Tender For Proposal Of Civil And Electrical Work With Cable Laying In The Proposed Kendriya Bhandar Near Blood Bank At Aiims Patna, patna-Bihar

All India Institute Of Medical Sciences-AIIMS has published Tender For Proposal Of Civil And Electrical Work With Cable Laying In The Proposed Kendriya Bhandar Near Blood Bank At Aiims Patna. Submission Date for this Tender is 27-12-2023. Electrical Maintenance Tenders in patna Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

41005513
Tender For Proposal Of Civil And Electrical Work With Cable Laying In The Proposed Kendriya Bhandar Near Blood Bank At Aiims Patna
Open Tender
Indian
Bihar
patna
27-12-2023

Tender Details

Proposal Of Civil And Electrical Work With Cable Laying In The Proposed Kendriya Bhandar Near Blood Bank At Aiims Patna

Key Value

Document Fees
INR 1500 /-
EMD
INR 14660.0 /-
Tender Value
INR 7.32 Lakhs /-

BOQ Items

Name of Work: Proposal of civil & electrical work with cable laying in the proposed Kendriya Bhandarnear blood bank at AIIMS Patna.
Sl. No. Item Description
1EARTH WORK Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete.
2CEMENT CONCRETE (CAST IN SITU)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
3MASONRY WORKBrick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
4WOOD AND P. V. C. WORK Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
5Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
6Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm
7Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
8Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
9FINISHING12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
10Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
11Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
12Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
13Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
14Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
15Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
16Dismantling and Demolishing Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
17ROAD WORKDry brick pitching half brick thick in drains including supply of bricksand preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
18ALUMINIUM WORKProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
19For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
20Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
21ELECTRICAL WORKWiringforlightpoint/fanpoint/exhaustfanpoint/callbellpoint with1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecableinsurface/recessedsteelconduit,with modular switch, modular plate, suitable GI box and earthing the pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor single core cable etc. as required. Group A
22Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
23Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
24Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
25Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizesofFRLS PVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire
26Supplyingandfixing20A,240V,SPNIndustrial typesocket outlet,with2poleandearth,metalenclosedplugtop alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required.
27Supplyingandfixingoffollowingwayssurface/recess mounting, verticaltype, 415 V, TPN MCB distribution board of sheetsteel,dustprotected,dulypowderpainted,inclusive of 200Atinnedcopperbusbar,commonneutrallink,earthbar, din bar for mounting MCBs (but without MCBs and incomer ) as required.(Note:VerticaltypeMCBTPDBisnormallyused where 3 phase outlets are required.)8 way (4 + 24), Double door
28Supplyingand fixing 5A to32A rating, 240/415V, 10kA, "C" curve,miniature circuitbreakersuitableforinductiveloadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Single pole (25 Amp)
29Supplyingand fixing 5A to32A rating, 240/415V, 10kA, "C" curve,miniature circuitbreakersuitableforinductiveloadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Single pole (10 Amp)
30Supplyingand fixing 5A to32A rating, 240/415V, 10kA, "C" curve,miniature circuitbreakersuitableforinductiveloadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Triple pole and neutral( 63 Amp)
31Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required.15/16 A switch
32Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required.15/16 A Modular socket outlet
33Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required. 5/6 A Switch
34Supplyingandfixingfollowingmodularswitch/socketonthe existing modular plate& switch boxincluding connections but excluding modular plate etc. as required. 10/6 A modular socket outlet
35Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
36Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
37Laying of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground includingexcavation,sandcushioning,protective coveringand refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
38LayingandfixingofonenumberPVCinsulatedandPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mmMS flat clamp)
39Supplying and making end termination with brass compression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 50 sq. mm (35mm)
40Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
413.5 c x 50 sqmm AL/ AR cable
4218 watt led batten light
43100 amp MCCB with Box
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail