Tender For Repair To Flooring, Plastering, Periodical Services, Joinery Works And All Its Connected Works In Md Accn Under Age B/R Samba At Mil Stn Samba, samba-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair To Flooring, Plastering, Periodical Services, Joinery Works And All Its Connected Works In Md Accn Under Age B/R Samba At Mil Stn Samba. Submission Date for this Tender is 04-01-2024. Civil Work Tenders in samba Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40980788
Corrigendum : Tender For Repair To Flooring, Plastering, Periodical Services, Joinery Works And All Its Connected Works In Md Accn Under Age B/R Samba At Mil Stn Samba
Open Tender
Indian
Jammu And Kashmir
samba
04-01-2024

Tender Details

Tender For Repair To Flooring, Plastering, Periodical Services, Joinery Works And All Its Connected Works In Md Accn Under Age B/R Samba At Mil Stn Samba

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: REPAIR TO FLOORING, PLASTERING, PERIODICAL SERVICES, JOINERY WORKS AND ALL ITS CONNECTED WORKS IN MD ACCN UNDER AGE B/R SAMBA AT MIL STN SAMBA
Sl. No. Item Description
1Taking down cement plaster on brick/concrete surfaces or stone walls, ceiling, etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed . NOTE- Work will be carried out upto 2nd storey of bldgs also as per direction of Engr-in-charge including necessaryscaffolding required as per site conditions & no extra payment shall be made on this account.
2Rendering 10+5 mm thick on fair faces of brick or concrete surface walls in two layers, in cement mortar 1:4 , rendering is to be finished even and fair without using extra cement (up to 2nd storey with necessary scaffolding) complete all as specified and as directed by Engineer-in-charge.
3Rendering 10 mm thick cement plaster in cement mortar 1:6 on on brick /stone/concrete surfaces finished even and smooth without using extra cement (upto 2nd storey with necessary scaffolding), complete all as specified and directed.
4Rendering 5 mm thickon concrete surfaces in CM 1:3 on ceiling finished even and smooth without using extra cement , complete all as specified and directed .
5Dismanting of floor hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
6Non-skid Coloured ceramic tiles (1st quality) 7 to 8 mm thick (square / rectangular joint free) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a layer of mortor 15 mm thick in CM 1:6, complete all as specified and directed
7Non-skid Coloured ceramic tiles (1st quality) 7 to 8 mm thick (square / rectangular joint free) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a layer of mortor 15 mm thick in CM 1:6, complete all as specified and directed
8Non-skid Coloured ceramic tiles (1st quality) 7 to 8 mm thick (square / rectangular joint free) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in skirting etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed plaster 10 mm thick in CM 1:3, complete all as specified and directed
9Glazed coloured ceramic tiles (1st quality)joint freein vertical surfaces of wall of size 450x250x7mm/ 350x250x7 mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 10 mm thick rendering in CM 1:3on brick /concrete surfaces complete all as specified and directed .
10G.I. Tubing 40 mm dia heavy grade galvanised laid over floors as a spout pipe in sunken floors, complete all as specified and directed.
11Supply only of liquid water proofing compound ISI marked complete all as specified and directed
12Taking down cement plaster from chajjas or facias etc, incl. dismantling of damage conerete & repair the same with PCC 1:2:4 type B-0 (using 12.5mm crushed stone aggregate) on chajjas of any widthand applying 10mm thick cement plaster in CM 1:3 mixed with water proofing compound, finished even & smooth using extra cement, complete all as specified and as directed. Noe- Rate quoted shall be deemed to include for scaffolding/formwork for single/double storey building of height 8.0 mtr and making good the disturbed surfaces.(Water proofing compound shall be measured & paid separately)
13Demolition of reinforced cement concrete of any description ground to 2nd floors and removing the rubbish from the work site out side defence premises, complete all as specified and as directed.
14RCC M-15 (Nominal mix) 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roof slab, landing, balconies, canopies, deck slabs,shelves and the like etc complete all as specified and directed.
15Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
16Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, chajjjas, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) incl fair finished surface complete all as specified and directed.
17Use and waste form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roof and not exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar workexc. 10cm but n.exc. 20cm wide for fair finished surfaces of concrete, complete all as specified & directed
18Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing inlow lying area where directed and providing following :- (a) Preparing existing surface of floor and brushing neat cement slurry with 3.0 kg of cement per sqm (b)Rendering 15mm thick in Cement mortar (1:4)on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixingwater proofing compound @ 2% by weight of cement. (c)Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (d)After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface.
19Cound down description as per srl item no. 18.00 (e)Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slope from lowest line of sloping roof towards ridge. (f) Over the APP membrane, apply a two coat of solar reflective bituminious paint on top of membrane shall be provided as prescribed by manufecturer. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed by Engr-In-Charge. Photograph of ponding shall be produced at the time of RAR. (iii)Water proofing compound rate inclding qouted rate nothing paid extra.
20PCC 1:2:4 type B-0(using 12.5 mm graded stone crushed aggregate) as in roof padding coping, bed blocks etccomplete all as specified and directed.
21Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed .
22Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed .
23Brick work withsub class"B" burnt bricks straight or curved on planexc. 6 m mean radius built in CM 1:6 complete all as specified and directed .
24Brick work withsub class"B" burnt old size bricks straight or curved on planexc. 6 m mean radius bult in CM 1:6 but except bricks,complete all as specified and as directed.
25Brick work withsub class"B" burnt bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed .
26Rotational moulded polye- thylene water storage tanksof capacity 500 ltrs (cylindrical vertical with closed top) three layeres hoisted and fixed in position including all necessary connections all as specified in SSR Part I& including dismantling old unserviceable tank, complete all as specified and as directed.
27Rotational moulded polye- thylene water storage tanksof capacity 1000 ltrs (cylindrical vertical with closed top) three layeres hoisted and fixed in position including all necessary connections all as specified in SSR Part I& including dismantling old unserviceable tank, complete all as specified and as directed.
28Disconnecting existing tanks, cap exc 250 ltr and not exc 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as directed.
29Disconnecting existing tanks, cap exc 500 ltr and not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as directed.
30Cleaning and removing all scale and dirt etc, from water tanks exc. 250 and n.exc. 500 ltr capacityin any position and from mouths of circulating pipes etc and disinfection completely by making all the arrangements and writing date of cleaning on side of tanks also obtaining completion from user ,complete all as specified and directed.
31Cleaning and removing all scale and dirt etc, from water tanks exc. 500 and n.exc. 1000 ltr capacityin any position and from mouths of circulating pipes etc and disinfection completely by making all the arrangements and writing date of cleaning on side of tanks also obtaining completion from user ,complete all as specified and directed.
32Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 15 mm bore pipe including making connections, fixed in repair, complete all as specified and directed.
33Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm bore pipe including making connections, fixed in repair, complete all as specified and directed.
3420mm bore ball valves high pressure of PTMT with epoxy coated Aluminiumrod& high density plastic ball screwed for iron pipe and fixed in repair minimum weight 20 mm size-210 gms),complete all as specified and as directed.
35PVC water tank covers required for 500 ltr to 1000 ltr capacity, complete all as specified and directed.
36Taking down GI pipe 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
37G.I. pipe 15 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
38G.I. pipe 15 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors , but except pipe, complete all as specified and directed
39Taking down GI pipe 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
40G.I. pipe 20 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
41G.I. pipe 20 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors , but except pipe, complete all as specified and directed
42Repair to existing PVC pipe/CI pipe including making the joints water tight by using suitable material including cleaning if required and refixing of any dia, complete all as specified and directed. Note - Work to be carried out up to 2nd storey building in any condition of working place / area.
43Sealing of WC/floor traps joint and joints between rain water pipe and roof by using neat white cement paste or leak proof material and making the joint leak proof in case seepage is observed from WC/floor trap and joint of rain water pipe and roof slab, complete all as specified and directed.
44Taking down shutter of any description not exc. 1.0 sqmeach and removing to store.complete all as specified and as directed.
45Taking down shutter of any description exc 1.00 Sqm but not exc. 2.0 sqmeach and removing to store.complete all as specified and as directed.
46Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.5 square metre each including cutting holes for taking out hold fasts of dismantling brick work ( holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed.
47Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc 1.5 sqm but not exceeding 4 square metre each including cutting holes for taking out hold fasts of dismantling brick work ( holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed.
48Pressed steel frames 105mm x 60mm made out of size 1.25 mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hold fast,hinges, lock strike plate, etc and making good in CM 1:3 or cement concrete 1:2:4 Type B-1 including PCC 1:3:6 C-1 as in back filling to chowkhats .complete all as specified and directed .
49Pressed steel frames 125mm x 60mm made out of size 1.25 mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hold fast,hinges, lock strike plate, etc and making good in CM 1:3 or cement concrete 1:2:4 Type B-1 including PCC 1:3:6 C-1 as in back filling to chowkhats .complete all as specified and directed .
502nd class hard wood 35mm thick factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified anddirected .
512nd class hard wood Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified anddirected .
52Factory made solid PVC door frame of size 50x47mm made out of 5mm thick prelam PVC sheet with one or more rebate reinforced with MS square tube, fixed in opening as per specification & drawing No CEPZ/TD-378/11 sheet No 1/1, etc complete all as specified and directed.
53Factory made Solid panel PVC Door Shutter, 30mm thick (style),consisting of frame made of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles & rails with suitable PVC sheet beadding and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
54Double shutter Box type steel windows comprised of tubular frame and shutters made out of outer frame ERW tube "P" section (60x45x25)mm and shutters of ERW tube "P" section (50x35x20)mm openable shutters side hung including piston hinges with two nos of MS tower bolts 150 mm size on each shutter steel handle and stopper of "Z" section as specified completewith sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings / opening for cooler / AC where required. Steel windows will be double shutter external glazed and internal wire glazed complete all as specified and as per drawings no. CEPZ/TD-324/07 sheet 1/3 to 3/3. NOTE- The quoted rate against the above item shall also include- (i) 4 Nos MS steel lugs of 20x5 mm MS flat 20 cm long over all welded to frames (ii) PCC block for embedding lugs.
55Double shutter Box type steel ventilators comprised of tubular frame and shutters made out of outer frame ERW tube "P" section (60x45x25)mm and shutters of ERW tube "P" section (50x35x20)mm openable shutters side hung including piston hinges with two nos of MS tower bolts 150 mm size on each shutter steel handle and stopper of "Z" section as specified completewith sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings / opening for cooler / AC where required. Steel ventilators will be double shutter external glazed and internal wire glazed complete all as specified and as per drawings no. CEPZ/TD-324/07 sheet 1/3 to 3/3. NOTE- The quoted rate against the above item shall also include- (i) 4 Nos MS steel lugs of 20x5 mm MS flat 20 cm long over all welded to frames (ii) PCC block for embedding lugs.
56Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
57Hacking out old broken glass (any thickness,size quality or description) from any types of wooden/steel/alum (up to 4th storey) frames or stone concrete or brick surrounds glazed with putty or fixed with beads.complete all asspecified and as directed .
583.5 mm thick sheet glass ordinary quality glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding)
593.5 mm thick figured glass, pin head type and glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron /Steel /Wood /Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding), all as specified.
60Securing glass of any description in existing wooden and iron frames glazed with putty/beads including removing loose or decayed putty/beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work ,complete all asspecified and as directed . ( New length of frame reputtied shall be measured.
61Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples.complete all asspecified and as directed .
62Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples fixed in repair,complete all asspecified and as directed .
63Aluminium anodised, barrel tower boltssize 150 mm of extruded section and fixed complete all as specified and as directed
64Butt hinges of mild steel cold rolled medium weight of size 100mm complete all as specified and as directed
65Aluminium handles, fabricated type, anodised Size-100mm, anodised section and fixed complete all as specified.
66Aluminium alloy, anodised, sliding door bolt Size- 250 mmwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified.
67Brass face for CP/Brass Bib tap, Angle/Stop cock, Pillar cock, wall mixer, WHB mixer, etcfor 15 mm bore pipe,fixed in repair, complete all as specified and directed .
68PVC Knob or flushing handle for flushing cistern of capacity 10.0 litres , fixed in repair, complete all as specified and directed . (Sample as approved & kept in GE"s sample room)
69PVC float valve suitable for flushing cistern of capacity 10.0 litresfixed in repair, complete all as specified and directed . (Sample as approved & kept in GE"s sample room).
70PVC syphonic kit for flushing cistern of capacity 10.0 litres,fixed in repair, complete all as specified and directed . (Sample as approved & kept in GE"s sample room)
71PVC bend suitable for flushing cistern of capacity 10.0 litres,fixed in repair, complete all as specified and directed . (Sample as approved & kept in GE"s sample room).
72PVC syphon washer suitable for flushing cistern of capacity 10.0 litresfixed in repair, complete all as specified and directed . (Sample as approved & kept in GE"s sample room)
73Stainless steel lock grating plain/hole size 100 mmdiaincluding embeding in tiles with white cement, fixed in repair, complete all as specified and directed . Make:- Jainko, Essco, Parko.
74Preparation of new plastered or unplastered surfaces of ceilings andapplying three coats of white washingcomplete all as specified and as directed by Engineer-in-charge.
75Preparation of new plastered or unplastered surfaces of walls and applying three coats of white washingcomplete all as specified and as directed by Engineer-in-charge.
76Preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over and including a coat of wall care puttyand applying a coat of primer complete all as specified.
77Preparationof newplastered/ concrete surfaces of walls andapplying two coats of cement based paint over and includingone coat of primer (up to 2nd storey with necessary/scaffolding)complete all asspecified and directed by Engr-in-charge.
78Preparation of old decorated brick /concrete, plastered /un-plastered surfaces of ceilings, pillars, cornices etc (upto four storey bldgs) by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, rubbing with sand paperand applying one coat of lime white wash on the ceiling, pillars, cornices etc. complete all as specified and directed.
79Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of oil bound distemperincluding making good uneven surface/holes with Birla wall care putty coloured in same shade where ever required etc. complete all as specified and directed.
80Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etcby booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying one coat of cement base paint on walls, pillars, cornices etc (upto 2nd storey with necessary scaffolding complete all as specified and directed.
81Writing letters or figures (Block, Roman. Italic or Indian) n.exc 30cm high including obliterating old writing of any description n.exc 0.2 Sqm with paint to match existing work complete all as specified .
8250mm thick cement concrete 1:3:6, type C1, using 20mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:20 and surface finished even and smooth without using extra cement including making joint at 3m interval and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed.
83Demolition of cement concrete (unreinforced) of any description ground to 2nd floors and removing the rubbish from the work site out side defence premises, complete all as specified and as directed.
84Rendering 15 mm thick in CM 1:3 on concrete surfaces mixed with WPC compound, finished even and smooth using neeru finish to plastering as specified in sunken slab , complete all as specified and as directed. Note: WPC shall be measured and paid for separately
85Cleaning of dust removal to all loose existing sunken floor any material manually and with heat tark gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or equivalent make as approved by GE cold applied.Bituminous mortar and cold emulsion cum water proofing liquid of Shalikote-T-10 or equivalent make as approved by GE, createdSSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). Apply first coat of Tarfelt LM or equivalent make as approved by GE having alongwith 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm.Lay Geotex of 45 GSM/fiber mesh simultaneously and paste it properly with overlap of 50mm.
86Discription count down as per srl item no 85.00 Allowed of first coat to dry for 10 to 12 hrs. Apply 2nd coat on cured first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller.Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm/Sqm. Ensure final curing time of 36 hrs before allowing/carrying out any further work. Conduct ponding test after minimum 7 days applying 2 coats of U V Resistand Elastomeric Exterior Axcrylic weather resistant water proof coating of Shalicryl - 215 or eauivalent make as approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D-6083, for U V protection of bituminous Elastomeric Acrylic emulsified liquid membrance of Tarfelt LM or equivalent make as approved by GE to give long life and prevent its deterioration from sunlight. Note :Application of water proofing treatment will be done by authorised applicator only.
87Plain Cement concrete 1:5:10type E-2 (using 40 mm graded stone aggregate) as in sunken filling and mass concrete, complete all as specified and directed
8815mm bore CP Bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair, complete all as specified. Make:- Jainko ,Essco, Parko
8915mm bore angle valve with wall flange , cast copper alloy, chromium plated fancy type screwedfor 15 mm iron pipe, fixed in repair,complete all as specified. Make:- Jainko,Essco, Parko.
90PVC valveless,syphonic action type, flushing cistern, low level,white with inlet, ball valve, float and handle including brackets, PVC 32 mm "L" bend of capacity 10.0 litres and making good to dismantled/damaged floor/surfaces, fixing in repair, complete all as specified and as directed by Engineer-in-charge. Make:- Cera, Cat No- B1010109 ( CONGO) or equivalent model in Jaquar/ Hindware.
91WC Orissa pattern white with integral foot rest580x 440 mm including L bend, &PCC bedding in 1:2:4 and making good disturbed floor connecting to trap and flush pipe(Rate of including in taking out and removal of old WC seat unhygienic condition),fixed in repair, complete all as specified and directed . Make:- Cera, Cat Part No-S3010102 (CALINA) or equivalent model in Jaquar/ Hindware.
92Braking the termite mounds, making holes with crow bars and pouring antitermite chemical emulsion at the rate of 4 ltr per cubic mtr of mound, complete all as specified and directed.
93Providing and injecting chemical emulsion for post constructional antitermite tretment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 ltr per sqm of the vertical surface of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and directed.
94At points of contact of wood work by chemical emulsion ( in oil or kerosene based soluation) @ 0.5 ltr / hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same, complete all as specified and directed.
95Complete removal of existing treatment including washing, rubbing down with sand paper and stopping of painted surfaces including preparation of old plastered surfaces of walls, chajjas, facia, face of coloumn, beams etc. and applying two coats of weather proof exterior emulsion (Apex) making good uneven surfaces/ holes with 2 mm thick layer of birla wall care putty coloured in same shade where ever required etc. (upto 2nd storey with necessary scaffolding), complete all as specified and directed.
96Preparation of old plastered surfaces of walls, chajjas, facia, face of coloumn, beams etc. and applying one coats of weather proof exterior emulsion (Apex) making good uneven surfaces/ holes with birla wall care putty coloured in same shade where ever required etc. (upto 2nd storey with necessary scaffolding), complete all as specified and directed.
97Providing and applying waterproofing tretment to slab area with Asian paints smart care damp block 2k @ 1.5 kg/sqm, damp block 2k is a two component elastomeric cementitious coating conforming to ASTM D 412 & ASTM D 4548.5 standards including all necessary surface preparation etc. complete as per manufactures specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1.0 mm. The coating shall have a 100% elongation and crack bridging upto 1.2 mm as per ASTM D 4548.5.complete all as specified and directed. Make - BASF / ASIAN PAINTS / SIKA/ FOSROC Note - The work will be executed by the authorised company backed applicator.
98Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 1:2:4 as required superficial area n.exc. 150 sq.cm, complete all as specified and directed.
99Dismantling PVC/Cement/ CI pipes 50 to 110 mm dia including all fittings like bend, branch, pieces, connectors, heel rest bend etc and removing from site , complete all as directed.
100UPVC (SWR) type B pipes 110 mm bore single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and as directed by Engineer-in-charge.
101UPVC (SWR) type B pipes 110 mm bore single socketed, in any length with rubber ringjoints fixedto walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and as directed by Engineer-in-charge.
102UPVC (SWR)type B pipes 75 mm bore single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and as directed by Engineer-in-charge.
103UPVC(SWR)type B pipes 75 mm bore single socketed, in any length with rubber ringjoints fixedto walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center , complete all as specified and as directed by Engineer-in-charge.
104UPVC (SWR) , bends for75 mm bore , complete all as specified and as directed by Engineer-in-charge.
105UPVC (SWR) , bends with access doorfor75 mm bore , complete all as specified and as directed by Engineer-in-charge.
106UPVC(SWR) , bendsfor110 mm borecomplete all as specified and as directed by Engineer-in-charge.
107UPVC(SWR) , bends with access door, for110 mm borecomplete all as specified and as directed by Engineer-in-charge.
108UPVC branch piece, single (single "Y") with access door for 75 mm bore complete all as specified and directed.
109UPVC branch piece, single (single "Y") with access door for 110 mm bore complete all as specified and directed.
110UPVC(SWR), junction single,(single "T") with access door equal or unequal for 75 mm bore , complete all as specified and as directed by Engineer-in-charge.
111UPVC(SWR), junction single,(single "T") with access door equal or unequal for 110 mm bore , complete all as specified and as directed by Engineer-in-charge.
112UPVC (SWR) , reducers 110 mm dia complete all as specified.
113UPVC (SWR) vent cowl 75 mm dia complete all as specified.
114UPVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) fixed in repair, complete all as specified and directed.
115Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail