| 1 | Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. |
| 2 | Nominal bore 150 mm dia. |
| 3 | Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. |
| 4 | Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date. |
| 5 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes |
| 6 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) |
| 7 | Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casing pipe for submersible cable external work 40 mm dia complete in all respect. |
| 8 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. |
| 9 | Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 10 | 150 mm dia |
| 11 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
| 12 | 32 mm dia |
| 13 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. |
| 14 | Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. |
| 15 | HDPE PE-80PN-6 |
| 16 | 75 mm dia |
| 17 | 90 mm dia |
| 18 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil |
| 19 | Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 20 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 21 | M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 22 | Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank and installation ofPV module on above structure as per approved design and drawings. Mountingstructure shall be suitably designto withstand wind velocity up to 150km/hr. The work shall be as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. This item does not include cost of OHSR/ MS fabricated structure with tank but includes cost of items required for installation of solar panels on top of the tank.Note: There shall be 5 year service warranty for solar panel and mounting structure. |
| 23 | Providing, installation, testing and commissioning of AC submerssible pump sets with inbuilt or individual solar pump controllerwith Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including cable from controller to motor pumps..Solar pumpshall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope . |
| 24 | Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switchbe provided. The cable shall be ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge. |
| 25 | 3.7 KW (5.0 HP) |
| 26 | Supply, installation, testing and commissioning of Remote monitoring unit on off grid solar controller for remote ON/OFF, parameter setting, monitoring and troubleshooting through mobile etc. complete. Web charges and data charges for 5 year during service warranty etc. complete in all respect as per technical specification and as per direction of Engineer. |
| 27 | Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On thePolyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item . The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). |
| 28 | The work includes P&F of Polyethylene Water Storage Tank(IS: 12701,ISI marked, indicating the BIS license No.) of approved make with cover. Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled .Note: There shall be 5 year service warranty for structure, tank, fittings etc. |
| 29 | 7500 Liter X 2 Nos. PE water tank, staging 12 meter. |
| 30 | Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. |
| 31 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 32 | P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. |
| 33 | Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. |