}

Tender For Providing And Fixing Of Bollard Light Along With Its Allied Accessories For Beautification Of Center Park, G Block Vikaspuri In Ward No. 103 Under West Zone., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Providing And Fixing Of Bollard Light Along With Its Allied Accessories For Beautification Of Center Park, G Block Vikaspuri In Ward No. 103 Under West Zone.. Submission Date for this Tender is 18-12-2023. LED Light Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41031050
Tender For Providing And Fixing Of Bollard Light Along With Its Allied Accessories For Beautification Of Center Park, G Block Vikaspuri In Ward No. 103 Under West Zone.
Open Tender
Indian
Delhi
Delhi
18-12-2023

Tender Details

Providing And Fixing Of Bollard Light Along With Its Allied Accessories For Beautification Of Center Park, G Block Vikaspuri In Ward No. 103 Under West Zone.

Key Value

Document Fees
INR 590 /-
EMD
INR 28097.0 /-
Tender Value
INR 1.39 Lakhs /-

BOQ Items

Work Name:Providing and fixing of Bollard light along with its allied accessories for beautification of centre park, G-Block Vikaspuri in Ward No.-103 Under West Zone.-Providing and fixing of Bollard light along with its allied accessories for beautification of centre park, G-Block Vikaspuri in Ward No.-103 Under West Zone.
Sl. No. Item Description
1Part A
2OD16017/2023-2024:DSR-2022 14.16.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
3OD16019/2023-2024:DSR-2022 7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sq. mm
4OD16020/2023-2024:DSR-2022 7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
5OD16021/2023-2024:DSR-2022 5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
6OD16023/2023-2024:DSR-2018 12.13Supplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
7OD16024/2023-2024:DSR-2022 12.37Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
8OD16025/2023-2024:DSR-2022 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
9OD16026/2023-2024:DSR-2022 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
10Part B (Approved Rates)
11122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
12122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
13122.1.48: Supply of following size of PVC insulated & PVCsheathed copper conductor 3 core submersible cable conforming to IS . 694/210 etc. as rqd. 3×2.5 sqmm with voltage grade 1100 volts.
14122.2.1:P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 300x200x105mm (NS) and outer dimension of 333X233X150 mm high dome complete with suitable arrangement for fixing of 4 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd.
15122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminariessymmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panelhousing suitable RCC (1:2:4) shallowfoundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
16122.2.25:Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
17122.2.139:Supplying and laying of following size of C PVC pipe in along with all accessories like socket, bend, couplers etc. conforming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc. direct in ground ( 50 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 25 mm dia
18122.2.140:Fabrication, supplying, installation, testing and commissioning of Bollard light having length 750mm of MS Sheet i/c making design by Laser cutting , as approved by engineer In charge and welding the same, with 2 nos. 10 watt warm white 2 feet long LED tube light fitting and having suitable arrangement to accommodate 2 nos. 10 watt warm white 2 feet long LED tube light , duly painted with one coat of primer and two coat PU paint i/c J-type foundation nut bolt but excluding foundation complete etc. as required.
19Part C
204.4.1:Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail