}

Tender For E And M Work Of Construction Of Prefabricated Structure In 3Rd Floor Pod 1E, indore-Madhya Pradesh

Indian Institute Of Technology-IITB has published Tender For E And M Work Of Construction Of Prefabricated Structure In 3Rd Floor Pod 1E. Submission Date for this Tender is 13-12-2023. Kitchen Equipment Tenders in indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40977408
Tender For E And M Work Of Construction Of Prefabricated Structure In 3Rd Floor Pod 1E
Open Tender
Indian
Madhya Pradesh
indore
13-12-2023

Tender Details

Tender For E And M Work Of Construction Of Prefabricated Structure In 3Rd Floor Pod 1E; 1 Supply, Installation, Balancing And Commissioning Of Fabricated At Site Gss Sheet Metal Rectangular / Round Ducting Complete With Neoprene Rubber Gaskets, Elbows, Splitter Dampers, Vanes, Hangers, Supports Etc. As Per Approved Drawings And Specifications Of Following Sheet Thickness Complete As Required. 2 Thickness 0.63 Mm Sheet 3 Thickness 0.80 Mm Sheet 4 Supply, Installation, Testing And Commissioning Of Gi Volume Control Duct Damper Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc, As Per Specifications. 5 Supplying & Fixing Of Powder Coated Extruded Aluminium Return Air Grills With Louvers But Without Volume Control Dampers Complete As Required. 6 Supplying, Fixing Testing Commissioning Of Supply Air Diffusers Of Powder Coated Aluminium With Aluminium Volume Control Dampers With Anti-Smudge Ring & Removable Core. 7 Supplying And Fixing Of Following Thickness Duly Laminated Aluminum Foil Of Mat Finish Closed Cell Nitrile Rubber ( Class O ) Insulation On Existing Duct After Applying Suitable Adhesive For Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide, And 3 Mm Thick Self-Adhesive Nitrile Rubber Tape Insulation Complete As Per Specifications And As Required. 8 19Mm 9 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet Plate, Suitable Gl Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 10 Group C 11 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 12 32 Mm 13 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 14 3 X 4 Sq. Mm 15 Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 16 3 Module ( 100Mmx75mm ) 17 6 Module ( 200Mmx75mm ) 18 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 19 5 / 6 Amps Switch 20 15 / 16 Amp Switch 21 3 Pin 5 / 6 Amp Socket Outlet 22 6 Pin 15 / 16 Amp Socket Outlet 23 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 24 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 25 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 26 125 A.36Ka.Fpmccb 27 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 28 6 Way ( 4 + 18 ) , Double Door 29 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) With Ppi Kit. 30 4 Way ( 4 + 12 ) , Double Door 31 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 32 Single Pole 33 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required 34 63 A 35 Supplying And Fixing Following Rating, Four Pole, 415 V, 63 Amp Mcb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 36 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 37 Supplying And Installing Following Size Of Perforated Hot Dipped Galvanized Iron Cable Tray ( Galvanization Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.L. Suspenders Including G.L. Bolts & Nuts, Etc. As Required. 38 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 39 Supplying And Installing Following Size Of Perforated Hot Dipped Galvanized Iron Cable Tray Bends ( Galvanization Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.L. Suspenders Including G.L. Bolts & Nuts, Etc. As Required. 40 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 41 Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee ( Galvanization Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.L. Suspenders Including G.L. Bolts & Nuts, Etc. As Required. 42 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 43 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 44 3½ X 70 Sq. Mm ( 38Mm ) 45 Supplying And Layingof One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. 46 3 ½ Cx 70 Sq Mm Aluminium Armoured 47 Supply, Installation, Testing & Commissioning Of 36W Recessed Mounted Led Fixture600mm X 600Mm ( 2X2 ) Recessed Mounted Led Fixture With Crca Powder Coated Housing High Efficiency Pmma Diffuser Complete With Electronic Driver, P.F>0.9, Thd<10%, Rated Life Of L-70 @ 40, 000 Having Minimum Lumens Output Of 3600 Lumens & Efficacy Better Than 100 Lumens / Watt With Cri > 80 Including Making Suitable Arrangement As Per Recommendations Of Manufacturer For Fixing On Surface & Connection With 3 X 1.5 Sq.Mm Pvc Insulated Flame Retardant- Lszh Copper Conductor Cable Etc, As Required. 48 Supply, Installation, Testing & Commissioning Of 18 / 20 W Led Tube Light Fixture.

Key Value

Document Fees
Refer document
EMD
INR 35000.0 /-
Tender Value
INR 17.10 Lakhs /-

BOQ Items

Name of Work: E&M work of construction of prefabricated structure in 3rd floor POD 1E
Sl. No. Item Description
1Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
2Thickness 0.63 mm sheet
3Thickness 0.80 mm sheet
4Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
5Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
6Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti-smudge ring & removable core.
7Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide, and 3 mm thick self-adhesive nitrile rubber tape insulation complete as per specifications and as required.
819mm
9Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class steel conduit, with piano type switch, Phenolic laminated sheet plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
10Group C
11Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required.
1232 mm
13Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
143 x 4 sq. mm
15Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
163 Module (100mmX75mm)
176 Module (200mmX75mm)
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
195/6 amps switch
2015/16 amp switch
213 pin 5/6 amp socket outlet
226 pin 15/16 amp socket outlet
23Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
24Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
25Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
26125 A.36KA.FPMCCB
27Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
286 way (4 + 18), Double door
29Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) with PPI kit.
304 way (4 + 12), Double door
31Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32Single pole
33Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
3463 A
35Supplying and fixing following rating, four pole, 415 V, 63 Amp MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
36Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
37Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.
38150 mm width X 50 mm depth X 1.6 mm thickness
39Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (Galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.
40150 mm width X 50 mm depth X 1.6 mm thickness
41Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (Galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.
42150 mm width X 50 mm depth X 1.6 mm thickness
43Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
443½ X 70 sq. mm (38mm)
45Supplying and layingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
463 ½ CX 70 sq mm Aluminium Armoured
47Supply, installation, Testing & Commissioning of 36W recessed mounted LED fixture600mm x 600mm (2x2) recessed mounted LED fixture with CRCA powder coated housing high efficiency PMMA diffuser complete with electronic driver, P.F>0.9, THD<10%, rated life of L-70 @ 40,000 having minimum lumens output of 3600 lumens & efficacy better than 100 lumens/watt with CRI > 80 including making suitable arrangement as per recommendations of manufacturer for fixing on surface & connection with 3 x 1.5 sq.mm PVC insulated Flame Retardant- LSZH copper conductor cable etc, as required.
48Supply, Installation, Testing & Commissioning of 18/20 W LED Tube Light fixture.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail