Tender For Repair / Maintenance Of Water Supply Network System In Technical Area At Afs Under Ge (Af) Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Water Supply Network System In Technical Area At Afs Under Ge (Af) Pathankot. Submission Date for this Tender is 02-01-2024. Water Supply Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41063480
Corrigendum : Tender For Repair / Maintenance Of Water Supply Network System In Technical Area At Afs Under Ge (Af) Pathankot
Open Tender
Indian
Punjab
pathankot
02-01-2024

Tender Details

Tender For Repair / Maintenance Of Water Supply Network System In Technical Area At Afs Under Ge ( Af ) Pathankot; 1 Checking And Shortout The Faulty Pipe Line Against Low Pressue / Leakage / Broken Pipe Line Including Repair, Maint And Making Leak Proof Gi / Ci / Di Water Supply Pipe Lines / Valves After Rectifying The Defects Of The Water Supply Items In Technical Area Complete With Clips, Wall Hooks, Wooden Plugs, Cutting, Screwing And For Making Forged Bends On Piping As Required And Other Similar Items / Fittings Etc Such As Joints, Sluice Valves / Gate Valves, Bends, Elbows, Tees, Connectors, Backnuts, Diminishing Pieces, Caps, Plugs And Unions, Etc And Fixing Complete. Complete All As Specified And Directed By Engineer-In-Charge ( Note :- ( I ) Each Job Is Assessed For One No Fitter General Mechanic Alongwith A Helper Each Day. ( Ii ) Minor Excavation Required For Repair Work For Upto The Length Of 1Mtr And Depth Of 1 Mtr And Width Of 0.6 Mtr Including Retrurning Filling And Removal Of Surplus Soil Is Deemed To Be Included In Quoted Rates ( Iii ) Material Such As Joints, Valves Of Any Type, Ci Fittings Will Be Measured And Paid Seperately Under Respective Item Of Schedule, Cost Of Taking Out, Fixing Only And Faulty Items And Any Material Other That Mentioned Required For Fault Rectification Is Deemed To Be Included In Quoted Rates. ( Iv ) Any T&P Required For Execution Of Job Is To Be Provided By Contractor And Is Deemed To Be Included In Quoted Rates. 2 M & L For Construction Of Valve Pit In Repair Of Internal Size 900X900x1000mm Of Solid Block Masonry In Cement Mortar 1:6 And Applying 15Mm Thick Plastering To Internal And Exposed External Surfaces In Cement Mortar 1:4, Mixed With Water Proofing Compound @ 3% By Weight Of Cement, Pcc 1:3:6 Type C-2 In Foundation, Pcc 1:2:4 Type B-1 In Floor & Coping Of Valve Pit And Pit Cover Made Out Of 3Mm Thick Mild Steel Sheet With 40X40x5mm Angle Iron Frame And 40X5mm Fi Hold Fast Embedded In Pcc By Applying Two Coats Of Synthetic Enamel Paint Blue Over A Coat Of Red Oxide Primer For 80Mm To 150Mm Dia Of Valve Cleaning And Filling Up Earth Or Sludge And Removing The Same With Other Demolished Material To A Distance N.Exc 50M And Deposited As Directed By Engineer-In Charge. The Work Will Be Carried Out With In Distance 1Km From Road. 3 All As Per Item No.2 Above But Pit Of Internal Size Is 610X610x690mm Complete All As Specified And Directed. 4 Taking Down 80 Mm Bore Diaci / Di Pipe Including Connected Items And Connections Complete All As Specified And Directed By Engr-In-Charge 5 All As Per Item No.4 Above But 100Mm Bore Complete All As Specified And Directed. 6 All As Per Item No.4 Above But 150Mm Bore Complete All As Specified And Directed. 7 Refixing Ci / Di Pipei Tubing Of 80Mm Bore Size With And Including All Fitting And Fixtures Laid In Trenches Complete All As Specified And Directed By Engr-In-Charge. 8 All As Per Item No.7 Above But 100Mm Bore Complete All As Specified And Directed. 9 All As Per Item No.7 Above But 150Mm Bore Complete All As Specified And Directed. 10 Supply And Laying Pipe Ductile Iron , Class “K-7” , 150 Mm ( 6” ) Dia Including Jointing Material, Fittings Etc All As Required At Site Complete All As Specified And Directed By Engr-In-Charge 11 Supply And Laying Pipe Ductile Iron , Class “K-7” , 100 Mm ( 4” ) Dia Including Jointing Material, Fittings Etc All As Required At Site Complete All As Specified And Directed By Engr-In-Charge 12 Material & Labour For Cleaning Of Rcc Over Head Water Tank Using Alum Water, Height Up To 15 Mtr Including Pumping Out Balance Water, Taking Out Dirty Water Stone Pieces And Sludge Etc By Usnig Buckets, Cleaning And Removing All Dirt And Plankton Completely From Wall And Flour Of The Tank And From Mouths Of Inlet And Outlet Pipes Etc And By Rubbing With Wire Brushes And Removing All Waste To Distance Not Exc 50 Mtr And Depositing Where Directed Cleaning The Tank With Fresh Water And Removing Dirty Water Out Of The Tank Writing On Tank Date Of Cleaning On External Surface With Synthetic Enamel Paint After Removing Old Date Complete All As Specified And Directed By Engr-In-Charge For The Following Capacity ( Note - The Cleaning Of Over Head Tank Will Be Planning Such As Time That There Should No Hindrence Occure Of Water Distribution System ) ( A ) 50000 Gallons Capacity 13 All As Per Item No.12 Above But 25000 Gallons Capacity Complete All As Specified And Directed. 14 Supply & Fixing Fasd Starter Panel Suitable For Three Phase 40 Hp Submersible Pump With Over Load Relay Having Range Of 36 To 60 Amps, Coil Voltage 380 To 415 Volts, Including Contactors, Timers, Single Phase Preventer, Voltmeter / Ammeter Of Suitable Capacity Prewired Incl Taking Down The Existing Unserviceable Starter Complete All As Specified And Directed By Engr-In-Charge. 15 Supply & Fixing Fasd Starter Panel Suitable For Three Phase 30 Hp Submersible Pump With Over Load Relay Having Range Of 30 To 50 Amps, Coil Voltage 380 To 415 Volts, Including Contactors, Timers, Single Phase Preventer, Voltmeter / Ammeter Of Suitable Capacity Prewired Incl Taking Down The Existing Unserviceable Starter Complete All As Specified And Directed By Engr-In-Charge. 16 Excavation In Trenches Not Exc 1.5 M Wide And Not Exc 1.5M Deep For Foundation Etc Or For Laying Of Pipes Etcand Getting Out In Soft / Loose Soil, Complete All As Specified And Directed By Engr-In-Charge. 17 Returning Filling In Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25Cm In Soft / Loose Soil, Complete All As Specified And Directed By Engr-In-Charge. 18 Removing Excavated Soil To A Distance Exc 50M And Not Exc 250 M And Depositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point , Complete All As Specified And Directed By Engr-In-Charge. 19 Taking Up Or Downsteel Tubingof Size 15Mm Bore Pipe Including Connected Items And Connections Complete All As Specified And Directed By Engr-In-Charge. 20 All As Per Item No.19 Above But 20Mm Bore Complete All As Specified And Directed. 21 All As Per Item No.19 Above But 25Mm Bore Complete All As Specified And Directed. 22 All As Per Item No.19 Above But 40 / 50Mm Bore Complete All As Specified And Directed. 23 All As Per Item No.19 Above But 80Mm Bore Complete All As Specified And Directed. 24 All As Per Item No 19 Above But 100Mm Bore Complete All As Specified And Directed. 25 Relaying Gi Tubing 15 Mm Bore Size With And Including All Fitting And Fixtures Laid In Trenches Complete All As Specified And Directed By Engr-In-Charge. 26 All As Per Item No.25 Above But 20Mm Bore Complete All As Specified And Directed. 27 All As Per Item No.25 Above But 25Mm Bore Complete All As Specified And Directed. 28 All As Per Item No.25 Above But 40 / 50Mm Bore Complete All As Specified And Directed. 29 All As Per Item No.25 Above But 80Mm Bore Complete All As Specified And Directed. 30 All As Per Item No.25 Above But 100Mm Bore Complete All As Specified And Directed. 31 Supply & Fixing 15Mm Bore Gi Tubing, Medium Grade With And Including All Fitting And Fixtures Laid In Trenches Complete All As Specified And Directed By Engr-In-Charge. 32 All As Per Item No.31 Above But 20Mm Bore Complete All As Specified And Directed. 33 All As Per Item No.31 Above But 25Mm Bore Complete All As Specified And Directed. 34 All As Per Item No.31 Above But 40Mm Bore Complete All As Specified And Directed. 35 All As Per Item No.31 Above But 50Mm Bore Complete All As Specified And Directed. 36 All As Per Item No.31 Above But 80Mm Bore Complete All As Specified And Directed. 37 All As Per Item No.31 Above But 100Mm Bore Complete All As Specified And Directed. 38 Supply And Lower Submersible Copper Cable 16 Sqmm, 3 Core, 1100 Voltscomplete All As Specified And Directed By Engineer-In-Charge 39 Supply And Lower Submersible Copper Cable 25 Sqmm, 3 Core, 1100 Volts Complete All As Specified And Directed By Engineer-In-Charge 40 Cleaning Of Pit Chamber Of Domestic Area Including Painting Ms Pit Cover Complete All As Directed By Engr In Charge. ( Note : Location Of Water Chambe Will Be Decided By Engr In Charge. ) 41 M& Lcutting Of Bushesgrassand Cleaning Area With Help Of Cutting Tools And Dumping All Waste Materialto Suitable Placecomplete All As Specified And Directed By Engineer-In-Charge 42 Taking Down Old Unserviceable Water Level Indicator Assembly, Consisting Of Mild Steel Level Indicator With Superior Quality Steel Wire Of Suitable Length, Balancing Weight, A Set Of Pulley Duly Grouted In Wall Of Rcc Over Headtank With Ms Support, Brass / Copper Float Valve, Including Painting Of Ms Scale With Synthetic Enamel Paint And Marking The Required Numbers / Scale In Red / Black Colour Complete All As Specified And Directed By The Engineer In Charge 43 Painting Of Ms Ladder Fixed On Water Tank With Recommendedcolour With Paints Two Coat Over A Coat Of Red Oxide Complete All As Specified And Directed 44 Supply And Filling Calcium Hypochlorites Dry Free Flowing And Free From Lumps Should Not Induce Substance Beyond Acceptable Limit As Given In Is 10500 ( 2012 ) In Treated And Disinfected Water Available Chlorine Content 65% Minimum By Mass, Stability 1 / 15 Maximum Loss Of Chloride On Basis Of Available Chloride, Particle Size 99.5 % Wise, Water Insoluble Matter 6% Max, Calcium Hydroxide 4% Max, Sodium Chloride 15% Max As Approved By E-In-C Branch. 45 Supply And Replacement Of Union Nut Pvc For Chlorine Dosing System Matching With Existing Sample Complete All As Specified And Directed By Engineer In Charge Complete 46 Supply And Replacement Ofreducer For Dosing Pump All Asper Existing Sample Complete All As Specified And Directed By Engineer –In-Charge. 47 S&F In Replacement Of Pumptube Of Dosing Pump Matching With Existing Sample Complete All As Directed And Specified By Engr-In- Charge . 48 Supply And Replacement Of Motor Agitator Including Shaft Blades Etc For Chlorine Dosing System Matching With Existing Sample Complete All As Directed And Specified By Engineer-In-Charge 49 S & F In Replacement High Density Polyethylene Pipe ( Hdpe ) Having Pressure Rating 6Kgf / Cm2 Fixed Complete To Walls, Ceilings Or In Floors From Dosing Pump To Chlorine Feeding Point Matching With Existing Sample Complete All As Specified And Directed By Engineer-In-Charge 50 S&F In Replacement Non Return Valve Suitable For Dosing System Matching With Existing Sample Complete All As Specified And Directed By Engr-In-Charge. 51 Material & Labour For Cement Concrete For Repair Of Broken Valve Pits Type C-2 Using 40Mm Graded Aggregate Ratio 1:3:6 Complete All As Specified And Directed By Engr-In-Charge. 52 Replacement Of Spindle Brass / Stainless Steel With Wheel Of Sluice Valve Of 80Mm Dia Complete All As Specified And Directed By Engr-In-Charge. 53 All As Per Item No. 52 Above But 100Mm Dia Complete All As Specified And Directed By Engr-In-Charge. 54 All As Per Item No. 52 Above But 150Mm Dia Complete All As Specified And Directed By Engr-In-Charge. 55 Material & Labour For 150 Mm Bore Sluice Valve Type Pn-1 Double Flanged Cost Iron Type With Brass Spindle And Iron Wheel And 16 Mm Dia Iron Nuts, Bolts & Washers And Rubber Insertion Sheet Conforming To Is Specification Complete All As Specified And Directed By Engr-In-Charge. 56 Material & Labour For 100 Mm Bore Sluice Valve Type Pn-1 Double Flanged Cast Iron Type With Brass Spindle And Iron Wheel And 16 Mm Dia Iron Nuts, Bolts & Washers And Rubber Insertion Sheet Conforming To Is Specification Complete All As Specified And Directed By Engr-In-Charge. 57 Material & Labour For 80 Mm Bore Sluice Valve Type Pn-1 Double Flanged Cast Iron Type With Brass Spindle And Iron Wheel And 16 Mm Dia Iron Nuts, Bolts & Washers And Rubber Insertion Sheet Conforming To Is Specification Complete All As Specified And Directed By Engr-In-Charge. 58 Material & Labour For 150 Mm Bore Non Return Valve Type Pn-1 Double Flanged Cast Iron Type With Brass Spindle And Iron Wheel And 16 Mm Dia Iron Nuts, Bolts & Washers And Rubber Insertion Sheet Conforming To Is Specification Complete All As Specified And Directed By Engr-In-Charge. 59 Material & Labour For Run Lead Joint To 150 Mm Bore Complete And Complete All As Specified And Directed By Engr-In-Charge. 60 Material & Labour For Run Lead Joint To 100 Mm Bore Complete And Complete All As Specified And Directed By Engr-In-Charge. 61 Material & Labour For Run Lead Joint To 80 Mm Bore Complete And Complete All As Specified And Directed By Engr-In-Charge. 62 Material & Labour For Cutting Of Cast Iron Pipe 80 Mm Dia To Required Length Before Laying Pipe Complete All As Specified And Directed By Engr-In-Charge. 63 Material & Labour For Cutting Of Cast Iron Pipe 100 Mm Dia To Required Length Before Laying Pipe Complete All As Specified And Directed By Engr-In-Charge. 64 Material & Labour For Cutting Of Cast Iron Pipe 150 Mm Dia To Required Length Before Laying Pipe Complete All As Specified And Directed By Engr-In-Charge. 65 Supply And Fixing Of 15Mm Gi Fittings I.E Elbow Complete All As Specified And Directed By Engr-In-Charge. 66 All As Per Item No. 65 Above But 20Mm Elbow Complete All As Specified And Directed By Engr-In-Charge. 67 All As Per Item No. 65 Above But 25Mm Elbow Complete All As Specified And Directed By Engr-In-Charge. 68 All As Per Item No. 65 Above But 40Mm Elbow Complete All As Specified And Directed By Engr-In-Charge. 69 All As Per Item No. 65 Above But 50Mm Elbow Complete All As Specified And Directed By Engr-In-Charge. 70 Supply And Fixing For 15Mm Dia Gi Fittings I.E Socketcomplete All As Specified And Directed By Engr-In-Charge. 71 All As Per Item No. 70 Above But 20Mm Socket Complete All As Specified And Directed By Engr-In-Charge. 72 All As Per Item No. 70 Above But 25Mm Socket Complete All As Specified And Directed By Engr-In-Charge. 73 All As Per Item No. 70 Above But 40Mm Socket Complete All As Specified And Directed By Engr-In-Charge. 74 All As Per Item No. 70 Above But 50Mm Socket Complete All As Specified And Directed By Engr-In-Charge. 75 Supply And Fixing Of 15Mm Dia Gi Fittings I.E Union Complete All As Specified And Directed By Engr-In-Charge. 76 All As Per Item No. 75 Above But 20Mm Union Complete All As Specified And Directed By Engr-In-Charge. 77 All As Per Item No. 75 Above But 25Mm Union Complete All As Specified And Directed By Engr-In-Charge. 78 All As Per Item No. 75 Above But 40Mm Union Complete All As Specified And Directed By Engr-In-Charge. 79 All As Per Item No. 75 Above But 50Mm Union Complete All As Specified And Directed By Engr-In-Charge. 80 Supply And Fixing Of 15Mm Dia Gi Fittings I.E Nipplecomplete All As Specified And Directed By Engr-In-Charge. 81 All As Per Item No. 80 Above But 20Mm Nipple Complete All As Specified And Directed By Engr-In-Charge. 82 All As Per Item No. 80 Above But 25Mm Nipple Complete All As Specified And Directed By Engr-In-Charge. 83 All As Per Item No. 80 Above But 40Mm Nipple Complete All As Specified And Directed By Engr-In-Charge. 84 Material & Labour For Brick Work With Subclass Old Sized ‘B’ Bricks, Straight Or Curved On Plan Exc 6M Mean Radius, Built In Cement Mortar Of Ratio 1:6 For Repair Of Broken Valve Pits Complete All As Specified And Directed By Engr-In-Charge. 85 Material & Labourfor Cement Plastering In Cm 1:4, 10 Mm Thick On Brickmasonery Surfaces Incl Finishing The Surfaces Even And Smooth W / Out Using Extra Cement Complete All As Specified And Directed By Engr-In-Charge. 86 Material & Labour For Cross Arms Bracing Support Clamps And Back Plates Fabricated Iron Structural Steel Section Incl Nuts, Bolts, Washers, Welding , Bending Cold Or Hot Drilling Holes For Bolts In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat And One Under Coat And One Finishing Coat Of Alluminium Paint Complete All As Specified And Directed By Engr-In-Charge. 87 Material & Labour For Cast Iron Bends ( Any Type Radius And Angle ) Taper Any Type ( Straight ) Bend Increasing Per Decreasing Or Double Socket Etc Tee Peces, Single Branch Y Junction Double Branch, Coller, Kg Capacity And Plugs For 80 Mm Bore To 150 Mm Bore Ci Pipe Conforming To Is-1538-1976 Complete All As Specified And Directed By Engr-In-Charge. 88 Material & Labour For Breaking Road, Pavement, Hard Standing, Tiles Of Any Type, Including Excavation Of Subbase, Soil Upto The Depth Of 0.60 Mtr And Width 0.45 Mtr By Mechanical Means For Fault Finding In Water Pipe Lines And Including Making Good To The Disturbed Surfaces Matching With Existing After Rectification Of Fault Including Removal Of Surplus Material To Nearby Dumping Point Complete All As Specified And Directed By Engr-In-Charge. 89 Supply And Fixing In Replacement Thermal Over Load Relay Suitable For Oil Immersed Star Delta Starter For Submersible Pumps Of Rating 15 To 25 Hp Matching With Existing Sample Including Connections With Existing Star Delta Starters Complete All As Specified And Directed By Engr-In-Charge. 90 Supply And Fixing In Replacement Thermal Over Load Relay Suitable For Oil Immersed Star Delta Starter For Submersible Pumps Of Rating 30 To 40 Hp Matching With Existing Sample Including Connection With Existing Star Delta Starter Complete All As Specified And Directed By Engr-In-Charge. 91 Supply And Fixing In Replacement Single Phase Prevention Relay Suitable For Star Delta Starters, Of Capacity Upto 40 Hp, With Auto, Mannual And Bypass Operation, With Time Delay Setting Including Wiring And Connection With Existing Star Delta Starter Complete All As Specified And Directed By Engr-In-Charge. 92 Supply And Fixing In Replacement Electronic Timer Suitable For Star Delta Starters, Having Coil Voltage 380 To 415 Volts, With Time Delay 3 To 30 Seconds, Complete Including Wiring And Connections With Existing Star Delta Starter Complete All As Specified And Directed By Engr-In-Charge. 93 Material & Labour For Strip Opening Of Pump Of Any Type Of Submersible / Centrifugal Motor 15 Hp To 40 Hp Of Any Stage / Size / Make And Re Assembling Including Replacement Of Defective Items And Reassembling Complete After Repair Including Testing At Workshop Complete All As Specified And Directed By Engr-In-Charge. ( Note Major Defective Items Replaced Will Be Measured And Paid Seperately Under Respective Item Of Schedule, Cost Of Items Not Mentioned In Schedule And To Be Replaced Is Deemed To Be Included In Quoted Rates. ) 94 Supply Only Following Items To Be Fixed Under Items Above:- ( A ) Pump Shaft Stainless Steel For 20To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 95 All As Per Item No. 94 Above Butimpeller Bronze / Gun Metal For 20 To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 96 All As Per Item No. 94 Above Butci Neck Ring For 20 To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 97 All As Per Item No. 94 Above Butgun Metal Intermediate Bush For 20 To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 98 All As Per Item No. 94 Above Butsuction / Discharge Bush For 20 To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 99 All As Per Item No. 94 Above Butci Bowl For Pump For 20 To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 100 All As Per Item No. 94 Above But Middle Distance Bush Of Stain Less Steel For 20 To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 101 All As Per Item No. 94 Above Butshaft Coupling Stain Less Steel For 20 To 40 Hp Pump Matching With Existing Size Complete All As Specified And Directed By Engr-In-Charge. 102 Taking Out Submersible Pump Set 20 Hp To 40 Hp From The Bore Well In Any Depth Complete With Column Pipe And Other Connected Part And Lowering The Same After Repair Of The Pump Set Including Checking Of Pump Set For Faults Before Shifting To Workshop Complete All As Specified And Directed By Engr-In-Charge. ( Note: Required T&P For Above Work And Transportation To Workshop And Taking Back Is Deemed To Be Included In Quoted Rates ) 103 Material & Labour For Strip Opening 3 Phase 20 To 40 Hp Capacity Ac Submersible Motor Taking Out Burnt Winding Coils Complete And Rewinding With Insulated Water Proof Winding Wire Matching With Existing Size Including Seal Pvc ( Water Proof Compound ) Reassembling The Motor And Testing At Workshop Complete All As Specified And Directed By Engr-In-Charge. ( Note: Insulation To Wires, Windings, Varnishing, And Other Items Required For Rewinding And Making Motor Water Proof Not Mentioned In Description And T&P Required For This Job Is Deemed To Be Included In Quoted Rates. ) 104 Supply And Replacement Thrust Plate Matching With Existing Size Suitable For 20 To 40 Hp Electric Motor Complete All As Specified And Directed By Engineer-In-Charge. 105 Supply & Fixing In Replacement Stud With Nuts Including Spring Washer Matching With Existing Complete All As Specified And Directed By Engr-In-Charge. 106 Supply & Fixing In Replacement Water Seal Suitable For Submersible Motor Matching With Existing Complete All As Specified And Directed By Engr-In-Charge. 107 Supply & Fixing Of 50Mm Bore Sizes Ofgate Valve Gun Metal Screwed Down High Pressure With Crutch With Or Butter Fly Handle Screwed Booth Ends For Pip Complete All As Specified And Directed By Engr-In-Charge. 108 All As Per Item No. 107 Above But40mm Bore Complete All As Specified And Directed By Engr-In-Charge. 109 All As Per Item No. 107 Above But25mm Bore Complete All As Specified And Directed By Engr-In-Charge. 110 All As Per Item No. 107 Above But20mm Bore Complete All As Specified And Directed By Engr-In-Charge. 111 All As Per Item No. 107 Above But15mm Bore Complete All As Specified And Directed By Engr-In-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Dec-2023 Corrigendum Other 02-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work : REPAIR / MAINT OF WATER SUPPLY NETWORK SYSTEM IN TECHNICAL AREA AT AFS UNDER GE (AF) PATHANKOT
Sl. No. Item Description
1Checking and shortout the faulty pipe line against low pressue/leakage/ broken pipe line including Repair, maint and making leak proof GI/CI/DI water supply pipe lines/valves after rectifying the defects of the water supply items in TECHNICAL AREA complete with clips, wall hooks, wooden plugs, cutting, screwing and for making forged bends on piping as required and other similar items/fittings etc such as joints, sluice valves/gate valves, bends, elbows, tees, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc and fixing complete. complete all as specified and directed by Engineer-in-Charge (Note :- (i) Each job is assessed for one no fitter general mechanic alongwith a helper each day. (ii) Minor excavation required for repair work for upto the length of 1mtr and depth of 1 mtr and width of 0.6 mtr including retrurning filling and removal of surplus soil is deemed to be included in quoted rates (iii) Material such as joints, valves of any type, CI fittings will be measured and paid seperately under respective item of schedule, cost of taking out, fixing only and faulty items and any material other that mentioned required for fault rectification is deemed to be included in quoted rates. (iv) Any T&P required for execution of job is to be provided by contractor and is deemed to be included in quoted rates.
2M & L for construction of valve pit in repair of internal size 900x900x1000mm of solid block masonry in cement mortar 1:6 and applying 15mm thick plastering to internal and exposed external surfaces in cement mortar 1:4, mixed with water proofing compound @ 3% by weight of cement, PCC 1:3:6 type C-2 in foundation, PCC 1:2:4 type B-1 in floor & coping of valve pit and pit cover made out of 3mm thick mild steel sheet with 40x40x5mm angle iron frame and 40x5mm FI hold fast embedded in PCC by applying two coats of synthetic enamel paint blue over a coat of red oxide primer for 80mm to 150mm dia of valve cleaning and filling up earth or sludge and removing the same with other demolished material to a distance n.exc 50m and deposited as directed by Engineer-in charge. The work will be carried out with in distance 1KM from road.
3All as per item No.2 above but pit of internal size is 610x610x690mm complete all as specified and directed.
4Taking down 80 mm bore diaCI/DI pipe including connected items and connections complete all as specified and directed by Engr-in-Charge
5All as per item No.4 above but 100mm bore complete all as specified and directed.
6All as per item No.4 above but 150mm bore complete all as specified and directed.
7Refixing CI/DI PipeI tubing of 80mm bore size with and including all fitting and fixtures laid in trenches complete all as specified and directed by Engr-in-Charge.
8All as per item No.7 above but 100mm bore complete all as specified and directed.
9All as per item No.7 above but 150mm bore complete all as specified and directed.
10Supply and laying pipe ductile Iron ,Class “K-7” ,150 mm (6”) dia including jointing material, fittings etc all as required at site complete all as specified and directed by Engr-In-Charge
11Supply and laying pipe ductile Iron ,Class “K-7” ,100 mm (4”) dia including jointing material, fittings etc all as required at site complete all as specified and directed by Engr-In-Charge
12Material & Labour for cleaning of RCC over head water tank using alum water, height up to 15 mtr including pumping out balance water, taking out dirty water stone pieces and sludge etc by usnig buckets, cleaning and removing all dirt and plankton completely from wall and flour of the tank and from mouths of inlet and outlet pipes etc and by rubbing with wire brushes and removing all waste to distance not exc 50 mtr and depositing where directed cleaning the tank with fresh water and removing dirty water out of the tank writing on tank date of cleaning on external surface with synthetic enamel paint after removing old date complete all as specified and directed by Engr-in-Charge for the following capacity (Note - The cleaning of Over head tank will be planning such as time that there should no hindrence occure of water distribution system) (a) 50000 gallons capacity
13All as per item No.12 above but 25000 gallons capacity complete all as specified and directed.
14Supply & Fixing FASD starter panel suitable for three phase 40 HP submersible pump with over load relay having range of 36 to 60 Amps, coil voltage 380 to 415 volts, including contactors, timers, single phase preventer, voltmeter/ammeter of suitable capacity prewired incl taking down the existing unserviceable starter complete all as specified and directed by Engr-in-charge.
15Supply & Fixing FASD starter panel suitable for three phase 30 HP submersible pump with over load relay having range of 30 to 50 Amps, coil voltage 380 to 415 volts, including contactors, timers, single phase preventer, voltmeter/ammeter of suitable capacity prewired incl taking down the existing unserviceable starter complete all as specified and directed by Engr-in-charge.
16Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for foundation etc or for laying of pipes etcand getting out in soft/loose soil, complete all as specified and directed by Engr-in-charge.
17Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil, complete all as specified and directed by Engr-in-charge.
18Removing excavated soil to a distance exc 50m and not exc 250 m and depositing where directed at a level not exceeding 1.5 m above the starting point , complete all as specified and directed by Engr-in-charge.
19Taking up or downsteel tubingof size 15mm bore pipe including connected items and connections complete all as specified and directed by Engr-in-Charge.
20All as per item No.19 above but 20mm bore complete all as specified and directed.
21All as per item No.19 above but 25mm bore complete all as specified and directed.
22All as per item No.19 above but 40/50mm bore complete all as specified and directed.
23All as per item No.19 above but 80mm bore complete all as specified and directed.
24All as per item No 19 above but 100mm bore complete all as specified and directed.
25Relaying GI tubing 15 mm bore size with and including all fitting and fixtures laid in trenches complete all as specified and directed by Engr-in-Charge.
26All as per item No.25 above but 20mm bore complete all as specified and directed.
27All as per item No.25 above but 25mm bore complete all as specified and directed.
28All as per item No.25 above but 40/50mm bore complete all as specified and directed.
29All as per item No.25 above but 80mm bore complete all as specified and directed.
30All as per item No.25 above but 100mm bore complete all as specified and directed.
31Supply & Fixing 15mm bore GI tubing, medium grade with and including all fitting and fixtures laid in trenches complete all as specified and directed by Engr-in-Charge.
32All as per item No.31 above but 20mm bore complete all as specified and directed.
33All as per item No.31 above but 25mm bore complete all as specified and directed.
34All as per item No.31 above but 40mm bore complete all as specified and directed.
35All as per item No.31 above but 50mm bore complete all as specified and directed.
36All as per item No.31 above but 80mm bore complete all as specified and directed.
37All as per item No.31 above but 100mm bore complete all as specified and directed.
38Supply and lower submersible copper cable 16 Sqmm, 3 Core, 1100 voltscomplete all as specified and directed by Engineer-in-Charge
39Supply and lower submersible copper cable 25 Sqmm, 3 Core, 1100 volts complete all as specified and directed by Engineer-in-Charge
40Cleaning of pit chamber of Domestic area including painting MS Pit cover complete all as directed by Engr In Charge. (Note : Location of water chambe will be decided by Engr In Charge.)
41M& Lcutting of bushesgrassand cleaning area with help of cutting tools and dumping all waste materialto suitable placecomplete all as specified and directed by Engineer-in-Charge
42Taking down old unserviceable water level indicator assembly, consisting of mild steel level indicator with superior quality steel wire of suitable length, balancing weight, a set of pulley duly grouted in wall of RCC over headtank with MS support, Brass/copper float valve, including painting of MS scale with synthetic enamel paint and marking the required numbers/scale in red/black colour complete all as specified and directed by the Engineer in Charge
43Painting of MS Ladder fixed on water tank with recommendedcolour with paints two coat over a coat of red oxide complete all as specified and directed
44Supply and filling calcium hypochlorites dry free flowing and free from lumps should not induce substance beyond acceptable limit as given in IS 10500(2012) in treated and disinfected water available chlorine content 65% minimum by mass, Stability 1/15 maximum loss of chloride on basis of available chloride, particle size 99.5 % wise, water insoluble matter 6% max, Calcium hydroxide 4% max, Sodium Chloride 15% max as approved by E-in-C Branch.
45Supply and replacement of union nut PVC for chlorine dosing system matching with existing sample complete all as specified and directed by Engineer in Charge complete
46Supply and replacement ofreducer for dosing pump all asper existing sample complete all as specified and directed by Engineer –in-Charge.
47S&F in replacement of PumpTube of Dosing Pump matching with existing sample complete all as directed and specified by Engr-in- Charge .
48Supply and replacement of Motor Agitator including shaft blades etc for chlorine dosing system matching with existing sample complete all as directed and specified by Engineer-in-Charge
49S & F in replacement high density polyethylene pipe (HDPE) having pressure rating 6kgf/cm2 fixed complete to walls, ceilings or in floors from dosing pump to chlorine feeding point matching with existing sample complete all as specified and directed by Engineer-in-Charge
50S&F in replacement non return valve suitable for dosing system matching with existing sample complete all as specified and directed by Engr-In-Charge.
51Material & Labour for Cement concrete for repair of broken valve pits type C-2 using 40mm graded aggregate ratio 1:3:6 complete all as specified and directed by Engr-in-Charge.
52Replacement of spindle brass/stainless steel with wheel of sluice valve of 80mm dia complete all as specified and directed by Engr-in-Charge.
53All as per item No. 52 above but 100mm dia complete all as specified and directed by Engr-in-Charge.
54All as per item No. 52 above but 150mm dia complete all as specified and directed by Engr-in-Charge.
55Material & Labour for 150 mm bore sluice valve type PN-1 double Flanged cost iron type with brass spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete all as specified and directed by Engr-in-Charge.
56Material & Labour for 100 mm bore sluice valve type PN-1 double Flanged cast iron type with brass spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete all as specified and directed by Engr-in-Charge.
57Material & Labour for 80 mm bore sluice valve type PN-1 double Flanged cast iron type with brass spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete all as specified and directed by Engr-in-Charge.
58Material & Labour for 150 mm bore non return valve type PN-1 double Flanged cast iron type with brass spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete all as specified and directed by Engr-in-Charge.
59Material & Labour for Run lead joint to 150 mm bore complete and complete all as specified and directed by Engr-in-Charge.
60Material & Labour for Run lead joint to 100 mm bore complete and complete all as specified and directed by Engr-in-Charge.
61Material & Labour for Run lead joint to 80 mm bore complete and complete all as specified and directed by Engr-in-Charge.
62Material & Labour for Cutting of cast iron pipe 80 mm dia to required length before laying pipe complete all as specified and directed by Engr-in-Charge.
63Material & Labour for Cutting of cast iron pipe 100 mm dia to required length before laying pipe complete all as specified and directed by Engr-in-Charge.
64Material & Labour for Cutting of cast iron pipe 150 mm dia to required length before laying pipe complete all as specified and directed by Engr-in-Charge.
65Supply and fixing of 15mm GI fittings i.e elbow complete all as specified and directed by Engr-in-Charge.
66All as per item No. 65 above but 20mm elbow complete all as specified and directed by Engr-in-Charge.
67All as per item No. 65 above but 25mm elbow complete all as specified and directed by Engr-in-Charge.
68All as per item No. 65 above but 40mm elbow complete all as specified and directed by Engr-in-Charge.
69All as per item No. 65 above but 50mm elbow complete all as specified and directed by Engr-in-Charge.
70Supply and fixing for 15mm dia GI fittings i.e socketcomplete all as specified and directed by Engr-in-Charge.
71All as per item No. 70 above but 20mm socket complete all as specified and directed by Engr-in-Charge.
72All as per item No. 70 above but 25mm socket complete all as specified and directed by Engr-in-Charge.
73All as per item No. 70 above but 40mm socket complete all as specified and directed by Engr-in-Charge.
74All as per item No. 70 above but 50mm socket complete all as specified and directed by Engr-in-Charge.
75Supply and fixing of 15mm dia GI fittings i.e union complete all as specified and directed by Engr-in-Charge.
76All as per item No. 75 above but 20mm union complete all as specified and directed by Engr-in-Charge.
77All as per item No. 75 above but 25mm union complete all as specified and directed by Engr-in-Charge.
78All as per item No. 75 above but 40mm union complete all as specified and directed by Engr-in-Charge.
79All as per item No. 75 above but 50mm union complete all as specified and directed by Engr-in-Charge.
80Supply and fixing of 15mm dia GI fittings i.e nipplecomplete all as specified and directed by Engr-in-Charge.
81All as per item No. 80 above but 20mm nipple complete all as specified and directed by Engr-in-Charge.
82All as per item No. 80 above but 25mm nipple complete all as specified and directed by Engr-in-Charge.
83All as per item No. 80 above but 40mm nipple complete all as specified and directed by Engr-in-Charge.
84Material & Labour for Brick work with subclass old sized ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar of ratio 1:6 for repair of broken valve pits complete all as specified and directed by Engr-in-Charge.
85Material & Labourfor cement plastering in CM 1:4, 10 mm thick on Brickmasonery surfaces incl finishing the surfaces even and smooth w/out using extra cement complete all as specified and directed by Engr-In-Charge.
86Material & Labour for cross arms bracing support clamps and back plates fabricated iron structural steel section incl nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat and one under coat and one finishing coat of alluminium paint complete all as specified and directed by Engr-In-Charge.
87Material & Labour for Cast iron bends (any type radius and angle) taper any type (Straight) bend increasing Per decreasing or double socket etc Tee peces, single branch "Y" junction double branch, coller, Kg capacity and plugs for 80 mm bore to 150 mm bore CI pipe conforming to IS-1538-1976 complete all as specified and directed by Engr-In-Charge.
88Material & Labour for Breaking road, pavement, hard standing, tiles of any type, including excavation of subbase, soil upto the depth of 0.60 mtr and width 0.45 mtr by mechanical means for fault finding in water pipe lines and including making good to the disturbed surfaces matching with existing after rectification of fault including removal of surplus material to nearby dumping point complete all as specified and directed by Engr-In-Charge.
89Supply and fixing in replacement thermal over load relay suitable for oil immersed star delta starter for submersible pumps of rating 15 to 25 HP matching with existing sample including connections with existing star delta starters complete all as specified and directed by Engr-In-Charge.
90Supply and fixing in replacement thermal over load relay suitable for oil immersed star delta starter for submersible pumps of rating 30 to 40 HP matching with existing sample including connection with existing star delta starter complete all as specified and directed by Engr-In-Charge.
91Supply and fixing in replacement single phase prevention relay suitable for star delta starters, of capacity upto 40 HP, with auto, mannual and bypass operation, with time delay setting including wiring and connection with existing star delta starter complete all as specified and directed by Engr-In-Charge.
92Supply and fixing in replacement electronic timer suitable for star delta starters, having coil voltage 380 to 415 volts, with time delay 3 to 30 seconds, complete including wiring and connections with existing star delta starter complete all as specified and directed by Engr-In-Charge.
93Material & Labour for Strip opening of pump of any type of submersible/centrifugal motor 15 HP to 40 HP of any stage/ size/ make and re assembling including replacement of defective items and reassembling complete after repair including testing at workshop complete all as specified and directed by Engr-In-Charge. (Note major defective items replaced will be measured and paid seperately under respective item of schedule, cost of items not mentioned in schedule and to be replaced is deemed to be included in quoted rates.)
94Supply only following items to be fixed under items above:- (a) Pump shaft stainless steel for 20to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
95All as per item No. 94 above butImpeller bronze/ Gun metal for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
96All as per item No. 94 above butCI neck ring for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
97All as per item No. 94 above butGun metal intermediate bush for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
98All as per item No. 94 above butSuction/Discharge Bush for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
99All as per item No. 94 above butCI bowl for pump for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
100All as per item No. 94 above but Middle distance bush of stain less steel for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
101All as per item No. 94 above butShaft coupling stain less steel for 20 to 40 HP pump matching with existing size complete all as specified and directed by Engr-In-Charge.
102Taking out submersible pump set 20 HP to 40 HP from the bore well in any depth complete with column pipe and other connected part and lowering the same after repair of the pump set including checking of pump set for faults before shifting to workshop complete all as specified and directed by Engr-In-Charge. (Note: Required T&P for above work and transportation to workshop and taking back is deemed to be included in quoted rates)
103Material & Labour for Strip opening 3 phase 20 to 40 HP capacity AC submersible motor taking out burnt winding coils complete and rewinding with insulated water proof winding wire matching with existing size including seal PVC (water proof compound) reassembling the motor and testing at workshop complete all as specified and directed by Engr-In-Charge. (Note: Insulation to wires, windings, varnishing,and other items required for rewinding and making motor water proof not mentioned in description and T&P required for this job is deemed to be included in quoted rates.)
104Supply and replacement thrust plate matching with existing size suitable for 20 to 40 HP electric Motor complete all as specified and directed by Engineer-in-Charge.
105Supply & Fixing in replacement Stud with nuts including spring washer matching with existing complete all as specified and directed by Engr-In-Charge.
106Supply & Fixing in replacement Water seal suitable for submersible motor matching with existing complete all as specified and directed by Engr-In-Charge.
107Supply & Fixing of 50mm bore sizes ofgate valve Gun metal screwed down high pressure with crutch with or butter fly handle screwed booth ends for pip complete all as specified and directed by Engr-In-Charge.
108All as per item No. 107 above but40mm bore complete all as specified and directed by Engr-In-Charge.
109All as per item No. 107 above but25mm bore complete all as specified and directed by Engr-In-Charge.
110All as per item No. 107 above but20mm bore complete all as specified and directed by Engr-In-Charge.
111All as per item No. 107 above but15mm bore complete all as specified and directed by Engr-In-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail