| 1 | Earthwork in excavation in foundation trenches in ordinary soil(vide classification of soil item - A ) and disposal of excavated earth as obtained to a distance upto 50 M. including all lift, levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I. |
| 2 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mmthick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 3 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-lll) : 6 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-lll) : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specificationand direction of E/I. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-lll) : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-lll) : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 150landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-lll) : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Providing designation 75 B brick work in C.M. (1:6) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, costs of screening materials, scaffolding, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 150landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-lll) : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-lll) : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 14 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 15 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 16 | Providing 12 mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 17 | White washing three coats over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales smoke and mosh marks with jhama rubbing, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I. |
| 18 | Colour washing two coats over a coat of white wash over new surface with approved quality of lime in approved shade including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhamma rubbing scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I. |
| 19 | Supplying fitting and fixing 20 gauge G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6 mm including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in PCC (1:2:4) blocks of required size applying a priming red lead paint over steel work,all taxes complete as per drawing specification and direction of E/I |
| 20 | Supplying fitting and fixing M.S. grill made of 20x6mm M.S. flats / square bar as per approved design and drawing properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site , hoisting as per building specification and direction of E/I |
| 21 | Providing primer one coats of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 22 | Providing two coats of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 23 | Providing 1.5mm cement punning including curing, carriage ofwater with all leads and lifts as per building specification and direction of E/I. |
| 24 | Providing and supplying in standard length High density polyethylene pipe(HDPE PIPE) confirming to IS 4984-4984/14151/12786/13488,(latest revision with necessary jointing materials like mechanical connector i.e. thread /insert joint/quick release coupler joint/compression fitting joint or flange joint excluding coupler/specials including transportation and freight charge, inspection charges, loading unloading charges, convenience to site, stacking etc all complete excluding GST HDPE pipe of material grade PE 80 - PN0675 mm dia as per specification and direction of E/I |
| 25 | L/C for laying, fitting and fixing of 75 mm dia HDPE pip |
| 26 | Supplying C.I. foot valve having single leather flap and gunmetal seating. Valve shall be fixed on suction side of pumps per requirement including material and hardware. |
| 27 | Supplying outlet flange with firm base of standard make as per specification and direction of E/I |
| 28 | SupplyingG.I fittings (confirming to I.S. -1879 ISI Marked) Tee of 80 mm dia |
| 29 | SupplyingG.I fittings (confirming to I.S. -1879 ISI Marked) Bend of 80 mm dia |
| 30 | SupplyingG.I fittings (confirming to I.S. -1879 ISI Marked) Elbow of 80 mm dia |
| 31 | Supplying Ball valve with firm base of standard make as per specification and direction of E/I.80 mm dia |
| 32 | Supplying solvent cement |
| 33 | Filling in foundation trenches and plinth in layer not exceeding 150 mm.thick well watered,rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5M all complete as per building specification and direction of E/I.(Mode of measurement compacted volume) |
| 34 | ProvidingTor steel Reinforcementof 8mm , 10mm, 12mm & 16mm dia. bars as per approved designand drawing with cutting, cutting, bendingandbinding with annealedwirewithcostofwire, removal of rust, placingtherods in position(excluding carriage of bars to work site) all complete as perbuilding specification and direction of E/I.8 mm |
| 35 | ProvidingTor steel Reinforcementof 8mm , 10mm, 12mm & 16mm dia. bars as per approved designand drawing with cutting, cutting, bendingandbinding with annealedwirewithcostofwire, removal of rust, placingtherods in position(excluding carriage of bars to work site) all complete as perbuilding specification and direction of E/I.10 & 12 mm |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landing, balconies and access platform |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 39 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, piers, abutments, posts and struts |
| 40 | Carriage of materialCement and Steel |
| 41 | Sand |
| 42 | Chips |
| 43 | Bricks |
| 44 | 12.5 HP KIRLOSKAR SOLAR SURFACE PUMP SET ((Pump +Motor KDI-1348+), (Controller Jalverter - J3.7 IP 54),(Solar module above 300 wp) +structure+Plumbing Auxiliary Items+Installation+Transportation ) |
| 45 | Goods & Service Tax (G.S.T.) - |
| 46 | Labour Cess - |