Tender For Repair Maint Of External Electric Network Incl Lt Lines, Lt Panel Incl Apfc Panel, Mccbs, Earthing, Ug Cables, Perimeter Lights And Connected Works At Manasbal And Sonamarg Under Ge 970, Bandipora-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair Maint Of External Electric Network Incl Lt Lines, Lt Panel Incl Apfc Panel, Mccbs, Earthing, Ug Cables, Perimeter Lights And Connected Works At Manasbal And Sonamarg Under Ge 970. Submission Date for this Tender is 06-01-2024. Electrification Work Tenders in Bandipora Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41028382
Corrigendum : Tender For Repair Maint Of External Electric Network Incl Lt Lines, Lt Panel Incl Apfc Panel, Mccbs, Earthing, Ug Cables, Perimeter Lights And Connected Works At Manasbal And Sonamarg Under Ge 970
Open Tender
Indian
Jammu And Kashmir
Bandipora
06-01-2024

Tender Details

Repair Maintenance Of External Electric Network Incl Lt Lines, Lt Panel Incl Apfc Panel, Mccbs, Earthing, Ug Cables, Perimeter Lights And Connected Works At Manasbal And Sonamarg Under Ge 970

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Dec-2023 No-1 BOQ 30-12-2023
2 30-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 93000.0 /-
Tender Value
INR 46.50 Lakhs /-

BOQ Items

Name of Work:REPAIR MAINT OF EXTERNAL ELECTRIC NETWORK INCL LT LINES, LT PANEL INCL APFC PANEL, MCCBs, EARTHING, UG CABLES, PERIMETER LIGHTS AND CONNECTED WORKS AT MANASBAL AND SONAMARG UNDER GE 970
Sl. No. Item Description
1Excavation in trenches in any type of soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying ofunder ground cable in trenches or cable ducts all complete all as specified.
2Excavation in trenches in any type of soil not exceeding 1.5 Mtr in wide, exceeding 1.5 m depth and not exc. 3.0 m in depth for taking out / laying ofunder ground cable in trenches or cable ducts all complete all as specified.
3Returning, filling in including spreading, levelling, watering andwell ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified
4Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified
5M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified.Note : punned thickness shall be measured for payment purpose
6Supply and laybrick of conventional size 230x115x75mmlocallly available as protection of cable in trenches complete all as specifed and as directed.
7Laying only of serviceable bricks of any size and type recovered during taking out of old cable, over newly laid or re-laid cables complete all as specified and directed.
8M&L for 50mm dia GI pipe light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
9M&L for 80mm dia GI pipe light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
10M&L for 100mm dia GI pipe light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
11S&F in repair of 1.5 sqmm 3 core pvc insulated flexible copper conductor wire from street light terminal box to fittings of required length drawn through and including PVC conduit of suitable size or as indicated and directed.
12Supply and fixing in repair of cable junction box of IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 250 x 2503 x 160 mm incl 01 No MCB SP 6 Amps and hahingbackelite connecting terminals mounted on saddles suitable for 3 phase with neutral system - 04 Nos of suitable length and thickness and connecting the incoming & out going LT cable connections in the terminal block of junction box and fixing clamps made up of GI flat of size 20 x 3 mm of suitable length-02 Sets, incl GI nut and bolt and washers on poles complete all as directed .
13Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 2/3.5/4 core 16 to 70 sqmm in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all asdirected and specified and directed. Note ;- Lugs and Glands will be measured and paid separately.
14All as per Item Sl No 13 above but of size 3.5 core 95 to 240 sqmm
15Taking down or out existing cable of sizes 2/3.5/4 core 16 sqmm to 240 sqmm from the trenches/ducts/along walls/poles through poles / under roads/ inside sub-station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester), stacking and rolling unserviceable cable for further disposal all as directed . Note : Excavation/ cutting of road or floor/ Gl pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule
16Supply and laying under ground LT cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sq mm, 4 core, with aluminium conductor with suitable size aluminium cable lugs and jointed in any description complete all as specified and directed. NOTE:- 1. Excavation , concrete cable protection bicks, pipe, PCC work for crossing/hard standing and sand for cushioning will be measured and paid separately. 2. Cost of aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), gable gland, new nut bolt and washers of required size shall be deemed to be included in theunitrate quoted by the tenderer.
17All as per item Sl No 16 above but of size16 sqmm 2 core
18Description all as per item Sl No 16 above but of size25 sqmm 4 core
19Description allas per item Sl No 16 above but of size35 sqmm 3.5 core
20Description allas per item Sl No 16 above but of size 50 sqmm 3.5 core
21Description allas per item Sl No 16 above but of size 70 sqmm 3.5 core
22Description allas per item Sl No 16 above but of size 95 sqmm 3.5 core
23Description all as per item Sl No 16 above but of size 120 sqmm 3.5 core
24Description allas per item Sl No 16 above but of size 185 sqmm 3.5 core
25Description allas per item Sl No 16 above but of size 240 sqmm 3.5 core
26M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 16sqmm x 4 core cables including testing and commissioining complete all as specified Make : Densons / 3M / Raychem
27All as per item Sl No 26 above but of size 25 to 50 sqmm x 3.5 / 4core, as per the size of existing UG cable. Make : Densons / 3M / Raychem
28All as per item Sl No 26 above but of size 70 to 120 sqmm x 3.5core, as per the size of existing UG cable. Make : Densons / 3M / Raychem
29M&L LT indoor/outdoor end joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty cables with aluminium conductor including jointing kit, including making joints for the cable of size 150/185 sqmm x 3.5 core cables including testing and commissioining complete all as specified ( Make : Densons / 3M / Raychem)
30M&L LT indoor/outdoor end joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty cables with aluminium conductor including jointing kit, including making joints for the cable of size 240-300 sqmm x 3.5 core cables including testing and commissioining complete all as specified ( Make : Densons / 3M / Raychem)
31Supply & fixing in repair 250 A 4 pole MCCB, 36 KA,415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specifeid and directed.
32Supply & fixing in repair 250 A 3 pole MCCB, 36 KA ,415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed.
33Supply & fixing in repair 200 A 3 pole MCCB, 36 KA,415V, 50 Hz, AC supply adjustable type of thermal setting including necessary cable lugs & wire etc complete all as specified and directed
34Supply & fixing in repair 100 A 3 pole MCCB, 16KA ,415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete all complete as specified and directed.
35Supply & fixing in repair 63 A TP MCCB, 16 KA,415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete as specified and directed.
36Supply & fixing in repair digital type Ammeter 96X96 mm square Flush mounted case of class 1.0 complete as specified and directed.
37Supply & fixing in repair digital type Voltmeter 0-500V, 96X96 mm square Flush mounted case of class 1.0 complete as specified and directed.
38Supply & fixing in repair CT 400 - / 5A, 200/5A or 100/5A for ammeter complete as specified and directed.MAKE : AE / IMP/ MECO / MEI / HPL
39M&L in repair for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground(earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanisediron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel,complete all as specified and testing on completion.
40Supply and fixing in repairs decorative garden light (landscape lighting) made up of high grade unbreakable polycarbonate materials of capacity 9W LED complete all as specified and directed. Make : Bajaj Cat Part No BGBOM 650 9W LED (Tulip) or equivalent/Havells/CROMPTON. Note (i) Contractor shallprovide 2 years written manufacturer"s warranty for the LED fixture complete including driver from the certified date of completion. (ii) The contractor should include the rates for PCC as required and nut bolts for fixing the light in the quotated rate.
41Taking out old unserviceable steel tubular/RCC poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle all as specified and directed by Engr-in-Charge.
42M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from groundlevel will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed.
43Supply and fixing in repair off load change over switch in sheet metal enclosure of capacity 4P 63 Amps, complete all as specified and directed.
44Supply and fixing in repair on load change over switch in sheet metal enclosure of capacity 4P 100 Amps, complete all as specified and directed.
45Supply and fixing in repair on load change over switch in sheet metal enclosure of capacity 4P 200 Amps, complete all as specified and directed.
46S & F in repair of Integral LED street light luminaires 60W complete comprising of epoxy powder coated housing, enclosed with glass cover in front having 6000 lumen output mounted on MCPCBin gress protection IP-66 complete all as specified and as directed.
47S & F in repair of Integral LED street light luminaires 90W complete comprising of epoxy powder coated housing, enclosed with glass cover in front having 9000 lumen output mounted on MCPCBin gress protection IP-66 complete all as specified and as directed.
48S & F in repair of LED driver suitable for upto 6000 lumen lumanaries complete all as speified and directed.
49S & F in repair of LED driver suitable for upto 9000 lumen lumanaries complete all as speified and directed.
50M&L for cutting existing road / PCC drain for taking out / laying of underground cable and necessary including earth work and making good to match with the existing surface with PCC 1:2:4 type B1 (using 20mm stone graded aggregates) complete all as specified
51M&L PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation of pole & staycomplete allasspecifiedanddirected.
52M&L PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in fillingof pole & staycomplete allasspecifiedanddirected.
53M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping of polecomplete allasspecifiedanddirected.