Tender For Providing Power Feeding Arrangement For Installation Of The New 1000Ah Battery And Power Plant And Miscellaneous Electrical Maintenance Work At Main Exchange, Kendrapara., kendrapara-Odisha

Bharat Sanchar Nigam Limited-BSNL has published Tender For Providing Power Feeding Arrangement For Installation Of The New 1000Ah Battery And Power Plant And Miscellaneous Electrical Maintenance Work At Main Exchange, Kendrapara.. Submission Date for this Tender is 28-12-2023. Electrical Maintenance Tenders in kendrapara Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

40969418
Corrigendum : Tender For Providing Power Feeding Arrangement For Installation Of The New 1000Ah Battery And Power Plant And Miscellaneous Electrical Maintenance Work At Main Exchange, Kendrapara.
Open Tender
Indian
Odisha
kendrapara
28-12-2023

Tender Details

Tender For Providing Power Feeding Arrangement For Installation Of The New 1000Ah Battery And Power Plant And Miscellaneous Electrical Maintenance Work At Main Exchange, Kendrapara.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Dec-2023 Extension of dates Date 28-12-2023

Key Value

Document Fees
INR 177 /-
EMD
INR 1505.0 /-
Tender Value
INR 75260.0 /-

BOQ Items

Name of Work: Providing power feeding arrangement for installation of the new 1000AH Battery and powerplant & Miscellaneous Electrical maintenance work at Main Exchange, Kendrapara.
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core flexible cable in the existing surface/ recessed steel/ PVC conduit as required.
26sqmm
34x10sqmm
4Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
532mm
6Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 4 way (4 + 12), Double door(Make- Legrand/L&T/Hager
7Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/Siemens/ L & T)
863 Amp 4 pole isolator
96-32Amps Single pole
10Blanking plate
11Supply of4 X 25 sq. mm size XLPE insulated Aluminium conductor armoured cable (A2XFY) 650/1100V grade confirming to IS:7098(Part-1) 1988etc. as required. (Polycab/Havells/ISI)
12Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradeup to 35sqmm on wall surface with GI saddles as required.
13Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradeup to 35sqin air as required.
14Laying ofof 1 no. PVC insl & PVC shtd XLPE power cable1.1KV grade-in ground, including excavation, sand cushioning, protective covering and refilling the trench ( up to 35sqmm)
15Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a). 4 X 25 sq. mm
16Supplyand fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
17Shifting of a spare power panel from BSNL Electrical Division at 15, Cantonment Road, to Kendrapara main Exchange i/c loading unloading etc compleate as required.
18Installation of the above LT panel on wall i/c ,testing and commissioning etc complete as required.
19Replacement offaulty SDFU switchesby new ones of following ratings after dismantlingthe old defective ones, fixing, connection & testing etc. as required.
2032 Amps 415 volts TPN SDFU withHRC fuses (open execution type). (Make: L&T FN type, /Havells / Siemens) .
21Replacement of faulty and damaged FTL fittings by new one of following ratings,LED Batten withpolycarbonate/Aluminium body suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells/Phillips / Surya / Polycab / Crompton)
2218-20 Watt LED tube light 4 feet length
23Carry out repairing of Electrical Light Fittings by arrangingqualified and trained man power and tools, tackles, ladders etc. i/c dismantling of defective/faulty components and fixing of new components i.e chokes, lamps, starters, interconnection wires, lamp holders etc. as required.
24Replacement of faulty and damaged compound light fittings by new ones of 45 wattnew generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection suitable for operation on 230 volts, 50 HZ AC supply i/c fixing, connection and testing etc. as required. (Make : Havells ENDURA SUNDOWN SL45WLED765PASYBOPC or Equivalent ofPhilips/ Wipro / Osaram / Crompton / Bajaj).