Tender For Repairs To External Electrification And Road Works At Od Residential, Tech Area, Mh And Other Areas Und, avadi-Tamil Nadu

Military Engineer Services-MES has published Tender For Repairs To External Electrification And Road Works At Od Residential, Tech Area, Mh And Other Areas Und. Submission Date for this Tender is 15-01-2024. Electrification Work Tenders in avadi Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

41066138
Corrigendum : Tender For Repairs To External Electrification And Road Works At Od Residential, Tech Area, Mh And Other Areas Und
Open Tender
Indian
Tamil Nadu
avadi
15-01-2024

Tender Details

Tender For Repairs To External Electrification And Road Works At Od Residential, Tech Area, Mh And Other Areas Und; 1 Boq Uploaded Onnov 2023 2 Sch A Part-I ( Ext Electrical Works ) 3 Excavating In Trenches, Not Exceeding 1.5M Wide And Not Exceeding 1.5M Depth And Getting Out Soft / Loose Soil For Laying Cables / Pipes / Erection Of Poles Etc All As Specified And As Directed. 4 All As Per Item No 3 Above But Depth Exc 1.5 Mtr And Not Exc 3.00 Mtr All As Specified And As Directed. 5 Removing Excavated Material Soil Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed. 6 Returning, Filling In Soil Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Each All As Specified And As Directed. 7 Sand Cushioning To Underground Cables In Cable Ducts By Filling River Sand Up To Top Of The Cable Ducts In 11 Kv Sub Stations Or In Trenches As Specified In Ssr Pt I Complete. ( Punned Thickness Will Only Be Measured ) 8 Supply And Laying Heavy Duty Reinforced Precast Concrete Cable Cover Isi Marked , Class Hv, Type 1, Flat, Size ( 300 X L80 ) Mm X 40Mm All As Specified And As Directed. 9 Cement Concrete In Foundations Filling And Mass Concrete 1:3:6 Mix Type C-2 ( Using 40Mm Graded Stone Aggregates ) For Transformer Staging / Pole Foundation All As Specified And Directed. 10 Cement Concrete In Coping Of Type C1 1:3:6 Mix ( Using 20Mm Graded Stone Aggregates ) For Transformer Staging / Pole Coping All As Directed. 11 Supply And Laying In Trenches / Poles / Wall Etc Ht Ug Cable Xlpe Insulated With Multistranded Aluminium Conductor Armoured With Galvanised Steel Wire / Taps 11000 Volts Grade Conforming To Is Specifications And Of Following Sizes Including Taking Down The Existing Unserviceable Cable Complete All As Specified And As Directed. Note : - ( A ) .Earthwork, Sand Cushioning, Protection For Cable Etc As Required Shall Be Measured And Paid Seperately. ( B ) Lugs And Glands Shall Be Used Appropriately Wherever Required While Connecting Cables To The Panel Board And The Quoted Rates Are Deemed Be Include For The Same. 12 Ht Ug Cable 3 Core 95 Sqmm 13 Ht Ug Cable 3 Core 120 Sqmm 14 Ht Ug Cable 3 Core 185 Sqmm 15 Ht Ug Cable 3 Core 240 Sqmm 16 Indoor Termination Cold Shrink Type Joint For 11 Kv ( Earthed ) Grade Underground Cable Including Jointing Materials And Accessories Including Labour Complete For Making Joint Suitable For Ht, Ug, 3 Core, Xlpe / Armoured Heavy Duty Cable With Aluminium Conductor Of Following Sizes Complete All As Specified And As Directed 17 Ht Ug Cable 3 Core 95 Sqmm 18 Ht Ug Cable 3 Core 120 Sqmm 19 Ht Ug Cable 3 Core 185 Sqmm 20 Ht Ug Cable 3 Core 240 Sqmm 21 Outdoor Termination Heat Shrink Type Joint For 11 Kv ( Earthed ) Grade Underground Cable Including Jointing Materials And Accessories Including Labour Complete For Making Joint Suitable For Ht, Ug, 3 Core, Xlpe / Armoured Heavy Duty Cable With Aluminium Conductor Of Following Sizes Complete All As Specified And As Directed :- 22 Ht Ug Cable 3 Core 95 Sqmm 23 Ht Ug Cable 3 Core 120 Sqmm 24 Ht Ug Cable 3 Core 185 Sqmm 25 Ht Ug Cable 3 Core 240 Sqmm 26 Straight Through Heat Shrink Type Joint For 11 Kv ( Earthed ) Grade Underground Cable Including Jointing Materials And Accessories Including Labour Complete For Making Joint Suitable For Ht, Ug, 3 Core, Xlpe / Armoured Heavy Duty Cable With Aluminium Conductor Of Following Sizes Complete All As Specified And As Directed :- 27 Ht Ug Cable 3 Core 95 Sqmm 28 Ht Ug Cable 3 Core 120 Sqmm 29 Ht Ug Cable 3 Core 185 Sqmm 30 Ht Ug Cable 3 Core 240 Sqmm 31 Polymer Switch Air Break Gang Operated Triple Pole, Mechanically Operated Mounted On Polymer Insulator And Steel Frame With Operating Mechanism Worked From Ground Level Complete With 9Number Polymer Insulators Of Rating Upto 200 Amp 11000 Volts Including Necessary Length Of Down Pipe Made Up Of Galvanized Iron Medium Grade 20Mm Bore With Operation Handle And Locking Arrangements Including Taking Down The Old Unserviceable One Complete All As Specified And As Directed . 32 Supply And Laying In Trench / Fixed On Pole Galvanized Iron Tubing, Light Grade Of Size 80 Mm Dia Complete Including All Necessary Fittings Including Taking Down The Old Unservicable One Complete All As Specified And As Directed. Note : Earthwork As Required Shall Be Measured And Paid Separately. 33 Pin Type Polymer Insulator, Polymer, Including One Galvanised Mild Steel Spindle, Two Galvanised Iron Washers And One Galvanised Iron Nut For 11000 Volts Grade Including Taking Down The Old Unserviceable One Complete All As Specified And Directed. 34 Disc Type Polymer Insulators, Creepage Distance 120 Mm, T&C And B&S End Fitting Type Suitable For High Tension Over Head Conductors Working Pressure 11000 Volts Gradeincluding Taking Down The Old Unserviceable One Complete All As Specified And As Directed . 35 Loop Type Poecelain Insulator, Vitreous White, Brown Or Green With Over All Dimension 90Mm X 140Mm Clearance Of Hole 25.5Mm Including Taking Down The Old Unserviceable One Complete All As Specified And As Directed. 36 Acsr Conductor Of Any Size For Ht Over Head Line And Jumpers On Pcc / Rcc / Steel Pole Including Binding Wires Line Connecting Up Etc Of Any Size Including Taking Down Old Unserviceable One Complete All Specified And Directed . 37 Anti-Climbing Device, Spikes Type, Fabricated Out Of Ms Bars ( Round, Square And Flat ) Including Nuts, Bolts, Washers And Welding In Two Halves Made To Shape To Suit The Cross Section Of The Pole Of Any Size Including Taking Down Old Unserviceable One Complete All Specified And Directed . 38 Cross-Arms Bracing Supports Clamps And Back Pates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending, Cold Or Hot Drilling Holes For Insert Bolts In Any Shape Or Size As Indicated And As Directed And Inclusiv Of One Coat Of Redoxide Primer And One Finishing Coat Of Aluminium Paint Including Taking Down Old Unservicable One Complete All As Specified And As Directed. 39 Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled White, With Letters, Figures And Conventional Skull And Bones In Signal Red Colour And Fixed With M.S. Clamps, Bolts And Nuts Of Approved Size, For Ht Opf Size 25X20cm Size Including Taking Down The Existing Unserviceable One Complete All As Specified And As Directed. 40 Polymer Lightning Arrester Expulsion Type Complete With All Fitting Transmission Class, Discharge Capacity 200-800 Amp 11000 Volts Rating Including Taking Down Old Unserviceable One Complete All As Specified And As Directed. ( Make : Jyoti / Denson Or Equivalent As Approved By The Ge ) 41 Supply And Laying Synthetic Insulated Mat Of Size 2.50Mm Thick For Voltage 11 Kv For Electrical Purpose As Per Is 15652-2006 Suitable For Electrical Shock Safety Of Size ( 2.00 X 1.00 ) Mtr Including Taking Down Old Unserviceable One Complete All As Specified And As Directed. 42 Supply And Laying Synthetic Insulated Mat Of Size 2.5M Thick For Voltage 11 Kv For Electrical Purpose As Per Is 15652-2006 Suitable For Electrical Shock Safety Of Size2mx1m Including Taking Down Old Unserviceable One Complete All As Specified And As Directed. 43 Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25 M Deep Below Normal Ground Level With The Top Edge Of Earth Plate At A Depth Of Not Less Than 1.5M Below Normal Ground Level Connected To Gi Earth Strip 32X6 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Made Out Of Gi And Gi Earth Strip Protected By 40 Mm Bore Light Grade Gi Pipe, Watering Arrangement By Provision Of 20Mm Dia Gi Pipe Medium Grade With Cast Iron Funnel, Provision Of Test Point And Connected To Main Control Board All As Shown In Electrical Plate No 3 Of Ssr Part I Ncluding Necessaryearth Work And Excavation In Any Type Ofsoil, Plain Cement Concrete 1:3:6, Typec1 Chamber, Reinforcedcement Concrete Cover Slab With Locking Arrangement And Handle Of 10Mm Dia Ms Round Bars 450Mm Long, 1:2:4 Type B1, 50Mm Thick With 8Mm Diatmt Barsat140mmcentreto Centrebothways, Gi Pipe Of Bore 20Mm Medium Grade For Watering With Funnel, Wiremesh, Salt, Charcoal, Lugsincluding Testing Complete All As Specified And As Directed. 44 Hardcore Of Broken Stone Boulders Of Guagenot Exceeding 63Mm, Deposited, Spread And Levelled In Layers Not Exc 15 Cm Thick, Watered And Rammed To A True Surfaces Using Broken Stones Etc Complete All As Specified And As Directed. 45 Horn Gap Typefuse Unit, 11000 Volts Grade, Mounted On Polymer Insulators And Steel Frame, Single Pole, Fixed On Dp Structures Including Taking Down Old Unservicable One Complete All As Specified And Directed. 46 Expulsion Type Drop Out Fuse Element 10Amps And Upto 100 Amps Suitable For 11 Kv Horn Gap Type Fuse Including Taking Down Old Unserviceable One Complete All As Specified And As Directed. 47 Service Charges For Carrying Out Servicing And Overhauling Of Under Mentioned Capacities Ht Vcb By Drawing Out The Draw-Out Module Of The Breaker, Carrying Out Complete Cleaning With Clean Cloth & Cleaning Agent, Lubrication Of The Mechanism & Greasing With High Temperature Molly Grease, Testing For Smoother On / Of Operation, Carrying Out Relay Calibration Of Protection Relay By Secondary Current Injection Methods To Check Trip Time Characteristic Of Relays, Checking Of Healthiness Of Cts & Pts. Checking Of Ir Value Of Interrupters, Healthiness Of Protection Tripping Of Circuit Breaker Etc. Choking And Servicing Switchgear Interlocks And Safety Like Mechanical - 1. Positive Interlock, 2.Negative Interlock, 3. Spring Discharge Interlock, 4. Padlocks, 5. Key Interlocking 6. Safety Roll In Stop, 7. Safety Roll - Out Stop, 8. Rating Interference Interlock. Electrical - Interlock Switches ) Checking Of Electrical Operations Of The Breaker For On / Off & Trip Operation For Incomer And Outgoing Including Submission Of Service & Test Reports. Make : Crompton Greaves.Note : ( I ) Servicing Of The Vcb To Be Done By Authorised Service Provider Of The Manufacturer As Approved By The Accepting Officer. ( Ii ) Proper Photographic Record Will Be Maintained With Dates Of Work Carried Out Duly Signed By The Eng-In-Charge. ( Iii ) Unit Rate Quoted Is Deemed To Be Inclusive Of Spares / Lubricants Other Than The Spares Mentioned Underitem No 44.00 To 51.00 ( Iv ) The Rate Quoted Is Deemed To Be Inclusive Of Labour Charges For Fixing Taking Down And Renewal Of Defective Spares. 48 Vacum Circuit Breaker ( Vcb ) Amps:400A 49 Vacum Circuit Breaker ( Vcb ) 630 Amps To 800A 50 Supply And Replacement Of Following Items Of400 To 800 Ampere Capacity, 11 Kv, 3 Phase, 50 Hz, Ht Vcb Of Any Quanity During Servicing Of Vcb As Stated In Item No 31 Above Including Taking Down Old Unservicable One Complete All As Specified And As Directed. 51 Replacement & Fitting Of Charging Gear Complete 52 Replacement & Fitting Of Rack In And Out Gear Complete 53 Replacement & Fitting Of Rack In And Out Mechanism Complete. Make : Abb Or Equivalent 54 Replacement & Fitting Of Spring Charging Mechanism Complete 55 Replacement & Fitting Of 630A Vacuum Interrupter Complete. Make: Cg Or Equivalent 56 Replacement & Fitting Of Tripping Relay Complete. Make: Ashida Avajh13 Or Equivalent 57 Replacement & Fitting Of Tripping Coil Complete. Make: Cg Or Equivalent 58 Replacement & Fitting Of Over Current Earth Fault Relay, Phase And Earth Current Input 1 / 5A, Ice Version. Make : Cg Or Equivalent 59 Indicating Lamp Of Any Type / Model / Capacity In Ht Vcb / Sfu Panels Including Taking Down Old Unserviceable One Complete All As Specified And As Directed.Make: Siemens Or Equivalent 60 Multifunction Meter With Rs Port Of Any Type / Model / Capacity In Ht Vcb / Sfu Panels Including Taking Down Old Unserviceable One Complete All As Specified And As Directed.Make : L&T 4410 Series / Abb / Selec As Approved By The Ge 61 Tnc Switch Of Any Type / Model / Capacity In Ht Vcb / Sfu Panels Including Taking Down Old Unserviceable One Complete All As Specified And As Directed.Make: Kaycee 62 Heating Element 250 Watts Of Any Type / Model / Capacity In Ht Vcb / Sfu Panels Including Taking Down Old Unserviceable One Complete All As Specified And As Directed. Make : Rs Pro Or Equivalent 63 Finding Fault Ofht Xlpe Ug Cable Aluminium Conductor Armoured Of Cable Size 95 Sqmm To 240 Sqmm By Fault Locater Including Taking Out Cable From Trenches / Poles / Structure And Relaying After Fault Rectification Complete All As Specified And Directed. Note: ( I ) Quoted Rate Is Deemed To Be Included Of Charges Of Ht Fault Locater And The Complete Earth Work Involved. ( Ii ) The Work Should Be Completed Within 12 Hrs, ( Iii ) Jointing Kit Will Be Measured And Paid Separately Under Relevant Item. 64 Service Charges Forcarrying Out Complete Servicing Of Ab Switch Bylubrication Of The Mechanism & Greasing With Petroleum Jelly Complete All As Specified And As Directed.Note: Minimum Spares / Lubricants And Tools Required For The Jobshould Beincluded In The Coated Rates. 65 Labour Only For Restraining Of Acsr Conductor From Pole To Pole 3 Conductors With Maintain Minimum Sag As Per Ht Specification All As Specified And As Directed By Engr-In-Charge.Note :- Minimum Spares And Tools Required For The Job Should Be Included In The Coated Rates. 66 Ht 11 Kv Phase / Line Seperator Suitable For Fixing Oh Acsr Conductor, 11 Kv Range Including Taking Down Old Unserviceable One Complete All As Specified And As Directed. 67 Painting Outer Surfaces Of Transformer Of Capacity Above 100Kva, Any Type / Make / Model, Pole Or Plinth Mounted, Installed At Various Sub Stations With One Coat Of Synthetic Enamel Paint Of Approved Shade Including Cleaning The Old Painted Surfaces And Writing Sm / Mes Numbers, Capacity, Make, Date Of Oil Testing Etc., Complete All As Specified And As Directed. ( Photographic Record Of The Work Will Be Maintained And Kept On Record For The Perusal Of The Accepting Officer ) 68 Preparation Of Old Painted Surfaces, Removing Dust And Other Deposited Materials By Scraping From Ht / Lt Tubular Pole 11Mtr Long, Painting Of Pole With One Coat Of Black Paint Upto 1 Mtr From Bottom And Painting The Rest Of The Pole Including Cross Arms Cable Protection Pipe Clamps, Street Light Bracket With One Coat Of Aluminium Paint Complete All As Specified And As Directed. ( Photographic Record Of The Work Will Be Maintained And Kept On Record For The Perusal Of The Accepting Officer ) 69 Servicing Of Four Pole Structure Including Checking / Tightening / Making Free For Operating Of Ab Switch, Insulators, Lighting Arrester, Changing Of Nut / Bolts If Required Including Painting Of Ryb Paint / Tape At Strip Including Preparation Of Old Painted Surfaces , Removing Dust And Other Deposited Materials By Scraping From Ht Tubular Pole Of 11 Mtr Long, Painting Of Pole With One Coat Of Black Paint Upto 1 Mtr From Bottom And Painting The Rest Of The Pole Including Cross Arms Cable Protection Pipe Clamps, Bracket With One Coat Of Aluminium Paints Complete All As Specified And Directed 70 Servicing Of Twopole Structure Including Checking / Tightening / Making Free For Operating Of Ab Switch, Insulators, Lighting Arrester, Changing Of Nut / Bolts If Required Including Preparation Of Old Painted Surfaces , Removing Dust And Other Deposited Materials By Scraping From Ht Tubular Pole Of 11 Mtr Long, Painting Of Pole With One Coat Of Black Paint Upto 1 Mtr From Bottom And Painting The Rest Of The Pole Including Cross Arms Cable Protection Pipe Clamps, Bracket With One Coat Of Aluminium Paints Complete All As Specified And Directed 71 Filtration Of Transformer Oil Of Transformers Step Down 11 Kv / 0.433 V Indoor / Outdoor Type Upto 500 Kva Capacity Installed At Different Sub Stations / Locations Using Filtration And Heating Equipment At Site By Re-Circulating Transformer Oil Heating, Dehydration And Improving Di-Electric Strength Of The Oil To Withstand Minimum 40 Kv For One Minute Including Testing Of Oil All As Specified And As Directed.Note : ( I ) Transformer Oil Test Kit And Filtration Machine Shall Be Provided By The Contractor At Site For Testing Of Oil. ( Ii ) Pvs Of The Transformer Oil Is Mandatory Before Making Any Payment. ( Iii ) Photographic Record To Be Maintained For The Work Carried Out At Site. 72 Silica Gel From The Breather Of Any Type / Model / Capacity Including Taking Down Old Unserviceable One Complete All As Specified And As Directed. 73 Supply And Filling / Topping Up New Transformer Oil Conforming To Is Specification For Transformer Upto 500 Kva Capacity Of Suitable Insulation Grade Not Less Than 40Kv Installed At Various Sub Stations Complete All As Specified And As Directed. 74 Breather Assembly Of Size 50Mm Dia, Minimum 250 Mm Long Suitable For Transformer Of Any Type / Model / Capacity Including Taking Down Old Unserviceable One Complete All As Specified And Directed 75 Oil Temperature Indicator Dial Type Having Temperature Range 0 To 120 Degree Celsius Suitable For Transformer Of Any Type / Model / Capacityincluding Taking Down Old Unserviceable One Complete All As Specified And As Directed. 76 Cutting / Clearing And Removing The Vegetable / Bush Growth Any Nature / Type Around The Electric Poles / Stays Structures / Installations / Substation., So As To Keep Clean The Area For Easy Access To Carry Out Repair / Maintenance Works On Poles Etc., Including Cutting And Removing The Creepers On Poles / Stays Etc., Removing From Site And Throwing Out At A Place Where Directed At Distance Not Exceeding 250Mtr Away Complete All As Specified And As Directed. 77 Pruning Of Tree Branches And Making Clear Ht Line To The Minimum Distance Of 30 Mtrs Span For 3 / 6 Conductors And Removing From Site And Throwing Out At A Place Where Directed At Distance Not Exceeding 250Mtr Away Complete All As Specified And As Directed.Note : Photographic Record Of Tree Pruning Will Be Maintained. 78 Supply And Errection Of Steel Tubular Swaged Poles Complete With Base Plate 8Mm Thick Welded With Pole, Finial Taper Plug, Bolt, Nut And Screws As Specified Type 410 Sp-31 ( 11.00 Mtrs Long ) Including One Coat Of Red-Oxide Zinc Chrome Primer And Two Coats Of Aluminium Paint On Surfaces Exposed To Viewincluding Numbering With Black Paint And Painting With Bituminous Paint Internally Complete And Externally For Portion Embedded In Pcccomplete All As Specified And Directed. Note : Excavation, Earth Work And Pcc Shall Be Measrued And Paid Separately. 79 Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6mm Thick Buried Directly In Ground Earth Plate Not Less Than 2.25 M Deep Below Normal Ground Level With The Top Edge Of Earth Plate At A Depth Of Not Less Than 1.5M Below Normal Ground Level, Connecting To The Galvanised Iron Earth Strip 25X4mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron And Earth Wire Protected By Provision Of Gi Medium Grade Pipe 15Mm Bore Including Provision Of Concrete Pit In Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregates With 40Mm Thick Cover Of Rcc 1:2:4 Reinforced With Xpm Weight Not Less Than 4Kg / Sqm And Frame Of Angle Iron 25X25x6mm And Hanle Of 6Mm Dia Ms Bar Made To Shape, Gi Light Grade 20Mm Bore Pipe For Watering Of Suitable Length Placed On Top Edge Of Earth Plate, Charcoal And Common Salt Filling, With Fixing Arrangement, Funnel, Wire Mesh And Earth Work In Soft / Loose Soil, Returing Filling In And Removal Of Surplus Soil To A Distance Not Exceeding 50M, Complete All As Per Plate No-3, Ssr-2009 Part-I And Connecting To Existing Earth Test Point All As Specified Or Indicated Including Testing On Completion. 80 Sch A Part-Ii ( Road Work ) 81 Repairs To Potholes Any Depth Not Exceeding 1 Sqm Each Including Sweeping Free From Dust And Mud, Or Water, Scoring Sunken Surfaces In Roads, Paths Etc., Cutting Around Edges To Atleast 25Mm In Depth, Making Good By Applying Tack Coat Of Paving Bitumen Of Grade Vg-30 At 5 Kg Per 10 Sq M, Putting In Premix Bituminous Macadam Well Rammed And Sealed With Binder 9.8 Kg / X Sqm Of Paving Bitumen Of Grade Vg-30, Blinded With 0.09 Cum Of Stone Chippings Of 6.3Mm Size And Well Rammed ( Including Supply Of Premix Macadam, Binder And Chippings ) As Specified For With Depth Of Potholes Exceeding 30Mm Complete All As Specified And As Directed. 82 Preparing Black Top Surfaces By Brushing With Wire Brushes For Removing Caked Mud, Loose Materialsetc., Sweeping With Mechanical Blower Or Brooms To Remove All Loose Dirt, Materials Etc., Complete All As Specified And As Directed. 83 Applying Evenly Using Pressure Sprayer A Priming / Tack Coat With Bituminous Primer Of Paving Bitumen Of Grade Vg-30 At 5 Kg / 10 Sqm Over Bituminous Surfacescomplete All As Specified And As Directed. 84 Bituminous Premix Semi-Dense Asphaltic Concrete ( Sdac ) , 40Mm Consolidated Thickness With 5.5% Minimum Binder Content By Weight Of Total Mix, ( Paving Bitumen Vg-30 ) And Filler Of 2% Cement, Rolled And Compacted To Required Camber And Gradient Complete Using Mechanical Paver And Rolled To A Uniform, Smooth Surface Using Tandem Vibratory Roller Complete All As Specified And As Directed. 85 Note:- 86 ( A ) Contractor Shall Quote His Rate By Considering 5.5% Bitumen Content. If It Is Less Than 5.5% By Weight Of Total Mix, The Amount Shall Be Recovered For The Less Weight Of Binder Only At The Rate Of Rs 42 / - Per Kg If Technically Acceptable. No Other Claim Whatsoever On Account Of This Will Be Allowed. 87 ( B ) No Price Adjustment Shall Be Applicable If Excess Quantity Of Binder Content Is Used / Approved In The Execution Of Work Under This Item. 88 ( C ) Cement Shall Be Used As Filler At A Minimum Of 2% By Weight Of Total Mix. In The Event Of Variation In The Mix Design In The Percentage Of Filler Content On Plus Side, Nothing Extra Shall Be Paid. 89 Preparing Road Surface Including Cleaning The Road Surface Of All Dirt, Seals, Oil, Grease And Foreign Material Etc And Applying 2.5Mm Thick Road Marking Strips ( Retro Reflective ) Of Specified Shade / Colour Using Hot Thermoplastic Material Conforming To Is-164 ( 1981 ) By Fully Automatic Thermoplastic Paint Applicator Machine Fitted With Profile Shoe, Glass Beads Dispenser Including Glass Beads, Propane Tank Heater And Profile Shoe Heater, Driven By Experienced Operator In Accordance Withmanufacturer’S Instructions All As Per Bs En 1871, Bs En 1423 And Bs En 1424 Complete As Specified And Directed. 90 Removing Old Cat Eyes And Taking On Credit And Provision Of New Duo Directional Cat Eyes ( Road Studs ) Of Size 100Mmx110mmx20mm Made Up Of Weather Resistant High Impact Polymer Conforming To Astm D4280 And Having Electronically Welded Micro Prismatic Lens With Abrasion Resistant Coating And Fixed With 2 Nos Of Polymer Shanks And Epoxy Adhesive Conforming To Is As Per Manufacturer’S Instructionscomplete All As Specified And Directed. 91 Note:- 92 Make Shall Of Cat No. Da-52 Of Dark Eye Or Cat Pt No Gpl-01-04 Make: Greens / Greenlite Or Equivalent Of Makes As Listed Here-In-After As Approved By Ge. 93 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floor And Pavings Not Exc 15Cm Thickness Below Or Above Ground Level And Removing The Same Exc 250Mm But Not Exc 500Mm Complete As Directed By The Eng-In-Charge 94 Pcc 1:4:8 Mix Type D2 ( Using 40Mm Graded Stone Aggregate ) As In Sub Base Of Flooring Of 100Mm Thickness Complete All As Specified And Directed. 95 Design Mix Cement Concrete Work In Pavement / Hard-Standing Of Flexural Strength 40 Kg / Per Square Centimetre In Field Using 400 Kg Of Cement Per Cubic Metre, With Thickness Of Concrete 25 Cm Or Lessnote - ( I ) The Design Mix Shall Be Approved By The Accepting Officer Duly Recommnded By The Ge After Carrying Out All The Initial Tests Once Recd From The Approved Lab As Per The Ps. 96 Forming Contraction / Dummy Joints65mm Deep And 10Mm Wide Fillled Withgrade A Sealing Compound Complete All As Specified And Directed. Note - ( I ) Grade ASealing Compound Shall Be Approved By The Ge Under Intimation To The Accepting Officer In Advance Before The Execution Of The Work On Ground. 97 Forming Construction Joints30mm Deep And 10Mm Wide Fillled With Grade A Sealing Compound Complete All As Specified And Directed. Note - ( I ) Grade A Sealing Compound Shall Be Approved By The Ge Under Intimation To The Accepting Officer In Advance Before The Execution Of The Work On Ground. 98 Chequered Cement Concrete Tiles ( 300 X 300 X 25 ) Mm Set, Jointed And Pointed In Neat Cement Slurry With Pigments In Floors Over 20Mm Thick Screed Bed In Cm 1:4 Bedded And Jointed Complete All As Directed By The Eng-In-Charge.Note - ( I ) Chequered Tiles Shall Be Approved By The Ge Under Intimation To The Accepting Officer In Advance Before The Execution Of The Work On Ground. 99 Precast Kerbs Or Mud Stops And The Like Including Weathering Slightly Rounded Or Chamfered Angles And Throating On Edges Of Pcc 1:2:4 Type B1 Using 12.50Mm Graded Stone Aggregate Complete All As Specified And As Directed.Note - ( I ) Precast Pcc Kerb Stones Shall Be Approved By The Ge Under Intimation To The Accepting Officer In Advance Before The Execution Of The Work On Ground. 100 Preparing Newly Plastered Or Concrete Surfaces Of Any Description Over 10Cm Width Or Girth Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint Complete All As Specified And Directed By Eng-In-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Dec-2023 Date Corrigedum Date 02-01-2024
2 02-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-01-2024
3 09-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-01-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 158500.0 /-
Tender Value
INR 89 Lakhs /-

BOQ Items

Tender Inviting Authority: COMMANDER WORKS ENGINEERS (CHENNAI)
Sl. No. Item Description
1BOQ UPLOADED ONNov 2023
2SCH "A" PART-I (EXT ELECTRICAL WORKS)
3Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth and getting out soft/loose soil for laying cables/pipes/erection of poles etc all as specified and as directed.
4All as per item No 3 above but depth exc 1.5 Mtr and not exc 3.00 Mtr all as specified and as directed.
5Removing excavated material soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
6Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as specified and as directed.
7Sand cushioning to underground cables in cable ducts by filling river Sand up to top of the cable ducts in 11 KV Sub stations or in trenches as specified in SSR Pt I complete. (Punned thickness will only be measured)
8Supply and laying Heavy duty Reinforced precast concrete cable cover ISI Marked , class HV, Type 1, flat, size (300 x l80)mm x 40mm all as specified and as directed.
9Cement concrete in foundations filling and mass concrete 1:3:6 mix Type C-2 (using 40mm graded stone aggregates)for transformer staging / pole foundation all as specified and directed.
10Cement concrete in coping of type C1 1:3:6 mix (using 20mm graded stone aggregates) for transformer staging/pole coping all as directed.
11Supply and laying in trenches/poles/wall etc HT UG Cable XLPE insulated with multistranded aluminium conductor armoured with galvanised steel wire/taps 11000 volts grade conforming to IS specifications and of following sizes including taking down the existing unserviceable cable complete all as specified and as directed. Note : - (a).Earthwork, sand cushioning, protection for cable etc as required shall be measured and paid seperately. (b) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
12HT UG Cable 3 core 95 sqmm
13HT UG Cable 3 core 120 sqmm
14HT UG Cable 3 core 185 sqmm
15HT UG Cable 3 core 240 sqmm
16Indoor termination cold shrink type joint for 11 KV (Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE /armoured heavy duty cable with aluminium conductor of following sizes complete all as specified and as directed
17HT UG Cable 3 core 95 sqmm
18HT UG Cable 3 core 120 sqmm
19HT UG Cable 3 core 185 sqmm
20HT UG Cable 3 core 240 sqmm
21Outdoor termination heat shrink type joint for 11 KV (Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE/armoured heavy duty cable with aluminium conductor of following sizes complete all as specified and as directed :-
22HT UG Cable 3 core 95 sqmm
23HT UG Cable 3 core 120 sqmm
24HT UG Cable 3 core 185 sqmm
25HT UG Cable 3 core 240 sqmm
26Straight through heat shrink type joint for 11 KV (Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE/armoured heavy duty cable with aluminium conductor of following sizes complete all as specified and as directed :-
27HT UG Cable 3 core 95 sqmm
28HT UG Cable 3 core 120 sqmm
29HT UG Cable 3 core 185 sqmm
30HT UG Cable 3 core 240 sqmm
31Polymer Switch Air Break gang operated triple pole, mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level complete with 9number polymer insulators of rating upto 200 Amp 11000 volts including necessary length of down pipe made up of galvanized iron medium grade 20mm bore with operation handle and locking arrangements including taking down the old unserviceable one complete all as specified and as directed .
32Supply and laying in trench/fixed on pole galvanized iron tubing, light grade of size 80 mm dia complete including all necessary fittings including taking down the old unservicable one complete all as specified and as directed. Note : Earthwork as required shall be measured and paid separately.
33Pin type polymer insulator, polymer, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for 11000 volts grade including taking down the old unserviceable one complete all as specified and directed.
34Disc type polymer insulators, creepage distance 120 mm, T&C and B&S end fitting type suitable for high tension over head conductors working pressure 11000 volts gradeincluding taking down the old unserviceable one complete all as specified and as directed .
35Loop type poecelain insulator, vitreous white, brown or green with over all dimension 90mm x 140mm clearance of hole 25.5mm including taking down the old unserviceable one complete all as specified and as directed.
36ACSR conductor of any size for HT over head line and jumpers on PCC/RCC/Steel pole including binding wires line connecting up etc of any size including taking down old unserviceable one complete all specified and directed .
37Anti-climbing device, spikes type, fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole of any size including taking down old unserviceable one complete all specified and directed .
38Cross-arms bracing supports clamps and back pates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot drilling holes for insert bolts in any shape or size as indicated and as directed and inclusiv of one coat of redoxide primer and one finishing coat of aluminium paint including taking down old unservicable one complete all as specified and as directed.
39Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT opf size 25x20cm size including taking down the existing unserviceable one complete all as specified and as directed.
40Polymer Lightning arrester expulsion type complete with all fitting transmission class, discharge capacity 200-800 Amp 11000 Volts rating including taking down old unserviceable one complete all as specified and as directed. (Make : Jyoti/Denson or equivalent as approved by the GE)
41Supply and laying Synthetic insulated mat of size 2.50mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size(2.00 x 1.00) Mtr including taking down old unserviceable one complete all as specified and as directed.
42Supply and laying Synthetic insulated mat of size 2.5m thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size2mx1m including taking down old unserviceable one complete all as specified and as directed.
43Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5m below normal ground level connected to GI earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers made out of GI and GI earth strip protected by 40 mm bore light grade GI pipe, watering arrangement by provision of 20mm dia GI pipe medium grade with cast iron funnel, provision of test point and connected to main control board all as shown in electrical plate No 3 of SSR Part I ncluding necessaryearth work and excavation in any type ofsoil, plain cement concrete 1:3:6,typeC1 chamber, reinforcedcement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugsincluding testing complete all as specified and as directed.
44Hardcore of broken stone boulders of guagenot exceeding 63mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surfaces using broken stones etc complete all as specified and as directed.
45Horn Gap typeFuse unit, 11000 volts grade, mounted on polymer insulators and steel frame, single pole, fixed on DP structures including taking down old unservicable one complete all as specified and directed.
46Expulsion type drop out fuse element 10amps and upto 100 amps suitable for 11 KV Horn Gap type fuse including taking down old unserviceable one complete all as specified and as directed.
47Service charges for carrying out servicing and overhauling of under mentioned capacities HT VCB by drawing out the draw-out module of the breaker, carrying out complete cleaning with clean cloth & cleaning agent, lubrication of the mechanism & greasing with high temperature molly grease,testing for smoother ON/OF operation, carrying out relay calibration of protection relay by secondary current injection methods to check trip time characteristic of relays, checking of healthiness of CTs & Pts. Checking of IR value of Interrupters, healthiness of Protection Tripping of Circuit breaker etc. Choking and servicing switchgear Interlocks and Safety Like Mechanical - 1. Positive Interlock, 2.Negative Interlock, 3. Spring Discharge Interlock, 4. Padlocks, 5. Key Interlocking 6. Safety Roll in Stop, 7. Safety Roll - out Stop,8. Rating Interference Interlock. Electrical - Interlock Switches) Checking of Electrical operations of the breaker for ON/OFF & Trip operation for Incomer and Outgoing including submission of service & test reports. Make : Crompton Greaves. Note :(i)Servicing of the VCB to be done by authorised service provider of the manufacturer as approved by the Accepting Officer. (ii) Proper photographic record will be maintained with dates of work carried out duly signed by the Eng-in-Charge. (iii) Unit rate quoted is deemed to be inclusive of spares/ lubricants other than the spares mentioned underitem No 44.00 to 51.00 (iv) The rate quoted is deemed to be inclusive of labour charges for fixing taking down and renewal of defective spares.
48Vacum circuit breaker (VCB) Amps:400A
49Vacum circuit breaker (VCB) 630 Amps to 800A
50Supply and replacement of following items of400 to 800 Ampere capacity, 11 KV, 3 phase, 50 Hz,HT VCB of any quanity during servicing of VCB as stated in Item No 31 above including taking down old unservicable one complete all as specified and as directed.
51Replacement & fitting of Charging Gear complete
52Replacement & fitting of Rack in and out gear complete
53Replacement & fitting of Rack in and out mechanism complete. Make : ABB or equivalent
54Replacement & fitting of Spring charging mechanism complete
55Replacement & fitting of 630A Vacuum Interrupter complete. Make: CG or equivalent
56Replacement & fitting of Tripping Relay complete. Make: Ashida AVAJH13 or equivalent
57Replacement & fitting of Tripping coil complete. Make: CG or equivalent
58Replacement & fitting of over current earth fault relay, Phase and earth current input 1/5A, ICE version. Make : CG or equivalent
59Indicating lamp of any type / model / capacity in HT VCB/SFU panels including taking down old unserviceable one complete all as specified and as directed.Make: Siemens or equivalent
60Multifunction meter with RS port of any type / model / capacity in HT VCB/SFU panels including taking down old unserviceable one complete all as specified and as directed.Make : L&T 4410 Series / ABB / Selec as approved by the GE
61TNC switch of any type / model / capacity in HT VCB/SFU panels including taking down old unserviceable one complete all as specified and as directed.Make: Kaycee
62Heating element 250 Watts of any type / model / capacity in HT VCB/SFU panels including taking down old unserviceable one complete all as specified and as directed. Make : RS PRO or equivalent
63Finding fault ofHT XLPE UG Cable aluminium conductor armoured of cable size 95 Sqmm to 240 Sqmm by fault locater including taking out cable from trenches/poles/structure and relaying after fault rectification complete all as specified and directed. Note: (i)Quoted Rate is deemed to be included of charges of HT fault Locater and the complete Earth Work involved. (ii)The work should be completed within 12 hrs, (iii)Jointing Kit will be measured and paid separately under relevant Item.
64Service charges forcarrying out complete servicing of AB Switch bylubrication of the mechanism & greasing with petroleum jelly complete all as specified and as directed.Note: Minimum spares /lubricants and tools required for the jobshould beincluded in the coated rates.
65Labour only for restraining of ACSR conductor from pole to pole 3 conductors with maintain minimum sag as per HT specification all as specified and as directed by Engr-in-Charge. Note :- Minimum spares and tools required for the job should be included in the coated rates.
66HT 11 KV Phase / Line seperator suitable for fixing OH ACSR conductor, 11 KV range including taking down old unserviceable one complete all as specified and as directed.
67Painting outer surfaces of transformer of capacity above 100KVA, any type / make / model, pole or plinth mounted, installed at various sub stations with one coat of synthetic enamel paint of approved shade including cleaning the old painted surfaces and writing SM / MES numbers, capacity, make, date of oil testing etc., complete all as specified and as directed. (Photographic record of the work will be maintained and kept on record for the perusal of the Accepting Officer)
68Preparation of old painted surfaces, removing dust and other deposited materials by scraping from HT/LT tubular pole 11mtr long, painting of pole with one coat of black paint upto 1 Mtr from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, street light bracket with one coat of aluminium paint complete all as specified and as directed. (Photographic record of the work will be maintained and kept on record for the perusal of the Accepting Officer)
69Servicing of four pole structure including checking / tightening / making free for operating of AB switch, insulators, lighting arrester, changing of nut/bolts if required including painting of RYB paint/tape at strip including preparation of old painted surfaces ,removing dust and other deposited materials by scraping from HT tubular pole of 11 Mtr long, painting of pole with one coat of black paint upto 1 Mtr from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, bracket with one coat of aluminium paints complete all as specified and directed
70Servicing of twopole structure including checking/ tightening/making free for operating of AB switch, insulators, lighting arrester, changing of nut/bolts if required including preparation of old painted surfaces ,removing dust and other deposited materials by scraping from HT tubular pole of 11 Mtr long, painting of pole with one coat of black paint upto 1 Mtr from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, bracket with one coat of aluminium paints complete all as specified and directed
71Filtration of transformer oil of transformers step down 11 KV/ 0.433 V indoor / outdoor type upto 500 KVA capacity installed at different sub stations/locations using filtration and heating equipment at site by re-circulating transformer oil heating, dehydration and improving di-electric strength of the oil to withstand minimum 40 KV for one minute including testing of oil all as specified and as directed. Note : (i)Transformer oil test kit and filtration machine shall be provided by the contractor at site for testing of oil. (ii) PVs of the Transformer oil is mandatory before making any payment. (iii)Photographic record to be maintained for the work carried out at site.
72Silica gel from the breather of any type/model/capacity including taking down old unserviceable one complete all as specified and as directed.
73Supply and filling / topping up new transformer oil conforming to IS specification for transformer upto 500 KVA capacity of suitable insulation grade not less than 40KV installed at various sub stations complete all as specified and as directed.
74Breather assembly of size 50mm dia, minimum 250 mm long suitable for transformer of any type/model/capacity including taking down old unserviceable one complete all as specified and directed
75Oil temperature indicator dial type having temperature range 0 to 120 degree celsius suitable for transformer of any type / model / capacityincluding taking down old unserviceable one complete all as specified and as directed.
76Cutting/clearing and removing the vegetable/bush growth any nature/type around the electric poles/stays structures/installations / substation., so as to keep clean the area for easy access to carry out repair/maintenance works on poles etc., including cutting and removing the creepers on poles/stays etc., removing from site and throwing out at a place where directed at distance not exceeding 250mtr away complete all as specified and as directed.
77Pruning of tree branches and making clear HT line to the minimum distance of 30 mtrs span for 3/6 conductors and removing from site and throwing out at a place where directed at distance not exceeding 250mtr away complete all as specified and as directed.Note : Photographic record of tree pruning will be maintained.
78Supply and errection of Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (11.00 mtrs long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to viewincluding numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCCcomplete all as specified and directed. Note : Excavation, earth work and PCC shall be measrued and paid separately.
79Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5m below normal ground level, connecting to the Galvanised iron earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM weight not less than 4kg/sqm and frame of angle iron 25x25x6mm and hanle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returing filling in and removal of surplus soil to a distance not exceeding 50m, complete all as per plate No-3, SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion.
80SCH "A" PART-II (ROAD WORK)
81Repairs to potholes any depth not exceeding 1 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths etc.,cutting around edges to atleast 25mm in depth, making good by applying tack coat of paving bitumen of Grade VG-30 at 5 kg per 10 sq m, putting in premix bituminous macadam well rammed and sealed with binder 9.8 Kg / X Sqm of paving Bitumen of grade VG-30, blinded with 0.09 Cum of stone chippings of 6.3mm size and well rammed (including supply of premix macadam, binder and chippings) as specified for with depth of potholes exceeding 30mm complete all as specified and as directed.
82Preparing black top surfaces by brushing with wire brushes for removing caked mud, loose materialsetc., sweeping with mechanical blower or brooms to remove all loose dirt, materials etc., complete all as specified and as directed.
83Applying evenly using pressure sprayer a priming / tack coat with bituminous primer of paving bitumen of Grade VG-30 at 5 kg / 10 Sqm over bituminous surfacescomplete all as specified and as directed.
84Bituminous premix semi-dense asphaltic concrete (SDAC), 40mm consolidated thickness with 5.5% minimum binder content by weight of total mix, (paving bitumen VG-30) and filler of 2% cement, rolled and compacted to required camber and gradient complete using mechanical paver and rolled to a uniform, smooth surface using Tandem vibratory roller complete all as specified and as directed.
85Note:-
86(a) Contractor shall quote his rate by considering 5.5% bitumen content. If it is less than 5.5% by weight of total mix, the amount shall be recovered for the less weight of binder only at the rate of Rs 42/- per Kg if technically acceptable. No other claim whatsoever on account of this will be allowed.
87(b) No price adjustment shall be applicable if excess quantity of binder content is used / approved in the execution of work under this item.
88(c) Cement shall be used as filler at a minimum of 2% by weight of total mix. In the event of variation in the mix design in the percentage of filler content on plus side, nothing extra shall be paid.
89Preparing road surface including cleaning the road surface of all dirt, seals, oil, grease and foreign material etc and applying 2.5mm thick road marking strips (Retro reflective) of specified shade/colour using hot thermoplastic material conforming to IS-164(1981) by fully automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser including glass beads, propane tank heater and profile shoe heater, driven by experienced operator in accordance withmanufacturer’s instructions all as per BS EN 1871, BS EN 1423 and BS EN 1424 complete as specified and directed.
90Removing old CAT eyes and taking on credit and provision of new Duo directional CAT eyes (Road studs) of size 100mmx110mmx20mm made up of weather resistant high impact polymer conforming to ASTM D4280 and having electronically welded micro prismatic lens with abrasion resistant coating and fixed with 2 Nos of polymer shanks and epoxy adhesive conforming to IS as per manufacturer’s instructionscomplete all as specified and directed.
91Note:-
92Make shall of Cat No. DA-52 of Dark Eye or Cat Pt No GPL-01-04 Make: GREENS/ GREENLITE or equivalent of makes as listed here-in-after as approved by GE.
93Demolition of Cement concrete (Unreinforced) in ground floor and pavings not exc 15cm thickness below or above ground Level and removing the same exc 250mm but not exc 500mm complete as directed by the Eng-in-Charge
94PCC 1:4:8 mix type D2 (using 40mm graded stone aggregate) as in sub base of flooring of 100mm thickness complete all as specified and directed.
95Design mix Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, with thickness of concrete 25 cm or lessNote - (i)The design mix shall be approved by the Accepting Officer duly recommnded by the GE after carrying out all the initial tests once recd from the approved lab as per the PS.
96Forming Contraction / Dummy joints65mm deep and 10mm wide fillled withGrade "A" Sealing Compound complete all as specified and directed. Note - (i)Grade "A"sealing compound shall be approved by the GE under intimation to the Accepting Officer in advance before the execution of the work on ground.
97Forming Construction joints30mm deep and 10mm wide fillled with Grade "A" Sealing Compound complete all as specified and directed. Note - (i)Grade "A" sealing compound shall be approved by the GE under intimation to the Accepting Officer in advance before the execution of the work on ground.
98Chequered Cement Concrete Tiles (300 x 300 x 25) mm set, jointed and pointed in neat cement slurry with pigments in floors over 20mm thick screed bed in CM 1:4 bedded and jointed complete all as directed by the Eng-in-Charge.Note - (i) Chequered tiles shall be approved by the GE under intimation to the Accepting Officer in advance before the execution of the work on ground.
99Precast Kerbs or mud stops and the like including weathering slightly rounded or chamfered angles and throating on edges of PCC 1:2:4 type B1 using 12.50mm graded stone aggregate complete all as specified and as directed.Note - (i) Precast PCC Kerb stones shall be approved by the GE under intimation to the Accepting Officer in advance before the execution of the work on ground.
100Preparing newly plastered or concrete Surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Eng-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail