Kerala State Electricity Board-KSEB has published Tender For Supply Installation Testing Commissioning And Maintenance For 5 Years Of Network Actives Passives Networking And Ups Cabling In Op Area In Main Op Block Medical College Kottayam Under Ehealth Project. Submission Date for this Tender is 02-01-2024. Electrification Work Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Outdoor O. F. Cable 6core SM |
2 | 6 Port Fully loaded LIU Rack mountable |
3 | 12 Port Fully loaded LIU Rack mountable |
4 | LC to SC Patch cord. SM |
5 | LC to LC Patch cord. SM |
6 | Cat6 4 Pair UTP Cable: 23 AWG |
7 | Cat6 Information outlet |
8 | Face plate Singlex.- Cat6 |
9 | 3 x 3 Surface mount box for Cat6 Outlet |
10 | Cat6 patch cord,3 mtr |
11 | Cat6 patch cord, 1 mtr |
12 | Cat6 patch panel 24 port Fully Loaded |
13 | 12U Wall mount Rack with Accessories |
14 | 9U Wall mount Rack with Accessories |
15 | Supply of 25mm ISI PVC Conduit- Ivory |
16 | Supply of 32 mm HDPE Pipe |
17 | Fully Managed 24 Port Network Switch with minimum 4* 1/10G SFP+ Uplink with 5 year 24X7 support pack |
18 | 10G SFP Module for Access Switches (SM) |
19 | Supply of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 4 X 16 Sq.mm , 415 V |
20 | Supply of all materials for termination of the following PVC insulated Armored Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 4 X 16 Sq.mm , 415 V |
21 | Supply of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 2 X 16 Sq.mm , 415 V |
22 | Supply of all materials for termination of the following PVC insulated Armored Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 2 X 16 Sq.mm , 415 V |
23 | Supply of 4 way double door MCCB VDB |
24 | Supply of 40A 4P MCCB |
25 | Supply of 40 A 4P MCB |
26 | Supply of 4 way SP DB |
27 | Supply of 16 way SP DB |
28 | Supply of 12 way SP DB |
29 | Supply of 8 way SP DB |
30 | Supply of 2 Pole Isolator 40A |
31 | Supply of 2 Pole ELCB 40A 100ma Leakage |
32 | Supply of 1 Pole MCB 40A |
33 | Supply of 1 Pole MCB 16A |
34 | Supply of 1 Pole MCB 6A |
35 | Supply of6 sq. mm andPVC insulated Copper Wire |
36 | Supply of 2 nos of 2.5 sq. mm and 1 nos of 1.5 sq. mm PVC insulated Copper Wire |
37 | Supply of 2 X 10 SWG Bare Copper |
38 | Supply of 3 nos 6A socket controlled by 2 switch |
39 | Supply of 2 nos 6A socket controlled by 2 switch |
40 | Supply of 1 nos of 16A socket controlled by 1 switch |
41 | Supply of 1 nos of 6A socket controlled by 1 switch |
42 | Supply of 20 mm PVC Conduit accessories |
43 | Supply of All materials for Plate(Galvanized Iron) Earthing as per IS-3043-1987 |
44 | Supply of GI/Cu earthing conductors inclusive of providing earthing terminations and bracing of the terminations using necessary clamps, screws and bolts, PVC sleeves, etc. 25x6 Cu strip |
45 | Supply of Exhaust Fan - 12" |
46 | DLP Trunking 100 x 80 |
47 | DLP Trunking 50 x 50 |
48 | FIXING OF DLP 100 x 80 |
49 | FIXING OF DLP 50 x 50 |
50 | Laying of OF Cable through PVC Conduit/ HDPE Pipe |
51 | Splicing of OFC |
52 | Termination of LIU |
53 | Laying of 4 Pair UTP Cable Cat6 /STP |
54 | Fixing and termination of Information outlet with SMB- Cat6 |
55 | Fixing and port termination of patch panel- Cat 6 |
56 | Fixing & Dressing of wall mount Rack |
57 | Laying of 25 mm PVC Conduit |
58 | Laying of 32 mm HDPE pipe |
59 | Laying of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 4 X 16 Sq.mm , 415 V |
60 | Termination of all materials and termination of the following PVC insulated Armored Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 4 X 16 Sq.mm , 415 V |
61 | Laying of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays / pipes/ etc. including supply and fixing of necessary clamping materials. 2 X 16 Sq.mm , 415 V |
62 | Termination of all materials and termination of the following PVC insulated Armored Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size, Al-Cu strip for termination of cables etc. 2 X 16 Sq.mm , 415 V |
63 | Fixing of 4 way double door MCCB VDB |
64 | Fixing of 40A 4P MCCB |
65 | Fixing of 40 A 4P MCB |
66 | Fixing of 4 way SP DB |
67 | Fixing of 16 way SP DB |
68 | Fixing of 12 way SP DB |
69 | Fixing of 8 way SP DB |
70 | Fixing of 2 Pole Isolator 40A |
71 | Fixing of 2 Pole ELCB 40A 100ma Leakage |
72 | Fixing of 1 Pole MCB 40A |
73 | Fixing of 1 Pole MCB 16A |
74 | Fixing of 1 Pole MCB 6A |
75 | Laying of6 sq. mm andPVC insulated Copper Wire |
76 | Laying of 2 nos of 2.5 sq. mm and 1 nos of 1.5 sq. mm PVC insulated Copper Wire |
77 | Laying of 2 X 10 SWG Bare Copper |
78 | Fixing of 3 nos 6A socket controlled by 2 switch |
79 | Fixing of 2 nos 6A socket controlled by 2 switch |
80 | Fixing of 1 nos of 16A socket controlled by 1 switch |
81 | Fixing of 1 nos of 6A socket controlled by 1 switch |
82 | Fixing of All materials for Plate(Galvanized Iron) Earthing as per IS-3043-1987 |
83 | Laying of GI/Cu earthing conductors inclusive of providing earthing terminations and bracing of the terminations using necessary clamps, screws and bolts, PVC sleeves, etc. 25x6 Cu strip |
84 | Fixing of exhaust FAN |
85 | Laying of 20 mm PVC Conduit accessories |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy