Military Engineer Services-MES has published Tender For Maintenance Repairs Overhauling Of Ceiling Fan Exhaust Fan Wall Mounted Fan Air Circulator Including Water Heater And Allied Items At Permanent Buildings Etc Repair And Replacement Of Db Dccb Mcb And Certain Internal Electrical Supply Wor. Submission Date for this Tender is 05-01-2024. Air Circulators Tenders in arakkonam Tamil Nadu. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 16-Dec-2023 | Revised BOQ | BOQ | 29-12-2023 |
2 | 29-Dec-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 05-01-2024 |
Sl. No. | Item Description |
1 | Taking down ceiling fans of any make and sweep from ceiling hook/existing position complete including disconnectingand transporting to workshop for repairs complete all as specified and as directed. |
2 | Servicing/ over hauling of ceiling fan of any make and sweep including labour cost for dismantling, replacement of worn out spare parts,reassembling and testing for smooth functioning all as specified and as directed. Note: (a) Spare parts will be measured and paid separately as supply only under items of Sch "A" (b) Labour cost for replacement of worn out spare parts deemed to include in the unit rate quoted. |
3 | Supply only ceiling fan mounting clamp with Rubber bush with nut and bolt suitable for ceiling fan any sizecomplete all as specified and as directed. |
4 | Supply only ball bearing suitable for ceiling fan 1200/1400mm sweep of any make complete all as specified and as directed. |
5 | Supply only down rod 60cm long suiatable for ceiling fan complete all as specified and as directed. |
6 | Supply only down rod 100cm long suiatable for ceiling fan complete all as specified and as directed. |
7 | Supply only canopy suitable for ceiling fan all as directed. Note for Item 03 to 07 here-in-before:Labour cost deemed to include in the rate quoted for Servicing/ over hauling of fan. |
8 | Supply only Capacitor 2.5 MFD, AC 250 volts capacity complete all as specified and as directed. |
9 | Supply only capacitor 4.5 MFD, AC 250 volts capacity complete all as directed. Note for Item 8 and 9 here-in-before:Labour cost deemed to include in the rate quoted for Servicing/ over hauling of fans. |
10 | Taking down Exhaust fans of any make and sweep from existing position complete including disconnectingand transporting to workshop for repairs complete all as specified and as directed . |
11 | Servicing/ over hauling of exhaust fan of any make and sweep including labour cost for dismantling, replacement of worn out spare parts, reassembling and testing for smooth functioning complete all as specified and as directed. Note: (a) Spare parts will be measured and paid separately as supply only under items of Sch "A" (b) Labour cost for replacement of worn out spare parts deemed to include in the unit rate quoted. |
12 | Supply only ball bearing suitable for Exhaust fan 300 to 450mm sweep of any make complete all as specified and as directed. Note:Labour cost deemed to include in the rate quoted for Servicing/ over hauling of fan. |
13 | Taking down Wall mounted/Pedestal fans of any make and sweep from existing position complete including disconnecting and transporting to workshop for repairs complete all as specified and as directed. |
14 | Servicing/ over hauling wall mounted/pedastal fan of any make and sweep including labour cost for dismantling,replacement of worn out spare parts,reassembling and testing for smooth functioning all as specified and as directed. Note: (a) Spare parts will be measured and paid separately as supply only under items of Sch "A" (b) Labour cost for replacement of worn out spare parts deemed to include in the unit rate quoted. |
15 | Supply only ball bearing suitable for Wall mounted fan any sweep all as directed. Note:Labour cost deemed to include in the rate quoted for Servicing/ over hauling of fan. |
16 | Taking down Air circulator fans of any make and sweep from walls/ trusses complete including disconnectingand transporting to workshop for repairs complete all as specified and as directed. |
17 | Servicing/ over hauling of Air circulators including labour cost for dismantling,replacement of worn out spare parts,reassembling and testing for smooth functioning complete all as specified and as directed. Note: (a) Spare parts will be measured and paid separately as supply only under items of Sch "A" (b) Labour cost for replacement of worn out spare parts deemed to include in the unit rate quoted. |
18 | Supply only ball bearing suitable for Air circulator fan 450/600mm sweepcomplete all as specified and as directed. Note:Labour cost deemed to include in the rate quoted for Servicing/ over hauling. |
19 | Material and labour for rewinding of burnt out fan motor of following fans with super enameled copper winding wire of existing gauge/size including necessary tapping, varnishing and dismantling,taking down burnt copper winding,reassembling and testing for smooth functioning complete all as specified and as directed. |
20 | Ceiling fan 1200/1400mm sweep of any make |
21 | Exhaust fan 450mm sweep of any make |
22 | Exhaust fan 300mm sweep of any make |
23 | Pedestal / Wall mounted fan upto 450mm sweep of any make |
24 | Air circulator fan 450mm sweep.single phase |
25 | Air circulator fan 600mm sweep.single phase |
26 | Material and labour for Painting to following fans complete with two coats of synthetic enamel paint of approved tint including cleaning, scrapping complete all as specified and as directed. |
27 | Ceiling fan 1200/1400mm sweep of any make |
28 | Exhaust fan 450mm sweep of any make |
29 | Exhaust fan 300mm sweep of any make |
30 | Air circulator fan any sweep |
31 | Hanging only ceiling fans any make and sweep after repairs to ceiling hook by connecting with 3 core copper flexible round cable from ceiling rose to fan complete incl shifting from workshop complete all as specified and as directed. |
32 | Fixing only Exhaust fans after repairs (fan of any make and sweep) by connecting with 3 core copper flexible round cable from ceiling rose to fan complete incl shifting from workshop complete all as specified and as directed . |
33 | Fixing only air circulator fans of any make and sweep after repairs by connecting with 3 core copper flexible round cable from ceiling rose to fan complete incl shifting from workshop complete all as specified and as directed. |
34 | Fixing only wall mounted fans of any make and sweep after repairs by connecting with 3 core copper flexible round cable from ceiling rose to fan complete incl shifting from workshop complete all as specified and as directed . |
35 | Taking down storage water heater of any make and any capacity complete from existing positionincluding disconnecting all connection, dismantling and keep aside for repairs and reassembling and refixing complete all as specified and as directed . |
36 | Supply and fix heating element 1500/2000 watts any type as per site requirement for any make of electric water heater including taking down U/S heating element complete all as specified and as directed . |
37 | Supply and fix in existing position of thermostat for Geyser any type including taking down U/S thermostat complete all as specified and directed. |
38 | Supply and fix hot water/cold water connection pipe of 600mm length with check nuts and washers in existing positionincluding taking down old u/s complete all as specified. |
39 | Supply and fixing copper siphon assembly suitable for 50 ltr capacity geysers any make and type as required at site of approved make complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket all as specified and as directed incl taking down U/S siphon assembly. |
40 | All as per item No.29 here-in-above but siphon assembly suitable for 25 ltrs capaity Geysers. |
41 | Supply and fix single pole and neutral enclosure240 volts with two pin and earth plug socket complete with one single pole MCB 240 V 32amp complete all as specified and as directed. |
42 | Supply and fixing Gun metal or globe valve of 20 mm bore with iron wheel headed screwed both ends for GI pipe and fixed complete all as specified and as directed. |
43 | Supply and fixing Gun metal or globe valve of25mm bore with iron wheel headed screwed both ends for GI pipe and fixed complete all as specified and as directed. |
44 | Supply and fix in repairs Bib tap 15 mm bore, brass, chromium plated, fancy type with crutch or butterflyhandle conforming to relvent IS,screwed down, screwedfor iron pipes or for brass ferrule complete all as specified and as directed. |
45 | Material and labour for taking down unserviceable digital energy meter(KWH) single phase after disconnection of all electric connection and transporting to authorised service center and servicing and replacement of defective components and LCD display of meter including calibration and testing for complete functioning and refixing in its position and making necessary connections complete all as specified and as directed . |
46 | Supply and fixing in repair of fan regulator electronic deluxe rotary step type complete all as specified and as directed |
47 | Supply and fix louver shutter suitable for 300mm exhaust fan of any make and sweep including taking down old damaged corroded unserviceable shutter complete all as specified and as directed. |
48 | Supply and fix louver shutter suitable for 380mm exhaust fan of any make and sweep including taking down old damaged corroded unserviceable shutter complete all as specified and as directed. |
49 | Supply and fix louver shutter suitable for 450mm exhaust fan of any make and sweep including taking down old damaged corroded unserviceable shutter complete all as specified and as directed. |
50 | Material and labour for fixing metal mesh with fine holes for exhaust fans of 300mm including taking down existing old u/s mesh complete all as specified and as directed. |
51 | Supply and fix 230 V, 1200mm smart saver-50 complete all as specified and as directed . |
52 | Supply and fix 300 mm, 230 Volt heavy duty exhaust900 RPM of complete all as specified and as directed . |
53 | Supply and fix 400 mm, 230 Volt wall mounted of complete all as specified and as directed. |
54 | Supply and fix 230 Volt PVC exhaust fan high speed with shutter 150mm / 200 mm / 250 mm of complete all as specified and directed . |
55 | Taking down unserviceable sub main wiring aluminuim conductor of any size along with earth wire of any sizes complete all as specified and as directed . |
56 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including PVC conduit medium grade of suitable dia complete with fittings and fixings accessories complete all as specified and as directed. |
57 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including PVC conduit medium grade of suitable dia complete with fittings and fixings accessories complete all as specified and as directed. |
58 | All as per Item no 57 here-in-before but sub main wiringtwo single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire all as specified and as directed. |
59 | Supply and fixplug top 15amps 3 Pin suitable for AC 230 volts 50 Hz including taking down unserviceable plug top complete all as specified and as directed . |
60 | Supply and fixplug top 5amps 3 Pin suitable for AC 230 volts 50 Hz including taking down unserviceable plug top complete all as specified and as directed . |
61 | Supply and fix metal plug top20 Amp 2 pin Phase + neutral suitable for SPN enclosure AC 230 volts 50 Hz including taking down unserviceable metal plug top complete all as specified and as directed . |
62 | Supply and fix metal plug top 32 Amp 3 pin 3phase suitable for SPN enclosure AC 230 volts 50 Hz including taking down unserviceable metal plug top complete all as specified and as directed. |
63 | Supply and fix metal plug socket 20 Amp 2 pin Phase + neutral suitable for SPN enclosure AC 230 volts 50 Hz including taking down unserviceable metal plug socketcomplete all as specified and as directed . |
64 | Supply and fix metal plug socket 32 Amp 3 Phase suitable for SPN enclosure AC 230 volts 50 Hz including taking down unserviceable metal plug socketcomplete all as specified and as directed. |
65 | Supply and fix heating element in existing position 3000 watts any type as per site requirement for any make of solar water heater as per site requirementincluding taking down U/S heating element complete all as specified and as directed . |
66 | Supply,install and testing Flat plate collector suitable for solar water heater 500 LPD of any make/type incl mounting arrangement/PCC/Steel structure complete including dismantling and taking down old unserviceable/damaged collector all as specified and as directed. |
67 | Supply and fix in repair for hot water pipe duly insulated with glass wool and aluminium clading of size 20mm bore including taking down old corroded pipe/ worn out clading complete all as specified and as directed . |
68 | Supply and fix in repair for hot water pipe duly insulated with glass wool and aluminium clading of size 25mm bore including taking down old corroded pipe/ worn out cladingcomplete all as specified and as directed . |
69 | Supply,hoisted and fixed in position rotational moulded polyethylene water storage tank of capacicty 500 Ltrs (Cylindrical vertical with closed top) including dismantling and taking down old unserviceable/damaged tankcomplete all as specified and as directed . |
70 | Supply,hoisted and fixed in position rotational moulded polyethylene water storage tank of capacicty 1000 Ltrs (Cylindrical vertical with closed top) including dismantling and taking down old unserviceable/damaged tank complete all as specified and as directed . |
71 | Supply,hoisted and fixed in position Solar water collector(heat exchanger)made out of stainless steel alongwith puff insulation of capacity 200 ltrs with electrical heating backup of 2 KW suitable for replacement of existing unserviceable solar water heater any make including dismantling and taking down old unserviceable/damaged solar water tank complete all as specified and as directed . |
72 | Supply,hoisted and fixed in position Solar water collector(heat exchanger)made out of stainless steel alongwith puff insulation of capacity 500 ltrs with electrical heating backup of 2 KW suitable for replacement of existing unserviceable solar water heater any make including dismantling and taking down old unserviceable/damaged solar water tankcomplete all as specified and as directed. |
73 | Supply and laying of CPVC pipes SDR 11 of outer dia 32mm including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete including taking down old corroded GI pipe complete all as specified and as directed . |
74 | Supply and laying of CPVC pipes SDR 11 of outer dia 25mm including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete including taking down old corroded pipe complete all as specified andas directed. |
75 | Supply and fix single pole and neutral enclosure240 volts with two pin and earth plug socket complete with one single pole MCB 240 V 32ampcomplete all as specified and as directed. |
76 | Supply and fix in repairs Bib tap 15 mm bore, brass, chromium plated, fancy type with crutch or butterflyhandle conforming to IS, screwed down, screwedfor iron pipes or for brass ferrule complete all as specified and as directed. |
77 | Material and labour for taking down unserviceable digital energy meter(KWH) single phase after disconnection of all electric connection and transporting to authorised service center and servicing and replacement of defective components and LCD display of meter including calibration and testing for complete functioning and refixing in its position and making necessary connections complete all as specified and as directed. |
78 | Supply and fixing in repair of fan regulator electronic deluxe rotary step type complete all as specified and as directed. |
79 | Taking down flame proof Exhaust fans of any make and sweep from existing position complete including disconnectingand transporting to workshop for repairs/over hauling including Matreial and labour cost for dismantling,rewinding of burnt out fan motor with super enameled copper winding wire of existing gauge/size,over hauling,replacement of worn out spare parts,reassembling and testing for smooth functioning complete all as specified and as directed . |
80 | Taking down unserviceable flame proof ceiling fans of any make and sweep from existing position complete including disconnecting and transporting to workshop for repairs/over hauling including Matreial and labour cost for dismantling,rewinding of burnt out fan motor with super enameled copper winding wire of existing gauge/size including necessary tapping, varnishing incl taking down burnt copper winding,replacement of worn out spare parts,reassembling and testing for smooth functioning complete all as specified and as directed. |
81 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. complete all as specified and as directed. |
82 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copperconductor wire drawn intoexistingconcealedconduit including provision of 1.5Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- |
83 | One light point controlled by one switch. |
84 | One fan point controlled by one switch. |
85 | One Exhaust fan point controlled by one switch. |
86 | One 3 pin socket outlet 5 Amps, sameboardwith cables 1.5 Sqmm size. |
87 | One 3 pin socket outlet 5 Amps, independentboardwith cables 1.5 Sqmm size. |
88 | One bell/buzzer point controlled by one push button with other switches on independent board with cable 1.5 Sqmm size. |
89 | One light point controlled by two 2- way switches, with cable 1.5 Sqmm size. |
90 | All as per item ser no-85 above here in before but one 3 pin socket outlet 5/15 Amps, independentboardwith cables 4.0 Sqmm size. |
91 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copperconductor drawn into including PVC casing & caping/fixed on wall/roof/ceiling etc of size not less than 20 mm diaincluding provision of 1.5Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- |
92 | One light point controlled by one switch. |
93 | One 3 pin socket outlet 5 Amps, independentboardwith cables 1.5 Sqmm size. |
94 | All as per item ser no-86 above here in before but one 3 pin socket outlet 5/15 Amps, independentboardwith cables 4.0 Sqmm size. |
95 | S&F in repair for switch piano, flush type single pole, one way 5 amp complete all as specified and as directed. |
96 | S&F in repair for bell push flush type, 5 Ampcomplete all as specified and as directed. |
97 | S&F in repair for switch piano, flush type single pole , two way 15 ampcomplete all as specified and as directed. |
98 | S&F in repair for switch socket combination 2 in 1, 3 pin, 5 Amp flush typecomplete all as specified and as directed. |
99 | S&Fin repair for switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universalcomplete all as specified and as directed. |
100 | S&Fin repair for ceiling rose three terminals/ PVC/ polycarbonate, isolated bodycomplete all as specified and as directed. |
101 | S&Fin repair for Lamp holder angular/batten type, PVC/ polycarbonate type with back plate complete all as specified and as directed. |
102 | S & Fin repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc and including taking down old all as specified and as directed . |
103 | M&L for sub main wiring for phase and neutral with PVC FRLS insulated unsheathed multi stranded along with earth wire FRLS PVC insulted copper conductor, single core cable in and including surface/concealed /PVC conduit of appropriate size as specified for the following sizes. Note:- : 1. Cutting chases for concealed wiring shall be measured and paid seperately. 2. Rates are including taking down old unserviceable. |
104 | 2x 1.5 sqmm and 1x 1.0 sqmm as earth wire |
105 | 2x2.5 sqmm and 1x1.5 sqmm as earth wire |
106 | 2x 4.0 sqmm and 1x 2.5 sqmm as earth wire |
107 | 2x 6.0 sqmm and 1x 4.0 sqmm as earth wire |
108 | 2x10 sqmm and 1x10 sqmm as earth wire |
109 | 2x16 sqmm and 1x16 sqmm as earth wire |
110 | Supply and fix high efficiency wall mounted LED batten type polycarbonate tubenot less than18W 4 ft LED light fitting and including taking down old unserviceable fittings complete all as specified and as directed. |
111 | Supply and fix high efficiency wall mountedLED batten type polycarbonate tube not less than10W 2 ft LED and including taking down old unserviceable fittings complete all as specified and as directed |
112 | Supply and fix Energy savingnot less than 25 Watts LED light fitting ,IP66 powder coated pressure die cast aluminium high power street light with heatresisant toughened glass with lens by providingGI pipe medium grade 25 mm dia 1.5 Mtrin length with suitable size MS Clamp two nos made out of 25x3 mm FI incl two coat of synthetic enamel paint over a coat of red oxide primer, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm from ceiling rose to fitting and including taking down old u/s damagedcomplete all as specified and as directed. |
113 | S&F sheet metal enclosurevertical TPN MCCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements complete all as specified and directed Note :-(i) Including taking down old u/s DB, MCCB and MCB"s (ii) MCCB and MCBs shall be measured and paid separately under the respective item of shedule. |
114 | All as per item ser no-99 above here in before but one vertical TPN MCCB DB 8 way double door . |
115 | All as per item ser no-99 above here in before but one vertical TPN MCCB DB 12 way double door . |
116 | S&F sheet metal enclosure Horizontal TPN MCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements all as specified and directed Note :-(i) Including taking down old u/s DB, MCB"s (ii) MCBs shall be measured and paid separately under the respective item of shedule. |
117 | All as per item ser no-102 above here in before but one Horizontal TPN MCB DB 6 way double door . |
118 | All as per item ser no-102 above here in before but one Horizontal TPN MCB DB 8 way double door . |
119 | All as per item ser no-102 above here in before but one Horizontal TPN MCB DB 12 way double door. |
120 | S&F sheet metal enclosure Vertical TPN MCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements complete all as specified and directed Note :-(i) Including taking down old u/s DB, MCB"s (ii) MCBs shall be measured and paid separately under the respective item of shedule. |
121 | All as per item ser no-106 above here in before but one Vertical TPN MCB DB 6 way double door . |
122 | All as per item ser no-106 above here in before but one Vertical TPN MCB DB 8 way double door . |
123 | All as per item ser no-106 above here in before but one Vertical TPN MCB DB 12 way double door . |
124 | S&F MCB,DB SPN 12 waydouble door DB with 200 amps rated copper bus barin SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule. |
125 | S&F MCB,DB SPN 08 waydouble door DB with 200 amps rated copper bus barin SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule. |
126 | S&F MCB,DB SPN 04 waydouble door DB with 200 amps rated copper bus barin SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule. |
127 | S&F MCB,DB SPN 02 way in SS enclosure type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule. |
128 | Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & fixed Magnetic setting type 250 Amps with breaking capacity 36 KA complete all as specified and as directed. Note : Including taking down old unserviceable. |
129 | Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting typetype 200 Amps with breaking capacity 36 KA complete all as specified and as directed. Note : Including taking down old unserviceable. |
130 | Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting typetype 150/160 Amps with breaking capacity 36 KA complete all as specified and as directed. Note : Including taking down old unserviceable. |
131 | Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting typetype 125 Amps with breaking capacity 10 KA complete all as specified and as directed. Note : Including taking down old unserviceable. |
132 | Supply and fix for MCCB 4 Pole, 415 V,adjustable Thermal & Fixed Magnetic setting typetype 100 Amps with breaking capacity 10 KA complete all as specified and as directed. Note : Including taking down old unserviceable. |
133 | Supply and fix for MCCB 4 Pole, 415 V,adjustable Thermal & Fixed Magnetic setting typetype 63 Amps with breaking capacity 10 KA complete all as specified and as directed. Note : Including taking down old unserviceable. |
134 | Supply and fix for MCB TP 415 V,25-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed. Note : Including taking down old unserviceable. |
135 | Supply and fix in repair for MCB TPN 415 V,40-100 Amps with breaking capacity 10KA C curve complete all as specified and as directed.Note : Including taking down old unserviceable. |
136 | Supply and fix for MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed. Note : Including taking down old unserviceable. |
137 | Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed. Note : Including taking down old unserviceable. |
138 | S& F forsheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete withoneSP MCB 20-32 Amps complete all as specified and as directed . |
139 | Material and labour for Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level , with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected with and incl GI earth wire 4mm dia including alternate 5 layersof charcoal, salt crystal and including 15 mm dia GI pipe light grade by means of nuts, bolts, washers and necessary earth work upto 7.5 mtr and connecting to test point, LT Switchgear etc as per site requirement including necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in elecrical plate No 3 of SSR Pt- I including testing on completion complete all as specified and as directed. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, reinforcement, removal of surplus soil , site clearance etc. |
140 | M&L for GI Pipe15 mm light grade galvanised, with all fitting laid in trenches complete all as specified and directed |
141 | M&L for cutting chases on brick walls concrete surfaces not exc10cm girth and making good in cement mortar (1:3) the existing surfaceafter carryiing out the concealed wiring including necessary finishes complete all as specified and as directed . |
142 | Supply and fix for MCCB 4 pole sheet metal enclosure with double door with spreader terminals, insulating phase barrier and hardware with neccesary arrangements complete all as specified and as directed. Notes: (i) Including taking down old unserviceable DB and MCCB. (ii) MCCB shall be measured and paid separately under the respective item of schedule. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy