Tender For Provision Of Apfc Panels For Water Supply Installation Under Age (I) Mes Lansdowne., lansdowne-Uttarakhand

Military Engineer Services-MES has published Tender For Provision Of Apfc Panels For Water Supply Installation Under Age (I) Mes Lansdowne.. Submission Date for this Tender is 06-01-2024. Power Factor Panel Tenders in lansdowne Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

41027601
Corrigendum : Tender For Provision Of Apfc Panels For Water Supply Installation Under Age (I) Mes Lansdowne.
Open Tender
Indian
Uttarakhand
lansdowne
06-01-2024

Tender Details

Provision Of Apfc Panels For Water Supply Installation Under Age (I) Mes Lansdowne.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 46500.0 /-
Tender Value
INR 23.25 Lakhs /-

BOQ Items

NAME OF WORK: PROVISION OF APFC PANELS FOR WATER SUPPLY INSTALLATION UNDER AGE(I) MES LANSDOWNE.
Sl. No. Item Description
1Supply, installing, testing and commissioning of Automatic power factor improvement capacitor ( APFC )having aggregate capacity : 125 KVAR Outdoor type in 12 stages with micro processor based, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA Sheet having bus bar of aluminium 300 Amps capacity , three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeve with suitable frame work/ support made out of 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete (at IInd Stage P/H and IInd Lift Pump House Installation,Location of IInd Stage pump house is located at hilly terrain and not approachable by road,new LT Panel transportby manually is required which isapprox 1.8 Km). All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:-
2(1)Incoming MCCB 200 Amps 25 KA 4 Pole Adjustable thermal & fixed magnetic setting Ics=100% of Icu - 01 No (2) Microprocessor based Power factor corrector relay 12 stage -01 No. (3) Capacitor duty contactor for 25 KVAR,- 02 Nos (4) Capacitor duty contactor for 20 KVAR,- 01 Nos. (5) Capacitor duty contactor for 15 KVAR, - 01Nos. (6) Capacitor duty contactor for 10 KVAR, - 02 Nos. (7) Capacitor duty contactor for 05 KVAR, - 02 Nos (8) Power contactor 9 A 3 Pole for 03 KVAR, -01 Nos. (9) Power contactor 9 A 3 Pole for 02 KVAR, -01 Nos. (10) Power contactor 9 A 3 Pole for 01 KVAR, -02Nos (11) MCB 63 A,10 KA TP C Curve- 02 Nos. (12) MCB 40 A,10 KA TP C Curve- 01 No. (13) MCB 32 A,10 KA TP C Curve- 01 No. (14) MCB 25 A,10 KA TP C Curve- 02 Nos. (15) MCB 16 A,10 KA TP C Curve- 06 Nos.
3(16) Auto Manul Selector Switch, 6A 1 Pole - 01 No. (17) ON/OFF Push Button, with Elements - 12 Sets (18) Indicating light ON-OFF, 220 V AC -12 Sets. (19) Aux contactor 2 NO + 2 NC, 220 V AC -02 Nos. (20) Power capacitor 25 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 02 Nos. (21) Power capacitor 20 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340, - 01 No. (22) Power capacitor 15 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340, -01 No. (23) Power capacitor 10 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340, - 02 No (24) Power capacitor 5 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340, -02 No. (25) Power capacitor 03 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340, -01 No.
4(26) Power capacitor 02 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340, -01 No. (27) Power capacitor 01 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340, -02 No. (28) Digital Voltmeter 0-500 V 96x96 mm -01 set. (29) Digital Ammeter 0-200 Amps 96x96 mm- 01 set. (30) Volt Meter Selector Switch 6 A , - 01 No. (31) Amps Meter Selector Switch 6 A , - 01 No. (32) C.T. of ratio 200/5 amps 5 VA Class-1.0 -03 Nos (33) Protection MCB 6 Amps SP - 05 Nos. (34) Power Capacitor 3 KVAR heavy duty fixed with bus bar with MCB 10 A TP -1 No (35) Sensing CT 300/5 A or as per site load condition shall be provided alongwith APFC Panel.
5Supply, installing, testing and commissioning of Automatic power factor improvement capacitor ( APFC )having aggregate capacity : 100 KVAR Outdoor type in 12 stages with micro processor based, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA Sheet having bus bar of aluminium 250 Amps capacity , three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeve with suitable frame work/ support made out of 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete (at Zero Stage Pump House Installation,Location of Zero Stage pump house is located at hilly terrain and not approachable by road,new LT Panel transportby manually is required which isapprox 2.5 Km). . All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:-
6(1)Incoming MCCB 160 Amps 25 KA 4 Pole Adjustable thermal & fixed magnetic setting Ics=100% of Icu - 01 No (2) Microprocessor based Power factor corrector relay 12 stage -01 No. (3) Capacitor duty contactor for 25 KVAR - 01 No (4) Capacitor duty contactor for 20 KVAR - 01 No. (5) Capacitor duty contactor for 15 KVAR - 01No. (6) Capacitor duty contactor for 10 KVAR - 02 Nos. (7) Capacitor duty contactor for 05 KVAR - 02 Nos (8) Power contactor 9 A 3 Pole for 03 KVAR -01 No. (9) Power contactor 9 A 3 Pole for 02 KVAR-01 No. (10) Power contactor 9 A 3 Pole for 01 KVAR -02Nos (11) MCB 63 A,10 KA TP C Curve - 01 No. (12) MCB 40 A,10 KA TP C Curve - 01 No. (13) MCB 32 A,10 KA TP C Curve - 01 No. (14) MCB 25 A,10 KA TP C Curve - 02 Nos. (15) MCB 16 A,10 KA TP C Curve - 06 Nos. (16) Auto Manul Selector Switch, 6A 1 Pole - 01 No. (17) ON/OFF Push Button, with Elements - 11 Sets (18) Indicating light ON-OFF, 220 V AC. (19) Aux contactor 2 NO + 2 NC, 220 V AC -02 Nos. (20) Power capacitor 25 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (21) Power capacitor 20 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No.
7(22) Power capacitor 15 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (23) Power capacitor 10 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 02 Nos (24) Power capacitor 5 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 02 Nos. (25) Power capacitor 03 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (26) Power capacitor 02 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (27) Power capacitor 01 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 02 Nos (28) Digital Voltmeter 0-500 V 96x96 mm -01 set. (29) Digital Ammeter 0-200 Amps 96x96 mm - 01 set. (30) Volt Meter Selector Switch 6 A - 01 No. (31) Amps Meter Selector Switch 6 A - 01 No. (32) C.T. of ratio 200/5 amps 5 VA Class-1.0 -03 Nos (33) Protection MCB 6 Amps SP - 05 Nos. (34) Power Capacitor 3 KVAR heavy duty fixed with bus bar with MCB 10 A TP -1 No (35) Sensing CT 200/5 A or as per site load condition shall be provided alongwith APFC Panel.
8Supply, installing, testing and commissioning of Automatic power factor improvement capacitor ( APFC )having aggregate capacity : 50 KVAR Outdoor type in 8 stages with micro processor based, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA Sheet having bus bar of aluminium 150 Amps capacity , three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeve with suitable frame work/ support made out of 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete (at Jharapani Pump House Installation). All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:-
9(1)Incoming MCCB 100 Amps 25 KA 4 Pole Adjustable thermal & fixed magnetic setting Ics=100% of Icu - 01 No (2) Microprocessor based Power factor corrector relay 8 stage -01 No. (3) Capacitor duty contactor for 15 KVAR - 01No. (4) Capacitor duty contactor for 10 KVAR - 02 Nos. (5) Capacitor duty contactor for 05 KVAR - 01 No (6) Power contactor 9 A 3 Pole for 03 KVAR -01 No. (7) Power contactor 9 A 3 Pole for 02 KVAR -01 No. (8) Power contactor 9 A 3 Pole for 01 KVAR -02Nos (9) MCB 32 A,10 KA TP C Curve - 01 No. (10) MCB 25 A,10 KA TP C Curve - 02 Nos. (11) MCB 16 A,10 KA TP C Curve - 05 Nos. (12) Auto Manul Selector Switch, 6A 1 Pole - 01 No. (13) ON/OFF Push Button, with Elements - 8 Sets (14) Indicating light ON-OFF, 220 V AC -8 Sets. (15) Aux contactor 2 NO + 2 NC, 220 V AC -01 No. (16) Power capacitor 15 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No.
10(17) Power capacitor 10 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 -02 Nos (18) Power capacitor 5 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (19) Power capacitor 03 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 -01 No. (20) Power capacitor 02 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (21) Power capacitor 01 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 02 Nos (22) Digital Voltmeter 0-500 V 96x96 mm -01 set. (23) Digital Ammeter 0-100 Amps 96x96 mm- 01 set. (24) Volt Meter Selector Switch 6 A - 01 No. (25) Amps Meter Selector Switch 6 A - 01 No. (26) C.T. of ratio 100/5 amps 5 VA Class-1.0 -03 Nos (27) Protection MCB 6 Amps SP- 05 Nos. (28) Power Capacitor 3 KVAR heavy duty fixed with bus bar with MCB 10 A TP -1 No (29) Sensing CT 150/5 A or as per site load condition shall be provided alongwith APFC Panel.
11Supply, installing, testing and commissioning of Automatic power factor improvement capacitor ( APFC )having aggregate capacity : 40 KVAR Outdoor type in 8 stages with micro processor based, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA Sheet having bus bar of aluminium 150 Amps capacity , three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeve with suitable frame work/ support made out of 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete( at 15 Lakh Gallon Pump House Installation). All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:-
12(1)Incoming MCCB 100 Amps 25 KA 4 Pole Adjustable thermal & fixed magnetic setting Ics=100% of Icu - 01 No (2) Microprocessor based Power factor corrector relay 8 stage -01 No. (3) Capacitor duty contactor for 15 KVAR - 01No. (4) Capacitor duty contactor for 10 KVAR - 01 No. (5) Capacitor duty contactor for 05 KVAR - 01 No (6) Power contactor 9 A 3 Pole for 03 KVAR -01 No. (7) Power contactor 9 A 3 Pole for 02 KVAR -01 No. (8) Power contactor 9 A 3 Pole for 01 KVAR -02Nos (9) MCB 32 A,10 KA TP C Curve - 01 No. (10) MCB 25 A,10 KA TP C Curve - 01 No. (11) MCB 16 A,10 KA TP C Curve - 05 Nos. (12) Auto Manul Selector Switch, 6A 1 Pole- 01 No. (13) ON/OFF Push Button, with Elements - 7 Sets (14) Indicating light ON-OFF, 220 V AC -7 Sets. (15) Aux contactor 2 NO + 2 NC, 220 V AC -01 No. (16) Power capacitor 15 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 -01 No.
13(17) Power capacitor 10 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (18) Power capacitor 5 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (19) Power capacitor 03 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (20) Power capacitor 02 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 01 No. (21) Power capacitor 01 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, confirmed to IS 13340 - 02 Nos. (22) Digital Voltmeter 0-500 V 96x96 mm -01 set. (23) Digital Ammeter 0-100 Amps 96x96 mm - 01 set. (24) Volt Meter Selector Switch 6 A - 01 No. (25) Amps Meter Selector Switch 6 A - 01 No. (26) C.T. of ratio 100/5 amps 5 VA Class-1.0 -03 Nos (27) Protection MCB 6 Amps SP - 05 Nos. (28) Power Capacitor 3 KVAR heavy duty fixed with bus bar with MCB 10 A TP -1 No (29) Sensing CT 100/5 A or as per site load condition shall be provided alongwith APFC Panel.
14Note : for Item Ser No 01 to 04 above The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54(IS/IEC : 61439 (Part-1), 2011& IS/IEC : 61439 (Part-2) 2011) 2. Temprerature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED
15Supplying, laying, jointing and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable (Conforming to IS 7098) ISI marked in trenches/ ducts/ through GI pipes under roads of following size cable complete all as specifed and directed :- Note :- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A.
16Size 240 sqmm 3.5 core.
17Size 185 sqmm 3.5 core
18Size 70 sqmm 3.5 core.
19Size 50 Sqmm 3.5 core.
20Excavation in trenches n.exc 1.5 m width and n.exc 1.5 m in depth for foundation etc or for shafts, well, cess pits, manholes, pier holes etc n.ex 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
21Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed.
22Removing excavated materials to a distance n"exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
23M&Lfor laying river dry and clean sand filling for cushioning in layer 8 cm before laying cable and 15 cm after laying cable in trenches and punned upto 18 cm thick around under ground cable complete all as specified and directed. Note :- Thickness after punning shall be measured for payment.
24Supply and laying cable protection bricks, common burnt clay sub class "B" designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.
25M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earthstrip of size 25x4 mm as earthing lead by means ofbolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009)withconected to eath test point including adequate quantity of charcoal dustand comman salt, PCC (1:3:6) type C-1chamber andfor earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both wayswith MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for wateringand 32mm dia medium earth lead protection pipe completeall as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor.
26S&F galvanized steel water tubing(GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed :- Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc.
2780mm bore
28100mm bore
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail