| 1 | M&L for dismantling/taking down old corroded angle bracing of any size or type/pressed steel plate/nuts, bolts & washers etc inside the pressed steel overhead tank capacity 9600 Gallon mounted on 15 mtr staging tank of any description by dismantling the welding joints from gusset plate complete all as required at site to repair these all as specified and directed. |
| 2 | M&L for replacement of angle iron bracing of size and thickness as per existing (65x65x6mm) inside the steel overhead tank/clear water tank/ladder,platform and similar workincluding making necessary arrangement for holding of surrounding plates and bracing, cutting of gusset plates to required sizes and shape & angle for joiting with bracings by drilling holes welding of web piece with gusset plate wherever required after making proper shape etc complete at the height not less than 15 mtr all as specified and as directed. |
| 3 | M&L for dismantling/taking down old corrogated/MS plain sheet top cover of any thickness from the pressed steel OH tanks by unscrewing nuts & bolts and washers of suitable size complete all as specified. |
| 4 | S & F 1.60 mm thick mild steel, plain, black sheet in hearths; covering to door shutters; covering to door chowkhats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed. |
| 5 | Dismantling and taking down old corroed PS plate of any size from the pressed steel over head tank by unscrewing nut & bolts or cutting joints and removing of nut & bolts etc including joiting material complete at the height of 15 mtrs complete all as specified and directed. |
| 6 | S&F factory made factory made pressed steel plate of size 1.22m x 1.22 x 6mm thick fixed with suitable size nuts and washers including all jointing material such as lead wool, gasket, non toxic black puitty washer etc and applying two coats of anti corrosive paint suitable for potable water complete at the height of 50 feet approx all as specified and directed. |
| 7 | M&L for painting of complete tank (external surface) of capacity 9600 Gallon including staging, ladder, rasing & delivery mains with two coats of synthetic enamel paint (one unded coat, one finishing coat) after preparartionsurface ,one coat of primer red oxide zinc chromium & unwanted foreign material with wire brush, complete at the height 15 mtr all as specified and directed. |
| 8 | M&L for applying two coats of anticorrosive bituminuos paint lead free suitable for potable water to internal surfaces of PS tank of capacity 9600 gallon after preparartion of old painted surfacerust and any other unwanted foreign material with wire brush, complete at the height 15 mtr all as specified and directed. |
| 9 | M&L for construction for MS float box made out of MS Sheet 1.6mm thick and of size 30 x 30x 25cm complete painting black bituminuos paint incl supply and fixing of nylon rope of including construction of water level indicatorof existing size made out of MS sheet of 1.6mm thick complete including painting with super anamelled paint of white colour duly marked with water levels in red colour showing the levels of water inside the overhead tank including arrow of existing size painted with red colour and fixed at the height of 50 feet and testing complete all as specified and as directed. |
| 10 | Takingup ordownGItubing/PPRincluding all fittings from trenches, wall, floor of size 100 mm bore etc including cleaning by roding for refixing or removing to store forsafe custody/ reuse or disposal under schedule of credit and all as specified for the following sizes:-(for wash out/tank inlet/tank outlet) |
| 11 | Takingup ordownGItubing/PPRincluding all fittings from trenches, wall, floor of size 80 mm bore etc including cleaning by roding for refixing or removing to store forsafe custody/ reuse or disposal under schedule of credit and all as specified for the following sizes:-(for wash out/tank inlet/tank outlet) |
| 12 | Supplying & laying in trenches 100 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 13 | Supplying & laying in trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 14 | Supply and fix MS flange heavy duty complete with nuts bolts and washers 06 nos suitable for 100 mm dia GI pipe complete all as specified and directed. |
| 15 | Supply and fix MS flange heavy duty complete with nuts bolts and washers 06 nos suitable for 80 mm dia GI pipe complete all as specified and directed. |
| 16 | M&L for construction for MS float box made out of MS Sheet of 1.6mm thick and of size 30 x 30 x 25cm complete painting with black bituminous paint including supply and fixing of nylon rope of suitable size at the height of approx 50 feet testing complete all as directed. |
| 17 | M&L for construction for water level indicator of existing size made out of MS Sheet of 1.6mm thick complete including painting with super enamelled paint of white colour duly marked the water levels in red colour showing the levels of water inside the overhead tank includingaero of existing size painted with red colour and fixed at the height of approx 50 feet testing complete all as directed. |
| 18 | Supply and fix cast iron sluice valve 100 mm bore with stainless steel spindle and cast iron hand wheel complying with IS : 14846-2000, class PN 1.6 both ends flanged with 2 Nos rubber gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unserviceable onecomplete all as specified and as directed |
| 19 | Dismentling the old one &Material and labour for construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of bituminious paint over a coat of red oxide primer on steel surfaces and ncessary earth work in soft/loose soil complete all as specified and as directed |
| 20 | Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed. |
| 21 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed. |
| 22 | M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 23 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 24 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 25 | M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 26 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. |
| 27 | M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed. |
| 28 | M&L for plinth protection or in foot path of 75 mm thick of cement concrete using type C-1, 1:3:6 (using 20 mm nominal size crushed and graded stone aggregate) in alternate penals and finished fair and even complete in all respect as specified and directed. |
| 29 | Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 30 | M & L for rendering15mm thick cement plaster in cm 1:4 on fair faces brick or concrete surfacesusing water proofing compound of wall (WPC added only 5 mm thick plaster) including finished even and smooth without using extra cement complete all as specified and as directed. |
| 31 | Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed. |
| 32 | M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed. |
| 33 | M&L coloured glazed ceramic tiles in vertical surface 200x300x7mm/350x 250x 7 mm/ 450X 350X 7mm thick set and jointedin floors, skirting/dados etc neat cement slurry and pointed in white or colour cement to match all as specified. |
| 34 | M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.06sqmbut not exceeding 0.11 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed. |
| 35 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. |
| 36 | S&F for steel work in tubular trussess / postsincluding special shaped washers etc complete using ERW or including butt welded tubes confirming to IS 1161 - 1979 grade St -240., structural steel is painted one shop coat of zinc chromate primer paint (incl preparation of surface) at contractor\"s workshop before fabrication complete all as specified and directed. |
| 37 | S & F mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long complete all as specified and as directed. |
| 38 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge |
| 39 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 40 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 41 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 42 | Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed. |
| 43 | S & F stop valves of PTMT with long shank and cup (concealed type), any colour, high pressure, minimum weight 112 grams, screwed for steel tube for nominal size 20 mm complete all as specified and as directed. |
| 44 | S & F 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed. |
| 45 | S&F ofstop/angle valves chromium plated, cast copper alloy with fancy type handles screwed down, screwed for iron pipe or for brass ferrule 15mm bore as in repair complete all as specified and directed. |
| 46 | S & F in repair Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union along with arm 225 mm and flange Complete all as specified and directed (Make Cat No OHS-35495 of Jaquar or equivalent of Kohler / Marc). |
| 47 | S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 48 | S&F in repairs Soap dish complete all as specified and directed. |
| 49 | S & F 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 50 | S & F wash basins, vitreous china, white, flat back, size 630 mm X 450 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed. |
| 51 | S & F 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed. |
| 52 | S & F 32 mm nominal size, waste coupling of PTMT (half or full threaded), minimum weight 45 grams with including silicone sealant complete all as specified and as directed. |
| 53 | Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge. |
| 54 | M&L for preparation of new plastered or undecorated surfaces of wall using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 55 | Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge. |
| 56 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails.M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel haivng a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for top rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the M.S. frame weloded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site as per specification & drawing, complete in all respcet as specified and directed. |
| 57 | S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 58 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 59 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 60 | M&L point wiring for light point/fan/bell pointcontrolled by one, one way switch/bell push using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated sheathed FRLS cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceilingincluding PVC closed recessed boxes confirming to IS-14772-20000 for mounting of switches/sockets/regulators/bell push etcand1.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc. complete. |
| 61 | M&L wiring for one 3/5 pin socket outlet 5 amps on independent board using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated sheathed FRLS cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceilingincluding PVC closed recessed boxes confirming to IS-14772-20000 for mounting of switches/sockets etcand1.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc. complete all as specified. |
| 62 | M&L wiring for one 3 pin socket outlet 15 amps on independent board using 2.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated sheathed cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceilingincluding PVC closed recessed boxes confirming to IS-14772-20000 for mounting of switches/sockets etcand 2.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers complete all as specified and directed. |
| 63 | Supply and fix switch piano flush type single pole, one way, 5/6 Amps complete all as specified and directed. |
| 64 | S & F switch socket combination 2 in one, 5 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed. |
| 65 | Supply and fixofswitch socket combination 2 in one , 5 pin 5 Amps & 15 Amps flush type, universal complete all as specified and directed. |
| 66 | Supply and fix in replacement wall mounted LED tubelight fittingbatten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver lamp type 20 watt 6000K 4 feet.Make: Havells/surya/philipsor equivalent make |
| 67 | S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. |
| 68 | S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holderconnecting up with three core flexible copper conductor cable of suitable size.Make: Havells/surya/philipsor equivalent make |
| 69 | M&L ceiling rose,surface bakelite 65x50mm two to three terminal complete all as specified and directed. |
| 70 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of 16-32 amps SPN and current carrying capacity in the MCB DB complete with connection testing and commissioning.Note: MCB SPN amps rating should be design on the base of load of the fitting/fixture used no overload current permissible or damage to wiring cable or as directed by Engr in Charge. |
| 71 | S & F sheet metal enclosuredouble door for DBs SPN 4 way 240 V completedouble door, flush mounted all as specified and as directed |
| 72 | Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire and taking down complete all as specified and as directed. |
| 73 | M & L for house service bracket (hook type complete with 3.0 m long galvanised iron pipe 40 mm dia medium grade, two Nos 900 bends mild steel hook and stay or guy complete all as specified and as directed. |
| 74 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. |