Tender For Electrical And Candi Items Eandc Of Chp And Ahp, Tuticorin-Tamil Nadu

Bharat Heavy Electricals Limited-BHEL has published Tender For Electrical And Candi Items Eandc Of Chp And Ahp. Submission Date for this Tender is 28-12-2023. Couplers Tenders in Tuticorin Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

41009847
Corrigendum : Tender For Electrical And Candi Items Eandc Of Chp And Ahp
Open Tender
Indian
Tamil Nadu
Tuticorin
28-12-2023

Tender Details

Electrical And Candi Items Eandc Of Chp And Ahp-1 Erection Ht Power Cable Laying- Upto 3Cx120sq.Mm 2 Erection Ht Power Cable Laying-3C Above 120Sq.Mm Upto 630Sq.Mm 3 Supply Supply Of Outdoor Ht End Termination Kit -3C Above 120Sq.Mm Upto 630Sq.Mm 4 Erection Erection Of Outdoor Ht End Termination Kit -3C Above 120Sq.Mm Upto 630Sq.Mm 5 Supply Supply Of Indoor Ht End Termination Kit -3C Above 120Sq.Mm Upto 630Sq.Mm 6 Erection Erection Of Indoor Ht End Termination Kit -3C Above 120Sq.Mm Upto 630Sq.Mm 7 Erection Erection Of Out Door Ht Straight Through Jointing Kit - Upto 3Cx120sq.Mm 8 Supply Supply Of Out Door Ht Straight Through Jointing Kit -3C / 1C Above 120Sq.Mm Upto 630Sq.Mm 9 Erection Erection Of Out Door Ht Straight Through Jointing Kit -3C / 1C Above 120Sq.Mm Upto 630Sq.Mm 10 Erection Lt Power Cable Laying-3C / 3.5C / 4C Upto 35 Sq.Mm 11 Erection Lt Power Cable Laying-3C / 3.5C / 4C Above 35 Sq.Mm Upto 95 Sq.Mm 12 Erection Lt Power Cable Laying-3C / 3.5C / 4C Above 95 Sq.Mm Upto 185 Sq.Mm 13 Erection Lt Power Cable Laying-3C / 3.5C / 4C Above 185 Sq.Mm Upto 400 Sq.Mm 14 Erection Lt Power Cable Laying-2C Upto 35 Sq.Mm 15 Erection Lt Power Cable Laying-2C Above 35 Sq.Mm Upto 95 Sq.Mm 16 Erection Lt Power Cable Laying-2C Above 95 Sq.Mm Upto 185 Sq.Mm 17 Erection Lt Power Cable Laying-2C Above 185 Sq.Mm Upto 400 Sq.Mm 18 Erection Lt Power Cable Laying-1C Upto 35 Sq.Mm 19 Erection Lt Power Cable Laying-1C Above 35 Sq.Mm Upto 95 Sq.Mm 20 Erection Lt Power Cable Laying-1C Above 95 Sq.Mm Upto 185 Sq.Mm 21 Erection Lt Power Cable Laying-1C Above 185 Sq.Mm Upto 400 Sq.Mm 22 Erection Control / Screen Cable Laying Upto 7C / 4P 23 Erection Control / Screen Cable Laying Above 7C / 4P Upto 10C / 6P / 4T 24 Erection Control / Screen Cable Laying Above 10C / 6P / 4T Upto 30C / 20P / 10T 25 Erection Lt Power Cable Glanding& Termination Upto Gland Size Upto 22Mm Including Supply Of Glands, Lugs And Other Consumables 26 Erection Lt Power Cable Glanding& Termination Upto Gland Size Above 22Mm Upto 28Mm Including Supply Of Glands, Lugs And Other Consumables 27 Erection Lt Power Cable Glanding& Termination Upto Gland Size Above 28Mm Upto 35Mm Including Supply Of Glands, Lugs And Other Consumables 28 Erection Lt Power Cable Glanding& Termination Upto Gland Size Above 35Mm Upto 45Mm Including Supply Of Glands, Lugs And Other Consumables 29 Erection Lt Power Cable Glanding& Termination Upto Gland Size Above 45Mm Upto 50Mm Including Supply Of Glands, Lugs And Other Consumables 30 Erection Lt Power Cable Glanding& Termination Upto Gland Size Above 50Mm Upto 62Mm Including Supply Of Glands, Lugs And Other Consumables 31 Erection Lt Power Cable Glanding& Termination Upto Gland Size Above 62Mm Upto 70Mm Including Supply Of Glands, Lugs And Other Consumables 32 Erection Lt Power Cable Glanding& Termination Upto Gland Size Above 70Mm Including Supply Of Glands, Lugs And Other Consumables 33 Erection Lt Power Cable Straight Through Jointing Kit For 3C / 3.5C / 4C Upto 35 Sq.Mm Including Supply Of Staright Through Joiting Kit And Other Consumables 34 Erection Lt Power Cable Straight Through Jointing Kit For 3C / 3.5C / 4C Above 35 Sq.Mm Upto 95 Sq.Mm Including Supply Of Staright Through Joiting Kit And Other Consumables 35 Erection Lt Power Cable Straight Through Jointing Kit For 3C / 3.5C / 4C Above 95 Sq.Mm Upto 185 Sq.Mm Including Supply Of Staright Through Joiting Kit And Other Consumables 36 Erection Lt Power Cable Straight Through Jointing Kit For 3C / 3.5C / 4C Above 185 Sq.Mm Upto 400 Sq.Mm Including Supply Of Staright Through Joiting Kit And Other Consumables 37 Erection Control / Signal Cable Glanding& Termination Upto Gland Size Upto 22Mm Including Supply Of Glands, Lugs And Other Consumables 38 Erection Control / Signal Cable Glanding& Termination Upto Gland Size Above 22Mm Upto 25Mm Including Supply Of Glands, Lugs And Other Consumables 39 Erection Control / Signal Cable Glanding& Termination Upto Gland Size Above 25Mm Upto 32Mm Including Supply Of Glands, Lugs And Other Consumables 40 Erection Control / Signal Cable Glanding& Termination Upto Gland Size Above 32Mm Including Supply Of Glands, Lugs And Other Consumables 41 Erection Control / Signal Cable Straight Through Joint Upto 7C / 4P Cable Including Supply Of Staright Through Jointing Kit And Other Consumables 42 Erection Control / Signal Cable Straight Through Joint Above 7C / 4P Upto 14C / 6P / 4T Including Supply Of Staright Through Jointing Kit And Other Consumables 43 Erection Control / Signal Cable Straight Through Joint Above 14C / 6P / 4T Upto 30C / 20P / 10T Including Supply Of Staright Through Jointing Kit And Other Consumables 44 Erection Communication Cable- Laying Of Profibus / Profibus Pa / Modbus / Ethernet / Fo Cables 45 Erection Communication Cable- Laying Of Profibus / Profibus Pa / Modbus / Ethernet / Fo Cables With Conduit 46 Erection Communication Cable- Glanding& Termination Of Profibus / Profibus Pa Cable Including Supply Of Glands, Lugs / Connectors And Other Consumables 47 Erection Communication Cable-Glanding& Termination Of Modbus Cable Including Supply Of Glands, Lugs / Connectors And Other Consumables 48 Erection Communication Cable- Glanding& Termination Of Ethernet Cable Including Supply Of Glands, Lugs / Connectors And Other Consumables 49 Erection Communication Cable-Glanding& Termination Of Fo Cable ( All The Cores Shall Be Terminated ) Including Supply Of Glands, Lugs / Connectors And Other Consumables 50 Supply Supply Of Cable Clamping Materials ( 25Mm X 3Mm Steel Clamp With Hot Dip Galvanisation ) 51 Erection Erection Of Gi / Frp Type 150 / 100Mm Ladder Tray, Bends And Joints Etc For 2.5 / 3M Length 52 Erection Erection Of Gi / Frp Type 300Mm Ladder Tray, Bends And Joints Etc For 2.5 / 3M Length 53 Erection Erection Of Gi / Frp Type 600Mm Ladder Tray, Bends And Joints Etc For 2.5 / 3M Length 54 Erection Erection Of Gi / Frp Type 50 / 75 / 100Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 55 Erection Erection Of Gi / Frp Type 150Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 56 Erection Erection Of Gi / Frp Type 300Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 57 Erection Erection Of Gi / Frp Type 450Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 58 Erection Erection Of Gi / Frp Type 600Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 59 Erection Erection Of Gi / Frp Type 150 / 100Mm Ladder Tray, Bends And Joints Etc For 2.5 / 3M Length 60 Erection Erection Of Gi / Frp Type 300Mm Ladder Tray, Bends And Joints Etc For 2.5 / 3M Length 61 Erection Erection Of Gi / Frp Type 600Mm Ladder Tray, Bends And Joints Etc For 2.5 / 3M Length 62 Erection Erection Of Gi / Frp Type 50 / 75 / 100Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 63 Erection Erection Of Gi / Frp Type 150Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 64 Erection Erection Of Gi / Frp Type 300Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 65 Erection Erection Of Gi / Frp Type 450Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 66 Erection Erection Of Gi / Frp Type 600Mm Perforated Tray, Bends And Joints Etc For 2.5 / 3M Length 67 Erection Modification & Erection-Gi / Frp Type 150Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 68 Erection Modification & Erection-Gi / Frp Type 300Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 69 Erection Modification & Erection-Gi / Frp Type 450Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 70 Erection Modification & Erection-Gi / Frp Type 600Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 71 Erection Modification & Erection-Gi / Frp Type 50 / 75 / 100Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 72 Erection Modification & Erection-Gi / Frp Type 150Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 73 Erection Modification & Erection-Gi / Frp Type 300Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 74 Erection Modification & Erection-Gi / Frp Type 450Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 75 Erection Modification & Erection-Gi / Frp Type 600Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 76 Erection Modification & Erection-Gi / Frp Type 150Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 77 Erection Modification & Erection-Gi / Frp Type 300Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 78 Erection Modification & Erection-Gi / Frp Type 450Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 79 Erection Modification & Erection-Gi / Frp Type 600Mm Ladder Tray Modification To Bend And Erection 2.5 / 3M Length 80 Erection Modification & Erection-Gi / Frp Type 50 / 75 / 100Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 81 Erection Modification & Erection-Gi / Frp Type 150Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 82 Erection Modification & Erection-Gi / Frp Type 300Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 83 Erection Modification & Erection-Gi / Frp Type 450Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 84 Erection Modification & Erection-Gi / Frp Type 600Mm Perforated Tray Modification To Bend And Erection 2.5 / 3M Length 85 Erection Erection Of Gi / Frp Type-600 Mm Wide Tray Cover 2.5 / 3M Length 86 Erection Erection Of Gi / Frp Type-450 Mm Wide Tray Cover 2.5 / 3M Length 87 Erection Erection Of Gi / Frp Type-300 Mm Wide Tray Cover 2.5 / 3M Length 88 Erection Erection Of Gi / Frp Type-150 Mm Wide Tray Cover 2.5 / 3M Length89 Erection Erection Of C1 Channel For Tray Fixing Including All Tray Fixing Supports & Accessories Meter 90 Erection Erection Of C2 Channel For Tray Fixing Including All Tray Fixing Supports & Accessories Meter 91 Erection Underground Excavation -Upto 1000Mm Below For Ms Earth Rod Laying Meter 92 Erection 40 / 36Mm Dia Ms Rod Laying Underground ( 1000Mm Below ) With Risers Every 20M As Per Specification - ( Approx 9.9Kg / Meter ) & Backfilling Meter 93 Erection Earthing Prot- Running, Connecting To The Earth Risers Of Gs Flats Of 75 Mm X 5 / 6 / 8 / 10 Mm Above The Ground Meter 94 Erection Earthing Prot- Running, Connecting To The Risers Of Gi Flat Of Size 68X5 / 6 / 8 / 10 Mm Above The Ground Meter 95 Erection Earthing Prot- Running, Connecting To The Risers Of Gi Flat Of Size 50X5 / 6 / 8 / 10 Mm Above The Ground Meter 96 Erection Lightning Prot- Running, Connecting To The Risers Of Gi Flat Of Size 25X3 / 4 / 6Mm Above The Ground For Horizontal Down Conductors Meter 97 Erection Lightning Prot-Running, Connecting Of 25X3 / 4 / 5 / 6Mm Gs Flat To The Earth Pit ( Vertical Down Conductor ) Meter 98 Erection Earthing Prot- Running, Connecting Gi Wire Of Size 4 / 6 / 8 / 14 Swg Above The Ground Meter 99 Erection Lightning Prot-Fixing Of The Lightning Spike At The Top Building / 20Mm Dia Air Conductor. No 100 Erection Lightning Prot-Erection Of Water Tight Test Link Boxes No 101 Erection Earthing Prot- Running, Connecting To The Risers Of Gi Flat Of Size 25X3 / 4 / 6Mm Above The Ground Meter 102 Erection Untreated Earth Pit- Driving 3Mtr, 40 Mm Dia Rods Below Fgl And Its Test Links Where Ever Applicable. Pointed Earth Electrode Supplied By Bhel No 103 Erection Digging The Pit ( 3 Meter X 400 Mm Dia ) In Soil No 104 Erection Digging The Pit ( 3 Meter X 400 Mm Dia ) In Soft Rock No 105 Erection Digging The Pit ( 3 Meter X 400 Mm Dia ) In Hard Rock No 106 Erection Treated Earth Pit And Its Test Links - 1No X 3M 65Mm Dia Rods Clamped Electrically With 1No 100 Mm Dia Ci Pipe Earth Electrode - 0.4 M3 Bentonite ( 1 Cubic Meter Of Bentonite Weighs 593 Kilograms ) In Each Pit. Earth Electrode To Be Cut By Contractor From Full Length. Including The Supply Of Bentonte And Salt As Required. Measurement Of Earth Pit Resistance And Recording With Customer Signature. No 107 Erection Treated Earth Pit And Its Test Links - 3Nos X 3M 65Mm Dia Rods Clamped Electrically With 1No 100 Mm Ci Pipe Earth Electrode With - 0.4 M3 Bentonite ( 1 Cubic Meter Of Bentonite Weighs 593 Kilograms ) In Each Pit. Earth Electrode To Be Cut By Contractor From Full Length. Including The Supply Of Bentonte And Salt As Required. Measurement Of Earth Pit Resistance And Recording With Customer Signature. No 108 Erection Construction Of Earth Pit Chamber With Cover ( Complete Concrete ) For Treated Earth Pits As Per Drawing- Supply Of Concrete, Bricks, Reinforcement Rod And Ci Cover Is Included In Bidder Scope No 109 Supply Supply Of Concrete / Insulator Compound Blocks ( Approx 200Mm X 200Mm X 75 Mm ) For Resting Lightning Conductor At Roof Top. No 110 Erection Erection Of Concrete / Insulator Compound Blocks ( Approx 200Mm X 200Mm X 75 Mm ) For Resting Lightning Conductor At Roof Top. No 111 Supply Supply Of Lightning Insulator ( Epoxy Conical ) Suitable For Fixing 75X10mm / 25X4 Gs Flat To Structure / Column With Necessary Mounting Bracket, Gi Clamp, Nut, Bolt Complete With All Hardware With Minimum 60Mm Isolation From Gs. Sets 112 Erection Lightning Insulator ( Epoxy Conical ) Suitable For Fixing 75X10mm / 25X4 Gs Flat To Structure / Column With Necessary Mounting Bracket, Gi Clamp, Nut, Bolt Complete With All Hardware With Minimum 60Mm Isolation From Gs. Sets 113 Supply Supply And Erection Of Clamp For Fixing 75X10mm / 25X4 Gs Flat Along Parapet Walls Sets 114 Supply Supply Of Hardwares ( Nuts, Bolts With Spring & Plain Washers ) For Fitting Of Lightning Conductor ( Horizontal Down Conductors ) Kgs 115 Erection Erection Of Lt Bus Duct-01 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 116 Erection Erection Of Lt Bus Duct-02 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 117 Erection Erection Of Lt Bus Duct-03 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 118 Erection Erection Of Lt Bus Duct-04 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 119 Erection Erection Of Lt Bus Duct-01 Chp Mcc-02 ( From 800A Upto 4000A Rating Bus Duct ) Meter 120 Erection Erection Of Lt Bus Duct-02 Chp Mcc-02 ( From 800A Upto 4000A Rating Bus Duct ) Meter 121 Erection Erection Of Lt Bus Duct-01 Chp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 122 Erection Erection Of Lt Bus Duct-02 Chp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 123 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 124 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 125 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-02A ( From 800A Upto 4000A Rating Bus Duct ) Meter 126 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-02A ( From 800A Upto 4000A Rating Bus Duct ) Meter 127 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-02B ( From 800A Upto 4000A Rating Bus Duct ) Meter 128 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-02B ( From 800A Upto 4000A Rating Bus Duct ) Meter 129 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 130 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 131 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-04 ( From 800A Upto 4000A Rating Bus Duct ) Meter 132 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-04 ( From 800A Upto 4000A Rating Bus Duct ) Meter 133 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-05 ( From 800A Upto 4000A Rating Bus Duct ) Meter 134 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-05 ( From 800A Upto 4000A Rating Bus Duct ) Meter 135 Erection Erection Of External Dry Type Lighting Transformers - Resin Cast 433 / 433V Upto 100Kva No 136 Erection Erection Of Dry Type Transformers - Resin Cast 11 Or 6.6 Or 3.3 / 0.433Kv Above 630Kva Upto 2000Kva No 137 Erection Erection Of Dry Type Transformers - Resin Cast 11 Or 6.6 Or 3.3 / 0.433Kv Above 2000Kva No 138 Erection Erection Of Chp Mcc-01A Located In Chp Mcc-01-No Of Shipping Section Of Apx Length Upto 2.4M No 139 Erection Erection Of Chp Mcc-01A Located In Chp Mcc-01-No Of Shipping Section Of Apx Length Upto 2.4M No 140 Erection Erection Of Chp Mcc-02 Located In Chp Mcc-02-No Of Shipping Section Of Apx Length Upto 2.4M No 141 Erection Erection Of Chp Mcc-03 Located In Chp Mcc-03-No Of Shipping Section Of Apx Length Upto 2.4M No 142 Erection Local Control Panels At Various Locations-No Of Shipping Section Of Apx Length Upto 2.4M No 143 Erection Erection Of Ahp Mcc-1 Loacted In Ahp Mcc-01-No Shipping Section Of Apx Length Upto 2.4M No 144 Erection Erection Of Ahp Mcc-2A Loacted In Ahp Mcc-02-No Shipping Section Of Apx Length Upto 2.4M No 145 Erection Erection Of Ahp Mcc-2B Loacted In Ahp Mcc-02-No Shipping Section Of Apx Length Upto 2.4M No 146 Erection Erection Of Ahp Mcc-3 Loacted In Ahp Mcc-03-No Shipping Section Of Apx Length Upto 2.4M No 147 Erection Erection Of Ahp Mcc-4 Loacted In Ahp Mcc-04-No Shipping Section Of Apx Length Upto 2.4M No 148 Erection Erection Of Ahp Mcc-5 Loacted In Ahp Mcc-05-No Shipping Section Of Apx Length Upto 2.4M No 149 Erection Erection Of 415V Wdb / Mldb With Transfomer Of Rating 50-100Kva ( Floor Mounted ) Size: 4000 Mm ( W ) X 1000 Mm ( D ) X2100 Mm ( H ) Approx. No 150 Erection Erection Of 220V Dc Distribution Board ( Floor Mounted ) Size: 4000 Mm ( W ) X 800 Mm ( D ) X2400 Mm ( H ) Approx. No 151 Erection Erection Of 220V Dc Fuse Board ( Wall Mounted ) At Mcc Rooms. Size: 2000 Mm ( W ) X 800 Mm ( D ) X 2100Mm ( H ) No 152 Erection Erection Of 415V Ac Fuse Board ( Wall Mounted ) At Mcc Rooms. Size: 800Mm ( W ) X 300Mm ( D ) X 850Mm ( H ) Approx No 153 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-1 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 154 Erection Erection Of Ahp Dcs - Rio / Network / Relay / Vms Panels At Ahp Mcc-2 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 155 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-3 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 156 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-4 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 157 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-5 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 158 Erection Erection Of Chp Dcs - Rio / Relay / Network / Vms Panels At Chp Mcc 1 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 159 Erection Erection Of Chp Dcs - Rio / Network / Relay / Vms Panels At Chp Mcc 2 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 160 Erection Erection Of Chp Dcs - Rio / Relay / Network / Vms Panels At Chp Mcc 3 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 161 Erection Erection Of Computer / Hmi Station With Lvs Along With Printer, Table, Chair, Almairah And Furnitures At Various Mcc Locations As Per Equipment Layout Sets 162 Erection Erection Of Data Concentrator Panel No 163 Erection Erection Of Hardwired Backup Control Desk With Mimic Sets 164 Erection Erection Of 220V Dc Battery Charger Chp Mcc 1 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 165 Erection Erection Of 220V Dc Battery Charger Chp Mcc 2 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 166 Erection Erection Of 220V Dc Battery Charger Chp Mcc 3 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 167 Erection Erection Of 220V Dc Battery Charger Ahp Mcc 1 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 168 Erection Erection Of 220V Dc Battery Charger Ahp Mcc 2 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 169 Erection Erection Of Local Panels / Jb / Welding Sockets ( Up To 100 Kg ) No 170 Erection Installtion Of Instruments Like Pressure Switch, Limit Switch, Pcs, Bss, Zss, Temperature Switch, Level Transmitter, Any Field Switches Etc. Including Fabrication And Erection Of Mounting Brackets As Required No 171 Erection Erection Of 220V Dc Lead Acid Plantea Battery Bank ( 108 No Cells ) For Charger At Chp Mcc-01 Including Fuse Box, Discharge Resistor, Racks, Connectors Etc Sets 172 Erection Erection Of 220V Dc Lead Acid Plantea Battery Bank ( 108 No Cells ) For Charger At Chp Mcc-02 Including Fuse Box, Discharge Resistor, Racks, Connectors Etc Sets89 Erection Erection Of C1 Channel For Tray Fixing Including All Tray Fixing Supports & Accessories Meter 90 Erection Erection Of C2 Channel For Tray Fixing Including All Tray Fixing Supports & Accessories Meter 91 Erection Underground Excavation -Upto 1000Mm Below For Ms Earth Rod Laying Meter 92 Erection 40 / 36Mm Dia Ms Rod Laying Underground ( 1000Mm Below ) With Risers Every 20M As Per Specification - ( Approx 9.9Kg / Meter ) & Backfilling Meter 93 Erection Earthing Prot- Running, Connecting To The Earth Risers Of Gs Flats Of 75 Mm X 5 / 6 / 8 / 10 Mm Above The Ground Meter 94 Erection Earthing Prot- Running, Connecting To The Risers Of Gi Flat Of Size 68X5 / 6 / 8 / 10 Mm Above The Ground Meter 95 Erection Earthing Prot- Running, Connecting To The Risers Of Gi Flat Of Size 50X5 / 6 / 8 / 10 Mm Above The Ground Meter 96 Erection Lightning Prot- Running, Connecting To The Risers Of Gi Flat Of Size 25X3 / 4 / 6Mm Above The Ground For Horizontal Down Conductors Meter 97 Erection Lightning Prot-Running, Connecting Of 25X3 / 4 / 5 / 6Mm Gs Flat To The Earth Pit ( Vertical Down Conductor ) Meter 98 Erection Earthing Prot- Running, Connecting Gi Wire Of Size 4 / 6 / 8 / 14 Swg Above The Ground Meter 99 Erection Lightning Prot-Fixing Of The Lightning Spike At The Top Building / 20Mm Dia Air Conductor. No 100 Erection Lightning Prot-Erection Of Water Tight Test Link Boxes No 101 Erection Earthing Prot- Running, Connecting To The Risers Of Gi Flat Of Size 25X3 / 4 / 6Mm Above The Ground Meter 102 Erection Untreated Earth Pit- Driving 3Mtr, 40 Mm Dia Rods Below Fgl And Its Test Links Where Ever Applicable. Pointed Earth Electrode Supplied By Bhel No 103 Erection Digging The Pit ( 3 Meter X 400 Mm Dia ) In Soil No 104 Erection Digging The Pit ( 3 Meter X 400 Mm Dia ) In Soft Rock No 105 Erection Digging The Pit ( 3 Meter X 400 Mm Dia ) In Hard Rock No 106 Erection Treated Earth Pit And Its Test Links - 1No X 3M 65Mm Dia Rods Clamped Electrically With 1No 100 Mm Dia Ci Pipe Earth Electrode - 0.4 M3 Bentonite ( 1 Cubic Meter Of Bentonite Weighs 593 Kilograms ) In Each Pit. Earth Electrode To Be Cut By Contractor From Full Length. Including The Supply Of Bentonte And Salt As Required. Measurement Of Earth Pit Resistance And Recording With Customer Signature. No 107 Erection Treated Earth Pit And Its Test Links - 3Nos X 3M 65Mm Dia Rods Clamped Electrically With 1No 100 Mm Ci Pipe Earth Electrode With - 0.4 M3 Bentonite ( 1 Cubic Meter Of Bentonite Weighs 593 Kilograms ) In Each Pit. Earth Electrode To Be Cut By Contractor From Full Length. Including The Supply Of Bentonte And Salt As Required. Measurement Of Earth Pit Resistance And Recording With Customer Signature. No 108 Erection Construction Of Earth Pit Chamber With Cover ( Complete Concrete ) For Treated Earth Pits As Per Drawing- Supply Of Concrete, Bricks, Reinforcement Rod And Ci Cover Is Included In Bidder Scope No 109 Supply Supply Of Concrete / Insulator Compound Blocks ( Approx 200Mm X 200Mm X 75 Mm ) For Resting Lightning Conductor At Roof Top. No 110 Erection Erection Of Concrete / Insulator Compound Blocks ( Approx 200Mm X 200Mm X 75 Mm ) For Resting Lightning Conductor At Roof Top. No 111 Supply Supply Of Lightning Insulator ( Epoxy Conical ) Suitable For Fixing 75X10mm / 25X4 Gs Flat To Structure / Column With Necessary Mounting Bracket, Gi Clamp, Nut, Bolt Complete With All Hardware With Minimum 60Mm Isolation From Gs. Sets 112 Erection Lightning Insulator ( Epoxy Conical ) Suitable For Fixing 75X10mm / 25X4 Gs Flat To Structure / Column With Necessary Mounting Bracket, Gi Clamp, Nut, Bolt Complete With All Hardware With Minimum 60Mm Isolation From Gs. Sets 113 Supply Supply And Erection Of Clamp For Fixing 75X10mm / 25X4 Gs Flat Along Parapet Walls Sets 114 Supply Supply Of Hardwares ( Nuts, Bolts With Spring & Plain Washers ) For Fitting Of Lightning Conductor ( Horizontal Down Conductors ) Kgs 115 Erection Erection Of Lt Bus Duct-01 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 116 Erection Erection Of Lt Bus Duct-02 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 117 Erection Erection Of Lt Bus Duct-03 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 118 Erection Erection Of Lt Bus Duct-04 Chp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 119 Erection Erection Of Lt Bus Duct-01 Chp Mcc-02 ( From 800A Upto 4000A Rating Bus Duct ) Meter 120 Erection Erection Of Lt Bus Duct-02 Chp Mcc-02 ( From 800A Upto 4000A Rating Bus Duct ) Meter 121 Erection Erection Of Lt Bus Duct-01 Chp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 122 Erection Erection Of Lt Bus Duct-02 Chp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 123 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 124 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-01 ( From 800A Upto 4000A Rating Bus Duct ) Meter 125 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-02A ( From 800A Upto 4000A Rating Bus Duct ) Meter 126 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-02A ( From 800A Upto 4000A Rating Bus Duct ) Meter 127 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-02B ( From 800A Upto 4000A Rating Bus Duct ) Meter 128 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-02B ( From 800A Upto 4000A Rating Bus Duct ) Meter 129 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 130 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-03 ( From 800A Upto 4000A Rating Bus Duct ) Meter 131 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-04 ( From 800A Upto 4000A Rating Bus Duct ) Meter 132 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-04 ( From 800A Upto 4000A Rating Bus Duct ) Meter 133 Erection Erection Of Lt Bus Duct-1 Ahp Mcc-05 ( From 800A Upto 4000A Rating Bus Duct ) Meter 134 Erection Erection Of Lt Bus Duct-2 Ahp Mcc-05 ( From 800A Upto 4000A Rating Bus Duct ) Meter 135 Erection Erection Of External Dry Type Lighting Transformers - Resin Cast 433 / 433V Upto 100Kva No 136 Erection Erection Of Dry Type Transformers - Resin Cast 11 Or 6.6 Or 3.3 / 0.433Kv Above 630Kva Upto 2000Kva No 137 Erection Erection Of Dry Type Transformers - Resin Cast 11 Or 6.6 Or 3.3 / 0.433Kv Above 2000Kva No 138 Erection Erection Of Chp Mcc-01A Located In Chp Mcc-01-No Of Shipping Section Of Apx Length Upto 2.4M No 139 Erection Erection Of Chp Mcc-01A Located In Chp Mcc-01-No Of Shipping Section Of Apx Length Upto 2.4M No 140 Erection Erection Of Chp Mcc-02 Located In Chp Mcc-02-No Of Shipping Section Of Apx Length Upto 2.4M No 141 Erection Erection Of Chp Mcc-03 Located In Chp Mcc-03-No Of Shipping Section Of Apx Length Upto 2.4M No 142 Erection Local Control Panels At Various Locations-No Of Shipping Section Of Apx Length Upto 2.4M No 143 Erection Erection Of Ahp Mcc-1 Loacted In Ahp Mcc-01-No Shipping Section Of Apx Length Upto 2.4M No 144 Erection Erection Of Ahp Mcc-2A Loacted In Ahp Mcc-02-No Shipping Section Of Apx Length Upto 2.4M No 145 Erection Erection Of Ahp Mcc-2B Loacted In Ahp Mcc-02-No Shipping Section Of Apx Length Upto 2.4M No 146 Erection Erection Of Ahp Mcc-3 Loacted In Ahp Mcc-03-No Shipping Section Of Apx Length Upto 2.4M No 147 Erection Erection Of Ahp Mcc-4 Loacted In Ahp Mcc-04-No Shipping Section Of Apx Length Upto 2.4M No 148 Erection Erection Of Ahp Mcc-5 Loacted In Ahp Mcc-05-No Shipping Section Of Apx Length Upto 2.4M No 149 Erection Erection Of 415V Wdb / Mldb With Transfomer Of Rating 50-100Kva ( Floor Mounted ) Size: 4000 Mm ( W ) X 1000 Mm ( D ) X2100 Mm ( H ) Approx. No 150 Erection Erection Of 220V Dc Distribution Board ( Floor Mounted ) Size: 4000 Mm ( W ) X 800 Mm ( D ) X2400 Mm ( H ) Approx. No 151 Erection Erection Of 220V Dc Fuse Board ( Wall Mounted ) At Mcc Rooms. Size: 2000 Mm ( W ) X 800 Mm ( D ) X 2100Mm ( H ) No 152 Erection Erection Of 415V Ac Fuse Board ( Wall Mounted ) At Mcc Rooms. Size: 800Mm ( W ) X 300Mm ( D ) X 850Mm ( H ) Approx No 153 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-1 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 154 Erection Erection Of Ahp Dcs - Rio / Network / Relay / Vms Panels At Ahp Mcc-2 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 155 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-3 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 156 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-4 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 157 Erection Erection Of Ahp Dcs - Rio / Relay / Vms Panels At Ahp Mcc-5 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 158 Erection Erection Of Chp Dcs - Rio / Relay / Network / Vms Panels At Chp Mcc 1 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 159 Erection Erection Of Chp Dcs - Rio / Network / Relay / Vms Panels At Chp Mcc 2 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 160 Erection Erection Of Chp Dcs - Rio / Relay / Network / Vms Panels At Chp Mcc 3 Size: Shipping Section Upto 2400Mm ( W ) X 800Mm ( D ) X 2100Mm ( H ) Approx No 161 Erection Erection Of Computer / Hmi Station With Lvs Along With Printer, Table, Chair, Almairah And Furnitures At Various Mcc Locations As Per Equipment Layout Sets 162 Erection Erection Of Data Concentrator Panel No 163 Erection Erection Of Hardwired Backup Control Desk With Mimic Sets 164 Erection Erection Of 220V Dc Battery Charger Chp Mcc 1 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 165 Erection Erection Of 220V Dc Battery Charger Chp Mcc 2 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 166 Erection Erection Of 220V Dc Battery Charger Chp Mcc 3 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 167 Erection Erection Of 220V Dc Battery Charger Ahp Mcc 1 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 168 Erection Erection Of 220V Dc Battery Charger Ahp Mcc 2 With Fuse Box Size: 2400 Mm ( L ) X 800 Mm ( D ) X 2100 Mm ( H ) Sets 169 Erection Erection Of Local Panels / Jb / Welding Sockets ( Up To 100 Kg ) No 170 Erection Installtion Of Instruments Like Pressure Switch, Limit Switch, Pcs, Bss, Zss, Temperature Switch, Level Transmitter, Any Field Switches Etc. Including Fabrication And Erection Of Mounting Brackets As Required No 171 Erection Erection Of 220V Dc Lead Acid Plantea Battery Bank ( 108 No Cells ) For Charger At Chp Mcc-01 Including Fuse Box, Discharge Resistor, Racks, Connectors Etc Sets 172 Erection Erection Of 220V Dc Lead Acid Plantea Battery Bank ( 108 No Cells ) For Charger At Chp Mcc-02 Including Fuse Box, Discharge Resistor, Racks, Connectors Etc Sets173 Erection Erection Of 220V Dc Lead Acid Plantea Battery Bank ( 108 No Cells ) For Charger At Chp Mcc-03 Including Fuse Box, Discharge Resistor, Racks, Connectors Etc 174 Erection Erection Of 220V Dc Lead Acid Plantea Battery Bank ( 108 No Cells ) For Charger At Ahp Mcc-01 Including Fuse Box, Discharge Resistor, Racks, Connectors Etc 175 Erection Erection Of 220V Dc Lead Acid Plantea Battery Bank ( 108 No Cells ) For Charger At Ahp Mcc-05 Including Fuse Box, Discharge Resistor, Racks, Connectors Etc 176 Erection Installation Of Junction Box , Mounting Pad Phase Marker Bracket , Shaft Vibration Sensors & Other Related Accessories Near Ht Drives And Its Driven Equipment In The Field. ( 1 Set Consists Of Total 10 Sensors -5 For Drive / 5 For Driven Equipment And Its Jb / Cabling From Sensor To Jb ) 177 Erection Installation Of Junction Box , Mounting Pad Phase Marker Bracket , Shaft Vibration Sensors & Other Related Accessories Near Ht Drives In The Field. ( 1 Set Consists Of Total 5 Sensors For Motor And Its Jb / Cabling From Sensor To Jb ) 178 Erection Ground Leveling - ( Excavation ) For Earthing Works If Instructed By Bhel 179 Erection Ground Leveling - ( Backfilling ) For Earthing Works If Instructed By Bhel 180 Erection Misc Civil Works- Making Openings In Existing Brick Wall / Sheet Steel 181 Erection Application Of Diamond Core Cutting Work Using Hilti Make Dd200 / 350 With Hilti System Including Machine, Consumable, Labour Etc. Complete. Size: Mm Dia. & 200 Mm Depth. 182 Supply Supply Of Chequered Plate For Covering Unsafe Electrical Openings With Chequered Plate Of 6Mm Thick As Instructed By Site Incharge 183 Erection Erection Of Covering Unsafe Electrical Openings With Chequered Plate Of 6Mm Thick As Instructed By Site Incharge 184 Erection Misc Civil Works- Chipping / Cutting Of Concrete In Reinforced Concrete Work 185 Erection Embedments Including Supply, Fabricating And Fixing Of Mild Steel Embedments-Supply And Erection 186 Erection Anchor Bolts Including Supply & Fixing-Supply And Erection 187 Erection Preparation Of Cable Trench ( 1Meter Below ) For Underground Buried Cable As Per Is 1255. Quantity Mentioned Is The Excavated Soil / Ground Volume . Supply Of Bricks , Soil Included In The Bhel Scope. 188 Erection Testing, Commissioning And Charging Of Treated Earth Pits / Earth Grid In Each Equipment Area - 10 Fine Readings In Each Area As Per Technical Specification One Grid Means All The Earth Pits Of A Building In Totality Including Both Earthing And Lightning Along With Submisison Of Report ( Mcc, Jnt, Ph, Con Gallery, Cable Rack Etc ) ( 1 Unit =1 Building ) 189 Erection Testing, Commissioning And Charging Of Mcc Boards - ( Includes All Protection Relay , Ct, Bpt, Lpt , Ctd, Ammeter, Voltemeter, Acb Breaker, Dol / Rdol / Feeder Testing, Scheme Check , Operation In Load , Current Measurement , Etc ) 190 Erection System Study Including Fault Level Calculations And Relay Setting And Relay Co-Ordination For 6.6Kv And 415V Systems For The Entire Distribution Network Applicable For Chp And Ahp. The Study Report Will Substantiate All The Input Data / Parameters, Various Technical Considerations, Detailed Design Calculations In An Explanatory Way. It Will Also Contain The Charts For Recommended Settings Of Idmt & Dmt Graphs, Major Calculations, Protection Calculations, Etc. Both Hard Copy And Editable Data Files Of The System Studies Will Be Furnished For Online Review By Bhel / Tce / Tangedco 191 Erection Testing, Charging And Commissioning Of Mldb, Wdbs , Acdb, Dcdb , Pdb ( Outgoing Feeders ) 192 Erection Testing, Charging And Commissioning Of Dcs Panels ( Power , Di / Do / Ao / Ai / Communication Modules ) 193 Erection Testing, Charging And Commissioning Of Relay Panels ( Relay Energisation From Hmi & Output Voltages ) 194 Erection Testing, Charging And Commissioning Of Vms Panels 195 Erection Testing, Charging And Commissioning Of Dcs / Vms Field Input / Outputs Signals & Instruments From Hmi 196 Erection Testing, Charging And Commissioning Of Battery Systems ( Arranging Resistor Bank For Testing / Discharge Test & Charging Of Battery Banks ) 197 Erection Testing, Charging And Commissioning Of Transformers & Busducts Including Vcb Operational Checks 198 Erection Testing, Charging And Commissioning Of Ht Motors Including Vcb Operational Checks 199 Erection Deputation Of Testing Team With Required Kits , Tools & Plants For Additional Testing & Commissioning Requirements. 200 Erection Supply & Erection Of Tarpaulin Covers For Storage 201 Supply Erection Of Gs Angle ( 40 X 40 X 5 Angle For Posts & Gate Materials ) Including The Supply 202 Supply Erection Of Galvanised Barbed Wire For Fencing - ( 13 X 13 Swg ) Including The Supply 203 Supply Providing Concrete Mixture For Grouting Of Fence Posts Including The Supply 204 Erection Supply & Erection Of Hardwares : Ss Nuts , Bolts With Spring & Plain Washers Of Various Sizes As Instructed By Bhel Site Team 205 Supply Supply Of 11Kv Electrically Tested Rubber Gloves. 206 Erection Supply & Erection Of Rubber Mats For Insulation - 3Mm Thick Of Width 1M To Withstand Voltage Classs Upto 33Kv 207 Erection Supply & Erection Of Fire Extinguisher ( 4Kg - Co2 Type ) 208 Erection Supply & Erection Of Fire Buckets ( 4Nos In Each Set ) With Stand 209 Erection Supply & Mounting Of Caution / Danger Board In English , Hindi, Tamil 210 Erection Supply & Erection Of First Aid Kits ( As Per Hse Document ) 211 Erection Identification / Marking Of Equipments Painting ( Yellow Base And Black Coloured Letter ) - Considering 16 Letters X ( 8-15 ) Mm Height Each. 212 Erection Lamination , Framing & Mounting Of Chp / Ahp Flow Diagrams In Control Room- A0 Size. 213 Erection Vacuum / Blower - Cleaning Of Mcc , Dcs And Other Panels & House Keeping Of Mcc Buildings & Control Rooms - 6 Times Cleaning * 9 Mcc Buildings. 214 Supply Supply Of Fire Proof Sealing- ( As Per Customer Nit Spec ) -Panel Based Type For 1 Hour Withstand Capacity Below Switchgear Panels 215 Erection Erection Of Fire Proof Sealing- ( As Per Customer Nit Spec ) -Panel Based Type For 1 Hour Withstand Capacity Below Switchgear Panels 216 Supply Supply Of Fire Proof Sealing- ( As Per Customer Nit Spec ) -Mortor Based Type For 1 Hour Withstand Capacity For Wall / Cutout Openings 217 Erection Erection Of Fire Proof Sealing- ( As Per Customer Nit Spec ) -Mortor Based Type For 1 Hour Withstand Capacity For Wall / Cutout Openings 218 Supply Supply Of Fire Retardant Paints ( As Per Customer Nit Spec ) - For 40Minutes Withstand Capacity 219 Erection Erection Of Fire Retardant Paints ( As Per Customer Nit Spec ) - For 40Minutes Withstand Capacity 220 Erection Statutory Clearance-Registering , Applying And Submision Of Drawing & Testing Documents To Electrical Inspector In Hard Copies For The Electrical Equipments Of Chp And Ahp Area 221 Erection Statutory Clearance-Field Inspection And Obtaining Inspector Clearance, Inspector Fee, Obtaining Cea Clearance Certificate Etc For The Electrical Equipments Of Chp And Ahp Area 222 Erection Cutting , Fabrication , Fitting & Installation Works Of Steel -As Per Site Rquirement 223 Supply Supply Of Erection Steel Of Various Sizes As Per Site Requirement 224 Erection Cutting , Fabrication , Fitting & Installation Works Of Gi Sheet- As Per Site Requirement 225 Supply Supply Of Gi Sheet Of Thickness 2Mm As Per Site Requirement 226 Supply Supply Of 32 Mm Dia Flexible Conduit Along With Couplers 227 Erection Erection Of Gs Flexible Pipes Of Up To 32 Mm Nominal Bore 228 Supply Supply Of 32 Mm Dia Gi Conduit Along With Couplers 229 Supply Supply Of Spacers , Saddles & Bolts For 32 Mm Dia Gi Conduit 230 Erection Erection Of Gi Conduits Upto 32Mm Dia Along With Accessoroies231 Supply Supply Of 100 Mm Dia Gi Pipe 232 Erection Erection Of Gi Pipes Of Upto 100 Mm Nominal Bore 233 Supply Supply Of Terminal Blocks ( For Cable Terminations In Bidder Scope ) For 0.5 / 2.5 Sqmm Cable 234 Supply Supply Of Shorting Links For Tb Shorting. 235 Supply Supply Of Copper Bus Bars 236 Supply Supply Of Cjb - 80 Terminal Control Junction Box 237 Supply Supply Of Cjb - 50 Terminal Control Junction Box 238 Supply Supply Of Pjb - With Bus Bar To Facilitate 240Sqmm Cable 4 Runs 239 Supply Supply Of Isi Marked Pvc Pipes - 32Mm Dia 240 Erection Erection Of Isi Marked Pvc Pipes - 32Mm Dia 241 Supply Supply Of Cotton Waste, Cleaning Cloth Etc 242 Supply Supply Of Heavy Duty Pvc Pipes - 90Mm Dia Laying On Ground / Trench 243 Erection Erection Of Heavy Duty Pvc Pipes - 90Mm Dia Laying On Ground / Trench 244 Supply Supply Of Hume Pipe Type Np2 - 300 Mm Dia Laying On Ground / Trench 245 Erection Erection Of Hume Pipe Type Np2 - 300 Mm Dia Laying On Ground / Trench 246 Erection Skilled Manpower For Additonal Electrical E&C Works As Per Tech Spec 247 Erection Un Skilled Manpower For Additional Electrical E&C Works As Per Spec. 248 Erection Commissioning Engineer For Plant Maintenance Services Envisaged For Cod , Reliability Run , Pg Test Handing Over To Customer 249 Erection Electrician For Commissioning Services 250 Erection Commissioning Engineer -Coordination, Inspection Of Each Area , Attending The Faults , Demonstration Of Trouble Shooting Procedures , Operation And Functioning Of All Electrics , C&I And Dcs / Plc Systems During Continuous Plant Operation Towards Handing Over 251 Erection Electrician For Commissioning Compliances

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Dec-2023 Due date extension Date 28-12-2023

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document