}

Tender For Electrification Of Proposed Gopuram , Existing Pathayappura And Area Lighting At Vermanur Temple, guruvayur-Kerala

Guruvayur Devaswom has published Tender For Electrification Of Proposed Gopuram , Existing Pathayappura And Area Lighting At Vermanur Temple. Submission Date for this Tender is 12-12-2023. Electrification Work Tenders in guruvayur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40931480
Tender For Electrification Of Proposed Gopuram , Existing Pathayappura And Area Lighting At Vermanur Temple
Tender
Indian
Kerala
Guruvayur
12-12-2023

Tender Details

Tender For Electrification Of Proposed Gopuram , Existing Pathayappura And Area Lighting At Vermanur Temple; 1 1 Elecrtification 2 90.2.1.1Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm Withspecials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Typemetal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Controllight Point With 6A, Plate Ceiling Rose - Short Point 3 90.2.1.3Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Includingproviding Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In Theswitch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Controllight Point Without Ceiling Rose - Short Point 4 90.2.1.4Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Includingproviding Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of Thebox Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point 5 90.2.1.6Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Includingproviding Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of Thebox Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Combinedplug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A, Switch In The Same Switch Board As That Of Light Points 6 90.2.1.7Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm Withspecials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Includingproviding Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Ofcopper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Typemetal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Spswitches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In Theswitch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of Thebox Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Independentplug - Short Point 7 90.3.20.3Supply & Installation Of Light Fittings On Tw Round Block Supply, Conveyance Installation Testing Andcommissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With Allaccessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit Thefitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wireconforming To Relevant Iss And Giving Connections As Required.1200 Mm 1X20w Led Lamp With Box Typefixture 8 90.12.5.1Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of1.1Kv Grade Of The Following Sizes In The Existing Rcc / Hume / Stone Ware / Gi / Dwc Pipe Asrequired.2 Core 4 Sq Mm 9 90.12.5.2Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of1.1Kv Grade Of The Following Sizes In The Existing Rcc / Hume / Stone Ware / Gi / Dwc Pipe Asrequired.2 Core 6 Sq Mm 10 90.12.7.1Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clampsnot Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 4 Sq Mm Withfactory Made Clamp 11 90.12.7.2Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clampsnot Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 6 Sq Mm Withfactory Made Clamp 12 9.1.1Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Followingsize Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade Asrequired.2 X 6 Sq. Mm ( 19Mm ) 13 Od40458 / 2023_2024Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 2 X 4 Sq. Mm 14 90.6.10.1Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recessincluding Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required 20 Mm 15 1.17.2Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Theexisting Surface / Recessed Steel / Pvc Conduit As Required.2 X 1.5 Sq. Mm 16 1.17.11Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Theexisting Surface / Recessed Steel / Pvc Conduit As Required.2 X 2.5 Sq. Mm 17 1.24.1Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Boxincluding Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 18 1.24.3Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Boxincluding Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 19 1.24.4Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Boxincluding Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 20 1.24.5Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Boxincluding Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 21 1.33Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Blockincludingconnection Etc As Required. 22 1.27.2Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modularswitches In Recess Etc As Required.3 Module ( 100Mmx75mm ) 23 1.27.5Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modularswitches In Recess Etc As Required.8 Module ( 125Mmx125mm ) 24 1.22.3Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Sizeof Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required.150 Mm X 75 Mm X 60 Mmdeep 25 90.16.1.1Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Givingconnection As Required2.00 Mm Copper Conductor ( 14 Swg ) 26 90.16.1.2Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Givingconnection As Required2.65 Mm Copper Conductor ( 12 Swg ) 27 90.16.5.1Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimpingetc. As Required.2.00 Mm ( 14 Swg ) 28 90.16.5.2Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimpingetc. As Required.2.65 Mm ( 12 Swg ) 29 90.12.9.2Supplying, Laying And Jointing Of The Following Sizes Of Double Wall Corrugated ( Dwc ) Pipes Made Out Ofhdpe Conforming To Is 14930 Part Ii For Mechanical Protection To Underground Power Cables With Allrequired Accessories In Ground In The Existing Trench50 / 38 Mm Or Nearest Size 30 Od29494 / 2023_2024Supply Installation Testing And Commissioning Of Led Flood Light Fitting 60W With Efficacy Upto150lm / W, Surge Protection 10Kv, Ip68 For Led Chamber And Ip67 For Driver Compartment, 5 Years Warrantyled Chip Make Cree / Lumilled / Nichia Power Factor 0.9 And Giving Connection.Lm 79&80 Certificates To Beproduced. ( Aston Prime K-Lite Id 4200 / Equivalent ) 31 14.10Providing And Laying In Position Reinforced Cement Concrete 1 :2:4 ( 1 Cement : 2 Coarse Sand : 4 Gradedstone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. Asrequired ( Excluding Reinforcement ) . 32 14.12Providing 15Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement : 4 Fine Sand ) At All Levels. 33 14.13.1Providing, Laying And Fixing Following Dia G.I. Pipe ( Medium Class ) In Ground Complete With G.I. Fittingsincluding Trenching ( 75 Cm Deep ) And Re-Filling Etc As Required 50 Mm Dia 34 90.3.21.3Supply & Installation Of Light Fittings On C / U Shaped Flat Iron Bracket Supply, Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From 0.5Mm Crca Sheet Completewith All Accessories And Lamps Etc. Directly On Wall Using 2 Nos. C / U Brackets Made From 20 X 3 Mm Msflat, Painting The Flat Iron Bracket And Giving Connections With Required Length Of 16 / 0.20Mm 3 Core Copperconductor Flex Wire Conforming To Relevant Iss Or Extending The Original Wiring And Giving Connection Etc.As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture 35 Od37906 / 2023_2024Supply, Conveyance, Installation, Testing And Cmmissioning Of Ceiling Fan Of All Sizes Using Standardaccessories Including Wiring The Down Rod With 16 / 0.20Mm Pvc Insulated And Pvc Sheathed 650 / 1100Vgrade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mmsweep 5 Star Rated 26 / 28W At Maximum Speed Bldc Ceiling Fan With Service Value Greater Than Or Equalto 6 Complete With 260Mm Down Rod , Canopies, Shackeles And Blades Working On 230V / 240V Singlephase A / C. 36 1.58Supplying And Fixing Pvc Batten / Angle Holder Including Connection Etc. As Required. 37 Od31457 / 2023_2024Supply And Providing 200Mm Plastic Shade In The Exsisting Batta Holder As Required. 38 Od31458 / 2023_2024Supply And Providing 7 / 9W Led Bulb In The Exsisting Battan / Bulkhead Fitting As Required. 39 Od31459 / 2023_2024Supply Installation Testing And Commissioning Of 35W Led Street Light Fitting With Ip66protection, 120Lm / W, Pf>0.95 Thd<10% Pressure Die Cast Aluminium Body, Pc Lens For Optium Lightspread, Potted Driver, Life 50000@L70 On Exsisting Gi Pipe And Giving Connection.Lm79&80 Certificates Tobe Produced Mentioning Chip Manufacturer. ( Wipro Dot Lr08 / Equivalent 40 Od31460 / 2023_2024Supply Installation Testing And Commissioning Of Led Flood Light Fitting 2X60w With Efficacy Upto150lm / W, Surge Protection 10Kv, Ip68 For Led Chamber And Ip67 For Driver Compartment, 5 Years Warrantyled Chip Make Cree / Lumilled / Nichia Power Factor 0.9 And Giving Connection.Lm 79&80 Certificates To Beproduced. ( Aston Prime K-Lite Id 4201 / Equivalent ) 41 2.3.1Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator6way, Double Door 42 2.3.3Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator12way, Double Door 43 2.10.1Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breakersuitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testingand Commissioning Etc. As Required.Single Pole 44 2.10.3Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breakersuitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testingand Commissioning Etc. As Required.Double Pole 45 2.12.1Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Completewith Connections, Testing And Commissioning Etc. As Required.40 Amps 46 2.11Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 47 2.14.1Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Currentcircuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required.25 Amps

Key Value

Document Fees
INR 500 /-
EMD
INR 5200.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail