Tender For Annual Repair And Maintenance Work Related To Water Supply System In Pragati Nagar Colony Of Dipka Area.
Tender Value
77.95 Lakhs
Estimated cost
Bid Submission
25 Dec 2023
0 days left
EMD
97500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
dipka → Chhattisgarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Annual Repair And Maintenance Work Related To Water Supply System In Pragati Nagar Colony Of Dipka Area.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes |
| 2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes |
| 3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes |
| 4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal outer dia Pipes |
| 5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal outer dia Pipes |
| 6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal outer dia Pipes |
| 7 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore |
| 8 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore |
| 9 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia nominal bore |
| 10 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 32 mm dia nominal bore |
| 11 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 40 mm dia nominal bore |
| 12 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore |
| 13 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore |
| 14 | Providing and fixing PTMT pillar cock of approved quality and colour . 15mm nominal bore, 125 mm long foam flow. Weighing not less than 120 gms. |
| 15 | Providing and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 122 mm long, weighing not less than 99 gms. |
| 16 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
| 17 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 18 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 19 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore. |
| 20 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15 mm nominal bore |
| 21 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15mm nominal bore |
| 22 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.15 mm nominal dia |
| 23 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore |
| 24 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 25 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 26 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 27 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 15 mm nominal bore |
| 28 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal bore |
| 29 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 25 mm nominal bore |
| 30 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 32 mm nominal bore |
| 31 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 40 mm nominal bore |
| 32 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore. |
| 33 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore. |
| 34 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. |
| 35 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore. |
| 36 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore. |
| 37 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore. |
| 38 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 100 mm diameter Class II |
| 39 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 150 mm diameter Class II |
| 40 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 200 mm diameter Class II |
| 41 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 42 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. |
| 43 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 44 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 45 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : Above 40 mm nominal bore |
| 46 | Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres Up to 150 mm diameter |
| 47 | Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres Above 150 mm diameter |
| 48 | Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : |
| 49 | Supplying pig lead at site of work. |
| 50 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 100 mm dia nominal bore |
| 51 | Providing and fixing C.P. brass pillar cock of approved quality:15 mm nominal bore |
| 52 | Providing and fixing C.P. brass shower rose with 15 mm inlet : 100 mm diameter with CP brass arm of 300mm |
| 53 | Providing and fixing C.P. brass 2 in 1 Bib cock of approved quality conforming to IS:8931. 15 mm nominal bore. |
| 54 | Providing and fixing C.P. brass 2 in 1 Stop cock of approved quality conforming to IS:8931. 15 mm nominal bore. |
| 55 | Providing and fixing C.P. brass Single lever basin mixerof approved quality conforming to IS:8931. 15 mm nominal bore. |
| 56 | Providing and fixing uplasticised PVC connection pipe with brass unions :90 cm length 15 mm nominal bore |
| 57 | Providing and fixing C.P. brass hand shower rose with 15 mm inlet : 100 mm diameter with CP flexible connection pipe of 1 mtr long and 15mm nominal bore. |
| 58 | Providing and fixing CP brass health fauset with cpflexible connection pipe of 1 mtr long for use along western comode : 15 mm nominal bore |
| 59 | Providing and fixing 500 mm dia PVC cover for PVC water storage tankincluding nut bolt & hinges etc. |
| 60 | Providing and fixing CPVC extension nipple with check nut and seal ringsfor water tank pipe, fittings of approved quality. 20 mm nominal bore. |
| 61 | Providing and fixing CPVC extension nipple with check nut and seal ringsfor water tank pipe, fittings of approved quality. 25 mm nominal bore. |
| 62 | Providing and fixing ball valve (brass) of approved quality (screwed end) : 15 mm nominal bore. |
| 63 | Labour rate for laying G.I. pipesInternal work - Exposed on wall. 15 mm dia nominal bore. |
| 64 | Labour rate for laying G.I. pipesInternal work - Exposed on wall. 20 mm dia nominal bore. |
| 65 | Labour rate for laying G.I. pipesInternal work - Exposed on wall. 25 mm dia nominal bore. |
| 66 | Labour rate for laying G.I. pipesInternal work - Exposed on wall. 32 mm dia nominal bore. |
| 67 | Labour rate for layingG.I. pipes…. Internal work - Exposed on wall. 40 mm dia nominal bore. |
| 68 | Repairing of PVC low level flushing cystern with accessories like syphone,levers, flush pipe, fixtures, etc. as per need and instruction of EIC. |
| 69 | Repairing of CI sluice valves 80mm to 200mm nimonal bore as per instruction of Engineer-in-charge. |
| 70 | Removing /taking out of left out of the damaged fausetsall complete |
| 71 | Labour rate for repairing of pillar cock, bib cock, stop cock etc by replacing spendels and parts as required all complete. |
| 72 | Welding of pipe joints, junctions, welding necessary pipe pieces, socket, nipple etc all complete. |
| 73 | Lifting, lowering and rewinding of motor of old submersible pump 5 HP complete as per instruction of Engineer in charge. |
| 74 | Lifting, lowering and repairing of motor- pump of old submersible pump 5 HP complete as per instruction of Engineer in charge. |
| 75 | Repairing, Rewiding and reinstalation of 15/20HP pump monoblock pump-motor set complete as per instruction of Engineer in charge. |
| 76 | Lifting, lowering, supply and installation of submersible pump motor set 5 HP complete as per instruction of Engineer in charge. 8 stage. |
| 77 | Providing and fixing UPVCcolumn pipe of 50 mm dia complete as per instruction of Engineer in charge. |
| 78 | Providing and fixing 6 mm wire rope for lifting/ holding of submersible pump & pipes as per instruction of Engineer in charge. |
| 79 | Providing and fixing 3 core copper flat cable 4.0 sqmmsize of approved make |
| 80 | Providing and fixing CI adopter 50mm dia for cenetion of UPVC column pipe to submersible pump set and to outlet pipe over the ground. |
| 81 | Providing and fixing single phase control pannel box for submersible pump2 HP of L&T or equivalent make complete as per instruction of Engineer in charge. |
| 82 | Providing and fixing 3 phase control pannel box for submersible pump5 HP of L&T or equivalent make complete as per instruction of Engineer in charge. |
| 83 | Providing and fixing 3 phase oil cooled star delta type control pannel box for monoblock moter set 15 to 20 HP of L&T or equivalent make complete as per instruction of Engineer in charge. |
| 84 | Total Impact of GST for the Purpose of CTC |
AI Tender Summary
Tender Timeline
Dec 07, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedDec 25, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 26, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender