Tender For Special Repair To Old Earthing/ Lightening Protection, Dbs, Lt Indoor Panels And Connected Accessories At Air Field Area And Replacement Of Electric Meter, Wall Fan, Water Cooler, Acs And Air Cooler Against Ber Under Ge (Mcte) Mhow, Indore-Madhya Pradesh

Military Engineer Services-MES has published Tender For Special Repair To Old Earthing/ Lightening Protection, Dbs, Lt Indoor Panels And Connected Accessories At Air Field Area And Replacement Of Electric Meter, Wall Fan, Water Cooler, Acs And Air Cooler Against Ber Under Ge (Mcte) Mhow. Submission Date for this Tender is 04-01-2024. Electrification Work Tenders in Indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41009396
Corrigendum : Tender For Special Repair To Old Earthing/ Lightening Protection, Dbs, Lt Indoor Panels And Connected Accessories At Air Field Area And Replacement Of Electric Meter, Wall Fan, Water Cooler, Acs And Air Cooler Against Ber Under Ge (Mcte) Mhow
Open Tender
Indian
Madhya Pradesh
Indore
04-01-2024

Tender Details

Special Repair To Old Earthing/ Lightening Protection, Dbs, Lt Indoor Panels And Connected Accessories At Air Field Area And Replacement Of Electric Meter, Wall Fan, Water Cooler, Acs And Air Cooler Against Ber Under Ge (Mcte) Mhow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Dec-2023 01Amdt43T Other 28-12-2023
2 28-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 56380.0 /-
Tender Value
INR 28.19 Lakhs /-

BOQ Items

Name of Work : Special Repair to Old Earthing/ Lightening Protection, DB"s, LT Indoor Panels and Connected Accessories at Air Field Area and Replacement of Electric Meter, Wall Fan, Water Cooler, ACs and Air Cooler Against BER under GE (MCTE) Mhow.
Sl. No. Item Description
1Taking down switch fuse/DB"S including MCCB/ MCB"s any type and any capacity complete all as directed.
2Taking down submain wiring any type and any size and making good disturbed surface and matching with existing colour complete all as directed.
3Taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and re fixing the same new indoor LT panel complete all as specified and as directed.
4Supply and Fix flush mounting factory made Vertical FP MCCBDB, IP-42 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for 100-125 Amps MCCB as incomer and SP/ SPN MCBs as out going 4 way complete all as specified and directed.
5S & F TPN DB with provision for MCB TPN as incomer and SP/ SPN MCBs as outgoing made of steel sheet phosphatised powder coated with bus bar, neutral link earth bar and DIN Rail having IP 42-IK 09 with metal door capacity 4/6 ways 415 V, connection with aluminium/ copper lugs including civil/ plastering work for make up good the disturbed surface matching with existing surface complete all asdirected.
6S&F MCCB 4-pole, 415 volts, in the existing panel/ location and connection with using aluminum lugs complete all as specified and directed for 150 Amps rating, 25 KA breaking capacity complete all as specified and as directed.
7S&F MCCB 3 Pole, 415 V, Adjustable type,160 Amps with breaking capacity 36 KA complete all as specified and directed.
8S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
9S & F for sheet metal enclosure MCB DB SPN 4/6 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
10S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
11Supply and fix MCB SPN 6 to 32 Amps 10 KA, "C" series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
12Supply and fix MCB SP 6 to 32 Amps 10 KA, "B" series including connection with suitable size aluminium / copper lugs complete all as specified and directed.
13Supply and fixing 415V 10KA "C" curve miniature circuit breaker (MCB) of 4 poles/ TPN and current carrying capacity 63 Amps in the DB complete with connection testing and commissioning capacity & connection complete.
14M&L for Sub main wiring in repairs with two runs of single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC insulated unsheathed 6.0 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wallall as specified and directed. Note:- Two runs of 6 sqmm cable, one run of 6.00 sqmm cable and one run of PVC conduit will be measured as one unit.
15M&L for Sub main wiring in repairs with two runs of single core FR PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed. Note:- Two runs of 4.00 sqmm cable, one run of 4.00 sqmm cable and one run of PVC conduit will be measured as one unit.
16Supply and fixing GI pipe light grade 50mm dia in short lengths, to walls/ poles/ pillers including cutting, chasing and fixing one endon walls/ pillers/ in ground for garden light fittings/ gate light complete all as specified and directed.
17Supply and lay XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade ofsize 16 sqmm 4 core, cross sectional area lay trenches/ wall/ poles/ ducts/pipes or through sleeve etc including connecting/ jointing with lugs and testing all as specified and directed.
18Supply and lay XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade ofsize 35 sqmm 3.5 core, cross sectional area lay trenches/ wall/ poles/ ducts/ pipes or through sleeve etc including connecting/ jointing with lugs and testing all as specified and directed.
19Supply and lay XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade ofsize 50 sqmm 3.5 core, cross sectional area lay trenches/ wall/ poles/ ducts/ pipes or through sleeve etc including connecting/ jointing with lugs and testing all as specified and directed.
20Excavation in trenches not exc. 1.5mwide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed by Engr-in-Charge.
21Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
22Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
23M&L for filling approved fine river sand in trenches as cablecushion to the full width of excavated trench, under and over cable complete all as specified and as directed. (Note:- Punned thickness of sand shall be measured)
24M&L for bricksslightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified and directed.
25M&L of earthing complete with GI steel earth plate electrode 60cm x 60cm x 6.0mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI strip 32 x 6mm by means of nuts, bolts checks nuts and washers made of GI earth wire protected by GI pipe 40mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 using 20mm graded aggregate, pre-cast RCC (1:2:4) type-B, over slab 30cm x 30cm x 10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No.3 of MES schedule Part-I and testing after completion.
26Supply assembly, erection, testing commissioning of indoor wall mounted panel frame size of 980mm x 1254mm x 325mm mounted cubical type factory made wall mounted LT panel board including 3 Phace electric meter 40 to 60 Amps suitable for 415V 3 phase 4 wire, 50HZ non-metalic kiosk single door with the required provision for 3 switch gears and control gears along with the approved make. Enclosed in a modular/ combinable thermoplastic polycarbonate panel enclosure which should be shock proof, IP65 (weather proof), rust proof, dust proof, water proof, corrosion proof having internally embadded gasket polyurethin material on the lid and cable entry knockouts on all sides or using cable entry flanges of size 300 x 300 x 170mm required of the LT panel including Two comparment for fixing of 01/02 Nos three phase meter and MCB and porviding glass view for reading of meter complete fabrication shall be painted as per specification. Wall mounted LT panel board shall be complete with all standard accessories factory made with OEM manufacturingcertificate & the type tests report as per CPRI with the following test- degree of protection of system, temperature rise limit, dielectric properties, short circuit with stand strength, effectiveness of protective circuit, clearance and creepage distance, mechanical operation accordance with IEC 60 439-1 including selector switches, phase indicating lamps control fuse unit, MV danger notice plate numbered/ lettered and with comprising the following. Make : HENSELCat Part No HEN MI LDB-2667-2023 or its equvalent in GE/ Rittal/ Delta
27(Item no 26 contd.) Incoming : MCCB 160 A, 4 pole, 25KA-1 No. including CTs (160A/5A, 5VACI.1-03Nos), Multifunction meter,Phase indicating lamps & control fuses terminal block 2/32- 06 Nos Bus Bar : Copper strip busbar rating 250A of size for Ph 12 x 10mm, N&E 12 x 5mm and short circuit capacity 30ka, with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 05 Nos Outgoing : Separate cubical chamber with a cable alley not less than 300mm width for installation/ connecting the following switch gear : (i) MCB, 40A DP Amps, 240 volts, ‘C’ curve, 10 KA - 20 Nos Note :-Terminal block 10 sqmm -40 Nos (ii)Fixing only 3 phase serviceable existing electric meter- 01 Nos
28Supply assembly, erection, testing commissioning of indoor wall mounted panelframe size of 1580mm x 1250mm x 320mm mounted cubical type factory made wall mounted LT panel board suitable for 415V 3 phase 4 wire, 50HZ non-metalic kiosk single door with the required provision for 3 switch gears and control gears along with the approved make. Enclosed in a modular/ combinable thermoplastic polycarbonate panel enclosure which should be shock proof, IP65 (weather proof), rust proof, dust proof, water proof, corrosion proof having internally embadded gasket polyurethin material on the lid and cable entry knockouts on all sides or using cable entry flanges of size 300 x 300 x 170mm required of the LT panel including four comparment for fixing of 10/12 Nos single phase meter and MCB and porviding glass view for reading of meter complete fabrication shall be painted as per specification. Wall mounted LT panel board shall be complete with all standard accessories factory made with OEM manufacturing certificate & the type tests report as per CPRI with the follwing test- degree of protection of system, temperature rise limit, dielectric properties, short circuit with stand strength, effectiveness of protective circuit, clearance and creepage distance, mechanical operation accordance with IEC 60 439-1 including selector switches, phase indicating lamps control fuse unit, MV danger notice plate numbered/ lettered and with comprising the following. Make : HENSEL Cat Part No HEN MI DB-2537-2023-2 or its equvalent in GE/ Rittal/ Delta
29(Item No 28 contd..) Incoming : MCCB 200 A, 4 pole, 25KA-1 No. including CTs, Digital Ammeter, ASS, Digital Volt meter, VSS, Phase indicating lamps & control fuses/ MCBs etc. Bus Bar : Copper strip busbar rating 250A of size for Ph 12 x 10mm, N&E 12 x 5mm and short circuit capacity 30ka, with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 05 Nos Outgoing : Separate cubical chamber with a cable alley not less than 300mm width for installation/ connecting the following switch gear : (i) MCB, 63A DP Amps, 240 volts, ‘C’ curve, 10 KA - 10/12 Nos (ii)MCB, 40A DP amps, 240 volts, ‘C’ curve, 10 KA - 01 Nos (iii)Fixing only single phase serviceable existing electric meter- 10/12 Nos (obtained from item No 3)
30Supply and fixin repair/ replacement of aluminium roof and down conductors of size 25 x 3mm thick fixed on insulators/ saddles of suitable size all as specified and as directed
31Supply and fix in repair/ replacement of Test terminal point block made of gun metal or phosporous bronze of size 75 x 75 x 25mm drilled and screwed including 3 nos, 8mm dia screws all as specified
32Supply and fix in repair/ replacement of air termination single pointed aluminium rod 12mm dia and 300mm long all as specifed and directed
33Taking down carefully copper/ aluminium sub-main wiring any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
34Taking down existing single/ three phase electric Meter any capacity of any capacity after disconnecting all necessary electrical connection and deposit to MES store yard of AGE E/M No-III Mhow complete all as specified and as directed.
35Taking down Exhaust/wall fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M No-III Mhow complete all as specified and as directed.
36Supply and fix single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH and writting the MES Number with synthetic enamel paint and taking down of old u/s gysher & deposit to MES store complete all as specied and as directed.
37Supply and fix three phase electronic meters temper proof LCD display with polycarbonate cover 415 V, 10- 60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH and writting the MES Number with synthetic enamel paint and taking down of old u/s gysher & deposit to MES store complete all as specied and as directed.
38Point wiring with 1.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FR LSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete,including one continuity earth wire ofPVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) FRLSH copper conductor connected to all fittings, common earth and connected to earth dolly including modular metal flush box, cover plate and cover frame of suitable size all fittings and accessoriesand making good disturbed surface of walls and floors etc. complete all as specified and directed for the following:-
39(a)One light/ fan/ bell point controlled by one switch complete all as specied and as directed
40Supply and fix Wall fan, AC single Phase. 230V of size 400mm sweep 1350RPM air delivery 65CMM 55W with, blades, and frame with necessary accessories and electrical connections from ceiling rose to wall fan teriminal includingwritting the MES Number with synthetic enamel paint complete all as specified and as directed. Make : Havells Cat Part No FHWSUSTWHT16,
41Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR. complete all as specified and as directed.
42Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity.40/80 Ltr.
43Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size). Plastic/ PVC Body. complete with all accessories.Make : Havells Cat Part No GHRACBJWX8 Model Celia-P.