}

Tender For Refurbishment Of Sant Tukaram Natyagruh- Fire Fighting Works, Aurangabad-Maharashtra

Smart City Development Corporation Limited has published Tender For Refurbishment Of Sant Tukaram Natyagruh- Fire Fighting Works. Submission Date for this Tender is 13-12-2023. Fire Fighting Service Tenders in Aurangabad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

40950081
Tender For Refurbishment Of Sant Tukaram Natyagruh- Fire Fighting Works
Open Tender
Indian
Maharashtra
Aurangabad
13-12-2023

Tender Details

Tender For Refurbishment Of Sant Tukaram Natyagruh- Fire Fighting Works- 1 Supplying And Erecting G.I. Pipe‘C’ Class Erw25 Mm Dia With Necessary Fittings Complete Asper Specification No. Ff-Pp 2 Supplying And Erecting G.I. Pipe‘C’ Class Erw50 Mm Dia With Necessary Fittings Complete Asper Specification No. Ff-Pp 3 Supplying And Erecting G.I. Pipe‘C’ Class Erw65 Mm Dia With Necessary Fittings Complete Asper Specification No. Ff-Pp 4 Supplying And Erecting G.I. Pipe‘C’ Class Erw75 / 80 Mm Dia With Necessary Fittings Complete Asper Specification No. Ff-Pp 5 Supplying And Erecting G.I. Pipe‘C’ Class Erw100 Mm Dia With Necessary Fittings Complete Asper Specification No. Ff-Pp 6 Supplying And Erecting G.I. Pipe‘C’ Class Erw150 Mm Dia With Necessary Fittings Complete Asper Specification No. Ff-Pp 7 Providing G.I. Pipe‘C’ Class Erw200 Mm Dia With Necessary Fittings Complete Asper Specification No. Ff-Pp 8 Providing Coating Of Bitumen Paint &4Mm Thick Wrapping For Underground 150 Mm Ring Main Of Fire Fighting System. 9 Supplying And Erecting 100 Mm Dia Cast Iron Foot Valve Ball Type / Flap Typewith Strainer For Negative Suction Complete Asper Specification No. Ff-Vl / Fv 10 Supplying And Erecting 75 / 80 Mm Dia Cast Iron End Line Strainer Of Y-Type Flanged End Pattern, Pn16 Pressure Rating, Ss Screen, End Connection With Flanged / Screwed / Socket Weld / Butt Weld End Etc With Standard Oar ( Open Area Ratio ) Forpositive Suction Complete Asper Specification No. Ff-Vl / Els 11 Supplying And Erecting 100 Mm Dia Cast Iron End Line Strainer Of Y-Type Flanged End Pattern, Pn16 Pressure Rating, Ssscreen, End Connection With Flanged / Screwed / Socket Weld / Butt Weld End Etc With Standard Oar ( Open Area Ratio ) Forpositive Suction Complete Asper Specification No. Ff-Vl / Els 12 Supplying And Erecting 150 Mm Dia Cast Iron End Line Strainer Of Y-Type Flanged End Patternpn16 Pressure Ratingssscreen End Connection With Flanged / Screwed / Socket Weld / Butt Weld End Etc With Standard Oar ( Open Area Ratio ) Forpositive Suction Complete Asper Specification No. Ff-Vl / Els 13 Supplying And Erecting 200 Mm Dia Cast Iron End Line Strainer Of Y-Type Flanged End Pattern, Pn16 Pressure Rating, Screen Of Ss End Connection With Flanged / Screwed / Socket Weld / Butt Weld End Etc With Standard Oar ( Open Area Ratio ) Forpositive Suction Complete Asper Specification No. Ff-Vl / Els 14 Supplying And Erecting 150Mm Dia.Castiron Double Flange Sluicevalvecomplete With Pn16 Pressure Rating, Asper Specification No. Ff-Vl / Sv 15 Supplying And Erecting 75 / 80 Mm Dia. Cast Iron Double Flange Butterfly Valve Of Size Complete With Pn16 Pressure Rating, Asper Specification No. Ff-Vl / Bfv 16 Supplying And Erecting 100 Mm Dia. Cast Iron Double Flange Butterfly Valve Of Size Complete With Pn16 Pressure Rating, Asper Specification No. Ff-Vl / Bfv 17 Supplying And Erecting 75 / 80 Mm Diacast Iron Double Flange Nrv Complete With Pn16 Pressure Rating, Asper Specification No. Ff-Vl / Nrv 18 Supplying And Erecting 150 Mm Diacast Iron Double Flange Nrv Complete With Pn16 Pressure Rating, Asper Specification No. Ff-Vl / Nrv 19 Supplying And Erecting 25 Mmdiagunmetal Gatevalvecomplete With Pn16 Pressure Rating, Asper Specification No. Ff-Vl / Gv 20 Supplying And Erecting Stainless Steel Single Outlethydrantvalve Fitted With Necessary Accessories Complete Asper Specification No. Ff-Vl / Hv 21 Supplying And Installingone Piece Moulded Hdpe / Fibre Water Tank For Negative Suction Only, Having Capacity 1000Litres Fitted With Necessary Accessories Complete Asper Specification No. Ff-Ffa / Pt 22 Supplying And Installingwall Mounting Swinging Hose Reel Drum Fitted With 19 Mm Dia. 30M Long High Pressure Polypropylene ( Polyhose ) Along With Necessary Accessories Complete Asper Specification No. Ff-Ffa / Hv 23 Supplying And Erecting 63Mm Dia, Controlled Percolation ( C.P. ) Hose Pipe, 15M Inlength, Fittedwith Necessary Accessories Complete Asper Specification No. Ff-Ffa / Cph 24 Supplying And Erecting 63Mm Dia, Reinforced Rubber Lined ( R.R.L. ) Hose Pipe, 15M Inlength, Fitted With Necessary Accessories Complete Asper Specification No. Ff-Ffa / Rrl 25 Supplying And Erecting 150 Mm Dia Fire Brigade Header Suitable For Supplying Water In Fire Tank Complete Asper Specification No. Ff-Fa / Fbc 26 Supplying And Erecting Fire Brigade Header ( Siamese Connection ) Of 150 Mm Dia, For Supplying Water In Fire Tank Complete Asper Specification No. Ff-Fa / Fmc 27 Supplying And Erecting 300 Mm Dia 1.5Min Heightair Vessel / Tankfabricated From Min 5Mm Thick M.S. Sheet Complete Asper Specification No. Ff-Ffa / Act 28 Supplying And Erecting 100 Mm Dia. Pressure Gauge 0-300 Psi Or 0-14 Kg Per Cm Square Fitted With 12 / 15 Mm Dia. Pad Cock Valveerected With Provided G.I. Pipeelbow Etc. Complete Asper Specification No. Ff-Ffa / Pg 29 Supplying And Erecting 12 / 15 Mm Dia Pressureswitchwith Provided Isolationvalve, G.I. Nipple, Elbow, Etc Complete Asper Specification No. Ff-Ffa / Ps 30 Supplying And Erecting Brass Orifice Plate Having 6 Mm. Thickness, 140 Mm Outer Diawith Required Diameter Of Inner Hole At Every Single Outlet Hydrant Valve As Per Specification No. Ff-Ffa / Op 31 Supplying And Erecting M.S. / Crca Cabinet For Housing Single Hydrant Valveof Size ( 400 X 400 X 400 ) Mm Or Hose Pipe Boxof Size ( 600 X 600 X 200 ) Mm Made From Min. 1.5 Mm Thick Crca Sheet With Angle Iron Work Of Min. Of Size ( 25 X 25 X 4 ) Mmhaving Front Doors With Viewing Glass Of Size ( 200X150 ) Mmandlockingarrangement With Necessary Fixingmaterialsuch As Rubber Biddingetc. Dulypainted In Post Box Red Colour ( Code 538 Of Is 5 ) 32 Supplying, Installing, Testing And Commissioning Ofmulti Sensor Heat Detectorwith Smoke And Heat Combination ( Ror + Fix Temperature ) With Base On Back Box, Necessary Connections Complete Asper Specification No. Ff-Fas / Hd 33 Supplying, Installing, Testing And Commissioning Ofbeam Smoke Detector Four Wiresingle Ended Reflected Type With 8 Receiver Having Digital Display For Easy Alignment, Adjustable Sensitivity & Heater Kit For Transmitter / Receiver And Reflector With Necessary Connections On Suitable Back Box. The Protection Range Of Beam Detector Is 5 To 70 M. 34 Supplying, Installing, Testing And Commissioning Ofmanual Call Point ( Pill Box ) With Break Glass, Push Button ( Resettable Type ) In Metal Enclosure Complete Asper Specification No. Ff-Faas / Mcp 35 Supplying, Installing, Testing And Commissioning Ofhooters Having High ( 100Db @ 1M ) And Low ( 94Db @ 1M ) Volume Setting, Group Addressing Facility Allowing Multiple Sounders To Be Activated With Crca Enclosure Complete Asper Specification No. Ff-Faas / Htr 36 Supplying, Installing, Testing And Commissioning Ofremote Response Indicators Suitable To Operate On 5 - 28 V Dc Supply Having Fr Polymer Abs Housing Complete Asper Specification No. Ff-Faas / Rri 37 Supplying, Installing, Testing And Commissioning Offrlsxlpe Armouredcable 2 Core1.5 Sq.Mm. Copper Conductorcomplete Erected On Wall / Ceiling Complete Asper Specification No. Cb-Lt / Cu 38 Supplying, Installing, Testing And Commissioning Of14 Zones Microprocessor Based Conventional Fire Alarm Control Panel ( Facp ) With Standard Accessories 16X2characterlcddisplayprovision For Zone Wise Contact And Beep Sound Alarmsuitable To Operate On 120-220 V Ac 0 - 49 Deg C 93 ± 2 Percentage Rh ( Non- Condensing ) At 32± 2 Deg C Complete Asper Specification No. Ff-Faas / Facp 39 Supplying, Erecting, Testing And Commissioning Ofquartzoid Bulb Sprinkler, 15 Mm ( ½ ) Dia. Nbcm Body Chrome Finished, 68º C Fixed Temperature Rating With Deflector Disc Of Conventional Construction Complete As Per Specification No. Ff-Spr. 40 Supplying, Erecting, Testing And Commissioning Ofvane Type Water Flow Detector75 / 80 Mm Dia. With1 ) Visual Switch Activation 2 ) Rugged Switch Assembly 3 ) Heavy Duty Aluminium Pipe Saddles 4 ) Durable Metal Enclosure 5 ) Steel U Bolts For Secure Mounting 6 ) Two Spdt ( Single Pole Double Track ) Synchronised Switches 7 ) Serviceable Without Draining Pipes. 41 Supplying And Erecting Carbon Dioxide ( Co2 ) Fire Extinguisher Of 4.5 Kg. Capacity Cartridge Type Conform To Is 2878 / 15683 Complete Erected With Necessary Clamp Made From 50 X 6 Mm. M. S. Flat With Nut & Bolts Routed In Wall Complete. 42 Servicing Of Pump 43 Maintenance Of Control Panel 44 Cleaning Of Tank 45 Amc For 3 Years1 ) Inspection Visit & Maintenance Of Equipment: Checking / Testing / Cleaning / Oiling / Greasing Of All Components Related To Fire Safety Equipment, Including Fire Alarm System , Hydrant Delivery Valve, Hose Reel With Drum, Gate Valve, Fire Pump And Response Indicators ( R.I ) , Sprinkler System, Etc 2 ) Consumable Items Of Fire And Electrical Equipment Are To Be Replaced As And When Required.3 ) Cleaning And Painting: Basic Cleaning And Polishing Of Every Gun-Metal Make Vital Outlet, I.E., Adaptor Hydrant Valve, Branch Pipe, Fcb, Extinguishers Etc. And Cleaning Of Smoke Detector By Blower. 4 ) Maintenance Of Fire Fighting System Etc.: Overall Responsibility Of Maintenance Of Fire Fighting System, Fire Pumps Including Periodic Overhauling, Oiling, And Greasing, Preventing Maintenance Of Sprinkler System Leakage, Attending To Sprinklers As And When Necessary. Detection And Attending To Leakages If Any Within The System. Fire Fighting System Attendance ( Electrical Parts ) . Regular Checks And Drills As Per Safety Norms.5 ) Renewal Of Fire Noc: Liasioning With Wbf&Es For Getting Fire Noc, When It Falls Due For Renewal 6 ) Checking / Testing / Repairing / : Repairing Of Water Pipe Line Related To The Fire Fighting System 7 ) Mock Fire Drill & Training Program To Be Conducted With Prior Notice To Nsic.

Key Value

Document Fees
INR 1000 /-
EMD
INR 28750.0 /-
Tender Value
INR 28.74 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail