Tender For Erection (Work Contract) Items, Electrical Works, Ghaziabad-Uttar Pradesh

Uttar Pradesh Rajkiya Nirman Nigam Limited has published Tender For Erection (Work Contract) Items, Electrical Works. Submission Date for this Tender is 18-12-2023. XLPE Cable Tenders in Ghaziabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41078076
Tender For Erection (Work Contract) Items, Electrical Works
Open Tender
Indian
Uttar Pradesh
Ghaziabad
18-12-2023

Tender Details

Tender For Erection ( Work Contract ) Items, Electrical Works - Laying Of 3 Core Standered Aluminium Conductor Xlpe ( Cross Linked Polyethylene ) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S. 7098 ( Part-Ii With Latest Amendments ) Ii Kv Grade At A Depth Of 900 Mm Below Ground Level Over A Cushion Of 100 Mm Thick Fine River Sand All Around And Protected With Well Burnt Bricks On Sides And On Top Put Across. The Armouring Of Cable Shall Be Properly Connected With Earth Conductor By Clamps Etc 70 Sq. Mm 3 Core 3 Making Outdoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required: 70 Sq. Mm 4 Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. 120 Mm Dia ( 00-120 Mm & 10-103 Mm Nominal ) 5 Erection Of 11 Kv Pin Insulator Complete With Large Steel Head G.I. Pin, Nuts, Washers Etc. As Required. 6 Erection Of 11 Kv Disc Insulator For 11 Kv Over Head Lines With Galvanised Insulator Fittings, Ball And Socket Type And Complete With Galvanised Strain Clamps, Bolts, Nuts, Washers Etc. As Required 7 Erection Of Steel Tubular Pole 11 M Long Designated Complete In Aal Respect @ 8% 8 Making Straight Through Cable Jointing With Heat Shrinkable Jointing Kit Complete With All Accessories Including Ferrules Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required: 70 Sq. Mm 9 Erection Of 11 Kv Tpmo @ 8% 10 Erection Of 11 Kv Fuse Set @ 8% 11 Painting Of The Electric Pole With 2 Coats Of Aluminium Paint Over Red Oxide Primer Complete In All Respect. 12 Fixing Danger Board Fabricated From 10 Gauge M.S. Sheet As Per I.E. Rules. 13 Erection Of Overhead Line With Acsr Conductor On Poles / Service Bracket Including Binding Etc. Complete In All Respects 14 Itc Of 63 Kva Transformer 11 / 0.4 Kv @ 8% 15 Earthing With G. I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Reauired. 16 Fixing Of Earthing Of Pole By Ms Earthing Rod Of 20X2500 Mm And 6 Swg Earthing Wire Etc @ 8% 17 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2. 7 Metre Iona Etc. With Charcoal / Coke And Salt As Reauired 18 Laying 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Sorina Washer Spaced At 50Mml 19 Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required 20 Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Reguired 21 Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required 22 Fixing Of Light Class G.I. Pipe Of 100 Mm Dia. ( Nominal ) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. 23 Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Metres In Width, And Lift Upto 1.5 Metres, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Metres. 24 Laying Of 200Mm Dia 6Mm Thicknessthroughtrenchless Method Including Jointing Of Pipe, Excavation Of Thrust Pit And Receiving Pit Of Required Size, Cutting And Repairing Of Roadwith All T & P And The Gps Report Submitted By The Tenderer Before Excavation & Back Filling With Compaction Complete As Per Specification By H.D.D Machine Method. Pipe Will Be Installed At Minimum Depth 2M To 3M Below The Ground Surface Or Downward As Per Site Condition In Required Slope. 25 Llaying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. 50 Sq. Mm 3-1 / 2 Core 26 Making Outdoor End Termination With Cast Resin Compound Including Aluminium Lugs And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed I Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 3-1 / 2 X 50Sq. Mm

Key Value

Document Fees
INR 23600 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: ERECTION (WORK CONTRACT) ITEMS
Sl. No. Item Description
1ERECTION
2Laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc 70 sq. mm 3 core
3Making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 70 sq. mm
4Laying of following size DWC HDPE pipe ISi marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (00-120 mm & 10-103 mm nominal)
5Erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
6Erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
7Erection of Steel Tubular Pole 11 M long designated complete in aal respect @ 8%
8Making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 70 sq. mm
9Erection of 11 KV TPMO @ 8%
10Erection of 11 KV fuse set @ 8%
11Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect.
12Fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules.
13Erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects
14ITC of 63 KVA transformer 11/0.4 KV @ 8%
15Earthing with G. I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as reauired.
16Fixing of Earthing of pole by MS earthing rod of 20X2500 mm and 6 SWG earthing wire etc @ 8%
17Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 metre Iona etc. with charcoal/ coke and salt as reauired
18Laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & sorina washer spaced at 50mml
19Fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required
20Fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as reguired
21Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
22Fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
23Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
24Laying of 200mm dia 6mm thicknessthroughtrenchless method including jointing of pipe,excavation of thrust pit and receiving pit of required size, cutting and repairing of roadwith all T & P and the GPS report submitted by the tenderer before excavation & back filling with compaction complete as per specification by H.D.D machine method. Pipe will be installed at minimum depth 2M to 3M below the ground surface or downward as per site condition in required slope.
25Llaying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 50 sq. mm 3-1/2 core
26Making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 KV grade as required. 3-1/2 X 50sq. Mm