| 1 | Supplying anderectingrolledsteel joist(girder)pole100 x 116 mm (23 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ ( 8-1-13)Rs:-1658x 11 Mtr= 21554 |
| 2 | Painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. Specification no CW -PTG/PTP.( 16-4-3 ) |
| 3 | Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position.(8-6-15) |
| 4 | Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT ( 8-3-2 ) Garfing Angle |
| 5 | Supplying and erecting 75x40x6 mm with 4.4 mm thick web and 7.3 mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065 mm for 11 kV,1320 mm for 22 kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA (8-3-14 ) Top Fitting |
| 6 | Supplying and erecting vee cross arm with ISM channel of 75x40x6mm, for 11kV HTOH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators1220 mm bent at angle of 60 degreekeeping base 305 mm and the total vertical height of V cross arm as 460mm,and fixed on pole with MS clamp of 80x10 mm, nut bolts,washers complete as per specification no. OH-PL/VCA ( 8-3-12 ) |
| 7 | Supplying & erecting pole bracket fabricated from ISM channel of size 75x40x6mm, 1100mm long for necessary nos. of provided insulators and welded with extension channel pieces of same size 300 mm in length and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT( 8-3-10 )Cut PointChanel |
| 8 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority(6-1-19) Cut Point Breasing 50x50x6 mm 1.5 Mtr Long /7 Kgs / Nos x 6 Nos= 42Kgs |
| 9 | Supplying and erecting porcelain pin type insulator with G.I. pin suitable for 11kV line, complete asper specification no. OH-INS/PN (8-5-9) |
| 10 | Supplying and erecting porcelain disc type insulatorwith necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI (8-5-6) |
| 11 | Supplying and erecting ACSR conductor of size 6/1-3.66 mm complete. (Mink) (255 kg/km) as per specification No. OH-CON/ACSR(8-4-9) 40 MTRX 3=120 X 7 =840 |
| 12 | Supplying and erecting G.I. stay set for poles, including loopinsulatorsat inaccessible height complete with anchor plate300x300x6mm., strainingscrews,G.I.stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and poleclamps duly erected in provided cement concrete foundation. ( 8-6-2 ) |
| 13 | Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP ( 9-1-4 ) |
| 14 | Supplying and erecting ant climbing devices, fabricatedfrom pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. (10-6-17) |
| 15 | Danger Board Caution Board ( Market Rate ) |
| 16 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).( 16-3-7 ) sixe :- 0.60x0.60x1.8 For Pole =.648 x3 Poles = 1.94 + Stay :-1 Nos 0.60x0.60x1.5=0.54 x 1.94+0.54+ 2.48 CMT |
| 17 | Supplyinganderectingpole clamp madefrom50 x 6 mmMS flat for pole or pipe, postcompleteerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. ( 8-6-10 )Garding Angle 7 Nos |
| 18 | Supplyinganderecting ‘D’ type pole clamps, fabricatedfrom50 x 6 mm MS flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint.( 8-6-12 ) V Cross 7 Nos + Top Fittings 7= 14 Nos |
| 19 | Supplying and erecting \"C\" type (half) clamps for polemadefrom50 x 6 mm flatfor fixing cross arms by means of 15 mm dia. bolts andnutspaintedwith one coat ofredoxideandtwocoats of aluminium paint.( 8-6-13 ) Cut Point& Breasing 8 Nos x 6=48 + Garding Chanel 7=48+7=55 |
| 20 | Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.( 9-2-5 ) 0.100 Gm x / 500 mtr x2xX 0.106= For Gardings = 100 Kgs |
| 21 | Supplying and erecting guarding loop using G.l. wire no.8 SWG for L.T. overhead line of horizontal formation complete erected with 20 SWG GI wire as binding wire and 50 mm. section on each side, complete. (8-6-8) 15 Spans x 10= 7 Nos=70 |
| 22 | Supplying anderectingrolledsteel joist(girder)pole125 x 70 mm (13.3 kg/m)with provided base plate in provided foundation as per specification no. OH-PL/RSJ ( 8-1-10 ) Rs.:1056 Per/ Mtr x 9 = 9504 |
| 23 | Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position.(8-6-15) |
| 24 | Supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (Gnat) (73.77kg/km) as per specification no. OH-CON/AAC(8-4-2)2.5 KMX 4 Wire=10 km |
| 25 | Supplying anderecting all aluminium stranded conductors 7/3.10mm. complete. (Ant.) (145.0 kg/km)as per specification No. OH-CON/AAC ( 8-4-5 ) |
| 26 | Supplying & erectingMS pole bracket for guarding/LT OH Line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. OH -PL/BKT ( 8-3-1 ) |
| 27 | Supplying & erectingMS pole bracket for guarding/LT OH Line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. OH -PL/BKT (8-3-2) |
| 28 | Painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. Specification no CW -PTG/PTP.( 16-4-3 ) 9 Mtr x 4 36 Mtr |
| 29 | Supplying and erecting porcelain shackle type LT medium insulator 75x115 mm dia. with G.I. (Shackle) strips , nuts and bolts, complete.( 8-5-2 ) |
| 30 | Supplying and erecting aluminium bobbin with G.I. (shackle) strip, nuts complete. ( 8-5-4 ) |
| 31 | Supplyinganderectingpole clamp madefrom50 x 6 mmMS flat for pole or pipe, postcompleteerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. ( 8-6-10 ) |
| 32 | Supplyinganderecting ‘D’ type pole clamps, fabricatedfrom50 x 6 mm MS flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint.( 8-6-12 ) |
| 33 | Supplying and erecting \"C\" type (half) clamps for polemadefrom50 x 6 mm flatfor fixing cross arms by means of 15 mm dia. bolts andnutspaintedwith one coat ofredoxideandtwocoats of aluminium paint.( 8-6-13 ) |
| 34 | Supplying and erecting guarding loop using G.l. wire no.8 SWG for L.T. overhead line of horizontal formation complete erected with 20 SWG GI wire as binding wire and 50 mm. section on each side, complete. (8-6-8) |
| 35 | Supplying and erecting G.I. stay set for poles, including loopinsulatorsat inaccessible height complete with anchor plate300x300x6mm., strainingscrews,G.I.stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m length and poleclamps duly erected in provided cement concrete foundation.( 8-6-1 ) |
| 36 | Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP ( 9-1-4 ) |
| 37 | Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner ( 9-2-5 )0.106 Gram/ Mtr x 500Mtr = 100 Kgs |
| 38 | Making cement concrete foundation including excavation(60x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45x 45x 45) cm /45 cm dia. x 45 cm height plinth duly plastered,with necessary curing and finishing complete. (above 6 m to 9 m poles) ( 16-3-3 ) |
| 39 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50 ? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard ccessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.(10-1-5) |
| 40 | Painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. Specification no CW -PTG/PTP.( 16-4-3 ) |
| 41 | Supplying anderectingrolledsteel joist(girder)pole100 x 116 mm (23 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ ( 8-1-13)Rs:-1658x 11 Mtr= 21554 |
| 42 | Supplying & erecting 100 x 50x6 mm with 4.7 mm thickweb and 7.5 mm thick flange channeliron cross arm of suitable length for 2.4m wide DP structure and erecting on DP with 50x6 mm clamp as per approved method of construction and complete as perspecification no. OH-PL/BKT. ( 8-3-11 ) POWER/ FOUNDATION/D.O./AB.CHANEL |
| 43 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.(6-1-19) 1)D.O. Fuse Chanel 75 x 40x 3 Mtr. 6.5 Kgs / Mtr x3=19.5 Kgsx 4 Nos 78 Kgs.2) 50x 50x 6 Angle T/R Belt Angle-4.5 Kgs/ Mtr x 7 Mtr= 31 Kgs + 3)A.BHandel Breasing & 2 mtr = 4.5x 2 =78+31+9=118x2 DTC=236 Kgs |
| 44 | Supplyinganderectingbracket for guarding of HT OH Line, madefrom channeliron 1600 mm inlengthand 65 x 65 x 6mm thickerected on pole as per specification no. OH-PL/VCA ( 8-3-16 ) Garfing Angle |
| 45 | Supplying & erecting pole bracket fabricated from ISM channel of size 75x40x6mm, 1100mm long for necessary nos. of provided insulators and welded with extension channel pieces of same size 300 mm in length and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT( 8-3-10 )Cut PointChanel |
| 46 | Supplying and erecting ACSR conductor of size 6/1-3.66 mm complete.(Mink) (255 kg/km) as per specification no. OH-CON/ACSR ( 8-4-9 ) |
| 47 | Supplying and erecting 75x40x6 mm with 4.4 mm thick web and 7.3 mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065 mm for 11 kV,1320 mm for 22 kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA (8-3-14 )Top Fittings |
| 48 | Supplying and erecting porcelain pin type insulator with G.I. pin suitable for 11kV line, complete asper specification no. OH-INS/PN (8-5-9) |
| 49 | Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI (8-5-6) |
| 50 | Supplying and erecting distribution class, 11 kV thyrite type lightning arrester with nut bolts, on provided MS channel asper specification no. OH-INS/LA( 8-5-15 ) |
| 51 | Supplying and erecting G.I. stay set for poles, including loopinsulatorsat inaccessible height complete with anchor plate300x300x6mm., strainingscrews,G.I.stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and poleclamps duly erected in provided cement concrete foundation. ( 8-6-2 ) |
| 52 | Supplyinganderectingpole clamp madefrom50 x 6 mmMS flat for pole or pipe, postcompleteerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. ( 8-6-10 ) |
| 53 | Supplying and erecting ‘D’ type pole clamps, fabricated from 50x6mm MS flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of ( 8-6-12 ) |
| 54 | Supplying and erecting \"C\" type (half) clamps for polemadefrom50 x 6 mm flatfor fixing cross arms by means of 15 mm dia. bolts andnutspaintedwith one coat ofredoxideandtwocoats of aluminium paint.( 8-6-13 ) |
| 55 | Supplying and erecting \"C\" type (half) clamps for pole made from 50 x 10 mmflatfor fixing cross arms by means of 15 mm dia. bolts andnutspaintedwith one coat ofredoxideandtwocoats of aluminium paint. ( 8-6-14 ) |
| 56 | Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP ( 9-1-4 ) |
| 57 | Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.( 9-2-5 ) 8SWG 0.102Gram/Mtr 10 Mtr=1 Kgs |
| 58 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing for complete.(pole muffing or anyother purpose).(16-3-7) (1)FOR Pole =060x060x1.8=0.648x2=1.296 cmt +(2)FOR Stay ==060x060x1.8=0.648x2=1.296 cmt =2.59 |
| 59 | Supplying and erecting GI sheet 1.6 mm (16 SWG) to beused for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.(6-1-6)SIZE :-1.2x1.2x2=.88.Sq.Mtr+0.45X 8 =3.6=6.48=say 7 Sq. mtr |
| 60 | Supplying & erecting porcelain/epoxy bus bar support complete erected in provided MS box for 200/300A complete (5-10-27) |
| 61 | Supplying & erecting 415V, 200A porcelain base neutral link complete erected in provided M.S. box.(5-10-29) |
| 62 | Supplying & erecting 415V, 100A porcelain base neutral link complete erected in provided M.S. box.(5-10-25) |
| 63 | Supplying and erecting DIN Type HRC Fuse cartridge 500V, 160A (5-10-33) |
| 64 | Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required.As per specification no EA-EP. (9-2-1) |
| 65 | Supplying and erecting switch disconnector fuse (SDF) 415V, 200A, with enclosure, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V, with rotary handle for ON / OFF operation (without HRC fuse)(5-1-33) |
| 66 | Supplying and erecting approved make 11 kV outdoor type gang operated air break, triple pole switch400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \"C\" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. (10-6-2) |
| 67 | Supplying and erecting approved make, 11 kV outdoor type drop out fuse with insulator complete with fuse holders,fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm.(10-6-5) |
| 68 | Supplying and erecting ant climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. (10-6-17) |
| 69 | Supplying and erecting extra thick alkathene pipe 10 mm dia. erected to enclose bare conductor wires complete.. (use shall be restricted to H.T.)(10-6-11) |
| 70 | Supplying and erecting vee cross arm with ISM channel of 75x40x6mm, for 11kV HTOH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators1220 mm bent at angle of 60 degreekeeping base 305 mm and the total vertical height of V cross arm as 460mm,and fixed on pole with MS clamp of 80x10 mm, nut bolts,washers complete as per specification no. OH-PL/VCA ( 8-3-12 ) |
| 71 | Supplying and erecting porcelain shackle type LT medium insulator 75x115 mm dia. with G.I. (Shackle) strips , nuts and bolts, complete.( 8-5-2 ) |
| 72 | Supplying and erecting aluminium bobbin with G.I. (shackle) strip, nuts complete. ( 8-5-4 ) |
| 73 | Providing and fixing G.I. earthing stud with necessary materials. (8-5-5) |
| 74 | Supplying & erecting Siemens type brass cable glands for 3½ core 120 sq. mm. for XLPE armoured cable asper specification no. CB-GL (7-7-8 ) |
| 75 | Supplying & erecting Siemens type brass cable glands for 3½ core 240 sq. mm. for XLPE armoured cable as per specification no. CB-GL (7-7-10 ) |
| 76 | Supplying & erecting crimping type aluminium lugs for cable120 sq. mm. completeas per specification no. CB-CL/AL(7-10-7) |
| 77 | Supplying & erecting crimping type aluminium lugs for cable240 sq. mm. completeasper specification no. CB-CL/AL(7-10-10 ) |
| 78 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-22) |
| 79 | Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V 1 core 120 sq. mm. aluminium conductor complete erected with lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-3) |
| 80 | Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring anddisplay Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparenthinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supplycompany.(6-3-3) |