Tender For Repair To Voltage Stabilizer Ups Apfc Lt Panel Bus Bar And Other Connected Works At Ge (Af) Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Tender For Repair To Voltage Stabilizer Ups Apfc Lt Panel Bus Bar And Other Connected Works At Ge (Af) Pathankot. Submission Date for this Tender is 02-01-2024. UPS Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41049781
Corrigendum : Tender For Repair To Voltage Stabilizer Ups Apfc Lt Panel Bus Bar And Other Connected Works At Ge (Af) Pathankot
Open Tender
Indian
Punjab
pathankot
02-01-2024

Tender Details

Tender For Repair To Voltage Stabilizer Ups Apfc Lt Panel Bus Bar And Other Connected Works At Ge (Af) Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-2023 Date Corrigendum Date 02-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-

BOQ Items

Name of Work : REPAIR TOVOLTAGE STABILIZER, UPS, APFC, LTPANEL, BUS BAR AND OTHER CONNECTED ITEM ATGE (AF) PATHANKOT
Sl. No. Item Description
1Checking of unservicable Voltage /UPS/Inverter any type and capacity and find the faulty part including disconnecting electric connection of voltage stablizer opening voltage stablizer /UPS/Invertor and including minor repairup to 400KVA 3 phase 415 voltsfor unbalanced load complete all as specified and directed by Engineer-in-charge.(additional items required to make stabilizer serviceable will be measured separtely under resepctive items).
2Material and labour in replacement if required digital Ampermeter range form 0-500 AmpAC230 Volt with CTas per site complete all as specified and directed by Engineer-in-charge.
3Material and labour in replacement if required printed control card circuit suitable of capacity 25 KVA to 50 KVA voltage stabilizers any Cap complete all as specified and directed by Engineer-in-Charge.
4All as per item No 3 above but 50 KVA to 100 KVA complete all as specified and directed by Engineer-in-Charge.
5All as per item No 3 above but 100 KVA to 200 KVA complete all as specified and directed by Engineer-in-Charge.
6All as per item No 3 above but 200 KVA to 400 KVA complete all as specified and directed by Engineer-in-Charge.
7Material and labour in replacement if required in replacement holder for printed control card circuit suitable for any make voltage stabilizer including connections by soldering all as required or directed by Engr-in-Charge.
8Material and labour in replacement if required in replacement limit switch suitable to cut off supply to synchronous motors on high and low set limits as per sample complete all as specified and directed by Engineer-in-Charge.
9Material and labour in replacement if required in replacement toggle switch 2 way 5 amps 230 volts including connecting electrically complete all as specified and directed by Engineer-in-Charge.
10Material and labour in replacement if required synchronous motor single phase AC 230 volts suitable to work with voltage stabilizer upto 50 KVA cap with torque 3 Kg/ CM complete all as specified and directed by Engineer-in-Charge.
11All as per item No 12 above but suitable for voltage stabilizer abvoe 50 KVA upto 200 KVA capacity of existing makewith torque 3 Kg/ cm complete all as specified and directed by Engineer-in-Charge.
12All as per item No 12 above but suitable for voltage stabilizer abvoe 200 KVA upto 400 KVA capacity of existing makewith torque 3 Kg/ cm complete all as specified and directed by Engineer-in-Charge.
13Material and labour in replacement if required in replacement indicator with bulb,red, yellow or green 230 volts as per samble complete all as specified and directed by Engineer-in-Charge.
14Material and labour in replacement if required in repalcemement control transformer with primary voltage 230 volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer as per sample complete all as specified and directed by Engineer-in-Charge.
15Material and labour in replacement if required in replaceement selector switch 6 position suitable for 3 phase 4 wire supply system 415 volts AC for ammeter or voltmeter of existing make complete all as specified and directed by Engineer-in-Charge.
16Material and labour in replacement if required in repalcement push button any type and size as per sample, suitable to operate the synchronous motor manually complete all as required at site and directed by Engr-in-Charge.
17Material and labour in replacement if required in replacement variable resistance (pre set) with lock nuts suitable for fine adjustement of output voltage on auto mode complete all as specifed and directed by Engr-in-Charge.
18Material and labour in replacement if required in replaceemnt capacitor of rating 1 to 2 mfd 230 volts complete all as required at site and directed by Engr-in-Charge.
19Material and labour in replacement if required in replacement resistance for synchrmous motor assy rating upto 1 K ohm 10 watt + 10% complete all as required at site and directed by Engr-in-Charge.
20Material and labour in replacement if required in repalcement dimmer stat suitable for voltage stabilizer of any cap upto 25 KVA of any make to match with existing system complete all as specified and directed by Engr-in-Charge.
21All as per item No 22 here in before but above 25 KVA upto 50 KVA complete all as specified and directed by Engr-in-Charge.
22All as per item No 22 here in before but above 50 KVA upto 100 KVA complete all as specified and directed by Engr-in-Charge.
23All as per item No 22 here in before but above 100 KVA upto 200 KVA complete all as specified and directed by Engr-in-Charge.
24All as per item No 22 here in before but above 200 KVA upto 400 KVA complete all as specified and directed by Engr-in-Charge.
25Material and labour in replacement if required carbon brush with holder as per sample suitable for voltage stabilizer of any make any cap upto 50 KVA complete all as specified and directed by Engr-in-Charge.
26All as per item No 27 above but cap above 50 KVA upt 200 KVA complete all as specified and directed by Engr-in-Charge.
27All as per item No 27 above but cap above 200 KVA up to 400 KVA complete all as specified and directed by Engr-in-Charge.
28Taking out main transformer of the voltage stabilizer for repair/ rewinding. Rewinding of the main transformer using super enameled copper winding wire of existing gauge including latherire paper, PVC sheets, sleeves etc all as required. Varnishing complete with insulating varnish,drying and refixing to the stabilizer after testing all as required at site and directed by Engr-in-Charge.
29Material and labour in replacement if required in repalcement brass studs with nuts, washers etc complete including porcelain bushes as per sample suitable for voltage stabilizers above 25 KVA upto 50 KVA cap any make all as required at site complete all as specified and directed by Engineer-in-charge.
30All as per item No 31 above but50 upto 100 KVA complete all as specified and directed by Engr-in-Charge.
31All as per item No 31 above but100 upto 200 KVA complete all as specified and directed by Engr-in-Charge.
32All as per item No 31 above but200 upto 400 KVA complete all as specified and directed by Engr-in-Charge.
33Supply/ Fix AC coilsuitable for Power contactor70 to 110 Amp exciting voltage 240/415 Volt as per site complete all as specified and directed by Engineer-in-charge.
34Material and labour in replacement if requiredoperating coil of voltage 230 Volts for air break contactor from 200 Ampsto 400 Amps all as required at site complete all as specified and directed by Engineer-in-charge.
35Material and labour in replacement if requiredoperating coil of voltage 230 Volts for air break contactor up to 110 Amps all as required at site or complete all as specified and directed by Engineer-in-charge.
36Material and labour in replacement if requiredoperating coil of voltage 230 Volts for air break contactor up to 250 Amps all as required at site or complete all as specified and directed by Engineer-in-charge.
37Supply and Fixingof single Phase invertor including taking out unserviceable controll wiring, rechanging card complete all as specified and directed by engineer-in-Charge.
38Material and labour in replacement if requireding in replacement maintenance free dry type battery of cap 65 to 70 Ah 12 volts complete with connection to UPS as complete all as specified and directed by Engineer-in-charge.
39Checking wiring to the APFC control panel including fault circuitwithcopper conductor cable PVC insulated of size 1.00 sqmm/ 1.5 sqmmor as existing earlier complete including setting of control to display of voltage , current , Active power , reactive power , apparent power power , alarm indication for defective steps , low power factor and excess temperature ,complete all as specified and directed by Engr-in-Charge.
40Supplying and fixingin replacementAPFC relays up to 7 stage complete all as specified and directed by Engr-in-Charge.
41Supplying and fixingin replacement digital frequency meter 04 digit flush Mfd 96 Sqmm size for frequency range 30 to 19.99 Hz with built in transducer complete all as specified and directed by Engr-in-Charge.
42Supplying and fixing in replacement digital power factor meter 440 volts 5 amps with built in transducer flush complete all as specified and directed by Engr-in-Charge.
43Supplying and fixingin replacementcapacitor for APFC panel 440 V olt 3 phase as per site requirment up to 5 KVA complete all as specified and directed by Engr-in-Charge.
44Supplying and fixing in replacementcapacitor for APFC panel 440 V olt 3 phase as per site requirment up to 12.5KVA complete all as specified and directed by Engr-in-Charge.
45Supplying and fixing in replacementcapacitor for APFC panel 440 V olt 3 phase as per site requirment up to 20 KVA complete all as specified and directed by Engr-in-Charge.
46Supplying and fixing in replacementcapacitor for APFC panel 440 V olt 3 phase as per site requirment up to 25KVA complete all as specified and directed by Engr-in-Charge.
47Supplying and fixing in replacementcapacitor for APFC panel 440 V olt 3 phase as per site requirment up to 50 KVA complete all as specified and directed by Engr-in-Charge.
48Supplying and fixing top up of insulating oil conforming to IS 335 -1993 latest amendmentsfor replacing the oil in stablizers with breaking capacity not less than 45kv complete all as specified and directed by Engr-in-Charge.
49Dehydration including filteration and cleaning of stabilizer oil at different locations by stream line method dehydration plant including testing of samples before and after dehydration and filteration . Dielectric strength should not be less than 45 KV at 2.5 mm gap after dehydartion complete all as specified and directed by Engr-in-Charge. Note :- (i)Test resultbefore and after filteration to berecorded as perthe sample provided by Engr-in-charge. (ii)The rate quoted is deemed to be inclusive of making necessary connection and the connection to filteration plant from transformers and switchgear oil duly removing the inlet and outlet connections. (iii)For topping up transformer oil will be measured and paid separately under relevent item of schedule.
50Scraping of old paint from the Stablizer any type and capacity and paint of complete stablizerby applying two coat of synthetic enamelpaintof approved colour complete all as required at site or complete all as specified and directed by Engineer-in-charge.
51Supply, installation, testing and commissioning in replacement of LT feeder pillar box cubical type 440 Volts 3 phase 4 wire outdoor type front operated with adequate Air Ventilation at both sides & back & fabricated out 3.15 thick CRCA sheet with double door shutter with locking arrangment with water proof dust & vermin proof, pre fabricated hinges for rear & front door with locking arrangement complete with inter connection with copper wire / strip, tapping bonding to earth & all frames inner & outer door shall be coated by polyster powder paint of shade RAL 7032 siemens grey stand of distribution board shall be coated by primer & black Bituminous paint, cable trays, cable lugs, cable Glands of any size with suitable to accommodate and including following mentioned fittings & fixture with suitable nut, bolt, washer etc CPRI approved including provision for taking out cable duly marked revetted letter at appropriate size for each feeder cable & reconnection with duly insulated cable terminals with heat shirnkable sleeve with 1.1 KV grade Danger noticeboard etc (i) Bus bar chamber consisting four Nos Aluminium busbar of capacity 400 Amp duly insulated with heat shrinkable sleeve 1.1 kv grade with RYBN mounted on heavy duly Epoxy insulator in separate compartment. (ii) Digital type volt meter 01 No. and Digital type Amp meter - 01 No. (iii) LED indicating lamp (RYB) for incoming and outgoing feeder with controlled with 2 Amp MCB single pole "C" curve. (iv)Panel board internal wiring with suitable PVC insulated multistranded copper conductor cable flexiable cable . (v) Two Nos selector switch for controlling volt meter and ammeter Note:- (i)Excavation & earth work required for taking out cable of any length & re-laying cable all terminal/bare conductor deemed to be included in the quoted rate.(ii) PCC foundation platfrom & grouting 4 legs of feeder pillar box 45 cm below gound level deemed to be included in the quoted rate (iii) The LT feeder pillar shall be made to accomodate the following switch gear MCCBs. INCOMING : (i) MCCB, 4 pole, 415 Volt, 200Amps capacity with 25 KA with adjustable thermal magnetic trip unit/release with Ics= 100% Icu qty 01 No. OUTGOING (i)MCCB, 4 Pole , 415 Volt, 63Amps - 4 Nos
52Material & Labour for Servicing to Indoor/outdoortype LTpanel board single/ double door withcanopy by (i) Cleaning with blower, (ii) Cleaning with CTC/Petrol (iii) Replacement of damaged lugsif any(iv) Replacement of deteriorated copper wiring (v) Cleaning and tightening of MCCB terminal connections(vi) Replacement of sheared rubber beadings (vii) Rectifying of loose connections (viii) Replacement of door shutters of suitable size ,with 3.15mm thick CRCA sheet incl locking arrangement , door hinges- 2 nos .(ix) writing feeder name with white paint on all incoming and outgoing feeders includingtwo coats of synthetic enamel paint over a coat of red oxide complete with existing colour allas shown complete all as specified & directed by Engr-in-Charge.
53Supply and fix 63 Amps MCCB bus bar chambers factory febricated suitable for 3 Phase & neutraliron clad with 4 Nos 100 amp rated copper strips , with two Nos Earthing connection bolt with locking arrangement front door operated complete fixed flush in wall and making good the disturbed wall surfaces complete all as a requiredat site or directed.
54Material & Labour for Servicing to Indoor/outdoortype LT busbarsingle/ double door withcanopy by (i) Cleaning with blower, (ii) Cleaning with CTC/Petrol (iii) Replacement of damaged lugsif any(iv) Replacement of deteriorated copper wiring (v) Cleaning and tightening of MCCB terminal connections(vi) Replacement of sheared rubber beadings (vii) Rectifying of loose connections (viii) Replacement of door shutters of suitable size ,with 3.15mm thick CRCA sheet incl locking arrangement , door hinges- 2 nos .(ix) writing feeder name with white paint on all incoming and outgoing feeders includingtwo coats of synthetic enamel paint over a coat of red oxide complete with existing colour allas shown & directed.
55Supply & Fixing in replacment of 3 phase digital multi function meter with suitable accessories and fixing arrangements complete all as specified and directed by Engr-in-Charge.
56Supply & Fixing in replacement of selector switch suitable for 415volts complete all as specified and directed by Engr-in-Charge..
57Supply & Fixing in replacment of voltmeter of range 0 to 500 Volts complete all as specified and directed by Engr-in-Charge.
58Supply & Fixing in replacament of LED type phase indicator to be fitted on panel ( R,Y , B as per site requirement) complete all as specified and directed by Engr-in-Charge.
59Supply, installation, connecting & testing cubical outdoor type factory made double door , powder coated LT bus bar feeder pillar box for 150 amps 3ph and neutral arrangement of size 500mmx500mmx200mm complete weather proof and verminproof conforming to IP-54 made out of 2mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS.It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45mtrs above GL and 0.30mtrs below ground including required PCC for foundation and coping complete all as specified and direc ted by Engr-in-Charge.
60Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness3.15mm front and backdoor openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.0 mtr long , 0.7 mtr above ground level and 0.30 mtr embedded in PCC blocks of size 0.30x0.30x0.30 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 400 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators and MCCB 200 AMP,35 KA, 4 Pole 415 V make Legrand,complete all as specified and direc ted by Engr-in-Charge.
61Supply & fixingheat srink cablejointingkitfor 1.1 KV grade cablefor straight throughjoint/ end joint kitcompletewithjointingmaterial andaccessoriessuitablefor 2/3.5/4core XLPE/ PVCarmouredAIuminium Conductorcableoffollowing size . complete all as specified and direc ted by Engr-in-Charge. (a) 16 sqmm to 35 sq mm
62All as per item No 63 here in before but 50 sqmm to 95 sq mm complete all as required at site or directed by Engr-in-charges.
63All as per item No 63 here in before but120sqmm to 185 sq mm complete all as required at site or directed by Engr-in-charges.
64All as per item No 63 here in before but 240 sqmm to 300 sq mm complete all as required at site or directed by Engr-in-charges.
65Supply/ Installing testing & commissioning of street Light Pole Boxtwo no Aluminium Bus Bar of capacity 63 amp including 6 Amp SP MCB.The Box should have auto Door lock facility with magnetic lock having size 260X120X230 mm and fixed to poles/ Wall usingand nuts & bolts of required size complete all as required at site or directed by Engr-in-charges.
66M & L for PVC insulated sheathed aluminium stranded conductor cable of size 6 sqmm twin core fixed / hang properly at directed location by using suitable mounting / fixing arrangements viz PVC clamps/saddles,connecting complete all as specified and directed by Engr-in-Charge.
67Earthingcompletewith galvanisedsteelearthplateelectrode 600x600x6mm burrieddirectlyin groundnotless than2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.5mtrbelow normal ground level connected to the Galvanised iron lead of 4 mm diasizeby meansof bolts ,nuts,check nutsandwashersof galvanisediron and 4 mm GI wire procted by provision of GI light grade pipe 15 mm boreincl provision of concrete pit in PCC1:2:4 typeB-i, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPMweight not less than 4 Kg /Sqm and 6mm diabar handle ,excavationand earthworkin any type of soil ,charcoaldustand saltlightgrade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GIprotectionpipe 15mm bore 5 Mtr long and GI wire upto main earthingof polecomplete all as shown in electrical plateNo 5 of MES Sch 2009 Part-I all as specifiedand directed .
68Earthingcompletewith galvanisedsteelearthplateelectrode 600x600x6mm burrieddirectlyin groundnotless than2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.5mtrbelow normal ground level connected to the Galvanised iron strip 32x6mm sizeby meansof bolts ,nuts,check nutsandwashersof galvanisediron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm boreincl provision of concrete pit in PCC1:2:4 typeB-i, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPMweight not less than 4 Kg /Sqm and 6mm diabar handle ,excavationand earthworkin any type of soil ,charcoaldustand saltlightgrade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GIprotectionpipe 15mm bore 5 Mtr long and GI strip upto main earthingof polecomplete all as shown in electrical plateNo 5 of MES Sch 191 Part-I all as specifiedand directed . On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
69Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness3.15mm front and backdoor openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.5 mtr long , 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 400 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators andS & F MCCB 250 AMP,35 KA, 3 Pole 415 V make Legrand,all as specified and direc ted by Engr-in-Charge.
70Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness3.15mm front and backdoor openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.5 mtr long , 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 400 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulatorsall as specified and direc ted by Engr-in-Charge.
71Supply and fixing dry type maintenance free battery of capacity12 Volt 70 AH complete all as specified and directed by Engr-In-Charge.
72Supply and fixing 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA in a suitable size of sheet metal enclosure with locking arrengementfor grouting / mounting on wall at a suitable distance with complete all as specified and directed by Engr-In-Charge.
73Supply and fixing ON LOAD handle operated change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed by the Engineer-in-Charge.
74Supply and fixing ON LOAD handle operated change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps complete all as specified and directed by the Engineer-in-Charge.
75Supply and fixingON LOAD front handle operated change over switch 415V in sheet metal enclosures 4 pole of capacity 320 Amps complete all as specified and directed by the Engineer-in-Charge.
76Supply and fixingON LOAD front handle operated change over switch 415V capacity 630 Amps complete all as specified and directed by the Engineer-in-Charge.
77Earthingcompletewith copper earth plate electrode 600x600x 3.15 mm burrieddirectlyin groundnotless than2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.25 Mtrbelow normal ground level connected to the copperstrip 20x3 mm sizeby meansof bolts ,nuts,check nutsandwashersof galvanisediron and 20x3 mm copper strip procted by provision of GI light grade pipe 40 mm boreincl provision of concrete pit in PCC1:2:4 typeB-i, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPMweight not less than 4 Kg /Sqm and 6mm diabar handle ,excavationand earthworkin any type of soil ,charcoaldustand saltlightgrade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GIprotectionpipe 15mm bore 5 Mtr long and GI strip upto main earthingof polecomplete all as shown in electrical plateNo 5 of MES Sch 191 Part-I complete all as specifiedand directed by Engr-in-Charge . (i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shalldeem to be included in the unit rate quoted against this item . (ii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
78Supply and fixingLT cable jointing kit for 1100 V grade cable forstraight throughheatshrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 50-95Sq mm 3.5 core complete all as specifiedand directed by Engr-in-Charge .
79Supply and fixing LT cable jointing kit for 1100 V grade cable forstraight throughheatshrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 120-240Sq mm 3.5 core complete all as specifiedand directed by Engr-in-Charge .
80Supply and fixing LT cable jointing kit for 1100 V grade cable for endheatshrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 50 - 95Sq mm 3.5 corecomplete all as specifiedand directed by Engr-in-Charge .
81Supply and fixing LT cable jointing kit for 1100 V grade cable for endheatshrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 120-400Sq mm 3.5 core complete all as specifiedand directed by Engr-in-Charge .
82Supply, installation, commissioning and testing CPRI approved LT panel outdoor type of size 1.00x1.00 x0.50 Mtr orsuitable size as recommended by manufacturercubical floor mounted type (IP-65 degree of protection ) made out of 3.15 mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulatorsfor 3 phase 4 wire 415 volts 50 HZ AC supply incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including the following (i)MCCB 4 pole 415 volts 160 amp rating thermal magnetic release with rupturing capacity 25 KA -01 No as incomer , Make-Legrand /Siemens 3VL/Schneider NSX (ii) MCB SPN 63 Amps, 10 KA C curve- 04 Nos. Make: Legrand (iii)Air break contactor AC 415 volts, 50 HZ 3 phase, 110 A AC1 with operating coil voltage 220 volts - 01 No (iv) Indicator set LED RYB -01 Set of 3 pcs (v) Toggle switch of 5 Amp, 230 Volts for auto/manual operation - 01 No (vi) Multifunction digital Astro Rex D-21, connecting electrically using copper conductor cable. (vii) Change over switch of 200 Amp, 4 pole - 01 No for bypass arrangement (viii) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio Make- Schneider cat no. 30002567 or equilent/ L & T / Legrand (ix) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
83Supply, installation, commissioning and testing CPRI approved LT panel outdoor type ofsuitable size as recommended by manufacturercubical floor mounted type (IP-65 degree of protection ) made out of 3.15 mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated,and mounted on epoxy based post insulatorsfor single phaseAC supply incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates suitable for and including 250 Amp bus bar the following complete all as specified and directed by Engr-in-Charge (i) MCCB125 Amps, 10 KA C curve- 04 Nos. Make: Legrand (ii)Air break contactor AC 415 volts, 50 HZ 3 phase, 70 A AC1 with operating coil voltage 220 volts - 01 No (iii) Toggle switch of 5 Amp, 230 Volts for auto/manual operation - 01 No (iv) MCB Change over switch of 40 Amp, SP - 01 No for bypass arrangement (v) All accessories prewired with suitable size copper conductor cable or strip including foundation all as required and directed.
84Supply and fix copper strip 20x3.15 mm complete with saddles/ insulators made out of porcelain or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints complete all as specified and directed by Engr In Charge.
85Supply laying and testing cable PVC insulated screended PVC bedded , galvanised steel striparmoured, electric power cables (heavy cable ) with stranded copper conductor , 1100 Volts grade of size 1 core95 Sqmm complete all as specified and directed by Engr In Charge.
86Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel striparmoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 1 core 240 Sqmm complete all as specified and directed by Engr In Charge.
87Scraping of old paint from the steel tubular pole with out removing accessories and preparationof surfaces for repainting . Repainting the pole with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining pole and clamps GI bkt etc above 1.5 mtr height by applying one coat of alumn paintall as required at site or directed.
88Scraping of old paint from the LT three phase bus bar chamber of any size fixed on channel without removing and preparation of surfaces for repainting externally by applying two coat of synthetic enamel powder coated of approved colour complete all as required at site or directed. Make of Paint : Asian
89Supply & fixing MCCB 3 pole 415 volts with rupturing cap 25 KA 400 Amps thermal magnetic release complete all as specified and directed by Engr In Charge.
90Supply & fixing MCCB 3 pole 415 volts with rupturing cap 25 KA 250 Amps thermal magnetic release complete all as specified and directed by Engr In Charge.
91Supply & fixing MCCB 3 pole 415 volts with rupturing cap 25 KA 200 Amps thermal magnetic release complete all as specified and directed by Engr In Charge.
92Supply & fixing MCCB 3 pole 415 volts with rupturing cap 25 KA 160 Amps thermal magnetic release complete all as specified and directed by Engr In Charge.
93Supply & fixing MCCB 3 pole 415 volts with rupturing cap 25 KA 100 Amps thermal magnetic release complete all as specified and directed by Engr In Charge.
94Supply & fixing MCCB 3 pole 415 volts with rupturing cap 25 KA 63 Amps thermal magnetic release complete all as specified and directed by Engr In Charge.
95Excavation in trenches in any type of soil exc 1.5 Mtr in width and not exc 1.5Mtr in depth and getting outfor laying of cable all asrequired and directed at site complete all as specified and directed by Engr In Charge..
96Returning filling in, including spreading leveling,watering and well ramming in layers not exc 1.5cm each layer complete all as specified and directed by Engr In Charge.
97Removal of surplus soil to distance not exc 50mtr and depositing where directed at level not exc1.5 mtr above the starting point complete all as specified and directed by Engr In Charge.
98M& Lfor sand cushioning to underground cable 8cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and directed by Engr In Charge.
99Material & Labour for sub class “B” bricks laid dry flat cover the cablewith width equal to the length of cable, abutting each other for protection of cable complete all as specified and directed by Engr In Charge.