Tender For Repair/Maint Of Elect/Diesel Driven Fire Hydrant Pump, Borewell, Pipe Lines/ Cleaning Of Swt, Swimming Pool/ Under Water Led/ Filter Media And Connected Items At Af Station Bhisiana
Tender Overview
Project Description
Repair/Maint Of Elect/Diesel Driven Fire Hydrant Pump, Borewell, Pipe Lines/ Cleaning Of Swt, Swimming Pool/ Under Water Led/ Filter Media And Connected Items At Af Station Bhisiana As Per Boq/ Price Schedule
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Dec-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-Jan-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | ELECTRIC/ DIESEL FIRE HYDRANT PUMP (SI NO 90) |
| 2 | S&F in replacement ofsingle channel four pipe Laser Aspiration detection unit . The unit should be UL and VDS approved complete with display of all alarm dual filter on board 20000 event log memory worth RS 232 port . The device should support minimum 100 m pipe for each channel and sensivity of 01%m complete all as specified and directed by Engineer in Charge.Note: The Contractor shall be responsibleto replace all spare parts minor/majorrequired to serviceabe of panel , Nothing extra shall be paid to during contract period, If he fail to rectify with 24 Hrs Recovery @ 1000 per day wiil be made in RAR/final Bill . |
| 3 | S&F in replacement of repeater panelhaving display system of existing make and model suitable to incorporate in existing systemhaving LOOP:Fire Red Lamp ON, Open Amber Lamp ON, Short Amber Lamp ON, Isolate Amber Lamp ON Monitor Mains ON 230VDC, Earth Line fault, BAT, low , BAT Discharge, CPU RUN-Processor working Controls: Lamp Test-Healthiness of lamp, Silence -tomute sounders Evacuate-evacuate the building, Re set - To restore system. Contractor shall visit each repeater panel prior quoting the rate to know the current status of respective Panel No claim on whatsoever account shall be entertained during current of work complete all as specified and directed by Engineer in Charge. |
| 4 | Comprehensive maintenance of Microprocessor based panel 1 loop analogue addressble type fire alarmcontrol panel with 80 character CD diaplay with battery backup of 11/2 hours access 500events histrocial logging having loop Free red lamp on , Open Amber lamp ON, Short - Amber lamp On , Isolate - Amber Lamp On,Control : Lamp test-LED Healthy, Sielence - TO stop alarm, Evacuate - fire alarm ON, Reset-to Restore system, Monitor : mains ON-230 VAC, BAT ON-system at BAt, System ON -24 VDC, Xharger ON 27.3 VDC, Fire sounser ON, Silence - MUTE/ACK, Earth - Line Fault , BAT LOW -Bat Below 22 V. (P4)Note The Contractor Shall be responsibleto replace all spare parts minor/majorrequired to serviceabe of panel , Nothing will be paid to extra during contract period, If he fail to rectify within 24 Hrs Recovery @ 1000 per day wiil be made in RAR/final Bill. |
| 5 | S&F in replacement power supply units comprising of battery backup for 11/2 hours charging units , MCB DB and necessary MCB -power supply unit should have capacity to operate on 230 volt AC maininput & provide 24 to 30 volts DC output for powering upTheunit shall also supports battery backup in ase of AC main failure and should have built in charging circuit to batttery.suitable toexisting make and model suitable to incorporate in existing system. Contractor shall visit each supply unit prior quoting the rate to know the current status of respective supply unit mechanism No claim on whatsoever account shall be entertained during current of work complete all as specified and directed by Engineer in Charge. (P 4) |
| 6 | S&F in replacement of analoge addressable photoe electric smoke detector with mounting based LED , address switch to programme the detector from 01-99 with BASEcomplete as required programme the detector rom 01-99with BASE complete as required the contractor shall visit each photo electric smoke detector unit prior quoting the rate to know the current status of respective photo electric smoke detectormechanism No claim on whatsoever account shall be entertained during current of work complete all as specified and directed by Engineer in Charge. |
| 7 | S&F in replacementof addressable hooter with strobe for alaram annunciation along with all required accessories (Weathr proof all as specified and as directed by Engr-in-charge existing make and model suitable to incorporate in existing system.Note(a) The contractor shall check make and model before quoting oftender and inspect hooter unit prior quoting the rate to know the current status of respective hootermechanism.(b) No claim on whatsoever account shall be entertained during current of work complete all as specified and directed by Engineer in Charge. |
| 8 | Taking down U/S & S&F of aspiration system address switch to programme the monitor modules from 01-09 complete as per OEM specification suitao bleexisting make and model suitable to incorporate in existing system. Note(a) The contractor shall check make and model before quoting oftender and inspect monitor modules unit prior quoting the rate to know the current status of respective hootermechanism.(b) No claim on whatsoever account shall be entertained during current of work complete all as specified and directed by Engineer in Charge. |
| 9 | Supply and Laying in replacement of , LT UG XLPE insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 150 sqmm 3.5 core all as specified and directed The cost shall be included suitable size of steel gland , thimbles ,lugs required to jointing of cableall as specified and directed by Engr-in-charge (Frompanel to AHU) |
| 10 | Material & labour for replacement ofLanding valve 63 mm including jointing with rubber insertion 3 mm thick bolts, nuts and washers etc complete all as specified and directed by Engr-in-Charge. (Bravo) |
| 11 | Material & Labour for replacement of RRL hose ISI markedwith both coupling dia 63mm in 15mtr length complete all as specified and directed by Engr-in-Charge. (Alpha & Bravo) |
| 12 | S&F in replacement 19mm dia rubber braided hose of 36 mtr length with gate valve and shut of nozzle with working pressure of 12 bar and minimum flow rate 285 OM fixed in existing Hose reel drum of dia 565mm dia cast manual swinging type as complete. (Alpha & Bravo) |
| 13 | Taking down U/S &S&F in replacement Weather proof cabinet of size 900 x 600x 450mm made out of MS sheet 16 gauge having central opening and 4mm thick glass doors (2 Nos) suitably marked on the outside With Letters \"FIRE HOSE\" cabinet with necessary locking arrangement including all fasterns etc and shutter shall be powder coated with signal red colour,shutter with frame fabricated all as specified and directed.Note: The hose cabinet will be fixed PCC Platform near the Fire Hydrant and cost of PCC flatform and fixing is deemed to be included in quoted cost. |
| 14 | S&F in replacement Female/Male Coupling with Blank Caps/Plugs of 63 mm of working pressure 10.5 Kg/Sqcm ofGun metal/Brasscomplete all as specified and directed by Engineer in charge. (Alpha & Bravo) |
| 15 | S&F in replacement flanged & shore connection of 63 mm outlet of material Gun metal/Stainless Steel with nuts, bolts washer etccomplete all as specified and directed by Engineer in charge. (Alpha & Bravo) |
| 16 | S&F ofin repair glass of fire hydrant boxes of size 60x60 mminclrubber gasket/seal complete all as specifiedand directed by Engr-in-Charge. (Charlie) |
| 17 | S&F in replacement basket type simple stainer of CS/CI body with SS strainer element 40 mesh matching flangeincluding nut & Bolts , gaskets suianle for flow 136 cum /hr at pressure of drop not more than 0.2 kg /cm2 at 50% chocked condition, body hydroest at 16.0 kg /cm 2 for suction for fire fighting of size 150 mm bore, complete all as specified and directed by Engineer in Charge. |
| 18 | M&L for cleaning of strainer all type and any sizeincluding dismantling and cleaning using Fernox DS-3 cleaner chemical or OEM recommendation and refixing of the same complete all as specified and as directed by Engr-in-charge |
| 19 | M&L for painting of fire hydrant stand post end flanged 1.5 mtr height with one end bend to 90 degree suitable for double fire hydrant valvesncluding 1 No CI duck foot bend 80 mm double end flanged and 1 no 80 mm 63mm reducer and 1 no 80 mm dia CI buerfly valve completeafter removing all dust, dirt etc and clean the surface thoroughly with two coats of synthetic enamel paint including writing the complete all as specified and directed. |
| 20 | M&L for descaling and servicing the radiator of Diesel engine 62-73 BHP Cap internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage complete all as specified and directed. |
| 21 | M&L for descaling and servicing the radiator of Diesel engine 43/52 BHP Cap internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage complete all as specified and directed. |
| 22 | Material and labour for Drainthe out lived engine oil, clean the oil tank and filling the new engine oil grade 20W 40 as required, complete all as specified and as directed by Engineer in Charge. |
| 23 | Supply and filling coolent, complete all as specified and as directed by Engineer in Charge. |
| 24 | M&L for Repairing the self Dynamo 12 Volts afterremoving from diesel engine set of any capacity and transporting to an authorised sevice centre complete all as specified and directed. |
| 25 | Taking out old U/S and Supply and fixCI body Sluice valve PN 1.6 conforming to ISof size 150 dia complete with nuts,bolts,rubber gaskets etc including ,ISI marked ,including jointing material such as rubber gasket,bolts,nuts,etc suitable for size 150 mm complete all as specified and as directed by Engr-in-charge |
| 26 | Taking out old U/S and Supply and fixCI body Sluice valve PN 1.6 conforming to ISof size 100 dia complete with nuts,bolts,rubber gaskets etc including, including jointing material such as rubber gasket,bolts,nuts,etc suitable for size 100 mm complete all as specified and as directed by Engr-in-charge |
| 27 | Taking out old U/S and Supply and fixCI body Sluice valve PN 1.6 conforming to ISof size 80 dia complete with nuts,bolts,rubber gaskets etc including, including jointing material such as rubber gasket,bolts,nuts,etc suitable for size 80 mm complete all as specified and as directed by Engr-in-charge |
| 28 | Taking out old U/S and Supply and fixCI body Sluice valve PN 1.6 conforming to ISof size 50 dia complete with nuts,bolts,rubber gaskets etc including, including jointing material such as rubber gasket,bolts,nuts,etc suitable for size 50 mm complete all as specified and as directed by Engr-in-charge |
| 29 | Taking out old U/S and Supply and fixCI body NRV valveconforming to ISof size 150 dia complete with nuts,bolts,rubber gaskets etc including, including jointing material such as rubber gasket,bolts,nuts,etc suitable for size complete all as specified and as directed by Engr-in-charge |
| 30 | Taking out old U/S and Supply and fixCI body NRV valveconforming to ISof size 100 dia complete with nuts,bolts,rubber gaskets etc including ,including jointing material such as rubber gasket,bolts,nuts,etc suitable for size complete all as specified and as directed by Engr-in-charge |
| 31 | Taking out old U/S and Supply and fixCI body NRV valveconforming to ISof size 50 dia complete with nuts,bolts,rubber gaskets etc including ,including jointing material such as rubber gasket,bolts,nuts,etc suitable for size complete all as specified and as directed by Engr-in-charge |
| 32 | Taking out U/S battery cell 7 Supply and fix New battery cell12 V 7AH , Charging voltage ; Stand by 13.5 V Cyclic : 14.7 V 0f make Amaron/Exide/ Luminoous, complete all as specified and as directed by Engr-in-charge |
| 33 | S&F in replacement of GI pipe and fix MS ERW pipe nominal dia 100 mm as per IS 3589 (1981) thickness 5.0 mm, including specialjoints complete for deliveryandside including necessarynutsbolts and rubber etc, complete with one coat of red oxide and two coat of black paint on ms pipe complete all as specified and as directed by Engr-in-charge. NoteThe cost shall be inclusive for making suction/delivery pipe from existing pipe from pump to SWT pipe line for delivery includingwelding , bending work .,socket, union , bend etc, bend |
| 34 | S&F in replacement of GI pip and fix MS ERW pipe nominal dia 80 mm as per IS 3589 (1981) thickness 5.0 mm, including specialjoints complete for deliveryandside including necessarynutsbolts and rubber etc, complete with one coat of red oxide and two coat of black paint on ms pipe all as specified and as directed.Note: -The cost shall be inclusive for making suction pipe from existing pump to SWT for connection of varios sizes of DI/GI pipe line for delivery includingwelding , bending work . |
| 35 | Taking down U/S &Supply and fixCI body foot valve ISI marked of size 150 dia complete with nuts,bolts,rubber gasketsjointing material suitable for size 150 mm complete all as specified and as directed by Engr-in-charge |
| 36 | Taking down U/S &Supply and fixCI body foot valve ISI marked of size 80 dia complete with nuts,bolts,rubber gasketsjointing material suitable for size 80 mm complete all as specified and as directed by Engr-in-charge |
| 37 | Taking down U/S &Supply and fixCI body foot valve ISI marked of size 100 dia complete with nuts,bolts,rubber gasketsjointing material suitable for size 80 mm complete all as specified and as directed by Eng-in-Charge |
| 38 | S&F in replacement of CI spun pipe Centrifugally Cast Iron \"LA\"150mm dia spigot and socketed ends suitable for lead joints in trenches complete all as specified and directed. |
| 39 | S&F in replacemnt of CI spun pipe Centrifugally Cast Iron \"LA\" 100mm dia spigot and socketed ends suitable for lead joints in trenches complete all as specified and directed. |
| 40 | M&L for run lead joints for 150mm dia spigot and socketed CI pipe fittings including spun yarn etc. complete all as specified and as directed by Engr-in-charge |
| 41 | M&L for run lead joints for 100mm dia spigot and socketed CI pipe fittings including spun yarn etc complete all as specified and as directed by Engr-in-charge |
| 42 | M&L for run lead joints for 80mm dia spigot and socketed CI pipe fittings including spun yarn etc. complete all as specified and as directed by Engr-in-charge |
| 43 | Dismantling the Electric Induction Motor / submersible motor AC, 3 Phase, 415 Voltsfrom the foundation/ Blast pen SWT of depth of 5-10 mtr of capacity 5HPby disconnection of Cable and coupling connection of Pump and shifting to the Civil Workshop for the following repir/ replacement work complete all as specified and directed by Engr-in-Charge:-(a)Re-winding the motor with supper enameld copper winding wire having suitable size copper wire with proper insulation including varnishing, heating complete.capacity of 7.5 HP(b)Replacement of ball bearing NBC or as per exsting make/ model with providing of high grade grease.(c) Re- assembling the complete motor and shifting to the same to its existing location and re-connection all cable and coupling and testing the same on load all as directed by Engr-in-Charge. (BP-6-10) |
| 44 | All as per item No. 1.042 above but having 10 HP capacity submersible motor complete all as directed by Engineer in Charge. |
| 45 | All as per item No. 1.042 above but having 20 HP capacity motorcomplete all as directed by Engineer in Charge. |
| 46 | All as per item No. 1.042above but having 40 HP capacity motorcomplete all as directed by Engineer in Charge. |
| 47 | S&F in replacement ofCI fittings bend (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket) etc Tee pieces single branch \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of size upto 150mm complete all as specified and directed. |
| 48 | S&F in replacement of Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 50 mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge. |
| 49 | All as per item No. 1.047 above but having size 40 mm dia bore complete all as specifed and directed by Engr-in-Charge. |
| 50 | All as per item No. 1.047 above but having size 25 mm dia bore complete all as specifed and directed by Engr-in-Charge. |
| 51 | S&F in replacement ofRubber coupling TC-16/TC-14 suitable for 40 HP Centrifugal pump complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F in replacement of new star delta starter with auxilary contracts for remote autoauto, starting, 4 Pole ContactorType TC1-Dx , overload relay Type LR3D/LR1D, auto start switch, 3 position slector switch for SPP auto /SPP / Manual on / off rocket switch , Voltmeterwith selector switch , auppressed scale ammeter , motor ON/Off Trip indicator starting suitable for operating fire pump up to 20 HP jockeyfire pump Note The starter suitable to incorporate in existing enclosure , and contractor shall visit the site before quoting of tender. The contractor shall bound to bring star delta starter as existing model , if he fail to arrange to provide the same model he will arrange a seprate enclosure near Existing panel and amking all electricla and contral wiring arrange free of costModel No BE3SPSSDX254322RS or existing make and model complete all as specifed and directed by Engr-in-Charge. |
| 53 | S&F in replacement of new star delta starter with auxilary contracts for remote autoauto, starting, 4 Pole ContactorType TC1-Dx , overload relay Type LR3D/LR1D, auto start switch, 3 position slector switch for SPP auto /SPP / Manual on / off rocket switch , Voltmeterwith selector switch , auppressed scale ammeter , motor ON/Off Trip indicator starting suitable for operating fire pump up to 40 HP AMP RANGE40-57 forfire pumpNote The starter suitable to incorporate in existing enclosure , and contractor shall visit the site before quoting of tender. The contractor shall bound to bring star delta starter as existing model , if he fail to arrange to provide the same model he will arrange a seperate enclosure near existing panel and amking all electricals and control wiring arrange free of costModel No C&S BE3SPSSD6335NW359 or existing make and modelcomplete all as specifed and directed by Engr-in-Charge. |
| 54 | S&F in replacement Contactor 160A , 415 VAC, 50 Hz complete as per existing Make HPL complete all as specifed and directed by Engr-in-Charge. |
| 55 | S&F in replacement Thermal over load relay 9- 32 A, 415 V, 50 Hz as per existing Make & Type complete all as specifed and directed by Engr-in-Charge. |
| 56 | S&F in replacement of Electronic timer Star-Delta of 3S-120 Second as complete all as specifed and directed by Engr-in-Charge. |
| 57 | S&F in repairs MCCBs 400 Amps, 4 Pole having rupturing capacity 36KA, 415 volts including termination point for connection complete all as specified and directed. |
| 58 | S&F in repairs MCCBs 250 Amps, 4 Pole having rupturing capacity 25KA, 415 Volts including termination point for connection complete all as specifed and directed by Engr-in-Charge. |
| 59 | S&F in repairs MCCBs 100 Amps, 4 Pole having rupturing capacity 16KA, 415 volts including termination point for connection complete all as specifed and directed by Engr-in-Charge. |
| 60 | S&F in repairs MCCBs 63 Amps, 4 Pole having rupturing capacity 16KA, 415 volts including termination point for connectioncomplete all as specifed and directed by Engr-in-Charge. |
| 61 | Dismantling/taking down the centrifugal pump set of capacity 40 HPfrom foundation after disconnecting of discharge, suction and induction motor connection and shifting to the same to Civil Workshop at Bathindafor the following repair :-(a) Dismantling the complete pump and taken out main shaft and impeller from the pump by disconnection of all nuts, bolts and washers and minor repair and balancing of main shaft and impeller by necessary lathe and machine work and replacement with complete new gasket and mild steel nut, bolt , check nut and washer complete all as directed.(b) Replacement of ball bearing NBC 6312 including providing of required grease complte 02 Nos.(c) Re-assembling the complete and fixing at site and connection of suction, discharge and the induction motor and testing the same on full load complete all as specifed and directed by Engr-in-Charge. |
| 62 | All as above but 20 HP capacity of pump complete all as specifed and directed by Engr-in-Charge. |
| 63 | All as above but 10/7.5 HP capacity of pump complete all as specifed and directed by Engr-in-Charge. |
| 64 | M&L for replacement of Pump motor coupling fully suitable for 40 HP pump with rubber bushes. |
| 65 | M&L for replacement of Pump motor coupling fully suitable for 20/10 HP pump with rubber bushes. |
| 66 | M&L for replacement of UNSV rubber insertion packing suitable for 200mm CI foot valve/suction pipe flanged incl replacement of UNSV nut and bolts. |
| 67 | M&L for prepration of old painted surface of Fire Hose Cabinet of any sizeby scratching /rubbing down the old paint by wire brush or emery paper and applying two coat of Red oxide Paint (weather proof and rust resistant) etc. complete all as specifed and directed by Engr-in-Charge. |
| 68 | M&L for prepration of old painted surface of 40 HP Centrifugal Pump and motorby scratching /rubbing down the old paint by wire brush or emery paper and applying two coat of synthetic enamelecd paint etc. complete all as specified and directed. |
| 69 | M&L for prepration of old painted surface of 10 to 20 HP Centrifugal Pump and motorby scratching /rubbing down the old paint by wire brush or emery paper and applying two coat of synthetic enamelecd paint etc. complete all as specifed and directed by Engr-in-Charge. |
| 70 | Repair/overhauling ofDiesel Driven Pump of Capacity 52 BHP installated at Bomb Dump.(a) Dismantling and removing nuts & bolts Electric connections, water connections for the repairs.(b) Dismantling/opening of complete cylindr head assembly rocker arms assembly piston head assembly sleeves by removing nuts & bolts for repairs complete.(c) Servicing Washing of complete engine parts with kerosene oil.(d) Reassembling of complete engine by tightening of nuts and bolts with replacement of the following engine part and testing on full load for 8 hours :-(i)Piston complete.(ii) Sleeve.(iii) Valve Seat.(iv) Guide Valve.(v) Injector.(vi) Gasket Set.(vii) Pump repair complete.(viii) Fuel Filter.(ix) Lubrication oil filter.(x) Air Filter.(xi) Ring Set.(xii) Conneting Rod Bearing.(xiii) Cylinder Head.(xiv) Calibration of Pump.(xv) Head repair.(xvi) CR Brush.(xvii) Main Bearing.(xviii) Timing Seal.(xix) Complete Packing Kit(xx) Water Ring Kit(xxi)Radiator Cleaning.(xxii) Nozzle Pump Set.(Alpha & Bravo) |
| 71 | M&L for servicing of Diesel Engine of 52/60 BHP with replacement of fuel filter any size as per existing - 1 Set, Air filter - Each, Oil/Lubricant Filter - Each, Engine Oil- 10 Ltr, Coolant up to max level, hose pipe as per existing - Set of two, Battery Terminal - Set of Two, Fuel Pipe fuel Tank to Fuel Filter with Clamp-Each and Radiator cleaning complete all as specifed and directed by Engr-in-Charge. |
| 72 | M&L for Repairing the self starter afterremoving from the Diesel Engine set of capacity 52/60 BHP and transporting to an authorised sevice centre complete all as specified and directed. |
| 73 | M&L for repairs to gate and replacement of spindle suitable for 150mm sluice valve complete all as specified and directed by Engr-in-Charge. |
| 74 | S&F in replacement ofGland Dori suitable for pump set any capacity complete all as specifed and directed by Engr-in-Charge. |
| 75 | S&F in replacement of High Grade Grease for Pump Set and Motor complete all as specifed and directed by Engr-in-Charge. |
| 76 | S&F in replacement of NRVTikki suitable for 150/100 mm bore NRV complete all as specifed and directed by Engr-in-Charge. |
| 77 | M&L for attending complaint day to day like , tightning of nut bolot,finding of leakge in pump any type , cheking ofstarting of diesel driven pump , checking of battery thimbles,priming work using seprate submersible pump or tanker mounted vehicle for filling of suction/ delivery pipe with water and checking of serviceablity of pumpand opening ofvalve /NRV with nut bolt finding of leakage in sluice/gate valve/ NRVremoving of air release from pump and operating of pump and checking pump is lifting of water with force or not if not then priming of pump with water and find the fault and rectify the fault of pump , ifnot lifting of water then replace galnd rope and water seal given in schedule, if battery is found discharge the contractor remove battery from mechanical hydrant pump and transport to workshop for charginf purpose and after fullcharge of battery the contractor again transport from work shop to pump and install in pump house and start the engine up to satisfaction of Engr-in-charge . The motor of mechanial hydrant pump/ Electrical operated pump any capacity installed at Bravo / Alpha, Charlie P-IV fire hydrant pump house stopping leakege of GI Pipe upto 150 mm dia by replacing any type of (bend, tee, elbow, reducer, end plug, taper, union, nipple, socket etc) all as specified and directed by Engr-in-Charge |
| 78 | Taking out unservicable iron made nozzle and Supply and fix brass nozzleof size 1/4 \" dia suitable for fountain. the cost shall be deemed to fixing of nozzle with suitable size of socket nozzole welded in existing pipe in foutain complete all as specified and directed by Engineer in Charge. |
| 79 | Taking out unservicable brass nozzle and Supply and fix brass nozzle of size 20 mm dia \" dia suitable for fountain complete all as specified and directed by Engineer in Charge. |
| 80 | Taking out unserviceable and S&F under water LED lights lumiplus V1 PAR56 16/20Watt and niche. Make : Astral, Haywards, Leisure Pool. (multicolour) water proof luminarieswithof high out put of LEDs housed in complete enclosure of stainless steel body toughened glass with elastomer seal special plastic cable gland compact socket head fastners and mountingbracket are all of stainless steelprovided for aiming the object all as specified and directed. |
| 81 | Taking out U/s & Supply and fixLEDlight15 /20 watts and RGB (multicolour with remote ) water proof luminaries ip 65 protection withof high out put of LEDs housed in complete enclosure of stainless steel body toughened glass with elastomer seal special plastic cable gland compact socket head fastners and mountingbracket are all of stainless steelprovided for aiming the object all as specified and directed. |
| 82 | Taking out unservicable aluminium, cable of size 2.5 andSupply and fix 3 core 2.5 sqmm cable PVC insulated and sheathed sumersible type with stranded copper conductor complete all as specified and directed by Engineer in Charge. |
| 83 | Taking out unservicable aluminium cable of size 1.5 sqmm and Supply flexible cable1.5 sqmm 3core PVC insulated and sheathed submersible type with stranded copper conductor complete all as specified and directed by Engineer in Charge. |
| 84 | Taking out unservicable starter and Supply and fix floor mountedthree phase star delta starter with suitable arrangenment floor mountedcubical type, for outdooruse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of CRCA sheet of 2.15 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangementswith ,,incoporating Heavy dutyTC1-DX overload relay type LR3D,/LR1D Auto start switch , 3 position slector switch for Single phase preventer , auto/SPP manual/Manual (AS4), on/OFF voltmeter with selector switch , suppressed scale ammeter, motor ON &Trip with rigid busbar , Star Delta Starterin sheet steel enclosure suitable forcapacity submersible pump with relay range 14-22 Amps -CAT No BE3spssdx254321x-b of Make C&S/MU-G6(SS97756) L&T Note : The cost of PCC foundation shall be deemed to be included in this item rate. |
| 85 | M&L for cleaning of/SWT at blast pne of size 40 mtr dia and depth of 10 mtrby pumping out the water below foot valve and cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and pumping out soiled watercomplete including writting the capacity and date of cleaning with white paint over black painted surface completein all respect andas specified and directed by Engineer in Charge. (Peroidity ad directed by Engr-in-Charge) |
| 86 | M&L for cleaning of fountain of size 63 mtr dia and depth of 1 mtrby pumping out the water below foot valve and cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and pumping out soiled watercomplete including writting the capacity and date of cleaning with white paint over black painted surfacein all respect andas specified and directed (Peroidity ad directed by Engr-in-Charge |
| 87 | All as above but for cleaning of fountain ofsize ofstepped type 10 mtr X 15mtr X 10mtr mtr, complete all as specified and directed by Engineer in Charge. |
| 88 | All as above but for cleaning of fountain ofstepped type 5 mtr X 10mtr X 10mtr, complete all as specified and directed by Engineer in Charge. |
| 89 | Dismantling monoblock pump set 01 HP to 5 HP 3 phase 415 V from foundation base plate after isolating the electric and earth lead connections, suction and delivery pipes etc opening the pump set, motor rotar and statar etc for repair/overhauling and varnishing and baking the stater winding to enhance the insulation level and reassemblying the pumpset and reinstalling on foundation frame connecting, testing and commissioning complete all as directed by Engineer in Charge. Note :- All spares shall be measured as supply only under seperate items |
| 90 | (a) Pump shaft sleeve made out of gun metal |
| 91 | (b) Key for main shaft/impeller |
| 92 | (c)Check nut |
| 93 | (d)Water seal |
| 94 | (e)Ball bearing complete existing size ISI marked |
| 95 | Dismantling submersible pump set type upto 10 HP 3 phase 415 V from existing location after isolating the electric and earth lead connections, suction and delivery pipes etc opening the pump set, motor rotar and statar etc for repair/overhauling and varnishing and baking the statar winding to enhance the insulation level and reassemblying the pumpset and reinstalling on foundation frame connecting, testing and commissioning complete all as specified.Note :- All spares shall be measured as supply only under seperate items |
| 96 | a) Cast iron impeller |
| 97 | b) Bearing suitable for existing submersible pump |
| 98 | c) bush |
| 99 | d) Water seal |
| 100 | (e)Key for main shaft/impeller |
| 101 | Dismantling submersible pump set type upto 5 HP 3 phase 415 V from existing location after isolating the electric and earth lead connections, suction and delivery pipes etc opening the pump set, motor rotar and statar etc for repair/overhauling and varnishing and baking the statar winding to enhance the insulation level and reassemblying the pumpset and reinstalling on foundation frame connecting, testing and commissioning complete all as specified. |
| 102 | a) Cast iron impeller |
| 103 | b) Bearing suitable for existing submersible pump |
| 104 | c) bush |
| 105 | d) Water seal |
| 106 | M & L for Rewinding of pump motor 415 Volt 3 phase after disconnecting electric cable and eath lead, suction and delivery pipes, shifting to work shop, dismantling the motor assembly and removing the burnt out copper winding of statorrotor and cleaning the stator slotsand rotorand core assembly, rewinding to stator and rotorsuitable gauge super enamelled copper wire with insulating papers and insulation cloths, varnishing the winding and baking heatingfor achieving the required insulation resistance, re-assembling the motor and testing complete, incl transporting back to siteand fixing motor to its original place, reconnecting electric cable and earth leads etc testing and commissioning complete in all respect all as specified and as directed by Engr-in-charge for the up to 7-10 HP capacity |
| 107 | All as above but 10-15 HP |
| 108 | All as above but 40 HP |
| 109 | S&F in repair for wiring with flexible cable0.5 sqmm 3core PVC insulated and sheathed sumersible type with stranded copper conductor (for Light), complete all as specified and directed by Engineer in Charge. |
| 110 | Material and Labour for Disconnecting the existing 150/200/mm DI/CI pipe ,suction and deliveryof any type from the pump set and supply and fixing with newNRV and foot valve of size150/200 mm bore given in schedule and again connecting of the same with leak proof joint of pipe after fixing ofNRV/Foot valve all as specified and directed. Note :- The cost shall be included nut bolt, Rubber packing/gasket, Tee, Flange, Mehanical joint, Collar , nipple, union, weldign work or lead jointetc |
| 111 | Supply & Fixing/Laying of40 mm bores of tubes \"medium grade\" galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 112 | Supply & Fixing/Laying of 25 mm bores of tubes \"medium grade\" galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 113 | Supply & Fixing/Layingt of50 mm bores of tubes \"medium grade\" galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 114 | M & L for Excavation in trenches, not exc 1.5 m wide and not exc. 1.5 m in depthand getting out hard/dense soil all as specified and as directed. |
| 115 | M & L for returning filling in including spreading, levelling, watering and ramming in layers not exceeding 25 cm thick with earth obtained from excavation all as specified and as directed. |
| 116 | M & L for removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and as directed. |
| 117 | M&L Fazilka sand as in sand cushioning to under ground cable including punning down all as directed by Engr-in-Charge |
| 118 | M&L for Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed. |
| 119 | Supply & Fixing/Laying in repairs 100 mm bores of tubes \"medium grade\" galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 120 | Supply & Fixing/Laying of 20 mm bores of tubes \"medium grade\" galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 121 | Supply & Fixing/Laying of 15 mm bores of tubes \"medium grade\" galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 122 | S&FMechanical joint suitablefor 150 mm bore CI pipe ,inluding cutting pipe excavation & earth work etc, nuts, bolts and washers complete all as directedby Engr-in-Charge. |
| 123 | S&FMechanical joint suitablefor 50/40 mm bore CI pipe ,inluding cutting pipe excavation & earth work etc, nuts, bolts and washers complete all as directedby Engr-in-Charge. |
| 124 | Taking up or down U/S GI/PVCtubingand connections of size40/50 mm, complete all as specified and as directed by Engineer in Charge. |
| 125 | Taking up or down U/S GI/PVCtubingand connections of size25 mm, complete all as specified and as directed by Engineer in Charge. |
| 126 | Taking up or down U/S GI/PVCtubingand connections of size20 mm, complete all as specified and as directed by Engineer in Charge. |
| 127 | Taking up or down U/S GI/PVCtubingand connections of size15 mm, complete all as specified and as directed by Engineer in Charge. |
| 128 | SWIMMING POOL/ UNDER WATER LED/ FILTER MEDIA (SI NO 91) |
| 129 | Material and labour for cleaning of swimming pool(size 25mx13.5mx4m)bycleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching power and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water The quoted cost shall be includingacid or other cleaninng chemical required to cleaning of pool bottom and wall tiles or using pressure jet pump or suction pump for lifting of waste water from pool surface to out side of pool complete in all respect allas specified and directed.by Engineer-In-Charge.Note - Quoted rates shall include for filling the swimming pool with water and de-watering as per requirement. The water shall be provided by department for filling Pool. |
| 130 | Material and labour for cleaninglevel tank for swimming pool using acid and bleacing powder for cleaning purpose and other suitable methods before filling as required atsite all asdirected by Engineer-In-Charge. Note - Quoted rates shall include for filling the level tank for pool with water and de-watering as per requirement. The water shall be provided by department for filling Pool. |
| 131 | Testing of potable water sample collected from Air force stn Bhisinaswimming pool and testing report required through Govt/NABL accrediated laboratory as approved by GE as per BIS - 10500-2012. The Following tests shall be carried out as under.(i) Temperature (ii) Turbidity (iii) Colour (iv) Total hardness, Mineral Oil , residual chlorine (v) Calcium(vi) Magnesium(vii) Total Alkalinity (viii) Chloride, Phenolic Compounds (as MBAS) (ix) Total disolved solids (x) Flouride. COD , BOD, E-Coil, bacteria. |
| 132 | Supply and Pouring Non Ferric alum type crystal, white appearance, superior grade after making inliquid form to dosing plant.Note: The quoted unit cost shall deem to be include mixing and dosing on daily basis upto completion of Contract. The qunatity of material shall be decided by AGE E/M.The Make and sample shall be approved by GE. |
| 133 | M&L for opening pump set self priming type 3 phase 415 volt of capacity up to 05 HP,from motor coupling after isolating the electric and earth lead connections opening the pump set for repair/overhauling & proper alignment of shaft etc including replacing the spare parts under appropriate items & reassemblying the pumpsetgreasing connecting, testing and commissioning complete including necessary Lathe works at Swimming Pool complete all as specified and directed by Engineer in Charge. Spare Parts shall be measured and paid under following appropriate items. |
| 134 | Pump shaft sleeve |
| 135 | Key for main shaft/impeller |
| 136 | Check nut for pump set shaft |
| 137 | Mechanical water seal |
| 138 | Impeller |
| 139 | Mechanical seal plate |
| 140 | Pump set bearing housing |
| 141 | Pump Shaft |
| 142 | Ball/ Roller bearing complete |
| 143 | O\" Ring |
| 144 | D\" Ring |
| 145 | Strainer |
| 146 | Taking down electric motor up to 05 KW 415 voltcoupled to pump after disconnecting theelectrical connection, and earth connections from its foundation and transportation to work shop , checking the serviceability of ball bearing both side of motor , greasing of bearing up to free rotation of shaft of motorcomplete, greasing on reassemblying the motor to reinstallation on foundation, reconnecting back the cable and earth connections etc complete in all respect and starting the pump complete all as specified and directed by Engineer in Charge. |
| 147 | Supply and fix ball/roller bearing for motor front and back for shaft complete all as specified and directed by Engineer in Charge. |
| 148 | M&L for Rewinding of pump motor 415 Volt 3 phase of capacity 05 KW motor after disconnecting electric cable and eath lead, suction and delivery pipes, shifting to work shop, dismantling the motor assembly and removing the burnt out copper winding of stator and cleaning the stator slots and core assembly, rewinding to stator and rotor winding with suitable gauge super enamelled copper wire with insulating papers and insulation cloths, varnishing the winding and baking heatingfor achieving the required insulation resistance, re-assembling the motor and testing complete, incl transporting back to siteand fixing motor to its original place, reconnecting electric cable and earth leads etc testing and commissioning complete in all respect all as directed by Engineer in Charge. |
| 149 | M&L for opening Suction Sweeper having discharge of 2 LPS of 20 Mtr. head complete with suction head, brush, flexible hose pipe & maninal pulling rope, suction pipe with inlet valve, nozzles including electrical connections. isolating the electric and earth lead connections opening the suction sweeper set for repair/overhauling & proper alignmentetc including replacing the items with new items given vide item below,reassemblying the suction sweepergreasing connecting, testing and commissioning complete including necessaryworkscomplete all as specified and directed by Engineer in Charge. Spare Parts shall be measured and paid under following appropriate items. |
| 150 | Suction sweeper Bearing |
| 151 | Pump Shaft Sleev,& Oil Seal |
| 152 | (i) Servicing of existing filters and opening of manholes of pressure Sand filters & provide open back wash for dirt removal, Removal of complete media from pressure sand filter and refilling of filter media in filters under appropriate items.(ii) Inspection of internal strainers, closing of main holes, servicing of inlet, outlet, backwash & air release diaphragm valve.(iii) Testing trail run for pressure sand filter.(iv) Testing of water sample through reputed laboratory for inlet & outlet water. Note: The cost of the testing of water will be measured and paid under appropriatein schedule.(v) Supply for cleaning chemical as per OEM recommendation for cleaning of existing sand filters. |
| 153 | M&L forDisconnecting and again reconnectingafter arresting the leakge in tothe existing 200/100/63 MM CPVC/PVCpipe ,suction and deliveryof any type from the pump set/header for deliveryandside including necessarynutsbolts ,reducer/tee/joint/union , welding works and rubber etc, all as directed by Engineer in Charge.Note: The quoted cost shall deemed to be include dismantling of pipe and fusion joint or any other type joint to make pipe serviceable , Tee , Bends , Flange , Nipple , union / adapters and the cost shall also included suitable arrangement of jointing machinne for PVC/CPVC pipe . |
| 154 | Taking out unservicable starter and Supply and fixthree phase Motor starter DOL in sheet steel enclosure suitable for 7.5 HP capacity submersible pump with relay range 13-18 Ampsincorporating heavy duty 4 pole contactor type TC1 -Dx with wide band opening coil overload relay type LR3D with manual re-set and yellow flag for trip indication, complete all as specified and directed by Engineer in Charge. |
| 155 | M&L for Painting of Installed Machineries at Swmming Pool Pump House by scrapping existing paint and spraying one coat of synthetic enamel paintfor follwing items with using Asian/Berger paint manufacturer all as directed.(a) Pump Set :- 05 Nos.(b) Pressure Filter :- 04 Nos.(c) Dosing Pumps :- 02 Nos. including dosing tanks(d) Suction Sweeper :- 01 No. |
| 156 | Taking out unservicablecable of size 1.5 sqmm and Supply & Fixingflexible cable1.5 sqmm 3core PVC insulated and sheathed submersible type with stranded copper conductor (for Light) complete all as specified and directed by Engineer in Charge. |
| 157 | Taking out unserviceable butter fly valve of size 65 mm bore and supply and fix new butter fly valve wafer type in CI Body with integrally moulded liner of nitrile or EPDM stainless steel Disc & stem, Liver operatedas per IS 13095 in PN 1.0 in including jointing material such as rubber gasket,bolts,nuts,etc direct integrallyall as specified and as directed by Eng-in-Charge. |
| 158 | Taking down U/s and Supply and fix LED street light luminaries IP 66 LED135 WattAC supply .The luminaire should have die cast aluminium housing with good thermal management and silicon rubber gasket to ensure IP protection complete all as specified and directed by Engineer in Charge. |
| 159 | Taking down U/s and S&F CPVCSchedule 80 pipes & plainCPVC Schedule 80 fittings of dia 150 mm pipe, The cost shall be included all fitting , adhasive , welding material, jointing material , elbow , adapter, socket , tee, union etc complete all as specified and directed by Engineer in Charge. |
| 160 | Taking down U/s and S&F CPVCSchedule 80 pipes & plainCPVC Schedule 80 fittings of dia 100 mm pipe The cost shall be included all fitting , adhasive , welding material , jointing material , elbow , adapter, socket , tee, union etc |
| 161 | Taking down U/s and S&F CPVCSchedule 80 pipes & plainCPVC Schedule 80 fittings of dia 63 mm pipeThe cost shall be included all fitting , adhasive , welding material , jointing material , elbow , adapter, socket , tee, union etc complete all as specified and directed by Engineer in Charge. |
| 162 | Taking down U/s and Supply , installation , Testing and commissioning of LED flood light100 watt AC supply . The luminaire should be made of pressure die cast aluminiumandicluding driver) complete all as specified and directed by Engineer in Charge. |
| 163 | Taking down U/s and supply and fix CPVC Flange 75 mm dia pipe including all fittings complete all as specified and directed by Engineer in Charge. |
| 164 | Taking out unserviceable and supply and install New valve battery manifold in PVC with flange for connecing to filters as per DIN 2501 standard consists of 05butter fly valve for carrying out filteration , back washing rinsing and shut down of the filters size 300 mm Make Astral, Haywards,Leisure pool.Note The cost shall beincluding jointing material such as rubber gasket,bolts,nuts,etcall as specified and as directed by Eng-in-Charge |
| 165 | S&F Valve battery support brackets consisting 02 support bracket with anti-vortex clamp and fixing screws Make Astral, Haywards,Leisure poolcomplete all as specified and directed by Engineer in Charge. |
| 166 | Supply and make liquid form of copper sulphate (BLUE STONE) CuSO4 andpour in to the swimming pool or dosing tank at swimming poolNote: The quoted unit cost shall deem to be include mixing and dosing on daily basis upto completion of Contract. The quantity of material shall be decided by Engineer in Charge. The Make and sample shall be approved by GE. |
| 167 | Supply onlyfilter media brown sand white quartz sand 16/32\" Mesh size complete all as specified and directed by Engineer in Charge. |
| 168 | Supply onlyfilter media brown sand white quartz sand 1/8\" Mesh size complete all as specified and directed by Engineer in Charge. |
| 169 | Supply onlyfilter media brown sand white quartz sand 1/4\" Mesh size complete all as specified and directed by Engineer in Charge. |
| 170 | Supply onlyfilter media brown sand white quartz sand 1/2\" Mesh size complete all as specified and directed by Engineer in Charge. |
| 171 | Supply only1-1.5\"brown pebbles \"for filter media complete all as specified and directed by Engineer in Charge. |
| 172 | Taking down U/S & S & F 24Watt LED Luminaire with square recess mounted LED flat panel with die -cast aluminium housing finished in premium white powder coatingfittingwith Light complete all as specified and directed by Engineer in Charge. |
| 173 | Taking out unservicable & S & F MCCB 3 pole 100 amps breaking capacity 25 Ka,415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engineer in Charge. |
| 174 | Taking out unservicable & S & F MCCB 3 pole 63 amps breaking capacity 16 Ka,415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engineer in Charge. |
| 175 | M&L Chemical filled bottle withChlorine test kit (ISI Marked) with coloured sample complete with all testing fitments and OT solution in Rexene finished box complete all as specified and directed by Engineer in Charge.Note : Sample avaiable in AGE E/M office. |
| 176 | Supply of OT solution in Rexene finished for testing of chlorine content in swimming pool. Note : Sample avaiable in AGE E/M office |
| 177 | Supply in replacemnet of Swimming Pool Floor Nozzle Inlet Fitting 2 inches Size Heavy Quality Inlet-White. Including all fitting such as , gasket , seal , nut , bolts . The cost shall be included taking down Under water tiles and dismantlingof pool floor PCC for fixing of nozzle and again fixing new tiles if broken tiles during fixing of nozzleand making good and match with disturbed surface complete all as specified and directed by Engineer in Charge. |
| 178 | Supply and fill in to the connected plant after making in liquid form of granual of Trichloroisocyanuric Acid (90%) (C3CI3N303) Chlorine Granuals (90%) Size 5-8 Mesh Appearance : White Granuals of pH : 2.7 to 3.3 efective Chlorine : 90%.Note: The Quoted unit rate shall deemed to be included labour and Material of Chemicals (Make & Sample as approved by GE) |
| 179 | Taking out unservicablepvc pipe and Supply and fix transperent blue plastic vaccum hose50 mm boreincluding hose cufs for connection to suction inlets suitable metal clamps with nut and bolts . Note The rate shall be included for fixing of pipe/ hose nipple /clamp etc in to the suction sweeper. Make : Astral, Haywards, Leisure pool. |
| 180 | Taking out unserviceable and S&F under water LED lights lumiplus V1 PAR 56 LED 16 watt& niche ofMake Astral,Haywards,Leisure pool. |
| 181 | Taking out unserviceable and S&F Transformerwith protection suitable to underwater lightning in swimming pool 300VA from 220 V to 12 V all as directed by Engr-in-charge |
| 182 | S&F 22 Watt LED Luminaire with decorative box typefittingwith blue coloured end caps pre wired for LED tube energy savingwith high efficiency PMMA diffuser gives soft glare free light with available lumen output from 2000 total lumen. The lamp shall be 1200mm length with G13 base.The 20 system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection 2KV ,ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz ,The system efficacy must be between80-100 lumen /watt ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than0.95 , THD < 10% . Indivisual LED\"s should not be visible for glare free output ,colour temperature 6500k all as directed. |
| 183 | Taking down U/s and S&F adapter and flange suitable for PVC/CPVC pipe of nominal dia 160mm, complete all as specified and directed by Engineer in Charge. |
| 184 | S&F Wafer check valve dia 110 mm suitable for pump inlet, complete all as specified and directed by Engineer in Charge. |
| 185 | S&F 0-4 step, one module,modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, complete all as specified and directed by Engineer in Charge. |
| 186 | Cutting of vegetation / grasses earth hips etc, cleaning and leveling of cutting areas in stp area installaions surrounding of pump , filters water storage tanks complete all as specified and directed |
| 187 | S & F Switch modular type, single pole one way 6 Amps, 250 volts Ac suitable for modular switch boxes without indicator, complete all as specified and directed by Engineer in Charge. |
| 188 | M & L for point wiring (concealed) complete with FR PVC insulated sheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic heavy grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes,modular switch plates and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following One light point controlled by one modular switch ,complete all as specified and as directed by EIC. |
| 189 | All as Item No 2.060 but for One fan point controlled by one modular switch |
| 190 | All as Item No 2.060 but for One exhaust fan point controlled by one modular switch. |
| 191 | All as Item No 2.060 but for One switch socket outlet modular type 3 pin 6 amp on same board. |
| 192 | S & F socket modular type single pole one way 6 Amps 2/3 pin 250 volts including taking down the old modular socket complete all as specified and directed by Engineer in Charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender