Kerala State Rural Roads Development Agency has published Tender For Periodical Maintenance Of Road - Pradhan Mantri Gram Sadak Yojana 2022-2023Kallumukku-Kazhambu-Puthankunnu Road Package No. Kr-14-31Sulthan Bathery Block, Wayanad District Including Maintenance For Five Years After Completion. Submission Date for this Tender is 16-12-2023. Road Repair Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | KALLUMUKKU-KAZHAMBU-PUTHANKUNNU ROAD (5.121km) |
2 | CLEARING AND GRUBBING |
3 | Clearing Grass and Removal of Rubbish - Clearing grass and removal of rubbish upto a distance of 30m outside the priphery of the area as per technical specification Clause 200.1 |
4 | PAVEMENT COMPONENTS |
5 | Scarifying Existing Bituminous Surface to a depth of 150mm - by Mechanical Means - Scarifying the existing bituminoussurafce to a depth of 150mm and disposal of scarified material with a lift upto 3m and lead upto 1000m as per technical specification Clause 301.4.1 |
6 | Dismantling flexible Pavements- Dismantling of flexible Pavements and disposal of dismantled material upto a lead of 100m, stacking serviceable and unserviceable materials seperately by Mechanical means as per technical specification Clause 202.3 - Bituminous coursess |
7 | Excavation in soil using Hydraulic Excavator and Tippers with disposal upto 1000m- Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location with a lift upto 1.5m and lead upto 1000mas per technical specification Clause 302.3 |
8 | Construction of embankment with material obtained from Roadway cutting - Construction of embankment with approved material deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300.1 and 300.2 as per technical specification Clause 301.5 |
9 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, loading and unloading, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
10 | Haulage excluding loading and unloading of materials by tipper |
11 | Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2. |
12 | Supplying, providing and laying woven Coir Geotextile fabric (coir fiberhaving 2.00 Metre minimum width of H2M5 grade and density .740kg/Sqm) in wrap directionof the embankment with suitable laps o prepared sub grade rolled to 100% of M.D.D as directed by the departmental officers at site. COIR Type 3 Vycome coir yarn from chainage 2/990 to 3/683 |
13 | Construction of Subgrade and Earthen Shoulder- Construction of of subgrade and earthen shoulders with approved material obtained from borrow pits with all leads and lifts transporting to site, spreading, grading to required slope andcompacting to meet requirement of Table300.2with lead upto 1000m as per technical specification Clause 303.1 |
14 | Haulage excluding loading and unloading of materials by tipper |
15 | Granular Sub-base with well graded material (Table 400.1)-By Mix in Place Method- For Grading I material -Construction ofgranular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotovator at OMC, and compacting with smooth wheel roller to achieve the desired density as per technical specification Clause 401 - Using departmental material |
16 | Granular Sub-base with well graded material (Table 400.1)-By Mix in Place Method- For Grading I material -Construction ofgranular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotovator at OMC, and compacting with smooth wheel roller to achieve the desired density as per technical specification Clause 401 |
17 | Granular Sub-base withlocal material (Table 400.13)-By Mix in Place Method- Quarry muck -Construction ofgranular sub-base by providing local material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotovator at OMC, and compacting with smooth wheel roller to achieve the desired density as per technical specification Clause 401.4 as per technical specification clause 408 |
18 | Breaking of 100 mm aggregate obtained from dismantling of flexible pavement in to specification |
19 | Water Bound Macadam Sub-base / Base- WBM Grading II- By Mannual means - providing, laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, stone screenings/ binding material to fill up the interstices of course aggregate, watering and compacting to the required density grading 2 as per technical specification Clause 404 |
20 | Water Bound Macadam Sub-base / Base- WBM Grading III- By Mannual means - providing, laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, stone screenings/ binding material to fill up the interstices of course aggregate, watering and compacting to the required density grading 3 as per technical specification Clause 404 |
21 | BITUMINOUS WORKS |
22 | Prime Coat - Low porosity-providing and applying primer coat with bitumen emulsion (Packed SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at a rate of 0.70 - 1.00 kg/sqm using mechanical means as per technical specification clause 502 |
23 | Providing and laying surface dressing as wearing course consisting of a layer of bitumen emulsion laid on the prepared surface, followed by a cover of crushed stone chippings of specified size and rolling with 80-100 kN roller including cleaning the road surface as per Technical Specification Clause 507. ( By Mechanical Means, Case – I: Nominal chipping size 13.2 mm)Bitumen Emulsion Packed |
24 | Providing and laying surface dressing as wearing course consisting of a layer of bitumen emulsion laid on the prepared surface, followed by a cover of crushed stone chippings of specified size and rolling with 80-100 kN roller including cleaning the road surface as per Technical Specification Clause 507. (By Mechanical Means, Case –II: Nominal chipping size 6.3 mm) Bitumen Emulsion Packed |
25 | Pre-Coating Chips- Pre-coating of chips with 1 per cent of paving bitumen by weight of chips in a suitable mixer duly heated to 160 degree C as per Technical Specification Clause 507.2.5 |
26 | Cement Concrete Pavement - Construction of un-reinforced dowel jointed at expansion and construction joint only,plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 30 (grade),coarse and fine aggregates conforming to IS383,maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork spreading the concrete with showels,rakes,compacted using needle, screed, and plate vibrators and finished in continuous operation including provision of contraction and expansion ,construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge /culvert and construction joints, admixtures as approved,curing of concrete slabs for 14 days,using curing compoundand water finishing to lines and grade as per drawing and TechnicalSpecifications clause 1501 |
27 | CD WORKS |
28 | Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202 (Upto 600 mm dia) |
29 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.Ordinary soil : Upto 3 m depth |
30 | PCC Grade M 10 - Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:3:6 |
31 | Providing and Laying RCC pipe NP3 as per design in single row -Providing and laying RCC pipe NP3 culverts on first class bedding of granular material in single row with cement mortar 1:2 but excluding excavation, protectio works, backfilling, concrete and masonry works in head walls and parapets as per technical specification clause 1106 : 1000mm Dia |
32 | Providing and Laying RCC pipe NP3 as per design in double row -Providing and laying RCC pipe NP3 culverts on first class bedding of granular material in doublerow with cement mortar 1:2 but excluding excavation, protectio works, backfilling, concrete and masonry works in head walls and parapets as per technical specification clause 1106 : 1000mm Dia |
33 | PCC Grade M 15 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2.5:5 |
34 | PCC Grade M 20 - Providing concrete for plain/reinforced concrete for wearing coat complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2:4 for catch pit |
35 | RCC Grade M 25 - Providingand laying reinforced cement concrete in superstructure complete as per drawings and technical specifications Clause 800, 1205.4 and 1205.5 -upto 5.00mtr Height(PCC M25 for culvert Parapet) |
36 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(600 mm ) |
37 | Painting two coats including primer coat after filling the surfacewith synthetic enamel paint in all shades on new,plastered surface as per drawing and technical specification |
38 | TRIPPLE CELL BOX CULVERT |
39 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.Ordinary soil : Upto 3 m depth |
40 | Bailing out water by using 5HP engine and pumpset including all conveyance to site, errection, cost of fuel, lubricating oil and other stores, pay of staff etc. Complete |
41 | COCONUT PILES- Supplying and stacking well matured straight coconut posts for driving down through various strata below bed level including, cost conveyance etc. complete |
42 | COCONUT PILES- Driving Downcoconut piles to lines and levelsthrough various strata including all hire charges and labour for fixing , staging platform and all other appliances necessary for pile driving after pointing bottom end etc. complete |
43 | Filling in Foundation Trenches with Quarry Muck- Suppying and filling quarry muck in foundation trenches of culvert or other structures for stabilizing the top clay layer including watering, consolidation and dressing etc complete for improving the bearing capacity of soil. |
44 | PCC Grade M 10 - Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:3:6 |
45 | RCC Grade M 25 - Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- |
46 | Supplying, fitting and placing TMT bar reinforcement in foundation - complete as per drawings and technical specifications Clauses 1000 and 1202 |
47 | RCC Grade M 25 - Providingand laying reinforced cement concrete in substructure complete as per drawings and technical specifications Clause 800, 1205.4 and 1205.5 -upto 5.00mtr Height |
48 | Supplying, fitting and placing TMT bar reinforcement in substructure - complete as per drawings and technical specifications Clauses 1002, 1005,1010 and 1202 |
49 | RCC Grade M 25 - Providingand laying reinforced cement concrete in superstructure complete as per drawings and technical specifications Clause 800, 1205.4 and 1205.5 -upto 5.00mtr Height |
50 | Supplying, fitting and placing TMT bar reinforcement in substructure - complete as per drawings and technical specifications Clauses 1002, 1010 and 1202 |
51 | PVC WHEEP HOLES - Providing weep holes using 75mm dia PVC pipes 4 kg/sq cm including cost of material , labour charges etc. complete |
52 | RING BUND Type - 1 - Putting up of ring bund as per approved shape 2.50 m bottom width, 1.00 m top width and average height of 2.00 m using empty gunny bag/ Polythene bags filled with earth placed in 2 rows at 0.6m apart and filled in between with puddle clay to form bund including labour charges for dismantling the bund after completion of the work etc complete. |
53 | Painting Two coats on New Concrete Surfaces - Painting two coats icluding primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and technical Specification |
54 | PROTECTION WORKS |
55 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. - ordinary soil up to 3m height |
56 | DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site |
57 | RCC Grade M 20 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203-upto 5.00m Height |
58 | PCC Grade M 20 - Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2:4 |
59 | Supplying, fitting and placing TMT bar reinforcement in substructures - complete as per drawings and technical specifications Clauses 1000 and 1202 |
60 | Guard Stones- Reinforced cement concrete M15 grade guard stonesof size 20x20x120cm size embedded in PCC 1:4:8 block of 45x45x45cm sice with 30cm embedding of stones including painting etc. complete. |
61 | Supplying and fixing M15 guard stone of size 0.9x0.20x0.20 M at suitable locations including painting two coats with primer, etc. complete as per drawings and technical specifications. |
62 | DRAIN WORKS |
63 | Surface Drains in Soil- Construction of unlined surface drains of average cross sectional area 0.40sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3.0m and lead of 50m as per technical specification Clause 307 - By Mannuall Means |
64 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.ordinary soil up to 3m height |
65 | PCC Grade M 10 - Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:3:6 |
66 | PCC Grade M 15 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2.5:5 |
67 | PCC Grade M 20 - Providing concrete for plain/reinforced concrete for wearing coat complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2:4 |
68 | RCC Grade M 20 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203-upto 5.00m Height |
69 | Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202(For foot slab) |
70 | TRAFFIC SIGNS, MARKINGS AND OTHER APPURTENANCES |
71 | Providing and Fixing "Logo" of PMGSY Project - Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
72 | Providing and Fixing typical PMGSY citizens information board as per MoRD specifications and drawings-Two vertical76.1mm outer diameter MS sheet tube posts of 3.60mm thickness (medium class)duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x750mm, 600mm below ground level with two horizontalM S Sheet Tubesof 1000mm length to make the frame of board, four horizontals and two verticalswith M S Sheet rectamngular Tube 50x25x2mm to make the frame to fix the board as per drawing, two M S Sheet 2.00 mm thick boards of size 900x750mm strengthened by 25mmx5mm MS flat iron includingpainting with stove enameled paint on both sides as per MoRD specifications. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
73 | Providing and Fixing typical PMGSY Maintenance information board as per MoRD specifications and drawings-Two vertical76.1mm outer diameter MS sheet tube posts of 3.60mm thickness (medium class)duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x750mm, 600mm below ground level with two horizontalM S Sheet Tubesof 1000mm length to make the frame of board, four horizontals and two verticalswith M S Sheet rectamngular Tube 50x25x2mm to make the frame to fix the board as per drawing, two M S Sheet 2.00 mm thick board of size 900x1500mm strengthened by 25mmx5mm MS flat iron includingpainting with stove enameled paint on both sides as per MoRD specifications. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
74 | Retro-reflective Traffic Signs - Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701- 900mm equilateral triangle board |
75 | Providing and fixing of retro-reflectorised logo board at different locations of roadasper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701- 600mm x 600mmsize logo and sign board of 1100x300mm |
76 | Traffic Signs- Direction and place identification sign upto 0.90 sqm size board - Retro - reflective Traffic Signs -Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701. |
77 | Traffic Signs- Retro-reflective Traffic Signs - Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701- 600mm x 450mm rectangularboard |
78 | Kilometre Stone- Reinforced cement concrete M15 grade kilometre stone / local stone of standard design as per IRC:8 fixing in position including painting and priming etc.as per drawing and technical Specification clause 1703 - OrdinaryKilometre stone (pre-cast) |
79 | Hectometre Stone- Reinforced cement concrete M15 grade Hettometre stone / local stone of standard design as per IRC:8 fixing in position including painting and priming etc.as per drawing and technical Specification clause 1703 - 200m stone (pre-cast) |
80 | Supplying and fixing RCC M15 boundary stone of size 60x20x20 CMS. and embeded in CC. 1:4:8 block of size0.45 x0.45x0.45 m. plastering, painting, etc. complete. |
81 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
82 | Total Construction cost |
83 | Maintenance for 5 years |
84 | Maintenance for first Year after completion |
85 | Maintenance for second Year after completion |
86 | Maintenance for third Year after completion |
87 | Maintenance for fourth Year after completion |
88 | Maintenance for fifth Year after completion |
89 | Total Maintenance cost |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail