Public Works Department-PWD has published Tender For Repair Upgradation Of Hvac System Installed In Pediatric Ot Block At Govt. Smgs Hospital Jammu. Submission Date for this Tender is 06-01-2024. AMC of Air Condition Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41002925
Corrigendum : Tender For Repair Upgradation Of Hvac System Installed In Pediatric Ot Block At Govt. Smgs Hospital Jammu
Open Tender
Indian
Jammu And Kashmir
jammu
06-01-2024

Tender Details

Tender For Repair Upgradation Of Hvac System Installed In Pediatric Ot Block At Govt. Smgs Hospital Jammu

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Dec-2023 EXTENSION1 Date 20-12-2023
2 21-Dec-2023 EXTENSiION1 Date 26-12-2023
3 27-Dec-2023 EXTENSION3 Date 01-01-2024
4 01-Jan-2024 EXTENSIiON4 Date 06-01-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 51000.0 /-
Tender Value
INR 25.06 Lakhs /-

BOQ Items

REPAIR/UPGRADATIONOFHVAC SYSTEM INSTALLED IN PEDIATRIC OT BLOCK AT GOVT. SMGS HOSPITAL, JAMMU
Sl. No. Item Description
1Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the requiredspecifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. 12 HP VRF Outdoor Unit (2 Working 01 standby)
2Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the requiredspecifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. Supply, installation, testing and commissioning of suitable refrigerant controller kit with remote control
3Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the requiredspecifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. Supply, installation, testing and commissioning ofDX COIL(6 ROW DEEP DX COIL WITH SUITABLE 3 Nos CIRCUIT)
4Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the requiredspecifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. All types of MS Works for Outdoor Units
5REFRIGERANT PIPING FOR VRF SYSTEM : SITC of Copper Referigant piping of the required sizes for all the units with refnets as per specs. The insulation shall be of 19mm thick Armaflex/ KFlex make through out the running length of Ref. piping. The piping shall be well supported at specific intervals with GI supports with insulated PUF saddles and Exposed pipes shall be installed on GI cable trays supported from wall / roof with anchor fasteners & C type ms angle. The pipe sizes are tentitive, the vendors have to consider as per their manufacturing standards.Consider PVC Sleeves inplace of PUF Saddles & GI Cable tray is considered only at Terrace exposed area 34.9 mm O.D. (insulation – 19 mm thick)
6REFRIGERANT PIPING FOR VRF SYSTEM : SITC of Copper Referigant piping of the required sizes for all the units with refnets as per specs. The insulation shall be of 19mm thick Armaflex/ KFlex make through out the running length of Ref. piping. The piping shall be well supported at specific intervals with GI supports with insulated PUF saddles and Exposed pipes shall be installed on GI cable trays supported from wall / roof with anchor fasteners & C type ms angle. The pipe sizes are tentitive, the vendors have to consider as per their manufacturing standards.Consider PVC Sleeves inplace of PUF Saddles & GI Cable tray is considered only at Terrace exposed area 15.9 mm O.D. (insulation – 19 mm thick)
7REFRIGERANT PIPING FOR VRF SYSTEM : SITC of Copper Referigant piping of the required sizes for all the units with refnets as per specs. The insulation shall be of 19mm thick Armaflex/ KFlex make through out the running length of Ref. piping. The piping shall be well supported at specific intervals with GI supports with insulated PUF saddles and Exposed pipes shall be installed on GI cable trays supported from wall / roof with anchor fasteners & C type ms angle. The pipe sizes are tentitive, the vendors have to consider as per their manufacturing standards.Consider PVC Sleeves inplace of PUF Saddles & GI Cable tray is considered only at Terrace exposed area 1 HP VRF Outdoor Unit
8SITC of Control cabling from Indoor to outdoor unit for all the units with the necessary fittings. The cabling shall be FRLS weather proof type as most of the cabling will have open exposure to atmosphere. The cabling shall be bundled properly and shall be neatly aligned with the Refrigerant piping. The cabling shall be well supported at specific intervals and & similar to refrigerant piping. (2 /4core x 1.5 Sq mm cu.cable )
9DUCTING & INSULATION WORKS Sheet Metal Ducting Supply, Installation, Testing & Commissioning & Handing over of the following:Rectangular Aluminium ducting – Factory Fabricated complete with splitter dampers, turning vanes, access doors, supports, air tight joints with dual insulation to avoid leakage, applied with sealant etc. as per site requirement. The duct supporting shall be as per SMACNA standards. 22gauge galvanized sheet(0-750mm)
10DUCTINSULATION SITC of Acoustic Insulation with 15 mm thick self adhesive open cell nitrile rubberas shown in the drawing ( Arma Cell / K/A/ Flex / Supreme make.)
11OLD EXISTING DUCT Dismantle, repair, Reinstalation , Testing & commissioning of old & existing Aluminiumduct
12SITC of Aluminium volume control dampers constructed with exturded aluminium construction with PVC gear and opposed blades complete with handles, bushes, linkages within the enclosure as per specs. (Shall be suitable for motorised actuation) Rate per Sq.Mt of area