Tender For Providing And Installation Of Street Light Cs Plant To Smp Shop And Viewers Gallery Of Tsu Bsf Tekanpur, tekanpur-Madhya Pradesh

Border Security Force-BSF has published Tender For Providing And Installation Of Street Light Cs Plant To Smp Shop And Viewers Gallery Of Tsu Bsf Tekanpur. Submission Date for this Tender is 19-12-2023. Street Lighting Tenders in tekanpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41029817
Tender For Providing And Installation Of Street Light Cs Plant To Smp Shop And Viewers Gallery Of Tsu Bsf Tekanpur
Open Tender
Indian
Madhya Pradesh
tekanpur
19-12-2023

Tender Details

Tender For Providing And Installation Of Street Light Cs Plant To Smp Shop And Viewers Gallery Of Tsu Bsf Tekanpur

Key Value

Document Fees
Refer document
EMD
INR 40727.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Providing and Installation of street light CS Plant to SMP Shop and Viewers gallery of TSU BSF Tekanpur
Sl. No. Item Description
1Supply and erection of GI Octagonalof 7 meter length ,top across flat of 70 mm ,bottom across flat of 130 mm with 3 mm thickness ,sq. Base plate size 200 mm with 16 mm thicknesson the existingcement concrete foundationwith the help of 4 nosnut and anchor bolts (size of M20 with 600 mm length) of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. including all accessories (63 A 4 way stud connector, din bar, neutral link etc.) providing and fixing of 2 nos GI spike(1830x20 mm) with 6 SWG GI wirefrom pole to earth directly in the ground for earthingand transportation from factory to work site etc. as required. Fixing of hot dipped galvanized Overhang brackethaving suitable size with sleeve as a cap of suitable diameter fitted with pinching bolted sizeover the existing poles having the provision of fitting 1 nos led luminaire etc. as required. Also supplying and drawing of 1.5 sq. mm 3 core PVC insulated and FR PVC Round Sheathed, Copper Conductor(flexible) industrial cable, 1100 Volt, conforming to IS 694, from din bar toMCB ( flash door) to LED light.The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning.(make bajaj, jindal, tata, C&G) Octagonal GI Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanized internally & externally in accordance with IS 2629.
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
5Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
7Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
8Supplying and embedding following dia HDPE pipe (best quality) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia
9Supplying of PVC insulated and FR PVC Round Sheathed, Nominal Area of Conductor 4.00sq. mm 4 core,Copper Conductor (flexible) industrial cable, 1100 Volt,conforming to IS 694 make Havells/Polycab/KEI/Finolex/RR cables
10Supplying of 3½ X 185 sq. mmCross linked polyethylene and XLPE insulated PVC outer sheathed armoured cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 make Havells/Polycab/KEI/Finolex/RR cables
11Supplying and laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 40 mm dia
12Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. i) Up to 35 sq. mm
13Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required. i) 3½ X 185 sq. mm(57mm)
14Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) single pole
15Supplying and fixing 25 A rating, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of four poles in the existing panel nut bolt din rail, complete with connections, testing and commissioning etc. as required. Make L &T/ ABB/Simence/Schneider
16Providing , installation and testing road lighting luminaries with high power 60W LEDStreet light, operating voltage 140-270 Volt on single phase AC, 50 Hz supply suitable for all weather conditions with excellent thermal management,made up of pressure die cast housing with toughened glass and high power LED"s with secondary optics and IP66 protection. Efficacy = 110/125/135LPW, 10KV SPD Included, Better optics for uniform distribution , heigher soacing between poles and maintenance free system, ideal for road width upto 8 mtrsin existingGI pipe breaket of street ligh pole, nut bolt clamp etc as required, make Crompton model RAPTOR PRO-I Cat No-CRP-409-60-57-SL-GL-NSG or Phillips/ C&S / Helonix/Havells Cat No. ENDURAOMNIPLUSSL60WLED757SASYTOPC
17Design, fabrication, Supplying, installation, testing and commissioning of cubical type compartmentalized outdoor double door LT feeder pillar suitable for 415V, 3Phase, 4 wire 50Hz AC supply system. Panel should be factory fabricated in an approved factoryhaving modern fabrication and testing process . It shall have seven tank pretreatment process comprising of degreasing, rinsing ,de-rusting ,rinsing, phosphatizing ,rinsing and passivation followed by powder coat painting(shade: Siemens Grey RAL 7032) having a paint thickness of 60 microns . panel should be provided with suitable gasket to make it dust/vermin proof.Panel should be IP 54 protected .The Size of panel not less than 0.25 Cum, front surface area not less than 0.63 sq. mtr made with 2 mm CRCA sheet and having detachable 3 mm thick CRCA gland plate, with 200 Amp capacity TPN aluminum bus bar base of insulated brackets or studs as per norms. The panel should be suitable to accommodate 04 nos MCCB of various rating, LED indicators etc. as reqd,Suitable backlite sheet arrangement for insulation of MCCB and other switch gears and locking arrangement, hinges of the doors should be as required.The panel should be openable from two sides back & front sides should be fixed with hinges and lock as reqd, and having 300 mm height with 2 mm sheet on the base frame in all sides fixed on outer existing base frame with nut bolts. Inter link arrangement with suitable size bus bar should also be arranged accordingly to MCCB and other switch gears in all respect. (panel shall be made from CPRI approved manufacturers) The drawings will be final as per direction of Engineer-in-charge. the panel should be mounted on 50 mm x 50 mm x 6 mm GI Angle frame having length 0f 1200 mm (600 mm above ground level and 600 mm for foundation). Providing and laying in position cement concrete 1:3:6 (1 cement: 2 coarse sand: 6 graded stone aggregate 20 mm nominal size) in foundation of feeder pillar including form work etc. as required.(panel dimensions 1.00 M x0.6 M x0.4 Mtr) 50 mm for canopy etc. as required. Including following switch gears For incoming 200 A TP MCCB,35/36 KA – 1 Nos, for outgoing- 63 A TP MCCB ,35/36 KA – 2 nos40 A 4 pole MCB etc. as required .(MCCB specifications Ics = 100% Icu as per IEC 60497-II,class II front faces, suitable for isolation ,adjustable overloading setting Ir=(0.8 to 1.0)x In . Make L&T/ABB/Simence
18Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
19Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipefrom earth electrode including connection with GI thimble excavation and re-filling as required.
20Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
21Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required,(Excavation the existing faulty cable, removing the cable the trench for indentifying the faults and relaying the repaired cable in the trench) but excluding sand cushioning and protective covering. Above 95 Sq mm and upto 185 Sq mm.
22Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm
23Making hole below the existing road for passing the undergroung LT cable and UPVC pipe for electric power supply with help of hole making equipments and skilled labour and helper etc. as required.
24Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. i)50 mm dia
25Dismantaling of the existing old defective street light/security light pole alongwith Compact flurescent tube light ,70W/150W/250W HPSV fittings from the existing poles andhanding over to the storeman of HQ etc as reqd
26Providing and installation 10 watt LED bollard, New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source. Also suitable size CC foundation, connectin testing etc. as required. Make Crompton cat No. LBLA1-10-CDL/ Havells/ Phillips