Tender For Repair Maintenance Of Internal Wiring Incl Sub Main Wiring Spn Tpn Dbs Building Security Lights At Bairagarh And Certain Repairs To Lt Network And Connected Works And Repair Maintenance Of Solar Water Heater Summer Appliance At Si Lines Under G, bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance Of Internal Wiring Incl Sub Main Wiring Spn Tpn Dbs Building Security Lights At Bairagarh And Certain Repairs To Lt Network And Connected Works And Repair Maintenance Of Solar Water Heater Summer Appliance At Si Lines Under G. Submission Date for this Tender is 01-01-2024. Electrification Work Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40950075
Corrigendum : Tender For Repair Maintenance Of Internal Wiring Incl Sub Main Wiring Spn Tpn Dbs Building Security Lights At Bairagarh And Certain Repairs To Lt Network And Connected Works And Repair Maintenance Of Solar Water Heater Summer Appliance At Si Lines Under G
Open Tender
Indian
Madhya Pradesh
bhopal
01-01-2024

Tender Details

Repair Maintenance Of Internal Wiring Incl Sub Main Wiring Spn Tpn Dbs Building Security Lights At Bairagarh And Certain Repairs To Lt Network And Connected Works And Repair Maintenance Of Solar Water Heater Summer Appliance At Si Lines Under Ge Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT OF INTERNAL WIRING INCLUDING SUB MAIN WIRING SPN/TPN, DB’S, BUILDING SECURITY LIGHTS AND CONNECTED ITEMS TO CERTAIN OFFRS/JCOS/OR MD ACCN AT BAIRAGARH AND CERTAIN REPAIRS TO LT NETWORK AND CONNECTED WORKS AND REPAIR/MAINT OF SOLAR WATER HEATER, SUMMER APPLIANCE AND MISC WORKS AT SI LINES UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
2Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
3M&L for concealed point wiring for one light/fan point with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC casing and caping of size 25 mm, ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS mutistranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly,including sunksheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface, including laminated hylum sheet cover, ISI marked of Make "Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code in IE rule.Rate includes chase cutting for concealed wiring.
4All as per item No. 2.00 here-in-before but for one light point controlled by two 2 way switches, with FRLS cables of 1.5 sqmm.
5All as per item No. 2.00 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches.
6All as per item No. 2.00 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switch.
7All as per item No. 2.00 here-in-before, but for bell buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm.
8All as per item No. 2.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
9All as per item No.2.00 here -in- before butwiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
10M&L for point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core,FRLS cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, ISI marked, drawn in existing concealed conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLS cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including newlaminated hylum sheet cover of min 3.0 mm thick , ISI marked of Make "Hylem"of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer complete all as specified and directed for the following:-
11(a) One light/fan point controlled by one switch.
12(b) One bell point controlled by one bell push
13(c) One light point controlled by two 2-way switches.
14(d)One 5 Amps socket out let point controlled by one switch on independent board.
15(e)One 5 Amps socket out let point controlled by one switch on same board.
16Allas per item 9.00 here-in-beforebut wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
17Allas per item 9.00 here-in-before butwiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
18M&L for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked, PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in and including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, including sunken box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface,including laminated hylum sheet cover, ISI marked of Make "Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code.
19(a) One light/fan point controlled by one switch.
20(b) One call bell point controlled by one push button on the same board with other switces.
21(c) One light point controlled by two 2-way switches.
22(d) One 3 pin socket outlet 5 Amps on independent board.
23(e)One 3 pin socket 5 Amp outlet on same board with other switch.
24Allas per item 12.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly
25Allas per item 12.00 here-in-before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
26S&F of switch piano, flush button, single pole, one way 5 Amp , 240 volts ISI marked complete all as specified and directed.
27S&F of switch piano, flush button, single pole, two way, 5 Amp, 240 voltsISI marked complete all as specified and directed.
28S&F of ceiling rose, surface type, 3 terminal, 240 V, ISI marked complete all as specified and directed.
29S&F of socket outlet 2-in-1, 5 pin 5 Amps, 240 volts, flush type complete all as specified and directed.
30S&F of switch socket combo outlet flush type multipurpose 2 in 1, 3 pin, 5 and 15 Amp, 230 volts complete all as specified and directed.
31S&F of switch piano flush type, single pole, 15 Amp, 240 volt,ISI marked complete all as specified and directed.
32S&F of socket piano flush type, single pole, 15 Amp, 240 volt,ISI marked complete all as specified and directed.
33S&F of step type electronic fan regulator, delux model, 100 watt, 240 V, flush type complete all as specified and directed.
34S&F in repairs lamp holder, PVC/Poly carbonate type with back plate suitable for batten fittings with and including 9 watt LED lamp accessories complete all as specified and directed.
35S&F of Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed. Make: Anchor/ Havells/Cona/ Leader
36S&F of Bell push, flush type, single pole, 5 Amp, 240 V complete all as specified and directed.
37Taking down old unserviceable sub main wiring of any size and any description complete all as specified and directed.
38S&F of modular switch one way 6 Amp one module, 240 volts complete all as specified and directed.
39S&F of modular bell push 6 Amp one module, 240 volts complete all as specified and directed.
40S&F of modular switch one way 16 Amp one module, 240 volts complete all as specified and directed.
41S&F of modular socket outlet 2-in-1, 2/3 pin, 6 Amps, 240 volts complete all as specified and directed.
42S&F of modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts complete all as specified and directed.
43S&F of modular fan regulator complete all as specified and directed.
44M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, medium grade, ISI markedincluding one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed.
45M&L for sub main wiringwith two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, medium grade, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed.
46M&L for sub main wiring with two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, medium grade, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed.
47M&L for sub main wiringwith two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm(with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing cappingincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
48M&L for sub main wiringwith two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping,includingone run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
49M&L for sub main wiringwith two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm(with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
50Taking down old unserviceable TPN / SPN MCB, DB"s including MCB"s of any size and any discription complete all as specified and directed.
51S&F of sheet metal enclosure for MCB, DB, TPN, 415 Volts with 200 amps rated busbar, 4 way, double door factory made confirming to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link suitable for mounting 63/100 Amps MCCB, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoningprotection against corrosive atmosphere IP 43 protection class complete all as specified and directed.
52S&F of sheet metal enclosure for MCB, DB, VTPN, 415 Volts with 200 amps rated busbar, 4 way, double door (vertical DB with MCB as incomer)factory made confirming to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link suitable for mounting 63/100 Amp MCCB as incomer, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoningprotection against corrosive atmosphere IP 43 protection class complete all as specified and directed.
53S&F of MCCB TPN 100Amps, 10 KA, "C" curve breaking capacity including connection with suitable size copper lugs complete all as specified and directed.
54S&F of MCCB TPN 63Amps, 10 KA, "C" curve breaking capacity including connection with suitable size copper lugs complete all as specified and directed.
55S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts with 200 Amps rated busbar, 12 way double door enclosure factory made of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
56S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts with 200 Amps rated busbar, 8 way double door enclosure factory made of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
57S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts with 200 Amps rated busbar, 4 way double door enclosure factory made of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
58S&F of sheet metal enclosure for MCB, DB, SP, 240 Volts without busbar, 2 way single door enclosure factory made of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
59S&F of MCB, SP, 240 Volts, 5 to 32Amps, 10 KA breaking capacity, "C" curve including connection with suitable size copper lugs complete all as specified and directed.
60S&F of MCB, SPN, 5 to 32 Amps, 10 KA , "C" curve including connection with suitable size copper lugs complete all as specified and directed.
61S&F of MCB, TPN, 40 to 63 Amps, 10 KA breaking capacity including connection with suitable size copper lugs complete all as specified and directed.
62S&F of single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V AC with and including one single pole MCB of capacity 20 Amps, `C` curve, breaking capacity 10 KA with industrial plug top complete all as specified and directed.
63S&F of LED tube rod 20 watt, 240V, PV > 0.90, colour temp 6500 K, complete with all accessories including connecting up with flexible 3 core copper conductor cable with suitable size including taking out old tube light fitting of any type complete all as specified and directed.
64Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6mm thick, buried directly in ground (earth pit not less level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth wire of 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR including earth pit in any soil, charcoal common salt layer 15 mm thick all around earth plate, PCC (1:3:6) type C1 in pit and PCC cover (1:2:4) type B1, water pipe funnel and GI protection pipe light grade 5mm dia upto panel connecting earth lead to panel complete all as specified and directed. Note : Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate.
65S&F of galvanised steel tubing light grade 80 mm dia for protection of cable laid on floor or fixed on walls complete all as specified and directed.
66S&F of galvanised steel tubing light grade 40 mm dia for protection of cable laid on floor or fixed on walls complete all as specified and directed.
67S&F of galvanised steel tubing light grade 50 mm dia for protection of cable laid on floor or fixed on walls complete all as specified and directed.
68S&F of galvanised steel tubing light grade 15 mm dia for protection of GI wire fixed/ laid on floor/wall complete all as specified and directed.
69S&F of earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on botton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washers complete and all as specified and directed.
70S&F of bulk head luminare weather proof, pressure die cast housing and high imapact resistance polycarbonate cover with and including one No. LED lamp 9W and connecting with copper flexible three core 23/0.0076 complete all as specified and directed.
71S&F in replacement surface mounted economical LED panel light, 2 ft x 2 ft, 36/40 watt with high quality diffuser for uniform light, CRCA housing, separate replaceable electronic driver, suitable for recess and surface, CRCA panel 36/40 ECW including LED lamp and all connected accessories complete all as specified and directed.
72S&F in replacement surface mounted economical LED panel light 1 ft x 1 ft, 18/20 watt with high quality diffuser for uniform light, CRCA housing, separate replaceable electronic driver, suitable for recess and surface, CRCA panel 18/20 ECW including LED lamp and all connected accessories complete all as specified and directed.
73Cutting PCC/floor/road for taking out/ laying of cable, GI earth wire, etc; for protection pipe of section 0.30 x 0.30 m with and including M&L for making good with PCC 1:2:4 B1 using 20mm graded stone aggregate as per existing after laying of pipe for cable protection, GI wire etc. complete all as specified and directed.
74S&F in replacement LED 9/10 Watt mirror tube light fitting, intergated type, approx2 feet, 240 V, PF > 0.90, colour temp 6500 K, suitable for surface mounting on wall including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified and directed.
75S&F in replacement LED lamp 9 Watt garden light fitting, 240 Volt, 50 Hz of approx height 2 ft with mounting arrangemet, clamps, etc. complete all as specified and directed.
76Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm x 2 core nominal cross section in service connections including taking down old cable complete all as specified and directed.
77Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm x 4 core nominal cross section in service connections including taking down old cable complete all as specified and directed.
78Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multistranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 16 Sqmm x 4 core nominal cross section in service connections incluidng taking out on cable complete all as specified and directed.
79Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multistranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 25 Sqmm x 4 core nominal cross section in service connections incluidng taking out on cable complete all as specified and directed.
80Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multistranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 50 Sqmm x 3.5 core nominal cross section in service connections incluidng taking out on cable complete all as specified and directed.
81Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multistranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 70 Sqmm x 3.5 core nominal cross section in service connections incluidng taking out on cable complete all as specified and directed.
82Excavation in trenches not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out in hard/ dense soil complete all as specified and directed.
83Returning filling in including spreading, leveling, and well ramming, in layers not exceeding 25 cm each layer obtained soil complete all as specified and directed.
84Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
85M&L for clean dry sand filling in trenches, sand unwashed including gently pouring around cables complete all as specified and directed. Note:-Punned thickness only measured for payment.
86M&L for old size "B" class bricks, well burnt, laid flat, for cable protection complete all as specified and directed.
87Taking out old building security light and supply and fixing building security light including GI Pipe of approx 1 mtr length and suitable size of led light of capacity 25 watt including weather protection cover nut, bolt and connected accessories complete all as specified and directed.
88S&F in repairs single phase direct connection type KWH meter, temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, confirming to IS:13779, IP 54, with (parameters to show date, time, current reading, KW, PF) in existing position by providing wooden board of first quality of size 250 mm x 300 mm including making electric connections complete all as specified and directed. Make : Secure/HPL/L&T Note : Old meter to be deposited in AGE E/M store.
89S&F in repairs three phase direct connection type KWH meter, temper proof, plastic body with LCD display, 230/240V per phase, 5-30 Amp, accuracy class I, 50 Hz, confirming to IS 13779, IP 54,with (parameters to show date, time, current reading, KW, PF) in existing position by providing wooden board of first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specified and directed. Make : Secure/HPL/L&T Note : Old meter to be deposited in AGE E/M store.
90S&F of 9 Watt Led bulb, 220 Volt, 50 Hz complete all as specified and directed.
91S&F of circular flexible FRLS copperconductor cable 1 sq mm x 3 core, 220 Volt, 50 Hz complete all as specified and directed.
92S&F of hanging rod of 2 feet long, medium grade suitable for hanging ceiling fan complete all as specified and directed.
93S&F of mild steel screws of required sizes for mounting / tightning electric boards of similar work complete all as specified and directed.
94Supply and replacement of 3 pin plug top AC-230 V, 15 Amp, complete all as specified and directed.
95Supply and replacement of 3 pin plug top AC-230 v 5 Amp complete all as specified and directed.
96S&F in repairs laminated hylum sheet cover, ISI marked, cutting grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in location with new galvanised screw and cup washer complete all as specified and directed of following sizes :
9711 x 13 inches
989 x 11 inches
995 x 8 inches
1005 x 5 inches
101S&F in replacement of the following spares of geyser and testing after replacing the defective part for proper functioning of geysers complete all as specified and directed.
102(a) Thermostat ISI marked Make: Danfoss / Ranco / Indfoss
103(b) Triangle heating element 1.5 KW, ISI marked Make: Bajaj / Usha/Theta
104(c) Triangle heating element2 KW,ISI marked Make : Bajaj / Usha/Theta
105(d) Indicator lamp with flexibe copper wire of suitable size (Red & Green)
106(e) Round heating element 1.5 KW,ISI marked Make: Bajaj / Usha/Theta
107(f) Round heating element2 KW, ISI markedMake : Bajaj / Usha/Theta
108(g) PVC connection with steel reinforced pipe for hot water connection with brass nuts of size 18" x 1/2" including rubber washers.
109S&F in repairs one core 2.5 Sq mm FRLS mutistranded copper conductor cable complete all as specified and directed.
110Dismantiling of existing ACSR (of any size or type) from over head electric line carefully without making any damage complete all as specified and directed.
111Dismantling of cross arms, bracings, supports, clamps and back plates from existing poles (other than dismantling poles) and pole structures complete all as specified and directed.
112Dismantling of insulators from existing poles any type any size complete all as specified and directed.
113Taking out old unserviceable cable from trenches of any size complete all as specified and directed.
114Excavation in trenches not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out in soft disintegratedcomplete all as specified and directed.
115M&L for foundation for steel tubular poles of PCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed at site.
116M&L for PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) for coping of poles and similar work including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
117M&L for providing of newflat LV precast cable cover unreinforced, size 250mm x 150mm x 40mm for protection of under ground cable complete all as specified and directed.
118Taking down old/ unserviceable GI tubing of any dia and description complete all as specified and directed.
119S&F in replacement MCCB, 4 pole, 415 Volts, adjustable type, 200 Amps, 50Hz, 36KA including connection with suitable size copper lugs complete all as specified and directed.
120S&F in replacement MCCB, 4 pole, 415 Volts, adjustable type, 250 Amps, 50Hz, 36KA including connection with suitable size copper lugs complete all as specified and directed.
121S&F in replacement MCCB, 4 pole, 415 Volts, adjustable type, 400 Amps, 50Hz, 36KA including connection with suitable size copper lugs complete all as specified and directed.
122M&L for re-streching of loose over head ACSR conductor of any type/GI wire and repairong of broken conductors and adding additional conductor of required length (if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with wire (old conductor shall be reused where required for repairing broken length of conductor) complete all as specified and directed. Note:- Five lines together will be measured as one span from pole to pole or approx 30 m.
123M&L for earthing complete with galvanised steel plate electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earthing strip of dimension 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including testing complete all as specified and directed. NOTE: Necessary excavation to be measured under respective item of schedule.
124M&L for preparation of old painted surface of LT PCC poles and painting strips in alternate from bottom to top with three strips of black synthetic paint and two strips of white fluoroscent paint (upto 1.5 metre height) throughout the circumference of pole (width of each strip shall be 30 cm) including marking pole numbers in a 20 cm dia yellow circle with number writing with black synthetic enamel paint including one coat of lime wash on PCC coping of pole complete all as specified and directed.
125M&L for preparation of old painted surfaces of LT steel poles and applying a coat of aluminium paint on all steel surfaces such as channels, angles, etc; of any description and zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips of 5 cm wide in green (02 Nos) and white (01 No) colour at a height of 1.25 mtr from coping of pole with and including writing the pole number in black colour on yellow background on the pole and a coat of cement base paint on PCC coping of poles complete all as specified and directed.
126M&L for installing GI strip of32x6 mm dimensions and making proper arrangements for connection between earthing and Transformer/ equipment complete all as specified and directed.
127Repairing of outdoor type LT panel board mounted on angle / PCC floor of any size with and including replacement of unserviceable switch/control gears, connector, indicator lamps, panel door lock and other minor repairs including rewiring and extension of incoming and out going cables (cable excluded) by opening of loops/making joints and providing cable lugs /thimbles as reqdincluding repairing rusted part of sheet metal door with existing size MS sheets by necessary arc/gas welding and removing all dirt, dust etc. with air blower and painting complete panel board with two coats of synthetic enamel spray painting over a coat of red oxide primer including writing identification works complete all as specified and directed, panel is comprising of the following items:- (a) MCCB 100 A to 400 A, 3/4 pole415 Volt-04 to 06 Nos (b) Indicator Lamp RYB LED type with fuse.-01 set (c) Aluminium bus bar RYB & N of 200 A size -01 set (d) Amp / Volt Meter 02 Nos (e) MCB TPN/SPN/SP mounting on bus bar -01 to 6 Nos Note: (i) Cost ofproviding aluminium thimbles, earth and neutral link, insulator, hylem sheet, any type of screws or any other minor spares of any type as required at site is deemed to be included in the quoted rate. (ii)MCCB, MCB, aluminium bus bar, indicator lamp, Amp / Volt meter or any other major parts required for relacement shall be measured and paid serately in relevent item.
128S&F in replacement LED type indicating lamp for indication of RYB complete all as specified and directed.
129S&F in replacement aluminium bus bar rating 200 Amps, 25/6 mm including making hole suitable for panel with tape insulation of suitable colour in phase RYB & neutral in black colour complete all as specified and directed.
130Supply, fixing, testing, commissioning of LT panel board of size 600x600x400 mm,weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet3.15 mm thickouter and 2.00 mm thick for inner door confirming to IS/IEC 61439 with angle iron 50x50x6 mm, outoor floor mounting type with closedaluminium bus bar chamber including necessary insulators suitable for 3 phase, 4 wire, 50 Hz, AC, CPRI approved including provn of digital ammeter 0-350 Amps, digital voltemeter 0-500 Volts, CT"s of suitable ratio, indicator lamps R-Y-B, selector switches and internal wiring and grouting legs in PCC, providing suitable cable glands, cable lugs, nuts, bolts, washers etc. bottom portion of panel shall be min 60 cm above ground level and taking out old LT panel complete all as specified and directed with and including of the following ietms:- (a) Aluminium bus bar capacity 300 Amps for Phase-R-Y-B-3 Nos & neutral -1 No (b) MCCB, FP, 36 KA, 250 Amps- 01 No (Incoming) (c) MCCB, FP, 36 KA ,100 Amps - 02 Nos (Outgoing) (d) MCCB, FP, 16 KA, 63 Amps - 02 Nos (Outgoing) (e) MCCB, FP, 10 KA, 40Amps - 02 Nos (Outgoing) (f) MCB, DP, 10 KA,40 Amps - 02 Nos (Outgoing) (g) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT of ratio 0-300 Amps (h) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No 0-500 V. (j) Complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder.
131S&F in replacementlugs after cutting the worn out /faulty cable end from LT pillar/panel box and making cable lead by providing new aluminium lugs including crimping with crimping tools in the existing LT cable of size upto 50 Sqmm and connecting complete all as specified and directed.
132S&F in replacementlugs after cutting the worn out /faulty cable end from LT pillar/panel box and making cable lead by providing new aluminium lugs including crimping with crimping tools in the existing LT cable of size 70 to 120 Sqmm and connecting complete all as specified and directed. All as per item No 117.00 here-in-before but aluminium lugs of size 70 to 120 Sq mm.
133M&L for replacement of steel tubular swaged poles with steel base plate 300x300x6mm, final taper plug, bolts, nuts and screws as specified type 410 SP-31, 9.0 mtr longincluding excavation, earth work etc including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black & whitepaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
134S&F in replacement pole box of size 300x 200 x 100 mm fabricated out of 2 mm thick mild steel sheet duly powder coated having 4 Nos aluminium busbar of suitable size with and including 1 No. MCB SP 10 Amps including proper locking arrangement with front openable hinged cover outdoor type weather proof suitable for mounting on steel/ PCC pole including fixing mild steel clamp 02 Nos with nuts, bolts and washers including wheather proof PVC insulated flexible 1.5 sq mm 3 core copper conductor cable for connection of pole junction to street light complete all as specified and directed.
135S&F in replacement of heat shrinkable outdoor type LT straight through jointing kits for 3.5 core, 25 sq mm to 50 sqmm XLPE/PVC insulated LT armoured cable with lugs complete all as specified and directed.
136S&F in replacement of heat shrinkable outdoor type LT straight through jointing kits for 3.5 core, 70 sq mm to 95 sqmm XLPE/PVC insulated LT armoured cable with lugs complete all as specified and directed.
137Taking down of solar water heating system of 500 LPD capacity from its position after disconnecting water connections and refixing /reassembling in position after carring out neccessary repair work and painting to staging of solar panel frames, hot water tank frame with one coat of synthetic enamel paint by spray gun including necessary preparation of surfaces and testing complete all as specified and as directed. Note:- (a) Rate quoted by the contractor deemed to have been included making good of missing nuts, bolts and washers, screws etc to make it full functional. (b) Descalling/desludging, cleaning and washing of solar panels, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and reassembling the panels including necessary welding of collector fins as required, (c) Any other spare parts needed for smooth functioning shall be measured and paid seperately.
138All as per item No 115.00 here-in-before but of 200 Litre per day capacity
139All as per item No 115.00 here-in-before but of 100 Litre per day capacity
140S&F of solar energy collector panel made of aluminium body with 5mm thick toughened glass complete with copper fins of capacity 200 litres per day complete all as specified and directed.
141S&F of solar energy collector panel gasket made out of superior quality rubber to make system air tight, dust and water proof complete of capacity 200 litres per day complete all as specified and directed.
142S&F of compressed glass wool (insulation materials) 48mm thick between solar energy collector panel copper tubes frame and aluminium body panel including securing it on panel by means of necessary adhessive completeall as specified and directed.
143S&F in repairs GI tubing medium grade for hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore with all fittings complete all as specified and diretced.
144S&F in repairs GI tubing medium grade for hot water pipe duly insulated with glass wool and aluminium cladding 25 mm bore with all fittings complete all as specified and diretced.
145S&F of anti freezing liquid in 20 ltr PVC can for solar water heater system complete all as specified and directed.
146S&F of GI tubing 25 mm dia medium grade along with all fittings as required fixed to wall, floor or ceiling complete all as specified and directed.
147S&F of GI tubing 15 mm dia medium grade along with all fittings as required fixed to wall, floor or ceiling complete all as specified and directed.
148S&F in replacement bib taps, cast copper alloy, chromium plated fancy type with capstan head, screwed down, screwed for 15 mm dia bore iron pipe complete all as specified and directed.
149S&F in replacement stop valves, cast copper alloy, chromium plated fancy type with capstan head, screwed down, screwed for 15 mm dia bore iron pipe complete all as specified and directed.
150S&F in replacement of stop valves, cast copper alloy, chromium plated fancy type with capstan head, screwed down, screwed for 20 mm dia bore iron pipe complete all as specified and directed.
151S&F in replacement of stop valves, cast copper alloy, chromium plated fancy type with capstan head, screwed down, screwed for 25 mm dia bore iron pipe complete all as specified and directed.
152Removing defective window/split type air conditioner of any make and capacity from various locations and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and re-fixing at various locations after repairing including testing on load at site complete all as specified and directed. Note:- All spares compressor, fan motor, relay, capacitor, over load, etc. shall be measured and paid separately.
153Removing unserviceable burnt sealed compressor from air conditioner and fixing only new rotary / sealed unit compressor of any capacity with and including M&L for necessary welding of connection with existing refrigerant pipe and supply and charging refrigerant gas as per requirement including testing complete all as specified and directed. Note:- Sealed unit compressor shall be measured and paid separately under respective item of Schedule "A".
154Taking out window/split type air conditioner of any make and capacity from position and cleaning the complete cooling coil and condenser coil with chemical base solution and soda water including servicing, oiling, greasing complete air conditioner checking of electrical connection and re-fixing the same in existing or other location after testing complete all as specified and directed.
155S&F of new hermitically sealed / rotary type compressor of Capacity 1.5 TR with warrenty of two years from the manufacturer complete all as specified and directed.
156S&F of new hermitically sealed / rotary type compressor of Capacity 2.0 TR with warrenty of two years from the manufacturer complete all as specified and directed.
157S&F of FHP motor of capacity 1/5 to 1/18 single phase 920 RPM with starting and running capacitor suitable for window type AC complete all as specified and directed.
158S&F of starting capacitor 80-100 MFD/ 100-120 MFD/120-150 MFD complete all as specified and directed.
159S&F of running capacitor 45 MFD complete all as specified and directed.
160S&F of running capacitor 36 MFD complete all as specified and directed.
161S&F of starting relay suitable for 1.0 /1.5 /2.0 TR compressor complete all as specified and directed.
162S&F of rotary/push type selector switch suitable for 1.5/2.0 TR window type AC complete all as specified and directed.
163S&F of thermostat suitable for 1.0 /1.5 /2.0 TR window / split type AC complete all as specified and directed.
164S&F of outer back cover of steel sheet heavy duty duly powder coated painted for window type AC of capacity 1.5 / 2.0 TR complete all as specified and directed.
165S&F of front grill for window type AC of any model all required at site complete all as specified and directed.
166S&F of condenser/cooling fan blade suitable for 1.5/2 TR window type AC of any make complete all as specified and directed.
167S&F of blower fan motor suitable for split AC of any capacity and make complete all as specified and directed.
168S&F of PCB for a window/split type AC of any capacity and make with remote complete all as specified and directed.
169S&F of blower with both end coupled complete suitable for split AC 1.5 / 2.0 TR capacity of any make complete all as specified and directed.
170S&F of copper cooling coil indoor suitable for split type AC of capacity 1.5 / 2.0 TR complete all as specified and directed.
171S&F of copper liquid line filter, two way / one way suitable for split AC complete all as specified and directed.
172S&F of remote for split AC as per sample complete all as specified and directed.
173S&F in repairs three core 4 Sq mm FRLS mutistranded copper conductor cable complete all as specified and directed.
174S&F in replacement wiring loom/ harness for air conditioner complete all as specified and directed.
175S&F of condenser/cooling coil suitable for 1.5/2.0 TR air conditioner including necessary welding work complete all as specified and directed.
176M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality enameledcopper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enamel black paint complete all as specified and directed.
177Taking out damaged tray from window type air conditioners and M&L for replacing with existing shape and size steel tray including all necessary work such as welding, nuts, bolts, drilling etc. suitable for 1.5 / 2.0 TR air conditioners complete all as specified and directed.
178M&L for charging of refrigerant gas R-32/R-22/R-410a in window / split type air conditioners of 1.5 / 2.0 TR capacity at existing position including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line, copper pipe etc. ir required and testing complete all as specified and directed.
179Taking out old unserviceable voltage stabilizers of capacity 0.5 KVA to 5 KVAfrom MES store/site and repairing the same in MES work shop complete all as specified and directed. Note: (i) If the transformer found burnt, the in same shall be re-winded and will be measured and paid seperately. (ii) Spares required shall be measured and paid seperately under respective item of Schedule "A".
180S&F of main relay 24 Volts, 25 Amps suitable for voltage stabilizers complete all as specified and directed.
181S&F of main control circuit (PCB) suitable for voltage stabilizers complete all as specified and directed.
182S&F of output terminal 32 Amps suitable for voltage stabilizers complete all as specified and directed.
183S&F of censor transformer suitable for voltage stabilizers complete all as specified and directed.
184S&F of voltmeter 96 x 96 mm for voltage stabilizers complete all as specified and directed.
185S& F of time relay 2-3 minute over low voltage 180 volts AC and high voltage 260 Volt AC for voltage stabilizers
186Taking out old burnt winding work with and including re-winded with super enameled copper winding wire of existing size suitable for 5 KVA voltage stabilizers with all necessary insulating material and testing complete all as specified and directed.
187Taking out old burnt winding work with and including re-winded with super enameled copper winding wire of existing size suitable for 4 KVA/3 KVA voltage stabilizers with all necessary insulating material and testing complete all as specified and directed.
188Taking out old burnt winding work with and including re-winded with super enameled copper winding wire of existing size suitable for 2 KVA / 1KVA voltage stabilizers with all necessary insulating material and testing complete all as specified and directed.
189Transporting refrigerator of any make and capacity from MES store yard to contactor’s workshop for repairs as mentioned in respective items including returning refrigerator back to MES store yard after repairs and testing complete all as specified and directed.
190Removing unserviceable burnt sealed compressor from air conditioner and fixing only new sealed unit compressor of any capacity with and including M&L for necessary welding of connection with existing refrigerant pipe and supply and charging refrigerant gas as per requirement including testing complete all as specified and directed. Note:- Sealed unit compressor shall be measured and paid separately under respective item of Schedule "A".
191S&F of new sealed compressor suitable for refrigerator / deep freezer of capacity 165 / 286 / 310 / 500 Ltrs capacity with warrenty of two years from the manufacturer complete all as specified and directed.
192S&F of relay suitable for refrigerator/deep freezer 165/286/310 Ltrs capacity complete all as specified and directed.
193S&F of over load suitable for refrigerator/deep freezer 286/310 Ltrs capacity complete all as specified and directed.
194S& F of hermostat suitable for refrigerator/deep freezer 165/286/310 Ltrs capacity complete all as specified and directed.
195S&F of PVC freezer door suitable for refrigerator as per existing size of any capacity complete all as specified and directed.
196S&F of chiller tray of any make and capacity suitable for refrigerator complete all as specified and directed.
197S&F of vegetable tray of suitable size for refrigerator of any make and capacity complete all as specified and directed.
198S&F of shelves of suitable suitable size for refrigirator of any make and capacitycomplete all as specified and directed.
199S&F of magnetic rubber door gasket of suitable size for refrigerator of any make and capacity complete all as specified and directed.
200S&F of freezer temp control fan motor suitable for refrigerator of any make and capacity complete all as specified and directed.
201S&F of timer box suitable for refrigerator double door of capacity200/ 310 Ltr complete all as specified and directed.
202S&F of PVC rounded 3 core, 2.5 Sqmm copper conductor work shop cable complete all as specified and directed.
203S&F of freezer box / chiller assembly complete with coil and chamber of any make and capacity suitable forrefrigerator complete all as specified and directed.
204S&F of fan motor 16/25 watts, 220-240 Volts suitable for deep freezer of any make and capacity complete all as specified and directed.
205M&L for charging of refrigerant gas R-22 in refrigerators/ deep freezer at existing position including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line, copper pipe etc. ir required and testing complete all as specified and directed.
206M&L for charging of refrigerant gas R-134a in refrigerators/water coolers at existing position including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line, copper pipe etc. ir required and testing complete all as specified and directed.
207Transporting water coolers of any make and capacity from various locations to contactor’s workshop for repairs as mentioned in respective items including returning water coolers back to position after repairs and making neccessaray electrical/ water connections and testing complete all as specified and directed.
208Removing unserviceable burnt sealed compressor from water coolers and fixing only new sealed unit compressor of any capacity with and including M&L for necessary welding of connection with existing refrigerant pipe and supply and charging refrigerant gas as per requirement including testing complete all as specified and directed. Note:- Sealed unit compressor shall be measured and paid separately under respective item of Schedule "A".
209S&F in replacement new FHP motor with suitable fan blade, single phase, 1/8 to 1/35 HP suitable upto 150 Ltrs capacity water coolers complete all as specified and directed.
210Taking out water coolers of any make and capacity from position and cleaning the complete storage tank and condenser coil with chemical base solution and soda water including servicing, oiling, greasing complete of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing up to satisfaction complete all as specified and directed.
211S&F of new sealed compressor suitable for water coolers of 150 Ltrs capacity with warrenty two years from the manufacturer complete all as specified and directed.
212S&F of new sealed compressor suitable for water coolers of 40/80 Ltrs capacity with warrenty two years from the manufacturer complete all as specified and directed.
213S&F of new sealed compressor suitable for water coolers of 120 Ltrs capacity with warrenty two years from the manufacturer complete all as specified and directed.
214S&F of relay and OLP suitable for water coolers of any make and capacity complete all as specified and directed.
215S&F of thermostat switch suitable for water cooler of any make and capacity complete all as specified and directed.
216S&F of push taps, brass metal body, chromium plated suitable for water coolers (as per sample) complete all as specified and directed.
217S&F of fan motor blade of 12" sweep suitable for FHP motor for water coolers complete all as specified and directed.
218S&F of PVC flexible pipe transparent 15mm/20mm dia heavy duty complete all as specified and directed.
219S&F of 15/20 mm bore ball PVC valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and directed.
220S&F of running capacitor of 4 MFD capacity complete all as specified and directed.
221M&L for charging of refrigerant gas R-22 in water coolers at existing position including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line, copper pipe etc. ir required and testing complete all as specified and directed.
222S&F of condenser coil complete with copper tube and aluminium fins for water coolers of any make and capacity as per sample complete all as specified and directed.
223Taking down/out desert cooler of any make and capacity from various locations, transporting to MES store yard and dismantling all unserviceable parts for repair/overhauling and re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 sqmm complete all as specified and directed. Note: Spare parts required shall be measured and paid seperately.
224M&L for replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make and size complete all as specified and directed.
225S&F in replacement front grill air diverter of PVC with selector switch and 2 Nos. indicator lamps for desert cooler of any make and capacity complete all as specified and directed.
226S&F of fan condenser, 230 Volts of the 3.5 MFD for fan motor of desert cooler complete all as specified and directed.
227M&L for rewinding of stator of exhaust fan/kit fan 18” sweep, 900 RPM of any make with super quality of winding copper wire of existing gauge with varnishing, backing including painting with synthetic enameled paint and testingcomplete all as specified and directed.
228M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top, sides and tank fabricated out 22 SWG PGI sheet of size not less than 81.5 x 80.5 x 97.5 cm with double diversion grills and grill box suitable for 18” sweep fan, heavy duty with submersible water lifting pump of capacity 1.25 M head, 230 Volts of suitable capacity and making holes with fixing arrangement including 4 way PVC distributor, 15mm dia PVC pipe 3 to 4 mtr for spray water, wood wool pads, electrical wiring for fan and pump controlled separately with 5 amp piano type switch and indicator etc complete all as specified and directed.
229S&F in replacement of submersible water lifting pump of capacity 1.25 m head, 230 Volts complete all as specified and directed.
230S&F in replacement kit fan motor 450 mm sweep 1350 / 1400 RPM, 240 volts complete all as specified and directed.Make : Everest / Summer Cool / Khaitan
231S&F of desert cooler PCB of suitable for branded plastic desert cooler as per sample complete all as specified and directed
232S&F of 15mm bore plastic flexible transparent pipe, PVC distributer and PVC angle nozzle (3 Nos.) for distribution of water along three sides of desertcooler complete all as specified and directed
233M&L for maintenance and servicing of DG set of capacity 160 KVA with and including of following operations:- (a) Draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the oil pan with new engine oil to it’s required level. (b) Draining out diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel. (c) Supply and replacement of fuel filter set. (d) Supply and replacement of lubricating oil filter set. (e) Supply and replacement by pass filter set and head gasket kit. (f) Cleaning of air filter. (g) Check and topping up coolant level. (h) Checking the starting batteries and filling with electrolyte/distilled water to maintain the required specific gravity, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & to brass connectors. (j) Clearning exhaust system including removing of deposited carbon in exhuast pipe. (k) Adjustment /setting of V belt and fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc. (l) Cleaning the DG Set with accessories as directed. (l) Checking, cleaning and servicing of self starter, alternator, sensors etc. (l) Testing of DG set at connected load as directed. Note: (i) Engine oil, fuel filter, oil filter, bypass filter, water filter, petroleum jelly, waste cloth, seals, gaskets etc; are to be provided by the contractor and the cost of same is deemed to be included in quoted rate. (ii) Coolant for topping up measured and paid saparetely. (iii) Engine oil /spares/filters of make recommended by OEM will only be used for servicing of DG set
234All as per item No. 211 here-in-before but maintenance and servicing of DG Set of capacity 125 KVA.
235All as per item No. 211 here-in-before but maintenance and servicing of DG Set of capacity 100 /110 KVA.
236All as per item No. 211 here-in-before but maintenance and servicing of DG Set of capacity 62.5 KVA.
237All as per item No. 211 here-in-before but maintenance and servicing of DG Set of capacity 50 KVA.
238All as per item No. 211 here-in-before but maintenance and servicing of DG Set of capacity 30 KVA.
239M&L for spray painting of DG sets of capacity upto and including 160 KVA (in situ) any type, installed and located at different sites in scattered area at SI line with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces by removing of burnt grease, dust, oil and other contaminants using de-greasing solvent, de-rusting of surface and cleaning manually by scrubbing by brushing, washing thoroughly and dry properly and writing SM/ MES No. at top of the corner of the body complete all as specified and directed.
240Dismantling and taking down radiator assy from engine of any capacity for repairs including descaling, bracing as necessitated to plug leakages, M & L for transporting of the radiator of capacity 30-160 KVA and repair/maintenance to the radiator fins with the help of cleaning coil solution and cleaning to the radiator complete and repair to the leakage places by means of gas welding and including initial filling up coolant and re fixing after repairs including replacement of worn out nut bolts, washers etc; and testing complete all as directed.
241Dismantling and transporting fuel injection pump of DG set at authorized service centres for and including re-calibrationafter replacement of necessary spare parts such as delivery valves, plungers, "O" ring, springs etc; and refixing after testing complete all as specified and directed of the following capacities:-
242(a) 160 KVA capacity
243(b) 125 KVA capacity
244(c) 100/110 KVA capacity
245(d) 30/ 50 /62.5 KVA capacity
246Supply and filling of lubrication oil 20 W 40 of Make: Castrol / Servo complete all as specified and directed.
247M&L for reconditioning of unserviceable battery, 12 Volts, 100/150/180 AH by replacing complete cells, PVC seperators, electrolyte, terminals and finally sealing, recharging and testing complete as directed.
248S&F in replecement of flame proof asbestos rope for exhaust pipe of DG set of size 8 by 10 mm thick complete all as specified and directed.
249M&L for overhauling of self starter 12 / 24 Volts of any make / capacity including replacement of minor items such as carbon brushes, nuts, bolts, etc; as required complete all as specified and directed. Note: Other additional spares as required will be measured and paid seperately.
250S&F in replacement of field coil for self starter 12 / 24 V complete all as specified and directed.
251S&F in replacement of armature for self starter 12 / 24 V complete all as specified and directed.
252S&F in replacement of clutch asssembly for self starter 12 / 24 V complete all as specified and directed.
253S&F in replacement of battery lead of copper conductor 25 Sq mm, multi stranded, PVC insulated cable with suitable terminals at both ends complete all as specified and directed.
254S&F in replacement of battery terminal of brass suitable for 12 V, 180 AH battery complete all as specified and directed.
255S&F in replacement of battery charger with variable voltage and current setting suitable for charging 2 x 12 V battery in steel sheet cabinet complete with internal and external wiring including all measuring and control accessories/ instruments complete all as specified and directed.
256S&F in replacement of fan belts suitable for 100/110/125/160 KVA DG sets as per sample complete all as specified and directed.
257S&F in replacement of fan belts suitable for 30/50/62.5 KVA DG sets as per sample complete all as specified and directed.
258S&F in replacement of fuel flexible pipe, hose pipe, heavy duty with check nuts for DG sets of any make/capacity complete all as specified and directed.
259Dismantling of alternator assembly of 30/50/62.5/100 KVA DG sets and taking out regulating transformer carefully with and including rewinding of regulating transformer with super quality binding wire of suitable gauge and refitting and testing complete all as specified and directed.
260S&F in replacement of oil pressure gauge of DG set of any capacity as per sample complete all as specified and directed.
261S&F in replacement of temperature gauge of DG set of any capacity as per sample complete all as specified and directed.
262S&F in replacement of solenoid valve suitable for 100 KVA DG set complete all as specified and directed.
263S&F in replacement of control safety (Lub oil) unit suitable for 100/110/160 KVA DG set complete all as specified and directed.
264S&F in replacement of control safety (Water) unit suitable for 100/110/160 KVA DG set complete all as specified and directed.
265S&F in replacement of electronic AVR assembly suitable for 160/125/100 KVA DG set complete all as specified by Engr-in -charge.
266S&F in replacement of electronic AVR assembly suitable for 30/50/62.5 KVA DG set complete all as specified and directed.
267S&F in replacement of fan blade suitable for 160/125/110/100 KVA DG set complete all as specified and directed.
268S&F in replacement of fan blade suitable for 30/50/62.5 KVA DG set complete all as specified and directed.
269Supply and filling in replacement of oil coolant additive concentrate pack of 10 Ltrs suitable for DG set complete all as specified and directed.
270Supply and filling in replacement distrilled water in 5 ltrs PVC container in DG sets complete all as specified and directed.
271S&F in replacement air filter outer & inner element suitable for 160/125/110/100 KVA DG sets complete all as specified and directed.
272S&F in replacement air filter outer & inner element suitable for 62.5/50/30 KVA DG sets complete all as specified and directed.
273S&F in replacement wiring loom/ harness suitable for DG set of any capacity as per samlpe complete all as specified and directed.
274S&F in replacement alternator cutout assembly suitable for 110/100KVA DG set complete all as specified and directed.
275S&F in replacement alternator cutout assembly suitable for 30/50/62.5 KVA DG set complete all as specified and directed.
276Replacement of radiator assembly complete suitable for 30/50/62.5 KVA DG set including all fixing arrangements complete all as specified and directed.
277Disconnecting and taking out the unservisable turbocharger assembly of DG set 125/100/62.5 KVA and transporting it to workshop, dismantling of turbo charger and replacement of turbocharger repair kit and then re-assembling and fixing back to engine and testing complete all as specified and directed.
278S&F in replacement of exhaust silencer set of any capacity DG set with all connecting items such as welding work, nuts bolts, support clamps etc. complete all as specified and directed .
279M&L for repairing and decarburizing of exhaust manifold system of DG Set 110/100 KVA with and including replacement of nuts, bolts, washers, etc; complete all as specified and directed.
280S&F in replacement of VAF meter, 50 Hz suitable for 100 KVA DG set as per existing complete all as specified and directed.
281S&F in replacement start/ stop relay card 12 v / 24 v of suitable size for DG set complete all as specfied and directed.
282S&F in replacement stainless steel DG set door lock of required size complete all as specfied and directed.
283S&F in replacement head gasket kit suitable for DG set of various capacity as per sample complete all as specified and directed.
284Deduct Schedule of credit (calculation will be done off line) Rs. 92087.00