Tender For Repair Maint And Lt Capacitor Banks, Servo Stabilizers, Lt Cables, Route Indicator, Lt Switchgears, Feeder Pillar Boxes, Cable Tray And Air Circuit Breakers At Old Cantt Under Ge(North) Patiala, patiala-Punjab

Military Engineer Services-MES has published Tender For Repair Maint And Lt Capacitor Banks, Servo Stabilizers, Lt Cables, Route Indicator, Lt Switchgears, Feeder Pillar Boxes, Cable Tray And Air Circuit Breakers At Old Cantt Under Ge(North) Patiala. Submission Date for this Tender is 28-12-2023. Circuit Breakers Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

40979834
Corrigendum : Tender For Repair Maint And Lt Capacitor Banks, Servo Stabilizers, Lt Cables, Route Indicator, Lt Switchgears, Feeder Pillar Boxes, Cable Tray And Air Circuit Breakers At Old Cantt Under Ge(North) Patiala
Open Tender
Indian
Punjab
patiala
28-12-2023

Tender Details

Repair Maint And Lt Capacitor Banks, Servo Stabilizers, Lt Cables, Route Indicator, Lt Switchgears, Feeder Pillar Boxes, Cable Tray And Air Circuit Breakers At Old Cantt Under Ge ( North ) Patiala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Dec-2023 CORRIGENDUM NO 1 BOQ 28-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR MAINT AND LT CAPACITOR BANKS, SERVO STABILIZERS, LT CABLES, ROUTE INDICATOR, LT SWITCHGEARS, FEEDER PILLAR BOXES, CABLE TRAY AND AIR CIRCUIT BREAKERS AT OLD CANTT UNDER GE(NORTH) PATIALA
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed.
2Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
3Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at a level not exceeding1.5 mtr above the starting point complete all as specified and directed.
4M & L for Clean dry sand laid in trenches/ducts for bedding andcushioning to cable, including spreading and leveling complete all as specified and directed. Note:-(i) Consolidated/punned sand shall be considered for purpose of payment.(ii) Sand shall be same as specified for plastering work.
5M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection complete all as specified and directed.
6Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade laid in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
7All as per item No. 06 here-in before but for cable of size 4 core 16 sqmm.
8All as per item No. 06 here-in before but for cable of size 3.5 core 50 sqmm.
9All as per item No. 06 here-in before but cable of size 3.5 core 185 sqmm.
10Laying only, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade laid in duct / trenches for small length for extension/replacement of the defective cable or existing temporary cables laid in air ofany size and specification , whatever held with Div stock GE (North) Patiala,including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :- (i)UG cable will be issued under Sch `B" free for fixing/laying or laid in trenches at site , also temporary connections existing will be laid in trenches as directed by AGE E/M (N) Patiala. (ii)Old retrived cable should be take over into salvage register against Sch "B". (iii) Excavation, Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately
11M&L for dismantling insulators any type, any size from LT poles complete all as specified and directed by Engineer-in-charge.
12Supply and fixing in replacement of loop type insulators porcelain shackle type vitreous white, brown or green of size 65x90mm overall dimension and 20mm clearence hole complete all as specified and directed.
13M&L for replacement of shackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 100mm height and 115 mm dia including galvanized mild steel straps of section 31 x 5 mm size ,14 mm dia bolt nut and washers complete all as specified and directed .
14M & L for Stay assembly with 20 mm dia stay rod in replacement complete with accessories as shown in electrical plate No. 1 all as specified and directed. Note:- (loop type insulator, stay clamps, excavation and concrete measured separately
15M&L for Dismantling of ACSR conductors after unbinding from insulatorsNote:- (i)Total no of conductors in over head line to be taken down shall comprise a maximum of three phase, one neutral ,one street light/security light for measurement length of each conductor shall be takenseparately complete all as specified and directed.
16Supply and fixof ACSR conductor of size as per site requirementto bedrawn straighthorizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified and directed,
17M&L for Painting to existing PCCpole of any typewith Black and yellow synthetic enamelpaint overexisting paint up to 1.5 m height from bottom alternatively strips of 30 cm each including painting of ,clamps, nut, bolts with aluminum paint including providingpole number with white enamel paint and 100 mm dia(round)background ofblue enamel paint at sitecomplete all asdirected by Engr-in-Charge.
18M&L for painting to existing steel tubular pole of any type complete withtwo coat of aluminium synthetic enamel paint from bottom to top of the pole inculding black and yellow paint upto 1.5 Mtr height from bottom alternativelystrips of30 cm eachincluding providingpole number with white enamel paint and 100 mm dia(round)background ofblue enamel paint at sitecomplete all asdirected by Engr-in-Charge.
19M&L Paint to existing LT panel board of any type complete withtwo coat of weather proof synthetic enamel spraypaint over a coat of red oxide primer after preperation of the surface complete all as specified and directed.
20M&L for stretching and tightning of existing ACSR conductor any size on LT pole 9 mtr long all as specified (one span consists of 5 run of conductor and one run of GI wire) includind replacement of J hooks complete all as specified and directed.
21M&L for replacement of existing worn out /over heated/multi-jointed ACSR jumpers of LT over head lines with and inclXLPE/PVCinsulated 1100 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow, blue and black for neutralincl winding with ACSR conductors with suitable size aluminium binding wire complete all as specified and directed . (Length of one jumper not exceeding more than 2.0 mtrs) .
22M&L for replacement of existing worn out /over heated/multi-jointed ACSR jumpers of LT over head lines with and inclXLPE/PVCinsulated 1100 volts multi stranded aluminium conductor single core cable of size 240 sqmm as per colour code in sequence Red ,yellow, blue and black for neutralincl winding with ACSR conductors with suitable size aluminium binding wire complete all as specified and directed .(Length of one jumper not exceeding more than 2.0 mtrs) .
23S&F inreplacement ofMCCB with adjustable thermal and fixed magentic setting typeRelease Range 63 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 27 KA complete all as specified and directed.
24S&F inreplacement ofMCCB with adjustable thermal and adjustable magentic setting typeRelease Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.
25Supply and fix dangernotice plate of 1.6 mm thick mild steel sheet, vitreous enamelledwhite ,with letters and conventionalskull and bone in postal red color and fixed with flat iron clamps, nuts, bolts , and washersof size 200mmx 150 mm for LT Note :(Note:-the printingshall be hand written only stancils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width .)
26Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as directed by Engineer-in- Charge
27M & L for earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm burieddirectly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GIstrip of size 32X6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work, GI pipe light grade 25mm/40 mm bore for protection of GI wire /strip fromearth electrode to and incl thesupplying and lying charcoaldust, common salt,PCC 1:3:6 type CI (using20 mm graded crushedstone aggregate)as inchamber and MS angle iron frame 40 x 40 x 3mm and RCCcover 40 mm thick 1:2:4 type B1 (using 20 mm gradedcrushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c bothwayswith MS handle 12 mm dia, PGIfunnel andwire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed
28M &lfor PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
29M&L for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in mass concrete in foundations etc complete all as specified and directed .
30Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including necessary form work and finishing the surface fair and even without using extra cement complete all as specified and directed.
31M&L cable jointing kit for 1100 Volt grade cableheat shrink type joint complete with jointing meterial and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm complete all as specified and directed..
32M&L cable jointing kit for 1100 Volt grade cable for indoor type heat shrink type joint complete with jointing material and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400sqmm complete all as specified and directed..
33Supply and laying,galvanised steel tubing light grade 50 mm diacomplete with all fittingfor cable protection along with pole across road etc. Complete all as specified and directed by Engr-in-Charge.
34All as per item Ser No 33 above but size of pipe 80 mm dia
35Supply installation, testing and commissioning in replacement of Main LT Feeder panelboard outdoor type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory fabricated CPRI approvedpowder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 60X60X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy,inner compartment made out of 2.15 mm thick CRCA sheet duly compartmentalized for each MCCB"s as incoming and outgoing with MCCB"s,lockable arrangement with aluminium bus bar three phase and neutral of capacity of 1000 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all control PVC wires shall be with 2.5 sq mmmultistrand copper conductor and shall be properly bunched, tied, ferruled for proper indication , fixed on PCC foundation complete.Note:- (i)LT panel maker shall comply the IS/IEC-61439 (Part-1) : 2011 &IS/IEC-61439 (Part-2) : 2011 (ii)PCC shall be measured and paid separately. INCOMING:- (a) ACB 800 Amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 50 KA-01 Nos (Ultimate breaking capacity ICs - Icu = 100 %) OUT GOING:- (a) MCCB 250 A,415V 3 Pole,36 KA---- 6 No (b)MCCB 100 A,415V 4Pole,16KA----1 Nos (c) MCCB 40A,415V 4 Pole, 16 KA---- 1 Nos (d) Digital type Volt meter 0-500 Volts square typewith selector switch- 01 No. (e) CT of suitable size (f) Digital type Ammeter 0-400 Amps square typewith selector switch- 01 No. (g)Wiring complete with copper wire of suitable size (h) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set. (i) Cable glands brass of suitable size for cable. For - Pocket 5 New Map ,Pocket 8/9 Old Map Sub Stn No. 1 & Pocket 8/9 Old Map Sub Stn No. 2
36Supply installation, testing and commissioning of LT Feeder panelboard , outdoor type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory fabricatedCPRI approved powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy,inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB"s as incoming and outgoing with MCCB"s,lockable arrangement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yellow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all control PVC wires shall be with 2.5 sq mmmultistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:-PCC shall be measured and paid separately. INCOMING:- (a) MCCB 200 Amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 36 KA-01 Nos (Ultimate breaking capacity ICs -Icu = 100 %). OUT GOING:- (a)MCCB 32 Amps, 4 pole 415 Volts, 16 KA-04 Nos (Ultimate breaking capacity ICu - 100 %) . (C) Digital type Volt meter 0-500 Volts square typewith selector switch- 01 No. (d) CT of suitable size (e) Digital type Ammeter 0-400 Amps square typewith selector switch- 01 No. (f)Wiring complete with copper wire of suitable size (g) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set. (h) Cable glands brass of suitable size for cable. For Security Light Panel Old Map NOTE : Make of MCCB for item no 35 and 36 : Havells , L&T ,Indo Asian
37Supply and fixing street light sintex box of size 300 mm x 200 mm x 105 mm, made out of FRP sheet with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Amps MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed.
38Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm boreGItubing and cable etc complete all as specified and directed.
39Supply and fix including replacement of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 20 KVAR, including commissioning and testing complete. All as specified and as directed.
40Supply and fix including replacement of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 60 KVAR, including commissioning and testing complete. All as specified and as directed.
41Replacement of unserviceable spares of Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 470 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and ofcapacity 75 KVA. Complete all as specified and as directed. Note:- (a)All spares shall be measured and paid separately under respective items of schedule here-in-after. (b)Contractor will liable to repair of voltage stabilizer and replacement of unserviceable spares from authorized dealer/workshop and shipping to this office after repair/replacement.
42Three phase card
4375 KVA Coil
4410 KG motor
45Trigger 24 Volt
46Replacement of unserviceable spares of Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 470 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and ofcapacity 30 KVA. Complete all as specified and as directed. Note:- (a)All spares shall be measured and paid separately under respective items of schedule here-in-after. (b)Contractor will liable to repair of voltage stabilizer and replacement of unserviceable spares from authorized dealer/workshop and shipping to this office after repair/replacement.
47Single phase card
4830 KVA Coil
493 KG motor
50Trigger 12 Volt
51M&L Galvanised stay strand of size 7/4 sqmm complete all as specified and directed.
52S&F MCCB , TPN, 415 Volt , 63 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed. (Note: MCCB should be B or C curve as directed by engineer in charge)
53S&F MCCB , TPN, 415 Volt , 100amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed. (Note: MCCB should be B or C curve as directed by engineer in charge)
54S&F in replacement of MCB isolator TP 100 AMPS240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB complete all as specified and directed. .
55MCB, TRIPLE pole & neutral (TPN) 10 KA 415 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
56Supply and fixing for sub main wiring two single core PVC insulatedand unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit 25 mm dia with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiringcomplete all as directed.Note1: Chasing, cementing work and pvc conduit shall be deemed to included in quoted rates.Note2: Tworuns of 10 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathedcopper conductor as earth wire, 25 mm dia conduitand conduit accessories shall be measured as one length.
57Supply and fixing for sub main wiring Four single core PVC insulatedand unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmmtwo single core PVC copper conductor cable as in earth wire system ,including taking out old wiringcomplete all as directed. Note1 : four runs of 10 sqmm cable alongwith two run of 6 Sqmm PVC insulated unsheathedcopper conductor as earth wire shall be measured as one length.
58M&L for galvanized steel tubing 40 mmlight garde (ISI marked) inreplacement of old damaged steel GI pipe for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
59M&L in replacement of old/damagedearthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
60M&L in replacement of old u/s highly efficient LED building/security light 25 watt luminaries new generation energy saving & environment friendlywith lens made of pressure die cast aluminium alloyhousing LM24 for gear and exturded alluminium lamp housing & enclouser with toughened glass with IP-66 of protection class,with high power LEDs as light source having luminous efficiency should be > 80Lm/w with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) .It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -40°C to 50 °Cand humidity level 10% to 90% including connection with PVC unsheathed wirealuminium conductor 3 x 1.5sqmm fitted on pole/building with GI bracket of suitable size complete all as specified and directed Engr-in-Charge.
61Supply, Install , testing and commissioning of Wall Mounted LT panel in replacement of old damaged wall mounted LT panel CPRI approved of suitable size for 3 Phase 415 Volts indoor type made out 2 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted onangle iron 50x50x6 mm frame of the panel board , fitted on wall by proper cementing work, thimbling and cable entry boxes with cable gland. and thecopper bus bar should be 1.5 time from themain incoming complete all as specified and directed.NOTE:-All MCCB"s used are thermal magnetic overload and short-circuit protection class with adjustable thermal and magnetic levels.Incoming: (i) MCCB 4 pole 250 amps 25 KA- 01 No outgoing: (i) MCCB 4 POLE 100 amps 25 KA- 04No (outgoing to V TPN DB for ligght/fan/socket point) (ii) Ampere meter (digital type) 0-100 amps with selector switch-01 No (iii) Volt meter (digital type) 0-500 volts with selector switch - 01 No Indicator lamp RYB (3 Nos) - 01 Set
62S & F INDUSTRIAL HIGH BAYLED light of capacity 120 W ,The LED make must be of minimum 100 lumen/watt .The driver must be power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection. the luminaire must have secondary optics with perfectly matched lens for better light control with CMRI approved correleted color temperature(CCT) of Emitting light 5700 K with with die cast aluminium housing with heat resistant toughened glass IP 66 protection comlete with control gear box and all accessories require to fix the light on wall/structure/pole like clamps nus, bolts et cwith suitable size and including connecting up with twin core twisted flexible copper conductor cable 1.5x2 sqmmwith proper clamps. complete all as specified and directed by Engr in Charge.
63Supply and fixincl taking down 10 watt LED bollard/garden light fitting Fitted on suitable size pcc block with nut bolts and in stainless steel housing with clear acrylic cover in top section with IP 65 protection class ,connection with 1.5 sqmm 3 core copper cable upto 1.5 RM including making suitable PCCfoundation and all electrical connection complete all as specified and directed by Engr in Charge.
64S&F PVC insulated copper conductor 3 core 1.5sqmm passing throughflexible PVC conduit andfixed with clamp. complete all as specified and directed. NOTE:-cable and flexible PVC conduit both shall be deemed to included in quoted rates.
65Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade laid in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 6 sqmm 2.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
66Supply and fixincl taking down outdoor decorative LEDPost top lantern with spun aluminium die cast Housing cum heat sink PMMA diffuser in IP65fitted LED light of capacity 40 watt. complete all as specified and directed.
67Supply and fixincl taking down outdoor decorative LEDPost top lantern with spun aluminium die cast Housing cum heat sink PMMA diffuser in IP65fitted LED light of capacity 20 watt. complete all as specified and directed.
68M&L for replacement of old damaged PVC junction Box of size upto 6"x6"x2.5 for single phase connection outdoor box shall be fixed on wall/pole with suitable size nuts and boltsto be included in quoted cost complete all as specified and directed.NOTE:-To fix the junction box required disconnecting and refixing of connections to be included in quoted rate.