| 1 | Excavation in foundation in ordinary soil (Loam clay or sand) including lift up to 1.50m and lead up to 30m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplusearth as directed by the Engineer-in-charge upto a distance of 30m from the foundation trenches. (where machine can not reach/move |
| 2 | Filling of carted earth in plinth including supply of necessary quantity of earth from a distance not exceeding 8km from the side of work and including watering dressing etc. required for proper completion of work.(lead up to 30m & lift 1.5m) |
| 3 | Providing & laying cement concrete in 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggreagate 40mm nominal size) including supply of all materials,labour and T & P etc. required for completion of work and curing complete including cost of form work in foundation and floors |
| 4 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 5 | R.C.C.Work with cement approved coarse sand and 2 cm. in the proportions of 1:1.5:3 in Foundation including necessary centering and shuttering etc. and including supply of all materials,labour , tools & plants etc required for proper completion of work. strength of the concrete shall not beless than M-20 |
| 6 | R.C.C.Work with cement approved coarse sand and 2 cm. in the proportions of 1:1.5:3 in Plinth Beam including necessary centering and shuttering etc. and including supply of all materials,labour , tools & plants etc required for proper completion of work. strength of the concrete shall not beless than M-20 |
| 7 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 8 | R.C.C.Work with cement approved coarse sand and 2 cm. in the proportions of 1:1.5:3 in Column including necessary centering and shuttering etc. and including supply of all materials,labour , tools & plants etc required for proper completion of work.strength of the concrete shall not beless than M-20 |
| 9 | R.C.C.Work with cement approved coarse sand and 2 cm. in the proportions of 1:1.5:3 in Lintel Beam including necessary centering and shuttering etc. and including supply of all materials,labour , tools & plants etc required for proper completion of work. strength of the concrete shall not beless than M-20 |
| 10 | R.C.C.Work with cement approved coarse sand and 2 cm. in the proportions of 1:1.5:3 in Roof Beam including necessary centering and shuttering etc. and including supply of all materials,labour , tools & plants etc required for proper completion of work.strength of the concrete shall not beless than M-20 |
| 11 | R.C.C.Work with cement approved coarse sand and 2 cm. in the proportions of 1:1.5:3 in Slab including necessary centering and shuttering etc. and including supply of all materials,labour , tools & plants etc required for proper completion of work. strength of the concrete shall not beless than M-20 |
| 12 | Ist Class brick work in 1:4 cement mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 13 | Ist Class brick work in 1:4 cement mortar in super-structure above plinth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall 230 mm thick. |
| 14 | Ist Class brick work in 1:4 cement mortar in super-structure above plinth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall 115 mm thick. |
| 15 | Steel reinforcement for R.C.C. work including straightening , cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | 4 Cm (1.5\") thick 1:2:4 plain cement concreat floor eith cement , approved coarse , sand and 2 cm (1\") graded approved stone grit , laid in pannels finished with 3 mm . (1/8\") floating coat of neat cement and marble dust in ratio 5:1 as specified overincluding supply of all material , labour tool and plantetc required for proper completion of work |
| 17 | M-150 Brick on edge floor laid dry joints sand filled including preparation of base to proper slope and its ramming including supply of all materials labour and Tools and Plants etc. required for proper completion of the work. |
| 18 | 12mm thick plaster in inner walls with proportion of 1:6 cement & approved Fine sand (Smooth Face) |
| 19 | 12mm thick plaster in Outer walls with proportion of 1:6 cement & approved Fine sand (Rough Face) |
| 20 | Neat cement punning. |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 22 | Providing wall putty on new surface with approved quality material of Burger/J.K./Birla or similar make 2 coats. |
| 23 | One priming coat & one coat oil distemper on new work including supply of material, labour T&P etc. required for proper completion of the work. (Two Coat) |
| 24 | Painting or vernishing on iron work in small areas of new work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic vernish, including supply of all materials, labour and T&P etc. required for proper completion of work. |
| 25 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 26 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished Welded type tubes |
| 27 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 28 | Supply and fixing Galvanized corrugated iron roofing B.W.G. In position including Supply of all materials, labour, tools, & plants etc. required for proper completion of the work and including wastage |
| 29 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. |
| 30 | Providing and fixing on wall face PVC rain water down pipes: 100mm |
| 31 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend |
| 32 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm each |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes |
| 34 | 25 mm dia |
| 35 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 36 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. |
| 37 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. |
| 38 | Add for light / fan points with modular type switch in place of piano type switch. |
| 39 | Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. |
| 40 | Add for plug point with modular switch & socket in place of piano type switch & socket. |
| 41 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. |
| 42 | Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20mm dia. heavy duty (2mm thick) PVC conduit with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit. |
| 43 | Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in n 20mm dia heavy duty (2mm thick) PVC conduit with one number 2.5 sq. mm. multistrand copper conductor cable as earth continuity wire drawn in conduit, complete in all respect. |
| 44 | S & F surface/Flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge. |
| 45 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve CAT A |
| 46 | S&F of 63 Amp. DP MCB (10 KA) CAT A |
| 47 | Supply and fixingof LED Tube Lightwith batten suitablefor up to 1 X 22 watt LED tube light complete includingtube etc on surface complete in all respect. CAT-AA |
| 48 | Supply of Industrial Heavy Duty Wall Mounted Fan-600MM Al Blades, Aluminium Die Casted Top and Bottom with high quality copper motor(Havells Make) |
| 49 | Erection and testing of Wall-mounted industrial fan and regulator etc. excluding supply of down rod, complete in all respect. |
| 50 | Supply and burying of 600mm x 600mm x 6 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. |
| 51 | Supply & laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S Clamps Etc. of suitable size or as directed by engineer in charge, complete in all respect. 25 Sqmm 3.5 core |
| 52 | Supply & fixing of Tape off box 32 Amp to 100 Amp TPN for sandwich aluminium bus bar trunking complete in all respect. |
| 53 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia |
| 54 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia metre |
| 55 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge |
| 56 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge |
| 57 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any other pproved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge |
| 58 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of 150 mm dia |
| 59 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp |
| 60 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I) 150 mm dia |
| 61 | S/Installation of 1.00 HP submersible pump set including Electrical Panel for submersible, supporting clamps, clips etc and all other accessories required for the proper completion of the work. (V-Guard, Crompton, or KSB make) |
| 62 | Providing and fixing G.I. pipes complete with G.I. fittings 32 mm dia |
| 63 | S/laying of PVC Insulated Copper conductor cable 3 core 2.50 sqmm size for Submersible pump |