Tender For Repair/Replacement Of Summer Appliances Under Garrison Engineer Amritsar Cantt, amritsar-Punjab

Military Engineer Services-MES has published Tender For Repair/Replacement Of Summer Appliances Under Garrison Engineer Amritsar Cantt. Submission Date for this Tender is 09-01-2024. AMC of Air Condition Tenders in amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41069067
Corrigendum : Tender For Repair/Replacement Of Summer Appliances Under Garrison Engineer Amritsar Cantt
Open Tender
Indian
Punjab
amritsar
09-01-2024

Tender Details

Tender For Repair/Replacement Of Summer Appliances Under Garrison Engineer Amritsar Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-01-2024
2 05-Jan-2024 Corrigendum NO 01 Other 09-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

NAME OF WORK: REPAIR/REPLACEMENT OF SUMMER APPLIANCES UNDER GARRISON ENGINEER AMRITSAR CANTT.
Sl. No. Item Description
1Taking downfor servicingof window/split/cassete type AC 1.5/2/2.5/4.0/5.0 TR Capacityincludingjet washing ,cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc.,and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
2Supply, fixing and connecting of new compressor of capacity 1.5 Ton for window/split type, medium temperature suitable for air conditioner of any make/type including replacement of foundation bolts, rubber pad, strainer capillary tubes, suction and discharge pipe line, wiring kit, Gas charging (R-22/R-134A/R-410A) and detect of leakage etc. and testing of new sealed unit compressoralongwith test certificate from manufacturer andone yearguarantee certificate complete all as specified and directed by Engineer-in-charge.
3All as per srl item No. 02 here-in-before but of 2.0 TO 2.5 Ton capacity.
4Supply, fixing and connecting of new compressor of capacity 3 to 5.5 Ton for split type, medium temperature suitable for air conditioner of any make/type including replacement of foundation bolts, rubber pad, strainer capillary tubes, suction and discharge pipe line, wiring kit, Gas charging (R-134A/R-410A) and detect of leakage etc. and testing of new sealed unit compressoralongwith test certificate from manufacturer andone yearguarantee certificate complete all as specified and directed by Engineer-in-charge.
5Taking down and Gas Charging of Air Conditioner window/split type of capacity 1.5/2.0 Ton with (R-22/R-32/R-134A/R-410A) or any other typegas including replacement of connection lead, tin coated copper thimbles, detecting of leakage and installation of AC at site and testing on full load for 24 hours continuously including detecting of gas leakage and rectifying it by gas welding orby any other means and cutting,brazing of copper tubecomplete all as specified and directed by Engineer-in-charge. Note : Gas charging once carried out by the contractor , in case of gas leakage if gas refilling required again thenthecost of refilling will be beared by the contractor.
6All as per srl item No. 05here-in-before but of 4.0 to 5.5 Ton capacity of cassett type/ductable AC. Note : Gas charging once carried out by the contractor , in case of gas leakage if gas refilling required again thenthecost of refilling will be beared by the contractor.
7Taking down blower motor from air conditioner of 1.5 / 2.5 Ton capacity and any make / Window type and replacing the new motor, single phase, 230 volt, 50 Hz, 1/5 HP capacity, in the same position, testing etc complete all as specified and directed by Engineer-in-charge.
8All as per srl item No.7 here-in-before but suitable for 4.0/5.5 Ton capacity of cassett / air cooled ductable type.
9Supply and fixing, in replacement, of Starting/Running capacitor suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
10Supply and fixing, in replacement, of thermostat switch of temperature range of 17°C to 30°C suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
11Supply and fixing, in replacement, offront grill with knob made of fiber plastic body suitable for window type AC of any make / type / capacity complete all as specified and directed by Engineer-in-Charge.
12Supply and fixing of factory made wall mounted/floor mounted type AC outdoor unit stand of superior quality duly coloured with two coat of synthetic enamel paint ( 1st grade quality) over a coat of red oxide zinc chrome primer. suitable for AC of 1.5 to 5 Ton capacity complete all as specified and directed.suitable size and grouting on wall or floor as directed by Engr-in-Charge
13Supply and fixing, in replacement, of starting relay suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
14Supply and fixing in replacement of out door unit complete 1.5 Ton/2 Ton split type AC including fan motor andcondensor coilof make as approved by GE, complete all as specified and directed. Note - All credit to be deposited to MES yard. It will be given to contractor after completion of work.
15Supply and fixing, in replacement, of fan motor ISI marked for outdoor unit of split type air conditioner of any make / type and capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
16Supply and fixing in replacementof electronic control circuit card suitable for air conditioner of any make / type and 1.5 / 2.0/2.5 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
17Supply and fixing in replacementof inverter typePCB foroutdoor unit suitable for air conditioner of any make / type and 1.5 / 2.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
18Supply and fixing in replacementof inverter typePCB for indoorunit suitable for air conditioner of any make / type and 1.5 / 2.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
19Repairof electronic control circuit card suitable for air conditioner of any make / type and 1.5 / 2.0/2.5 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
20Supply & fixing in replacement, of electronic control circuit with remote suitable for air cooled ductable type air conditioner of 4.0/ 5.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
21Repair of electronic control circuit with remote suitable for air cooled ductable type air conditioner of 4.0/ 5.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
22Material and Labour for scraping of old paint by wire brush frombody of window type/Split AC of any capacity and applying base material for smooth surface and applying2 coats of synthetic enameled spray paint over one coat of primer complete all as specified and directed by Engineer-in-Charge.
23Supply and fixing in replacement of Indoor unit complete 1.5 Ton/2 Ton split type AC including PCB kit , Remote, complete wiring , Blower motor ,blower fan , condencing coil , mounting plateof make as approved by GE, complete all as specified and directed by Engineer-in-Charge. Note - All credit to be deposited to MES yard. It will be given to contractor after completion of work.
24Material and Labour for for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor FR cable conforming to IS specifications, 2 runs of 6 sqmm including 1 run of 6 sq mmsingle core multistranded copper conductor,PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . Note :2 Run of 6 sqmm,1 Run of 6 sq mm and 1 run of PVC conduit will bemesuared as 1 unit.
25Material and Labour for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 4 sqmm including 1 run of 4 sq mmsingle core multistranded copper conductor,PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring .Note :2 Run of 4 sqmm,1 Run of 4 sq mm and 1 run of PVC conduit will bemesuared as 1 unit.
26Supply and fixing in replacement of Evaporaror/Condenser cooling coil of copper 1.5 ton /2 ton split type/WindowAC of suitable make approved by CE WC as directed by Engr-in-Charge
27Supply and fixingof copper pipe/tube of outer diameter ofsize 1/4" alongwith necessary fitting for installation of AC complete all as specified and directed by Engineer-in- Charge.
28Supply and fixingof copper pipe/tube of outer diameter ofsize 3/8" alongwith necessary fitting for installation of AC complete all as specified and directed by Engineer-in- Charge.
29supply and fixing in replacement of PVC drain pipe 3 mtr longsuitable for split type AC all as specified and directed by engr-in-charge.
30Material and Labour for taking downAir conditioner split/window type of any capacityincluding restoring gas , opening of copper pipeand refixing after repair completewith all connectionas per directed by Engr-in- Charge.Note :- Driling hole in wallfor copper pipe is included in unit rate quotated.
31REFRIGERATOR Material and Labour forTaking out compressor sealed unit from the refrigerator/deep freezer any capacity and make including removal of unserviceable parts/ spares, such as over load protector, strainer capillary tube etc complete all as specified and directed by Engineer-in charge.
32Supply, fixing connecting andtestingof new compressor alongwith test certificate from manufacturer andone yearguarantee certificate suitable for refrigerator/deep freezer of capacity 320/ 310/ 280/ 220 ltrs and any make/type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line and subsequentlyGas charging ofgas type as required on site and detect of leakage etc complete all as specified and directed by Engineer-in charge.
33All as per srl item No. 32here-in-before but for capacity 165/180 ltrs.
34Material and Labour for gas charging of refrigerator/deep freezer of any make/type/capacity of anyas required on site type refrigerant gas complete in all respect including installation at site testing of service for 24 hours etc complete all as specified and directed by Engineer-in charge..Note : Gas charging once carried out by the contractor , in case of gas leakage if gas refilling required again thenthecost of refilling will be beared by the contractor.
35Supply and fixing of starting relay and overload protector ISI marked suitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
36Supply and fixing of thermostat switch with knob ISI marked suitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
37Supply and fixing offreezer suitable for refrigerator of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
38Supply and fixing of glass/PVC shelf/cover for vegetable tray suitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
39Supply and fixing of evaporator coil ISI marked suitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
40Supply and fixing in replacement of Door Lock with door gasket for refrigerator 165 to 310 ltrs complete all as specified and directed by Engineer-in-Charge.
41Supply and fixing in replacement of Interior light fittings with bulb complete all as specified and directed by Engineer-in-Charge.
42Supply and fixing in repair/replacement of printed circuit board for refrigerator of 180/220/300 capacity complete all as specified and directed by Engineer-in-Charge.
43Supply and fixing in replacement of heaterfor refrigerator of 180/220/300 capacity complete all as specified and directed by Engineer-in-Charge.
44Supply and fixing in replacement of fan motor forrefrigerator/deep freezer of 180/220/310 ltr capacity complete all as specified and directed by Engineer-in-Charge.
45Supply and fixing ofcondenser coil ISI marked suitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
46WATER COOLER Material and Labour for taking out existing unserviceable compressor sealed unit from the water cooler of any make/type/capacity including removing of all other unserviceable parts / spares such as strainer filer, capillary tube, suction / discharge pipe, thermostat switch, float valve, push cock, running capacitor, starting capacitor, over load relay etc reassembling of water cooler and restoring water connection, complete all as specified and directed by Engineer-in charge.NOTE The rates for above items are deemed to include for transportation to & fromWater coolers to workshop as approved by Engineer-in-charge for necessary repairs and testing of Water coolers at workshop& replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one.
47Supply, fixing and connecting of new compressor sealed unit suitable for water cooler of any make/type and 150 ltr ,120 ltr/ hr cooling capacity, medium temperature range, including replacement of filter and making connectionand detect of leakage and rectifying it by gas welding or any other means etc including testing of new sealed unit compressoralongwith test certificate from manufacturer andone yearguarantee certificate complete all as specified and directed by Engineer-in charge.
48All as per srl item No 47 here-in-before but water cooler of any make/type and 40/60, 40/80 ltr/ hr cooling capacity.
49Material & Labour for Gas charging of water cooler of any make/type but of 150/120 ltrs / hr cooling capacity with (R-32/R-134A/R-410A) or any other type refrigerant gas complete in all respect, detect of leakage and rectifying it by gas welding or any other means etc including installation at site, testing of water cooler on full load for 24 hours continuously etc complete all as specified and directed by Engineer-in charge..Note : Gas charging once carried out by the contractor , in case of gas leakage if gas refilling required again thenthecost of refilling will be beared by the contractor.
50Material & Labour for Gas charging of water cooler of any make/type but of 40/60 ,40/80ltrs / hr cooling capacity with (R-32/R-134A/R-410A) or any oher type refrigerant gas complete in all respect, detect of leakage and rectifying it by gas welding or any other means etc including installation at site, testing of water cooler on full load for 24 hours continuously etc complete all as specified and directed by Engineer-in charge..Note : Gas charging once carried out by the contractor , in case of gas leakage if gas refilling required again thenthecost of refilling will be beared by the contractor.
51Supply, fixing and connecting of new fan motor with blade ISI marked in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-charge.
52Supply, fixing and connecting of Starting/running capacitor ISI marked in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-charge.
53Supply, fixing and connecting of thermostat switch ISI marked in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-charge.
54Supply, fixing and connecting of chromium plated push cock tap, in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-charge.
55Supply, fixing and connecting of PVC heavy duty waste water pipe of 32/40 mm size and min 1.5 mtr long, including repair of waste water tray in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-charge.
56Supply and fixing of evaporator coil ISI marked suitable for water cooler of any make/type/capacity including all fixing accessories and making connection / detecting leakage and gas charging etc complete all as specified and directed by Engineer-in charge.
57Supply and fixing of condenser coil ISI marked suitable for water cooler of any make/type/capacity including all fixing accessories and making connection etc complete all as specified and directed by Engineer-in charge.
58Material and labour for repairing to base/stand of water cooler of any make/type/capacity including welding of MS/GI sheet 16 SWG of suitable size to fill up rusted patches, grinding and applying base material for smooth surface and applying 2 coat of synthetic enameled spray paint of existing colour over one coat of primer etc complete all as specified and directed by Engineer-in-charge.
59Material and labour for scraping of old paint / rust etc by wire brush frombody of water cooler of any make/type/capacity and applying base material for smooth surface and applying2 coat of synthetic enameled spray paint over one coat of primer after denting etc complete all as specified and directed by Engineer-in-charge.
60Supply and fixing in replacement of Relay/overload protector suitable for water cooler of any size/type as per site requirement complete all as specified and directed by Engineer-in-Charge.
61DESERT COOLER Supply, fixing and connecting new fan motor, single phase 230 volt 50 Hz copper wounded three speed suitable for desert cooler of 500 mm sweep size or any other size as per site requirementetc completeincluding dismantling and removing of existing unserviceable fan motor with blades from the desert cooler of any make/type/capacity including removing of all fixing accessories etc and refixing the Fan motor with blades complete all as specified and directed by Engineer-in charge.
62Supply, fixing and connecting new crompton greavesheavy duty exhaust fan motor 380 mm including fan blade , single phase 230 volt 50 Hz copper wounded three speed suitable for desert cooler of 500 mm sweep size or any other size as per site requirementetc completeincluding dismantling and removing of existing unserviceable fan motor with blades from the desert cooler of any make/type/capacity including removing of all fixing accessories etc and refixing the Fan motor with blades complete all as specified and directed by Engineer-in charge.
63Supply, fixing and connecting new submerisble type tullu pump impeller type for desert cooler of capacity 15 to 20 watt, single phase 230 volt 50 Hz copper wound etc incl fixing accessories complete all as specified and directed by Engineer-in charge.
64Supply and fixing in replacement of wooden wool pads including wire mesh suitable for 4000/5000 CFM complete all as specified and directed by Engineer-in charge.
65Material and labour for scratching of old paint and rust by wire brush and applying two coats of spray paint of off white / gray colour over one coat of primer ( red oxide ) including black bitumen paint at in side body of desert cooler complete all as specified and directed by Engineer-in charge. Note : The compressor and spray machine shall be arranged/brought by contractor at E/M yard and no extra cost shall be paid to the contractor in this effect.
66Supply and fixing in replacement of selector switchand piano switch for desert cooler,single phase 230 volts, ISI marked complete all as directed by the Engineer-in-Charge.
67Supply and fixing in replacement of side grill complete made out of 22 SWG gauge GI sheet including applying two coats of spray paint of off white / gray colour over one coat of primer ( red oxide ) suitable for desert cooler of capacity 4000/5000 CFM complete all as directed by the Engineer-in-Charge.
68Supply and fixing in replacement offront grill made out of GI sheet of 20 SWG gauge including applying two coats of spray paint of off white / gray colour over one coat of primer ( red oxide ) suitable for desert cooler of capacity 4000/5000 CFM complete all as directed by the Engineer-in-Charge.
69Supply and fixing in replacement of factory made metalic blade suitable for desert cooler of capacity 4000/5000 cuf/M complete all as directed by the Engineer-in-Charge.
70Supply and fixing in replacement of PVC pipe of 15 mm dia with water PVC distribution and PVC elbow complete all as specified and directed by the Engineer-in-Charge.
71Supply and fixing in replacement of legs for fan motor made out for 18 SWG MS platecomplete all as specified and directed by the Engineer-in-Charge.
72Supply and fixing PVC connection 15 mm size with PTMTnuts of length 600mm complete all as specified and directed by the Engineer-in-Charge.
73Supply and fixing ball brassvalves, high pressure, with polythene float and flynut complete , screwed for iron pipe or brass ferrule bore of pipe 15mm dia complete all as specified and directed by the Engineer-in-Charge.
74Supply and fixing galvanized iron steel tubing medium grade 15mm bore with all fittings and fixed to walls, ceiling or on floor fixed with approriate wire including taking down unserviceable pipe complete all as specified and directed by Engineer-in-Charge.
75Supplying and fixing MS framed works as in frame of desert cooler of angle or other section with gusset plates, rails, braces etc , including drilling and grouting in wall complete all as specified and directed by Engineer-in-Charge.
76Supplyand fixing in replacement of desert cooler body made of20 guage PGI Sheet suitable for evaporative type desert cooler of size 67x67x87 cm including side panel-03 nos and front grill with 20 guage PGI sheet and water tank height 20 cm and grill with fins, electriclal wiring and connection with on/off switch piano type,selector switch with distribution PVC cable 3 core 23/0.0076-3m withplug top 5 Amp-01 No,15mm float vlave-01 and legs for motor fixing including duly painted complete body internaly and externaly and all side panel inner and outer side with 2 coat sythetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
77Supply and Fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed by Engineer-in-Charge.
78Supply and Fixing in replacement of PVC stop cock suitable for GI tubing of size 15 mm dia complete all as specified and directed by Engr-in-charge.
79VOLTAGE STABILIZER Material and labour for stripping up of voltage stabilizer and replacing of main transformer 5 KVA capacity with super enameled copper wire of existing gauge including varnishing, heating and refiting (Make : STP/ Devidayal / Chetak) for input variation between 140 volt to 280 volt and output volt of 230 volts, 50 Hz including replacement of main circuit and testing for low and high voltageetc complete all as specified and directed by Engineer-in-charge.
80Material and labour for stripping up of voltage stabilizer and replacing of main transformer 3 to 4 KVA capacity with super enameled copper wire of existing gauge including varnishing, heating and refiting (Make : STP/ Devidayal / Chetak) for input variation between 140 volt to 280 volt and output volt of 230 volts, 50 Hz including replacement of main circuit and testing for low and high voltageetc complete all as specified and directed by Engineer-in-charge.
81Material and labour for stripping up of voltage stabilizer and replacing of main transformer 0.5 to 2.00 KVA capacity with super enameled copper wire of existing gauge including varnishing, heating and refiting for input variation between 140 volt to 280 volt and output volt of 230 volts, 50 Hz including replacement of main circuit and testing for low and high voltageetc complete all as specified and directed by Engineer-in-charge.
82Supply and fixing in replacement of old analog type AC ammeter 0-100range complete all as specified and directed by the Engineer-in-Charge.
83Supply and fixing in replacement of old voltmeter 0-300 volt range complete all as specified and directed by the Engineer-in-Charge.
84Supply and fixing in replacement of indicator lamp Neon type green / red etc complete all as specified and directed by the Engineer-in-Charge.
85Supply and fixing in replacement of relay 24 volt, 25 Amps with cut off circuit , ISI marked suitable for voltage stabilizer of any type/make/capacity etc complete all as specified and directed by the Engineer-in-Charge.
86Supply and fixing in replacement of electronic circuit ISI marked suitable for voltage stabilizer of any type/make/capacity etc complete all as specified and directed by the Engineer-in-Charge.
87Supply and fixing in replacement of Voltage stabiliser, copper wound of 4to 5 KVA capacity digital display type having I/P Correction Range of 120- 280 volt complete all as specified and directed by Engineer-in-charge.
88Supply and fixing Digitaltype Voltmeter0 to 300 volts any type shape single phase 50 Hz AC supply, complete all as specified and directed by Engineer-in-charge
89Taking down existing unserviceablecopper flexible cable 3 core supply and fix new cable PVC insulated 3 core,copper conductor 2.5 sqmm complete all as specified and directed by Engineer-in-charge.
90CENTRAL AC PLANT Material and labour for maintenance of central AC plant (chiller unit01x 39 TR) with complete decsaling of condencer with the help of pressure motor and decsaling material all as specified and directed by engineer-in- charge
91Material and labour for maintenance of Air handling unit with complete cleaningwith the help of pressure motor and oil and greasing to all bearingsall as specified and directed by engineer-in- charge.
92Repair / replacement of Air handling unit fine filters suitable for ICUs all asper existing sample allspecified and directed by engineer-in-charge
93Repair / replacement of Air handling unit wire mesh filters suitable for ICUs all asper existing sample allspecified and directed by engineer-in-charge
94Supply and fixing Fan beltNo- A1382 Lp/A53 for AHU motor complete all as specified and directed by Engineer-in-Charge.
95Supply and fixing Fan beltNo- A1433 Lp/A53 for AHU motor complete all as specified and directed by Engineer-in-Charge.
96Supply and fixing Fan beltNo- B 1618 Lp/B62 for AHU motor complete all as specified and directed by Engineer-in-Charge.
97Supply and fixing Cooling tower fan assembly (1200 mm)blade as per sample complete all as specified and directed by Engineer-in-Charge.
98Supply and fixing digital wall mounted temp and humidity meter ISI marked complete all as specified and directed by Engineer-in-Charge.
99Supply and fixing Pressure guage of 100 psi kg/ cm sq for condencing and chiller water pipe line complete all as specified and directed by Engineer-in-Charge.
100Material and Labour for charging of refrigerant Gas R-407 C complete all as specified after carrying out leak test and arresting the leakage complete all as specified and directed by Engineer-in-Charge.
101Material and Labour for servicing/cleaing of cooling tower complete all as directed incl removal of all scale and replament of Nylon Jali as per sample and complete all as specified and directed by Engineer-in-Charge.
102Material and Labour for servicing of Condensor / chiller pump of capacity 5 HP complete incl oiling greasing of bearing , replacement of shaft seal of Pump setcomplete all as specified and directed by Engineer-in-Charge.
103Supply and fixing in replacementbutterfly valve ISI marked 100 mm dia complete all as specified and directed by Engineer-in-Charge.
104Supply and fixing in replacementbutterfly valve ISI marked 150 mm diacomplete all as specified and directed by Engineer-in-Charge.
105Material and labour for painting of 100, 150 , 200 mm dia water pipes as per existing colour all as specified and directed by Engr-in-charge
106Supply and fixing in replacement chiller sensor all as per make and sample complete all as specified and directed by Engineer-in-Charge.
107Attending day to day emergency complaints for Air conditioner,water cooler current leakage, sparking, not working etc ; Complete all as specified and as directed by Engineer-in-Charge. Notes for Sl Item No.107 (i) Contractor has to take the complaint at MES power house (E/M) from Concern JE E/M Daily Basis (Except Sunday & holiday). (ii) Contrcator has to attend the complaint within 24 Hrs after recived from JE E/M. (iii) Contrctor has to provide the Mobile no so that massges can be send on the same mobile No. (iv) For non collection of complaits from JE E/M Rs.500/- per day will be charged. (v) For Non attendence of complaints in 24 Hrs Rs.1000/- per day per complaint will be charged (vi) Contractor has to return the complaint duly signed from the user with time & date.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail