Tender Details

Tender For Construction And Development Of Herbal Garden At Aiims Nagpur; 1 Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees, Garbage, Soil And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 100 M Outside The Periphery Of The Area Cleared. ( By Means Of Mechanical Such As Surface Dresser / Jcb Etc ) ( Inlcuding Levelling Of Area Wherever Requried For Complete Area ) 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge All Kinds Of Soil 3 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 4 Soling ( Or Sub Base ) With Broken Boulders Or Quarried Stone, Inter Stices Filled, Surface Formed And Rolled And Consolidated To Required Gradient And Camber ( 150 Mm Thickness ) ( Or Using Gsb Material .075 Mm To 75 Mm Mix Material Used For Wmm / Wbm Road Purpose ) 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 8 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) ( Use Of Rmc Plant Mix Is To Be Done As Per Direction Of E-I-C ) 6 Providing And Laying Up To Floor Five Level Reinforced Cement Concrete In Kerbs, Steps And The Like Including The Cost Of Centering, Shuttering, Finishing With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . 7 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing ( All Work Up To Plinth Level ) 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources ) 8 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 9 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 10 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes 11 12 Mm Cement Plaster Of Mix 1:6 ( 1 Cement: 6 Fine Sand ) 12 Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete 13 Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slabover 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Colour Of Black, Cherry / Ruby Red Or Equivalent 14 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 15 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 16 Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete. Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1.4 Mm Aperture On Both Sides 17 Providing And Applying White Cement Based Putty Of Average Thickness1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 18 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 19 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work 20 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) . Dark Shade Pigment Using Ordinary Cement 21 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Including Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm ) , Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge ( Length Of Finished Kerb Edging Shall Be Measured For Payment ) . ( Precast C.C. Kerb Stone Shall Be Approved By Engineer-In-Charge ) . 22 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size / Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding / Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge. 60Mm Thick Cement Concrete Paver Block Of M-35 Gradewith Approved Colour, Design & Pattern. ( Please See Sample Picture For Paver Block Designs ) 23 Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-In-Charge. Made Of G.I. Wire Of Dia 4 Mm 24 Supply And Installation Of Translucent Roof With Dpi Flux Standing Seam Multicell Polycarbonate Panel System. The System With Complete Assembly Of Co Extruded Uv Protected Multicell Panels Incorporated Into A Complete System. Co-Extruded Uv Protected Polycarbonate Panel System Of Min 12 Mm Thick Of 900 Mm ( Min. ) Width With Angular Daylighting Concept. Panels Shall Have Minimum Six Layers With Truss Bridge Design For Higher Flexibility & Strength. Panels With All Fixing Accessories To Ensure Best Performance For Wind Uplift, Vibration, Oil Canning And Visual Appearance. Panels Shall Be Manufactured With Vertical Standing Seam At Both Sides Of The Panel. Panels Shall Be Fixed On Purlin With Snap On Connectors With Double Tooth Grip Lock Locking Mechanism And Will Be Secured On Ms Structure ( Will Be Paid Separately ) With 3 One Numbers Self-Drilling Screws & Trapezoid Ss Fasteners Holding The Base Of The Standing Seam Offering Best Stability Having A Pull-Out Load Of Min. 7000N ( 7Kn ) Tested As Per Iso 6892:1998 And Is 1608: 2005, As Per Design Requirement. Panels Must Satisfy Dart Drop Impact Test As Per Is 14443-97 Shall Show No Sign Of Breakage On Polycarbonate Sheets Which Have Been Exposed To Uv For A Min. Of 500 Hours As Per Astm G 155. Panels Shall Not Have Yellowness Index As Per Astm D 1925 Of 15 Units When Tested On A Sample Exposed To Uv For 500 Hours As Per Astm G 155. U Value Shall Not Be More Than 1.6 W / M2k As Per En Iso 10077-2:2018. Panel Shall Be With Additional End Cap / Aluminium U / F Profile / Glazing Bar For Ends As Required. Panel Shall Be Fixed Over Ms Structural Steel / Ms Purlin ( Paid Separately ) Conforming To The Detail Technical Specifications As Per Approved Architectural Drawings. Trained And Factory Authorized Labour With Supervision To Complete The Entire Panel Installation As Per Drawing & Direction Of The Engineering In Charge. Colour: As Per Approval. Approved Make: Flux By Dpi Daylighting Or Approved Equivalent The 12Mm Thick Panels Shall Be Used For A Roofing Height Of Upto 15 Mtrs. 25 Supplying, Stacking And Spreading Of Vermicompost ( Material To Be Supplied In Bags, Weighing Shall Be Done In Presence Of Aiims Nagpur Representative And Shall Be Supplied In Bag Of 30 / 40 Kg Only. ) 26 Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage ( Earth Measured In Stacks Will Be Reduced By 20% For Payment, Supply Of Good Earthe Shall Be Fine, It Should Not Be In Lumps, Fine Dressing To Be Included In The Same Measurement ( Good Earth Should Be Free Of Lumps / Rocks / Impurities ) ( Sample To Be Produced Of 50-100 Kg Before Bulk Supply ) 27 Supplying & Laying Of Korean Grass At Site Fresh & Free From Weeds Having Proper Roots In Green Including Loading, Unloading, Carriage And All Taxes Paid Etc. And As Per Direction Of Officer In Charge. ( Complete Roll Of Embedded Grass Shall Be Provided On Site And No Dubbing Shall Be Allowed Whereas Cutting Measurement Of Grass Roll Shall Be Taken On Site ) 28 Preparation Of Mounds Of Various Size And Shape By Available Excavated / Supplied Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering Of Each Layer, Dressing Etc., Lead Upto 50 Meter And Lift Complete As Per Direction Of Officer-In-Charge. 29 Anti Termite Treatment Of Lawn Area Through Premise 30.50% I P. One Liter Premise Diluted In 499 Liters Water And Applying Solution @ 1.00 Litre Solution Per Sqm Lawn Or Bed Area. ( Two Application ) I / C Cost Of Chemical ) And As Per Direction Of Officer-In-Charge.And As Per Direction Of Officer-In-Charge. 30 Providing & Fixing Of White River ( Stone ) Pebbles Size Of 2 To 2.50 Dia In Natural Colour At Site Of Work Including Loading, Unloading, Carriage And All Taxes Paid Etc.And As Per Direction Of Officer In Charge 31 Supplying And Spreading Of Sand In Lawn Area, Includingwatering, And Dressing Complete. 32 Providing And Stacking Of & Plantation Of Well-Developed And Multi Branches / Leafsphyllanthus Emblica ( Amla ) & Long Folia ( Ashok ) Of Height 150-165 Cm. In Big Poly Bags Of Size 30 Cm As Per Direction Of The Officer-In-Charge. 33 Providing , Stacking & Plantation ( Herbalof Well-Developed And Multi Branches / Leafs With Height Of 30-90 Cm In Poly Bags Of 25-30 Cm As Per Approval & Directionofthe Officer-In-Charge Of Aiims Nagpur Following Plants With Numbers:- ( Ashwagandha-30 ) , ( Satavari-30 ) , ( Tulsi-30 ) , ( Alovera-30 ) , ( Lemon Grass-30 ) , ( Giloy-30 ) , ( Sarpgandha-30 ) , ( Mandukparni-30 ) , ( Steviea-30 ) , ( Aprajita-30 ) , ( Peepli-30 ) , ( Chitrak-30 ) , ( Dambel-30 ) , ( Hadjod-30 ) , ( Lajvanti-30 ) , ( Bajradanti-30 ) , ( Neer Bramhi-30 ) , ( Shankhpushpi-30 ) , ( Nirgundi-30 ) , ( Marwa Dona-30 ) , ( Tagar-30 ) , ( Bay Leaf Plant-30 ) , ( Kalihari-30 ) , ( Sea Buckthorn-30 ) , ( Arjuna-30 ) , ( Kokam-30 ) , ( Kuth-30 ) , ( Kutki-30 ) , ( Atees-30 ) , ( Makoy-30 ) , ( Bach-30 ) , ( Bael-30 ) , ( Mulethi-30 ) , ( Gudmar-30 ) , ( Bahera-30 ) , ( Giloy-30 ) , ( Punarnava-30 ) , ( Ratalu-30 ) , ( Safed Musali-30 ) , ( Sadabahar-30 ) , ( Fannel-30 ) , ( Dalchini-30 ) , ( Indian Carom Ajwain-30 ) , ( Daruhaldi-30 ) , ( Kasturi Methi-30 ) , ( Peeparmint-30 ) , ( Rosemary-30 ) , ( Turmeric-30 ) ( Guggal-30 ) 34 Providing And Fixing Fiber Glass Reinforced Plastic ( Frp ) Door Frames Of Cross-Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminate Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steadythe Frame. 35 Providing And Fixing To Existing Door Frames.30 Mm Thick Glass Fibre Reinforced Plastic ( Frp ) Panelled Door Shutter Of Required Colour And Approved Brand And Manufacture, Made With Fire - Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate For Forming Hollow Rails And Styles, With Wooden Frame And Suitable Blocks Of Seasoned Wood Inside At Required Places For Fixing Of Fittings, Cast Monolithically With 5 Mm Thick Frp Laminate For Panels Conforming To Is: 14856, Including Fixing To Frames. 36 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding. 37 Providing Gola 75X75 Mm In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10 Mm And Down Gauge ) , Including Finishing With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) As Per Standard Design :1 In 75X75 Mm Deep Chase 38 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 39 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water / Drain Waterpipes Conforming To Is : 13592 Type A / B, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 110 Mm Diameter With All Fittings ( Traps, Bend, T , Socket & Cuplers Etc. ) Required As Per Site 40 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. Each 41 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm Ptmt Pillar Cock, 32 Mm Ptmt Waste Coupling Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required. White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm Ptmt Pillar Cock. 42 17.28 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete.17.28.2 Flexible Pipe 32 Mm Dia 43 Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. 44 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete 45 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall Of ( 15Mm = 40 Mtr, 20Mm =20 Mtr , 25Mm=40 Mtrnominal Dia Pipes ) 46 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. External Work Of ( 25Mm = 50 Mtr, 32Mm =30 Mtr , 50Mm=70 Mtrnominal Dia Pipes ) 47 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 18.21.2 45 Cm Length 15 Mm Nominal Bore 48 Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design :With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 49 Constructing Masonry Chamber 60X45x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Water Meter Complete With C.I. Double Flap Surface Box 400X200x200 Mm ( Inside ) With Locking Arrangement And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete Asper Standard Design : 18.37.1 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 50 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 51 Providing And Fixing Ptmt Fittings Of Approved Quality And Colour By Engineering Incharge Of Aiims Nagpur Of ( 15 Mm Nominal Bore ) Following Fittings ( Bib Cock-05, Conclead Stop Cock -05, Pillar Cock-05, Push Cock-05, Angle Stop Cock-05 ) 52 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70Kg As Per Standard Design: 100X100 Mm Size P Typewith Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 53 Providing, Laying And Jointing Glazed Stoneware Pipes Class Sp-1 With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 ( 1 Cement : 1 Fine Sand ) Including Testing Of Joints Etc. Complete : 100 Mm Diameter 54 Providing And Laying Cement Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design :100 Mm Diameter S.W. Pipe 55 Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Rcc Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 ( 5 Parts Integral Crystalline Slurry : 2 Parts Water ) For Vertical Surfaces And 3 : 1 ( 3 Parts Integral Crystalline Slurry : 1 Part Water ) For Horizontal Surfaces And Applying The Same From Negative ( Internal ) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci- 212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineer-In-Charge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakagefor Vertical Surface Two Coats @ 0.70 Kg Per Sqm, For Horizontal Surface One Coat @1.10 Kg Per Sqm. 56 Providing And Fixing Glass Mossaic Tiles On Finished Plain Wall Surface Of Size 20 Mm X 20 Mm X 4 Mm In All Colour, Design , Fixing In Customize Design As Per Direction Of Engineer-In- Charge. The Glass Mosaic Tiles To Be Fixed On The Wall Surface With The Help Of Approved Adhesive Applied At The Rate Of 2.5 Kg Per Sqm And Grouting Of The Same. The Rate Is Inclusive Of All Operation, Material And Required Pattern Approved By Engineer-In-Charge: 57 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 58 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 100 A, 4 Pole Isolator 59 Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A, 4 Pole Rccb 60 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. ( 3 1 / 2X 35 Sq.Mm Armoled Aluminium Cable ) 61 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. ( 4 X 10 Sq.Mm Armoled Aluminium Cable ) 62 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. ( 4 X 6 Sq.Mm Flexibal Copper Cable ) Forfountein 63 Supplying And Making Termination With Brass Comperation With Gland And Aluminium Lugs For Following Size Pvc Insulated And Pvc Sheathed / Xpel Aluminium Conductor Cable Of 1.1Kv Gread 31 / 2 X 35 Sq. Mm. 64 Supplying And Making Termination With Brass Comperation With Gland And Aluminium Lugs For Following Size Pvc Insulated And Pvc Sheathed / Xpel Aluminium Conductor Cable Of 1.1Kv Gread 4 X 10 Sq. Mm. 65 Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Acessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arregment And Watering Pipe Etc. ( But Without Charcoal / Coke And Salt ) As Required 66 Supplying And Laying 6 Swg G.I. Wire At 0.50 Metre Below Ground Level For Conductor Earth Electrode, Including Connection / Termination With Gi Thimble Etc. As Required. 67 Supplying And Fixing Horizontal Type Feeder Panel Single Door Three Pole And Neutral, Sheet Steel, Mcb Distribution Board 415Volts, On Surface / Mounted, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Eart Bar, Din Bar , Interconnections, Powder Painted Including Earthing Etc As Required. ( With Including On / Off Switch & Indication , 6Nos. Timer, Contactor, Connections, Etc ) 68 Supplying And Fixing Horizontal Type Controling Panelsingle Door Three Pole And Neutral, Sheet Steel, Mcb Distribution Board 415Volts, On Surface / Mounted, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Eart Bar, Din Bar , Interconnections, Powder Painted Including Earthing Etc As Required. ( With Including Timer, Contactor Connections, Etc ) 69 Supplying & Fixing Following Rating 3 Meter Ring Type Bollard 30-40W Ledlights With 10 Amp Two Pole Mcb In Each Pole ( Including Excavation, Pcc, Grouting, Anchor Bolting All Civil Works Required For Fixing Of Bollard Light Shall Be Included ) 70 Supplying & Fixing Following Rating 1 Meter Bollard Light With 12 Ledlights ( Including Excavation, Pcc, Grouting, Anchor Bolting All Civil Works Required For Fixing Of Bollard Light Shall Be Included ) ( As Per Sample Picture Attached ) 71 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 72 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 73 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 74 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 75 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 76 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Sq.Mm. 77 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earthbar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 8 Way , Single Door 78 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required Single Pole ( 20Amps ) 79 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A 80 Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required. 8 Way , Single Door 81 Supply, Installation, Storing, Testing And Commissioning Of Recess Mounting Led Luminarie Philips Make Full Glow Light 18 W Led Tube 82 Supply, Installation, Storing, Testing And Commissioning Of Wall Mountingfan Philips / Bajaj / Crompton Make 400 Mm Dia Wall Mount Fan 83 Supply Installation Testing Commissioning Of Aluminum / Stainless Steel Dandelion ( Spherical ) Outdoor Fountain With Sizes Of Brass Ball Of 8- 12 With Aluminum / Stainless Steel Spokes Of 18-24 ( Length / Size As Per Requirement Of Spherical Pattern ) With 72 -102 Spokes Per Fountain Fitted With Brass Nozzles By Many Branches Of The Small Nozzle, Connected In The Center Of The Sphere, And The Formation Of A Large Radial Sphere Of ( 1.5-2M Dia, With Vertical Fall / Pipe Height Of 1500 Mm Above Top / Overflowing Water Level Of Inner Tank ) . Provision Of 10 Hp ( Or Higher ) Pump / Pump According To The Requirements Of The Fountain, Led Coloured Lights With 4 Core 4 Sq Mm Flexible Copper Cable For 12 Rbg Lights 18 W-24 W With Bubbler / Foam Nozzle ( 12 Nos In Quantity ) Waterproof Grade Ip68, Which Can Be Soaked In Water For A Long Time 24V Safe Voltage Without Electric Shock Hazard, Stainless Steel Toughened Glass Mask Used, Which Has Strong Shockproof And Fall-Resistant Ability Lamp Body Is Made Of 304 Stainless Steel With All G.I Plumbing Fittings, Accessories And Support Made Of Gi Pile With Base Plate, Chemical Fasteners And Clamps With Nut Bolts For Gi Pipe Line Inclusive Of Painting The Gi Pipe With Two Coats Of Primer And Two Coats Of Anti-Corrosive Paint Complete As Required And As Per The Directions Of Engineer In Charge. The Fountain To Be Designed To Throw The Water Splash Radius Of 2.0 Meter The Water Body From All The Nozzles ( The Payment For Civil Works Shall Be Made Under Respective Items. ) ( Note:- Sample Design Is To Be Similar Like Picture Or Drawing Attached For Reference Purpose ) ( Summary -01 Dandelion Fountain With Spokes And Brass Nozzles, 12 Foam / Column Jet Nozzle, 12 Rbg Led Lights Of Applicable Wattage, 10 Hp Or More Pump, Gi Pipe Fittings, Ss Pipe Fittings Including Electrical Fitting And Electrical Panel Or Fountain Etc. ) 84 Supply Installation Testing Commissioning All Arrangements For Bird Bath Including Minimum 1.5 Meter Height And 1.2-1.5 Meter Diametal / Stone Sculpture With 1.8-2 Meter Dia Circular Shape Inner Tank / Platform, Outer Tank Of Dia 3.5- 4 Metrehaving Water Flow Systemincluding08 Nos Of Foam Jet Nozzle Of Brass With Stainless Steel Finish, 2” ( 50Mm ) Intel Size, Spray Dia : 25 Mm Dia. With G.Iheader Line Of 2 ( 50 Mm ) With All G.I Plumbing Fittings, Accessories And Support Made Of Gi Pile With Base Plate, Chemical Fasteners And Clamps With Nut Bolts For Gi Pipe Line Inclusive Of Painting The Gi Pipe With Two Coats Of Primer And Two Coats Of Anti-Corrosive Paint, 8 Rbg Underwater 12W - 18 W, Ip68 Rated Different Colour Led Lights With 4 Core 4 Sq Mm Flexible Copper Cable For Rbg Lights And Pump, And 3.5 Hp ( Or Higher As Per Requirement ) Pump For Water Circulation Complete As Required And As Per The Directions Of Engineer In Charge. The Bird Bath Is To Be Designed To Throw The Water Foam Jet To Uniform Shape And Flow 1-1.5 Meter High Surround The Bird Bath From All The Nozzles ( The Payment For Civil Works Shall Be Made Under Respective Items. ) ( Note:- Sample Design Is To Be Similar Like Picture Or Drawing Attached For Reference Purpose )

Key Value

Document Fees
Refer document
EMD
INR 327000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Development and Construction of Herbal Garden at AIIMS Nagpur
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees,garbage,soil and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 100 m outside the periphery of the area cleared. (by means of mechanical such as surface dresser/ JCB etc) (inlcuding levelling of area wherever requried for complete area)
2Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge All kinds of soil
3Filling available excavated earth in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber (150 mm thickness) (or using GSB material .075 mm to 75 mm mix material used for WMM/WBM road purpose)
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources) (Use of RMC plant mix is to be done as per direction of E-i-C)
6Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like including the cost of centering, shuttering, finishing with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
7Providing and laying in position specified grade of reinforced cement concrete, Including the cost of centering, shuttering, finishing (All work up to plinth level) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
8Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
9Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
10Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
1112 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
12Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
13Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
14Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
15Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
16Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
17Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
18Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
19Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work
20Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement
21Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
22Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (please see sample picture for paver block designs)
23Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
24Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.
25Supplying, stacking and spreading of vermicompost (material to be supplied in bags, weighing shall be done in presence of AIIMS Nagpur representative and shall be supplied in bag of 30/ 40 kg only.)
26Supplying and stacking of good earth at site including royalty and carriage (earth measured in stacks will be reduced by 20% for payment, supply of good earthe shall be fine, it should not be in lumps, fine dressing to be included in the same measurement (good earth should be free of lumps / rocks / impurities)(sample to be produced of 50-100 kg before bulk supply)
27Supplying & laying of Korean grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc. and as per direction of officer in charge.(Complete roll of embedded grass shall be provided on site and no dubbing shall be allowed whereas cutting measurement of grass roll shall be taken on site)
28Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift complete as per direction of Officer-in-charge.
29Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
30Providing & fixing of White River (Stone) Pebbles size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge
31Supplying and spreading of sand in lawn area, including watering, and dressing complete.
32Providing and stacking of & Plantation of well-developed and multi branches/leafsPhyllanthus emblica (Amla) & long folia (Ashok) of height 150-165 cm. in big poly bags of size 30 cm as per direction of the officer-in-charge.
33Providing , Stacking & Plantation (Herbalof well-developed and multi branches/leafs with height of 30-90 cm in poly bags of 25-30 cm as per approval & directionofthe officer-in-charge of AIIMS NAGPUR Following Plants with Numbers:- (Ashwagandha-30),(Satavari-30),(Tulsi-30),(Alovera-30),(Lemon grass-30),(Giloy-30),(Sarpgandha-30) ,(Mandukparni-30) ,(Steviea-30) ,(Aprajita-30) ,(Peepli-30) ,(Chitrak-30) ,(Dambel-30) ,(Hadjod-30) ,(Lajvanti-30),(Bajradanti-30),(Neer Bramhi-30) ,(Shankhpushpi-30) ,(Nirgundi-30) ,(Marwa Dona-30),(Tagar-30),(Bay Leaf Plant-30) ,(Kalihari-30),(Sea Buckthorn-30) ,(Arjuna-30),(Kokam-30),(Kuth-30) ,(Kutki-30) ,(Atees-30) ,(Makoy-30) ,(Bach-30),(Bael-30) ,(Mulethi-30) ,(Gudmar-30) ,(Bahera-30),(Giloy-30),(Punarnava-30),(Ratalu-30) ,(Safed Musali-30) ,(Sadabahar-30) ,(Fannel-30),(Dalchini-30) ,(Indian Carom Ajwain-30) ,(Daruhaldi-30),(Kasturi Methi-30),(Peeparmint-30),(Rosemary-30),(Turmeric-30) (Guggal-30)
34Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
35Providing and fixing to existing door frames.30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
36Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding.
37Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :1 In 75x75 mm deep chase
38Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
39Providing and fixing on wall face unplasticised Rigid PVC rain water/Drain waterpipes conforming to IS : 13592 Type A/B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter With All Fittings (Traps, bend, T ,socket & Cuplers etc.)required as per site
40Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. each
41Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
4217.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.2 Flexible pipe 32 mm dia
43Providing and fixing 100 mm sand cast Iron grating for gully trap.
44Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall of ( 15mm = 40 mtr, 20mm =20 mtr , 25mm=40 mtrnominal dia Pipes)
46Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work of ( 25mm = 50 mtr, 32mm =30 mtr , 50mm=70 mtrnominal dia Pipes)
47Providing and fixing uplasticised PVC connection pipe with brass unions : 18.21.2 45 cm length 15 mm nominal bore
48Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
49Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.37.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
50Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
51Providing and fixing PTMT Fittings of approved quality and colour by Engineering Incharge Of AIIMS NAGPUR of (15 mm nominal bore)Following Fittings ( bib cock-05, Conclead Stop Cock -05,Pillar Cock-05, Push Cock-05,Angle Stop Cock-05)
52Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 100x100 mm size P typeWith common burnt clay F.P.S. (non modular)bricks of class designation 7.5
53Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter
54Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe
55Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage For vertical surface two coats @ 0.70 kg per sqm, For horizontal surface one coat @1.10 kg per sqm.
56Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:
57Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
58Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A, 4 pole isolator
59Supplying and fixing following rating, Four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A, 4 pole RCCB
60Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (3 1/2x 35 Sq.mm Armoled Aluminium Cable)
61Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (4 x 10 Sq.mm Armoled Aluminium Cable)
62Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (4 x 6 Sq.mm flexibal Copper Cable) forfountein
63Supplying and making Termination with brass comperation with gland and aluminium lugs for following size PVC insulated and PVC sheathed/ XPEL aluminium conductor cable of 1.1kv gread 31/2 x 35 Sq. mm.
64Supplying and making Termination with brass comperation with gland and aluminium lugs for following size PVC insulated and PVC sheathed/ XPEL aluminium conductor cable of 1.1kv gread 4 x 10 Sq. mm.
65Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including acessories, and providing masonry enclosure with cover plate having locking arregment and watering pipe etc. (But without charcoal/coke and salt)as required
66Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
67Supplying and fixing horizontal type feeder panel single door three pole and neutral, sheet steel, MCB distribution board 415volts, on surface/ mounted, complete with tinned copper bus bar, neutral bus bar, eart bar, din bar , interconnections, powder painted including earthing etc as required. ( with including On/Off switch & indication , 6Nos. timer, contactor, connections,etc)
68Supplying and fixing horizontal type Controling Panelsingle door three pole and neutral, sheet steel, MCB distribution board 415volts, on surface/ mounted, complete with tinned copper bus bar, neutral bus bar, eart bar, din bar , interconnections, powder painted including earthing etc as required. ( with including timer, contactor connections,etc)
69Supplying & fixing following rating 3 meter Ring Type bollard 30-40W LEDlights with 10 Amp two Pole MCB in each pole (including excavation, PCC, grouting, anchor bolting all civil works required for fixing of bollard light shall be included)
70Supplying & fixing following rating 1 meter bollard light with 12 LEDlights (including excavation, PCC, grouting, anchor bolting all civil works required for fixing of bollard light shall be included) (as per sample picture attached)
71Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
72Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
73Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
74Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
75Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
76Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 Sq.mm.
77Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , single door
78Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole (20Amps)
79Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
80Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 8 way , single door
81Supply, Installation, storing, testing and commissioning of recess mounting LED luminarie Philips make full glow light 18 W LED tube
82Supply, Installation, storing, testing and commissioning of wall mountingFan Philips/ Bajaj/ Crompton make 400 mm Dia Wall mount Fan
83Supply Installation testing commissioning of Aluminum/Stainless Steel Dandelion (spherical) outdoor fountain with sizes of Brass Ball of 8"- 12" with Aluminum / Stainless Steel Spokes of 18"-24" (length/size as per requirement of spherical pattern) with 72 -102 spokes per fountain fitted with Brass Nozzles by many branches of the small nozzle, connected in the center of the sphere, and the formation of a large radial sphere of (1.5-2m dia, with vertical fall / pipe height of 1500 mm above top/overflowing water level of inner tank). Provision of 10 HP (or higher) pump/ Pump according to the requirements of the fountain, LED coloured lights with 4 core 4 sq mm flexible copper cable for 12 RBG Lights 18 W-24 W with bubbler/foam nozzle (12 Nos in quantity) waterproof grade IP68, which can be soaked in water for a long time 24V safe voltage without electric shock hazard, stainless steel toughened glass mask used, which has strong shockproof and fall-resistant ability lamp body is made of 304 stainless steel with all G.I plumbing fittings, accessories and support made of GI pile with base plate, chemical fasteners and clamps with nut bolts for GI pipe line inclusive of painting the GI pipe with two coats of primer and two coats of anti-corrosive paint complete as required and as per the directions of Engineer in Charge. The fountain to be designed to throw the water splash radius of 2.0 meter the water body from all the nozzles (The payment for civil works shall be made under respective items.) ( Note:- Sample design is to be similar like picture or drawing attached for reference purpose ) (Summary -01 Dandelion fountain with spokes and brass nozzles, 12 foam/column jet nozzle, 12 RBG LED lights of applicable wattage, 10 HP or more pump, GI pipe fittings, SS pipe fittings including electrical fitting and electrical panel or fountain etc.)
84Supply Installation testing commissioning all arrangements for Bird Bath including minimum 1.5 meter height and 1.2-1.5 meter diametal/stone sculpture with 1.8-2 Meter dia circular shape inner tank/platform, outer tank of dia 3.5- 4 metrehaving water flow systemincluding08 Nos of Foam Jet nozzle of brass with stainless steel finish, 2” (50mm) Intel size, Spray Dia : 25 mm dia. with G.Iheader line of 2" (50 mm) with all G.I plumbing fittings, accessories and support made of GI pile with base plate, chemical fasteners and clamps with nut bolts for GI pipe line inclusive of painting the GI pipe with two coats of primer and two coats of anti-corrosive paint, 8 RBG underwater 12W - 18 W, IP68 rated different colour LED lights with 4 core 4 sq mm flexible copper cable for RBG Lights and pump, and 3.5 HP (or higher as per requirement) pump for water circulation complete as required and as per the directions of Engineer in Charge. The Bird Bath is to be designed to throw the water foam jet to uniform shape and flow 1-1.5 meter high surround the bird bath from all the nozzles (The payment for civil works shall be made under respective items.)( Note:- Sample design is to be similar like picture or drawing attached for reference purpose )