having An Nrc ( Noise Reduction Coefficient ) Of 0.79, With 50 Mm Resin Bonded Glass Wool Backing. 20 12 Mm Cement Plaster Of Mix : ( A ) 1:6 ( 1 Cement: 6 Coarse Sand ) 21 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix : ( A ) 1:6 ( 1 Cement: 6 Coarse Sand ) 22 Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per ManufacturerS Specification. ( A ) Two Or More Coats On New Work. 23 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : ( A ) Two Or More Coats On New Work. 24 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 25 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type ) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : ( A ) W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 26 Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps ( All In C.P. Brass ) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Wherever Required : ( A ) Range Of Two Half Stall Urinals With 5 Litre P.V.C. Automatic Flushing Cistern 27 Providing And Fixing One Piece Construction White Vitreous China Squatting Plate With An Integral Longitudinal Flushing Pipe, White P.V.C. Automatic Flushing Cistern, With Fittings, Standard Size G.I. / Pvc Flush Pipe For Back And Front Flush With Standard Spreader Pipes With Fittings, G.I Clamps And C.P. Brass Coupling Complete, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Etc. Wherever Required : ( A ) Single Squatting Plate With 5 Litre P.V.C. Automatic Flushing Cistern 28 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: ( A ) White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 29 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : ( A ) Kitchen Sink With Drain Board ( I ) 510X1040 Mm Bowl Depth 250 Mm. 30 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. ( A ) Flexible Pipe ( I ) 32 Mm Dia 31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 32 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. :Concealed Work, Including Cutting Chases And Making Good The Walls Etc. ( A ) 15 Mm Nominal Outer Dia .Pipes. 33 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. :Concealed Work, Including Cutting Chases And Making Good The Walls Etc. ( A ) 20 Mm Nominal Outer Dia .Pipes. 34 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. :Concealed Work, Including Cutting Chases And Making Good The Walls Etc. ( A ) 25 Mm Nominal Outer Dia .Pipes. 35 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge : External Work ( A ) 25 Mm Nominal Outer Dia. Pipes. 36 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : ( A ) 45 Cm Length ( I ) 15 Mm Nominal Bore 37 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. ( A ) 15 Mm Nominal Bore 38 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 : ( A ) 15 Mm Nominal Bore. 39 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. 40 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. ( A ) Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) 41 Repair To Plaster Of Thickness 12Mm To 20 Mm In Patches Of Area 2.5 Sqm And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing Plastering The Wall Surface With White Cement Based Polymer Modified Self Curing Mortar, Including Disposal Of Rubbish, All Complete As Per The Direction Of Engineer-In- Charge. 42 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. ( A ) 110 Mm Diameter 43 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Single Tee Without Door ( A ) 110X110x110 Mm 44 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Bend 87.5° ( A ) 110 Mm Bend 45 Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. 46 Providing And Laying Cement Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design : ( A ) 100 Mm Diameter S.W. Pipe 47 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top Slab With 1:1.5:3 Mix ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : ( A ) Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) : ( I ) With Common Burnt Clay M.K.S.Modular Bricks Of Class Designation 3.5 48 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design : ( A ) 100X100 Mm Size P Type ( I ) With Common Burnt Clay M.P.S. ( Non Kmodular ) Bricks Of Class Designation 3.5 49 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : ( A ) 25 Mm Thick. 50 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 51 Cutting Holes Of Required Size In Brick Masonry Wall For Fixing Of Exhaust Fan Including Providing And Fixing 300 Mm Dia Pvc Pipe Conforming Bis-12818 And Making Good The Same Etc. Complete As Per Direction Of Engineer-In-Charge. 52 Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials I / C Malba All Complete As Per Directions Of Engineer-In- Charge. 53 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. ( A ) In Cement Mortar 54 Taking Out Doors, Windows And Clerestory Window Shutters ( Steel Or Wood ) Including Stacking Within 50 Metres Lead: ( A ) Of Area 3 Sq. Metres And Below 55 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. ( A ) For Thickness Of Tiles 10 Mm To 25 Mm 56 Dismantling By Dismembering Al. Partitionwork With Particle Board / Prelaminated Particle Board / Glass Panelling, From The Existing Position , And Shifting The Material To New Location ( With In Indore Ssa ) . 57 Making Al. Partitionwork Withavailablealuminium Sections, Beadings / Prelaminated Particle Board / Glass Panelling , Grill, And Fixing In Position To Required Size And Shapewith Necessary Screws, Cleats Etc. Wherever Required All Complete As Per Directions Of The Engineer In Charge. ( The Rate Includes All The Materials And Labour Required In Operation And Completion Of Execution Ofthe Item And Nothing Extra Shall Be Payable. )

Key Value

Document Fees
INR 590 /-
EMD
INR 48650.0 /-
Tender Value
INR 24.32 Lakhs /-

BOQ Items

Name of Work : Renovation of RTTC building (GF) for renting out to office of the Sr. Registrar, MP Govt at Indore
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) all kinds of soil.
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
3Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. (a) all kinds of soil.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : (a) 1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
5Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : (a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
6Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources).
7Centering and shuttering including strutting, propping etc. and removal of form for : (a) Foundations, footings, bases of columns, etc. for mass concrete
8Centering and shuttering including strutting, propping etc. and removal of form for : (a) Suspended floors, roofs, landings, balconies and access platform
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
11Brick work with common burnt clay M.K.S. modular bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (a) Cement mortar 1:6 (1 cement : 6 coarse sand)
12Half brick masonry with common burnt clay M.K.S. modular bricks of class designation 3.5 in superstructure above plinth level up to floor V level. (a) Cement mortar 1:4 (1 cement :4 coarse sand)
13Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry.
14Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.(a) Granite stone slab all colour and texture except black, Cherry/ Ruby red (i)area of slab over 0.50 sqm
15Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
16Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
17Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
18Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (a) Size of Tile 600x600 mm
19Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.(a) 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I ,of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
2012 mm cement plaster of mix : (a) 1:6 (1 cement: 6 coarse sand)
2115 mm cement plaster on rough side of single or half brick wall of mix : (a) 1:6 (1 cement: 6 coarse sand)
22Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. (a) Two or more coats on new work.
23Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work.
24Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
25Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (a) W.C. pan with ISI marked white solid plastic seat and lid
26Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : (a) Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
27Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : (a)Single squatting plate with 5 litre P.V.C. automatic flushing cistern
28Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:(a)White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
29Providing and fixing Stainless Steel a ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :(a) Kitchen sink with drain board (i)510x1040 mm bowl depth 250 mm.
30Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (a)Flexible pipe (i) 32 mm dia
31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
32Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. (a) 15 mm nominal outer dia .Pipes.
33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. (a) 20 mm nominal outer dia .Pipes.
34Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. (a) 25 mm nominal outer dia .Pipes.
35Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work (a) 25 mm nominal outer dia. Pipes.
36Providing and fixing uplasticised PVC connection pipe with brass unions : (a) 45 cm length (i) 15 mm nominal bore
37Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (a) 15 mm nominal bore
38Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : (a) 15 mm nominal bore.
39Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
40Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
41Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge.
42Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type a, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. (a) 110 mm diameter
43Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type a including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. (i) Single tee without door (a) 110x110x110 mm
44Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type a including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. (i) Bend 87.5° (a) 110 mm bend
45Providing and fixing 100 mm sand cast Iron grating for gully trap.
46Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : (a) 100 mm diameter S.W. pipe
47Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : (a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :(i) With common burnt clay M.K.S.Modular bricks of class designation 3.5
48Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : (a) 100x100 mm size P type (i) With common burnt clay M.P.S. (non Kmodular) bricks of class designation 3.5
49Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (a) 25 mm thick.
50Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
51Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
52Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
53Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (a) In cement mortar
54Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: (a) Of area 3 sq. metres and below
55Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. (a) For thickness of tiles 10 mm to 25 mm
56Dismantling by dismembering al. partitionwork with particle board /prelaminated particle board/ glass panelling, from the existing position , and shifting the material to new location (with in Indore SSa).
57Making al. partitionwork withavailablealuminium sections, Beadings / prelaminated particle board/ glass panelling , Grill,and fixing in position to required size and shapewith necessary screws, cleats etc. wherever required all complete as per directions of the Engineer in Charge. ( The rate includes all the materials and labour required in operation and completion of execution ofthe item and nothing extra shall be payable.)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail