Tender For Additional/Alteration To Bathroom In Otm Accommodation Bldg No T-09, T-10, T-11 Of Bihar And Additional/Alteration Of Roof Of Bso Yard At Tibri Mil Stn Under Age B/R-Ii, Ge Gurdaspur., gurdaspur-Punjab

Military Engineer Services-MES has published Tender For Additional/Alteration To Bathroom In Otm Accommodation Bldg No T-09, T-10, T-11 Of Bihar And Additional/Alteration Of Roof Of Bso Yard At Tibri Mil Stn Under Age B/R-Ii, Ge Gurdaspur.. Submission Date for this Tender is 08-01-2024. Toilet Bathroom Tenders in gurdaspur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41069428
Corrigendum : Tender For Additional/Alteration To Bathroom In Otm Accommodation Bldg No T-09, T-10, T-11 Of Bihar And Additional/Alteration Of Roof Of Bso Yard At Tibri Mil Stn Under Age B/R-Ii, Ge Gurdaspur.
Open Tender
Indian
Punjab
gurdaspur
08-01-2024

Tender Details

Tender For Additional/Alteration To Bathroom In Otm Accommodation Bldg No T-09, T-10, T-11 Of Bihar And Additional/Alteration Of Roof Of Bso Yard At Tibri Mil Stn Under Age B/R-Ii, Ge Gurdaspur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 99800.0 /-
Tender Value
INR 49.90 Lakhs /-

BOQ Items

Name of Work: Additional/Alteration to bathroom in OTM Accn bldg No T-09, T-10, T-11 of Bihar and Addn/Alt of roof of BSO yard at Tibri Mil Stn under AGE B/R-II, GE Gurdaspur.
Sl. No. Item Description
1Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as directed.
2M&L for PCC 50 mm thick type C-1 (1:3:6) (using 20mm graded stone aggregate) as in plinth protection/ path finished even and fair complete all as specified and directed.
3M&L forPCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in sloping padding in roof slab finished even and smooth without using extra cement complete all as specified and directed.
4M&L Non skid dark coloured ceramic tiles 7 to 8 mm thick joint free (square/rectangular) area of each tile exceeding 0.11 sqm to 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement or clolured cement to matchincluding 15 mm thick screed bed in cm 1:6 & dismantling of existing complete all as spcd and directed
5M&L for ceramic glazed dark shed coloured tiles of size 350x250x7mm/ 450x350x7mm thick joint free on and including 10mm thick screed bed in cm(1:4) set and jointed in neat cement slurry and pointed in colored cement mixed with pigment to match the colour of tiles on vertical surfaces of well as in skirting/dado & dismantling of existing complete all as spcd and directed
6Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar
7M&L Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed in CM 1:4.
8Demolition of cement concrete (unreinforcement) above ground floor of any description and and in any position
9M&L for applying evenly a tack coat of hot industrial bitumen 85/25 at the rate of 1.6 kg per sq.m on roof surfaces complete all as specified and as directed.
10M&L APP based polymeric membrane minimum weighing 3 kg/ Sqm and minimum 3mm thick, reinforced with polyster non wove fabric (weight not less than 150 gms/ Sqm) by forced application with butane torch over entire roof area/ sunken floor with minimum overlaps of 100mm at the sides/ longitudinal edges of strips membrane and 150mm at the ends and sealed in, including bitumen primer @ 0.40 kg /Sqm after cleaning surface complete all as specified and directed.
11Supply only integral water proofing compound as per manufacturer"s instructions.
12M&L for PCC 1:5:10 type E-2 using 40 mm graded stone aggregate as in foundation, filling, sunken portion and mass concrete
13M&L 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in sub base for receiving the floor finishes complete all as spd.
14Taking down cement plaster any description on brick or stone walls, roof, ceiling etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
15M&L 15mm thick cement plastering in cm 1:6 on other than fair faces of brick or concrete surfaces, finished the surfaces even and smooth without using extra cement all as spd & directed.
16All as per item No 15 above but 5mm thick on ceiling in CM 1:3
17M&L 15mm thick cement plasteringin cm 1:4 on fair faces of brick or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified & directed.
18M&L for prepration of newly plastered/un plastered surfaces of wall and applying two coats of cement base paint of shade as approvedcomplete all as specified and directed.
19M & L preparation of new plaster surface of ceiling and applying three coats of white wash complete all as specified & directed.
20M & L preparation of new plaster surface of wall and applying three coats of white wash complete all as specified & directed.
21Preparation of new plastered surfaces and applying two coats of oil bound distemper (of approved shade)on walls over a coat of primercomplete all as specified.
22M&L for preparation of new steel surface exc 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer.
23Taking down chowkats with shutter n.exc 1.50 Sqm each (without taking off shutter for the chowkats) as spd
24S&F Factory Made Solid PVC Moulded Door Shutter with particle board core, 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, complete all as specified and directed.
25S&F MS Framed work as in chowkats, doors or gates of angle or other section with gusset plates, rails,braces, etc., and similar work incl primer conforming to FE-290 (Gde E-165) complete all as specified and directed.
26S&F 3mm thick figured glass pin head type glazing with oil putyin square n exe 0.5sq m in each pane.
27S&F Aluminiumanodized barrel tower bolt of extruded section 150mm long
28S&F aluminium alloyed handle casttype anodized of size 100mm long
29S&F butt hinges medium weight cold rolled mild steel 100mm size
30S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete
31S&F steel window/ ventilator box type made of ERW tube hollow P section of size 60mmX25mm outer frame (single rebated)comprising glazed skelton shutter frame of ERW tube P section including MS guard bars, fittings and fixtures welded to frame/ shutters all as shown on drg No. CEJZ/TD-1019/08 Sh 1/3 to 3/3 including Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts, including one shop coat of red oxide primer and two coats of synthetic enamel paint including taking down old existing window/ ventilator complete all as specified and directed. Notes: (i) Thickness of the sheet shall be of 18 gauge.(ii)Glass/ wire mesh, shall be measured and paid for separately
32S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks all as spd
33Taking up and down GI pipe 15mm bore including fittings, connection all as specified and directed.
34Taking up and down GI pipe 20mm bore including fittings, connection all as specified and directed.
35S&F GI tubing 15mm bore medium grade, fixed to wall/ceiling or laid in floor etc with all fittings ISI marked all as spd
36Fixing only GI tubing 15mm bore, fixed to wall/ceiling or laid infloor etc with new fittings ISI marked (old serviceable pipe re-used)
37S&F GI tubing 20mm bore medium grade, fixed to wall/ceiling or floor etc with all fittingsISI marked all as spd
38Fixing only GI tubing 20mm bore, fixed to wall/ceiling or laid infloor etc with new fittings ISI marked (old serviceable pipe re-used)
39S&F in repair Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe 15 mm bore complete all as specified and directed
40All as per item No 39 above but 20mm bore
41S&F rotational moulded polyethylene white water storage tank of 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old unsv WTall as spd.
42S&F in repair bib taps 15mm dia cast copper alloy chromium plated fancy type with capstan head screwed down screwed for iron pipe or for brass ferrule and fixed in repairs all as specified and directed.
43S&F in repair for 15mm bore Stop valves, cast copper alloy, screwed down , high pressure, with crutch or butterfly handles , screwed both ends for iron pipe or for unions, fancy type, chromium plated with long shank and cup ( concealed type) and fixed
44S&F in repair brass CP shower rose 125mm size with swivel joint fancy type as spd
45S&F in repair 20mm bore ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule.
46S&F in repair CP brass towel rail `D’ type 20mm dia. 60cm long fixed to wall all as spd and directed by Engr-in-Charge
47S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or floor all as specified & directed.
48S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls or floor complete all as specified.
49Dismantling of cast iron ,PVC or SGSW drain pipes, jointed in cement mortar and taking out of trenches , if required
50S&F in repair vitreous china squatting pan “Orrisa Pattern” white of size 580x440mm with internal foot rest with PVC `P’ or `S’ trap, integral foot rest including connection to trap and flushing pipe, flushing cistern etc completeall as specifiedNote:- Flush pipe and flushing cistern to be measured and paid separately.
51S&F in repairs 10 litres capacityPVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle,and connections, jointsto pipes,complete all as specified and as directed.
52S&F in repair Flush pipe of polythylene of low or high density or PVC, 32mm dia for low level cistern.
53S&F in repairs for vitreous china wash basin, white, size 630 mm x 450 mm flat back including brackets, brass CP waste coupling dia ofdischarge pipe 32mm, cutting for and pinning in ends of bracket or errecting stand complete all as specified and as directed.
54S&F in repair 15mm bore Pillar taps, cast copper alloy fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
55S & F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm
56S&F in repair vitreous China half stall type urinal , size 345x320x560mm, white, with brass CP spreader including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2),securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement paste, waste coupling of PTMT (half or full threaded) bore dia of discharge pipe 32mm (Minimum weight 45gms) complete all as specified and as directed.
57S&F PVC waste pipe 32mm dia 600 to 750mm long fixed to wash fitting of wash basin/ urinal all as specified and directed.
58S&F in repair 100 mm stainless steel grating with or without hinge type or hole type
59S&F PVC (SWR ) single junction ( single T ) 110 mm bore equal or unequal
60S&F PVC (SWR ) single junction ( single T ) 75 mm bore equal or unequal
61S&F PVC (SWR ) vent cowl 110 mm bore
62S&F PVC (SWR ) vent cowl 75mm bore
63M&L PVC (SWR ) floor trap 100/75 mm plain with grating incl. jointing with solvent cement
64M&L 110 mm bore PVC (SWR) P or S trap including jointing with solvent cement.
65S&F PVC (SWR ) bends 110 mm bore any radius
66S&F PVC (SWR ) bends 75 mm bore any radius
67S & F Stack clamps (for 100 mm bore pipe) out of 20 mm by 1.5 mm galvanised flat iron and iron stays, including bolts and nuts and securing ends of stays to wall or roof
68All as per Srl item No 67 above but for 75 mm bore pipe
69Demolition of brick work/ boulder masonary, built in cement mortar or cement lime mortar including all quoins, pillars etc. complete all as directed.
70M&L for brick work with sub class "B" old size bricks straight or curved on plan exc. 6m mean radius built in CM 1:4 brick complete all as spd.
71All as per Srl item No. 70 above but except bricks
72M&L for precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab for manholes and similar work etc complete all as specified.
73Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including,mild steel wire(annealed) not less than 0.9mm dia or securing with clips all as specified & directed.
74S&F 600mmx450mm beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.
75S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms)
76M&L coloured Chequered cement concrete tiles with grey cement and pigment , 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors in floors over and including 15 mm thick screed bed in cement mortar 1:6 & PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate ), 75 mm thick as in sub base of floor finishing even & faircomplete all as specified and directed.
77Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed.
78Dismantling timber scantlings, framed work, 40 sq. cm and over in section,in any position complete all as directed.
79Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings complete all as directed.
80Supply and fix for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws with side lap complete all as specified and as directed.
81Supply and fix for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats,etc. conforming Fe 410-W(Gde-E-250) quality-A complete all as specified and as directed.
82Supply and fix for mild steel work in tubular trusses, main columns, posts, for structural workincluding special shaped washer etc. complete using hollow mild steel sections of square or rectangular tubes conforming to IS: 4923-1997 gradeSt.-240 fixed with angle cleats or other connecting platescomplete all as specified and as directed.
83Supply and fix for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws with side lap complete all as specified and as directed.
84Material and labour for hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
85M&L for PCC 100 mm thick type C-1 (1:3:6) (using 20mm graded stone aggregate) as in floor sub base finished even and fair complete all as specified and directed.
86M&L for perforated particle board/ tiles for insulation and accoustic purposes, 60 cmx 60 cm in size, as in ceiling, flat or sloping fixed with nails to timber frame work or with staples on snap grid including demolition of existing board with frame work/ grid
87M&L for GI powder coated grid work of size605mm X 605mm, withmain tee of size 32mm X 23.5mm x 1.5mm thick, cross tee of size 25mm X 23.5mm x 1.28mm and angle of size 23.5mm X 23.5mm x 1.2mm fixed on wall, all powder coated finish on exposed faces of tee and angle, hung from ceiling using 2mm dia. G.I. suspension wires and "J" bolts, washers, nuts spaced at 1200 mm both ways including making niches for fans/ light all as specified and as directed.
88M&L for machine pressed precast cement concrete coloured interlocking paver block, of triangular / Zigzag / Haxagone/any shape/design and size as approved, 60mm thick, conforming to IS 15658-2006, M-35 with grey cement and pigments in floor/ paths/ pavement including filling the joints with sand complete all as specified and as directed.
89M&L for 25mm thick sand cushioning laid dry to the profileand consolidation complete all as specified and directed.
90E/M PORTIONTaking down carefully aluminium/copper point wiring for light, fan, bell, socket with complete fittings such as switches, ceiling roses, pendents, regulator socket etc completeat site and making goods disturbed surfaces of walls, floors etc.
91Point wiringwith PVC insulated and PVC sheathed single core multistrandedFRLS copper conductor cable of size 1.5 Sqmm (nominal area) using approved colour coding, 1100 volts grade, ISI marked,including PVC conduit heavy grade, 20 mm or higher dia. with fittings concealed in wall/ on surface for ceiling with continuous earth wire of PVC insulated and PVC sheathed single core multistrandedFRLS copper conductor cable of size 1.5 Sqmm (nominal area) 1100 volts grade, ISI marked and connecting to the common earth dolly including provn of 3mm thick plastic laminated sheet of appropriate size and sunken CI/pressed steel terminal boxes for mounting switches,sockets and regulators etc.including cutting chases andmaking good to the disturbed surfaces as per existing for One light point/fan point/ bell point controlled by one, one way switch complete all as specified and directed.
92All as per Srl item No 91 above but one 5 pin socket outlet 5/6 amps on same board.
93All as per Srl item No 91 above but 5/6 amps socket outlet on independent board.
94All as per serial item No. 91 here-in-before but with multistranded FRLS copper conductor cable of size 2.5 Sqmm (nominal area) with continuous earth wire multistranded FRLS copper conductor cable of size 2.5 Sqmm (nominal area) for 3 pin 15/16 Amps socket outlet on independent board.
95M&L for sub main wiring with two single core multi stranded PVC insulated, copper conductorof grade 1100 Volt , FRLS cableof size 6 sqmm (red for phase and black for neutral)and including electrical grade PVC conduitsof desired colour not less than 1.2 mm thick and 25 mm dia. & 6 sqmm FRLS multistranded copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth duly complete and taking down old unserviceable one. Note :- (a) Cost of making good the disturbed surface plastering/ filling putty alongwith matching with the existing finish is deemed to be included in therate quoted by contractor. (b) Three run of cable alongwith PVC conduit together shall be measured as single run.
96S&F switch piano flush type single pole one way5/6 amps.
97S&F socket outlet 3 pin 5/6 amps flush type.
98S&F switch flush type 15/16 amps single pole type one way
99S&F socket outlet 3 pin 15/16 amps flush type
100S&F in replacement surface mounting universal batten husing made of powder coated CRCA sheet suitabe for and upto 1 x 18/20W LED tube rodsingle sided complete all as specified and directed.
101S&F in replacement LED tube light 20W ultra bright LED polycarbonate tube light with very high efficacy suitable for fitting into tube light batten fitting completeall asas specifiedand directed. Note :- The contractor will submit the LM-80 and LM-79 report from manufacturer to Engineer-in-Charge before incorporating the items in work.
102Supply and fix for lamp holder angle type, PVC/ polycarbonate type with back plate, suitable for lamp holder base of and including 9 watt LED retrofit lamp complete all as specified and as directed.
103M&L ceiling rose, 3 terminals/ phase/ PVC/ polycarbonate, isolated body
104Supply andfixed in repair sheet metalenclosure forDB’s when MCB’s to beused, 240 volt 8 way SPN with bus barand double door complete all asspecified anddirected.Note :- All the connection of incoming and out going wire in MCB will be made with thimble with suitable size as directed
105S&F in repair MCBsinglepole 6amps to 32 amps complete all asspecified anddirected.
106S&F in repair MCB single pole and neutral 32 amps, complete all as specified and directed.
107Supply and fix exhaust fan, steel body AC single Phase 230V of size 300mm sweep with blades and frame and louvers complete all as specified and directed.
108Note: A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender.The Schedule of Credit is pre-priced by MES.The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail