Tender For Provision Of Fire Hydrant System For Sre Atcr-33 S Radar System And Emergency Exit At Af Stn Agra., agra-Uttar Pradesh

Military Engineer Services has published Tender For Provision Of Fire Hydrant System For Sre Atcr-33 S Radar System And Emergency Exit At Af Stn Agra.. Submission Date for this Tender is 30-12-2023. Pump House Construction Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40930260
Corrigendum : Tender For Provision Of Fire Hydrant System For Sre Atcr-33 S Radar System And Emergency Exit At Af Stn Agra.
Open Tender
Indian
Uttar Pradesh
Agra
30-12-2023

Tender Details

Tender For Provision Of Fire Hydrant System For Sre Atcr-33 S Radar System And Emergency Exit At Af Stn Agra.; 1 Schedule A Part I ( Building Works ) To Be Quoted By The Tenderer In Boq 2 Provn Of Emergency Exit Staircase For Sre Bldg With Permanent Specifiction Complete All As Specified& Directed And Shown In Drawings. 3 Construction Of Pump House With Permanent Specifiction Complete All As Specified& Directed And Shown In Drawings. 4 Construction Of Rcc Under Ground Sump 150000 Ltr Capacity With All Fittings And Fixtures Complete Including Excavation, Removal, Form Work Etc Complete All As Specified& Directedand Shown In Drawings . 5 Schedule A Part Ii ( Site Clearance, Excavation & Earthwork ) 6 Lump Sum Price Worked Out By The Contractor For Site Clearance, Excavation & Earthwork As Listed In Sch A Part -Ii 7 Schedule A Part Iii ( Internal Water Supply ) 8 Lump Sum Price Worked Out By The Contractor For Internal Water Supply As Listed In Sch A Part -Iii 9 Schedule A Part Iv ( Internal Electrification ) 10 Lump Sum Price Worked Out By The Contractor For Internal Electrification ) As Listed In Sch A Part -Iv 11 Schedule A Part V ( Road / Path / Hardstnding ) . 12 Lump Sum Price Worked Out By The Contractor For Road / Path / Culverts / Hardstnding As Listed In Sch A Part -V 13 Schedule A Part Vi ( Sewage Disposal ) . 14 Lump Sum Price Worked Out By The Contractor For Sewage Disposal As Listed In Sch A Part -Vi 15 Schedule A Part Vii ( Miscellaneous Items Of B&R And E&M ) Note: To Be Quoted By The Tenderer In Boq . 16 Fire Pumps And Accessories 17 Supplying, Installation, Testing And Commissioning Of Electrical Motor Driven Main Pump Of Horizontal Centrifugal End Suction Top Discharged Type With Mechanical Seal And Capable To Deliver 2850 Lpm At 70 Mtrs. Head, With All Necessary Accessories Like Bronze Impeller, Stainless Steel Shaft Along With Coupling Guard Andbase Plate For Pump, Fabricated Mild Steel Channel, Foundation Bolts, And Pump Should Have The Dry Run Sensor Provision, Etc., As Per Local Fire Brigade Requirement . The Pump Shall Capable To Have 3.5 Kg / Cm² Residual Pressure At Top Most Hydrant Point. The Pump Shall Be Coupled To Suitable Electrical Motor With Speed Of 2900 Rpm, Electric Supply 415V, 50 Hzand Complete Set Shall Be Mounted On A Common Base Frame With Anti Vibration Pad. The Quoted Rate Shall Includes Providing & Fixing Of Coupling, Coupling Guard And Foundation And Required Bolts Etc Complete All As Specified And As Directed. 18 Supplying, Installation, Testing And Commissioning Of Diesel Engine Driven Common Fire Pump Of Horizontal Centrifugal End Suction Top Discharged Type With Mechanical Seal And Capable To Deliver 2850 Lpm At 70 Mtrs. Head, With All Necessary Accessories Like Bronze Impeller, Stainless Steel Shaft , Fabricated Mild Steel Channel Withfoundation Bolts Etc., It Includes Providingandfixing Fuel Oil Tank Of Suitable Capacitywith Supports And Necessary Pipe Works For Diesel Engine, Battery And Battery Charger To Be Connected To Control Panel Of Diesel Engine And Exhaust Silencer Including Necessary Pipe Work And Lagging, Pump Should Have The Dry Run Sensor Provision, Etc., And Shall Be Automatic In Operation With Diesel Engine Controldiesel Engine Control Panel With 24V Dc Storage Battery 150 Amp - Hour Rating ( 2 Nos. Of 12Volts ) & Its Battery Charger, Cooling Water Line For Engine With Required Pipes / Valves / Fittings Etc., As Per Tacincluding All Associated Electricalworks. The Pump Shall Capable To Have 3.5 Kg / Cm² Residual Pressure At Top Most Hydrant Point. The Pump Shall Coupled Todiesel Engine, Radiator Water Cooled Type With Speed Of 1800Rpm And Complete Set Shall Be Mounted On Common Base Frame With Anti Vibration Pad. Batteries & Battery Leads With Stand, Fuel Tank For 2Hrs. Operation With Stand & Gauge Glass, Fuel Piping With Valves Etc Complete All As Direccted. Note: The Quoted Rate Shall Includes Radiator Water Cooling Piping ( If Required ) Coupling Guard And Other Standard Accessories And Foundation Bolts, Etc. Complete. 19 Supplying, Installation, Testing And Commissioning Of Electrical Motor Driven Jockey Pump Of Horizontal Centrifugal End Suction Top Discharged Type With Mechanical Seal And Capable To Deliver 180 Lpm At 70 Mtrs. Head, With All Necessaryaccessories Like Bronze Impeller, Stainless Steel Shaft Along With Pump Should Have The Dry Run Sensor Provision Etc. And Shall Be Automatic In Operation.The Pump Shall Be Coupled Tosuitable Motor With Speed Of 2900Rpm And Complete Set Shall Be Mounted On Common Base Frame With Anti Vibration Pad Etc Complete All As Directed.Note: The Quoted Rate Shall Includes Providing & Fixing Of Coupling, Coupling Guard And Foundation Bolts Etc. Complete All As Specified And Directed. 20 M & L For Installation, Testing And Commissioning Of 150Mm Dia Bore Ms B Class Exhaust Pipe With All Accessories & 100Mm Fibreglass Wool With Gi Hexagonal Wire Netting Of 3 / 4 Gauge 24 Swg With 24 Gauge Cladding Etc Complete All As Specified And Directed. 21 Supplying, Installing, Testing And Commissioning Ofg.I. Pipes Conforming To Is:1239 Pt - I Heavy Grade Class-C And Is:3589 Gr 410 Erw Pipe ( Min 6Mm Thick ) With Suitable Type Of Supports ( Shall Be Fabricated By M.S. Channel / Angle / Flat For Above 50Mm Dia ) , Anchor Fasteners, Bolt, Nuts, Clamps, U Bolts, Pipe Fittings Such As Reducers, Tees, Elbows, Flanges. Including Cutting, Grooving, Welding, Fixing In / On Walls, Ceiling By Using Suitable Supports Etc, With Paintingas Po Red As Per Shade 536 Of Is:5 For Above Ground Piping In Pump Room Complete All As Specified And Directed For Following Sizes :- 22 ( A ) 200 Mm Dia Bore 23 ( B ) 150 Mm Dia Bore 24 ( C ) 80 Mm Dia Bore 25 ( D ) 65 Mm Dia Bore 26 Supplying, Installing, Testing And Commissioningof Cast Iron Butterflyvalves Of Pn 1.6 Rating, Wafer Type, Following Dia Including Necessary Flanges, Nut, Bolt, Washer & Gaskets Etc. Complete All As Specified And Directed For Following Sizes :- 27 ( A ) 200 Mm Dia Bore 28 ( B ) 80 Mm Dia Bore 29 Supplying, Installing, Testing And Commissioningof Cast Iron Y Type Strainer Of Pn 1.6 Rating, Following Dia Including Necessary Flanges, Nut, Bolt, Washer & Gaskets Etc. Complete All As Specified And Directed For Following Sizes :- 30 ( A ) 200 Mm Dia 31 ( B ) 80 Mm Dia 32 Supplying, Installing, Testing And Commissioningof Cast Iron Butterflyvalves Of Pn 1.6 Rating, Wafer Type, Following Dia Including Necessary Flanges, Nut, Bolt, Washer & Gaskets Etc. Complete All As Specified And Directed For Following Sizes :- 33 ( A ) 150 Mm Dia Bore 34 ( A ) 65 Mm Dia Bore 35 Supplying, Installing, Testing And Commissioningof Cast Iron Non Return Valve Of Pn1.6 With Following Dia Including Necessary Flanges, Nut, Bolt, Washer & Gaskets Etc. Complete All As Specified And Directed For Following Sizes :- 36 ( A ) 150 Mm Dia Bore 37 ( A ) 65 Mm Dia Bore 38 Supplying, Installing, Testing And Commissioningof Rubber Expansion Bellows Of Pn 1.6 With Following Dia Including Necessary Flanges, Nut, Bolt, Washer & Gaskets Etc. Complete All As Specified And Directed For Following Sizes :- 39 ( A ) 150 Mm Dia Bore 40 ( A ) 65 Mm Dia Bore 41 Supplying , Installing, Testing And Commissioningof Pressure Switches Ofrange ( 0 To 10Kg / Sqcm ) Complete With 15Mm Dia Ball Valve For Isolation Complete All As Specified And Directed. 42 Supplying , Installing, Testing And Commissioningof Pressure Gauge 150Mm Dia Ofrange ( 0 To 16Kg / Sqcm ) Complete With 15Mm Dia Ball Valve For Isolation Complete All As Specified And Directed.. 43 Supplying, Installing, Testing And Commissioningof Ms Fabricated Air Vessel, Dished End At Pump Room About300mm Diaand 1000 Mm Height On Ms Stand With Necessary Cut Off Drain And Air Releasearrangements And Leading The Drain Pipe To The Sump At Pump Room Complete All As Specified And Directed.. 44 Supplying, Installing, Testing And Commissioning Of Control Panel Cpri Tested Metal Clad Type Made Out Of 2.0 Mm Thick Ms Sheet Factory Made And Powder Coated Suitable For 415 V Ac Three Phase, 4 Wires, 50 Hz Supply System. The Panel Shall Be Suitable For Automatic Operation Of The Fire Pumps As Per The Specified Parameters. The Panel Shall Be Completely Compartmentalised And Complete With Relays, Contactors, Starters, Copper Busbars, Designationa Labels As Per Requirement, Continuous Earth Bar, Panel Separators, Protective Screens, Cable Clamping Support System, Top / Bottom Cable Gland Plates For Incoming And Outgoing Cable Entries As Per Details Given Below:-Incoming400 A, 35Ka, Fp Mccb With Rotary Handles- 01 No.Busbarsa Set Of 600 A, 415V, 50Hz, 3 Ph, 4 Wire Copper Busbars.Instuments For Incomera Set Of Instrumentation With A Set Of Current Transformer 250 / 5A With Ammeter 0-250 A, Selector Switch, Voltmeter 0-500V With Selector Switch And A Set Of Phase Ryb Indicating Lights With Hrc Fuses.Provisions For Bms Connectivity. The Panel Should Have Sufficient No. Of Potential Free Contacts For Connectivity With Building Management System For Monitoring Purposes. 45 To Be Continue In Boq Item No 7.38Instruments On Outgoingsa Set Of Instrumentation With Ammeter With Selector Switch And Current Transformer For Each Pump.Indication Lights For On-Off Indication For Each Fire Pump.Outgoing Feedersfor Hydrant Pump200a Tp 25Ka Mccb With Rotary Handle, 75Hp Star-Delta Starter, Overload Relay, Single Phase Preventer, Timer Etc-01 No.For Jockey Pump25a Tp 25 Ka Mccb With Rotary Handle, 75 Hp Star-Delta Starter, Overload Relay, Single Phase Preventer, Timer Etc-01 No.For Diesel Engine Operated Pumpamf Logic Control For Auto Starting Of Diesel Engine Operated Pump When The Electric Driven Pumps Fail To Start. The Control Cubical Shall Consist Of Mcbs 12 / 24V Battery Charger, Dc Ammeter And Voltmeters, Indicating Lights, Push Buttons, Hooter, Lackout Timers, Interlocking Relay, Fuel Level Indicators Etc. As Required.Control Wiring With Suitable Size Of Copper Wirescontrol Wiring, Auxiliary Switches And Timer For Automatic Starting And Stopping Of Jockey Pump Shall Start When The Pressure Falls To 6.0 Kg / Sq Cm And Stops At 7.0 Kg / Sqcm Pressure And Main Fire Pump Shall Start When The Pressure Drops Below 5.5 Kg / Sqcm And Stops When The Pressure Builds Above 7.0Kg / Sqcm. Jockey Pump Shall Stop When The Main Pump Is Working. Suitable Timers Shall Be Used For Starting And Stopping Of The Pumps Operation Including Interconnecting Power Cabling For Mains To Panel And Panel To Pumps Etc. Of Suitable Size Complete All As Specified And Directed. 46 Supplying , Installing, Testing And Commissioning Of Fire Brigade Draw Out Connection From Tank With 100 Mm Dia Mild Steel C Class Pipe With Suitable Type Of Supports ( Shall Be Fabricated By M.S. Channel / Angle / Flat ) , Anchor Fasteners, Bolt, Nuts, Clamps, U Bolts, Pipe Fittings Such As Reducers, Tees, Elbows, Flanges Including Cutting, Grooving, Welding, Fixing In / On Walls, Ceiling By Using Suitable Supports Etc Complete All As Specified And Directed. 47 Supplying& Installing, Testing And Commissioning Of Non Return Sluice Valve Of Size 100Mm Dia For Fixing Infire Brigade Draw Out Connection From Tank Complete All As Specified And Directed 48 Supplying , Installing, Testing And Commissioning Of Frls, Pvc Insulated Pvc Sheathed, Steel Armoured, Aluminium Conductor, 1100 V Grade Power Cables Complete All As Specified. The Cables Shall Be Laid In Tray / Hume Pipe / In Trenches / On Walls / Floor Etc For Following Size :- 49 ( A ) 3 Core X 95 Sqmm Frls, Aluminium Armoured Cable For Main Pump 50 ( B ) 3 Core X 10 Sqmm Frls, Aluminium Armoured Cable For Jockey Pump 51 Supplying , Installing, Testing And Commissioning Of Frls, Pvc Insulated Pvc Sheathed, Steel Armoured, Copper Conductor, 1100 V Grade Power Cablescomplete All As Specified.The Cables Shall Be Laid In Tray / Hume Pipe / In Trenches / On Walls / Floor Etc. For Following Size :- 52 ( A ) 12 Core X 2.5 Sqmm Frls, Copper Armoured Cable For Diesel Pump 53 ( B ) 2 Core X 1.5 Sqmmfrls, Copper Armoured Cable For Instrumentation 54 Supplying , Installing, Testing And Commissioning Of Cable Xlpeinsulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire , Armoured Heavy Duty Electric Under Ground Lt Cable 1100 Volts Grade With Stranded Aluminium Conductor Of Size 120 Sqmm 3.5 Core Complete All As Specified.Note:The Cables Shall Be Laid In Tray / Hume Pipe / In Trenches / On Walls / Floor Etc.As Directed. 55 Supplying & Installing Of Perforated G.I.Sheet Cable Tray Of Size 200Mm X 50Mm And 1.6Mm Thick With Neccessory Angle Iron Suspension Supports, Anchor Fasteners Etc. Complete All As Directed. 56 Material & Labour For Earthing With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6.00Mm Thick Burried Directly In Ground Vertically At A Depth Not Less Than 2.25 Metre Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Metre Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Using Galvanised Iron Strip Of 32 X 6 Mm As Earthin Lead ( Upto The Body Of The Equipment ) By Means Of Bolts, Nuts, Check Nuts And Washers Made Of Galvanised Iron And Thimbles And Protected By Medium 40 Mm Dia Gi Pipeconnected To Main Switch Board Or Main Control Board Or Equipment And Gi Pipe Medium Grade 20Mm Bore For Watering And Including Funnel, Wire Mesh, 40Mm Thick Rcc Pit Cover Reinforcedwith 8Mm Dia Tmt Bar At 75C / C Both Ways And Lifting Arrangement By Providing Handles ( 02 Nos ) Of 12Mm Dia Ms Round Bar And Pcc Chamber Pit With Pcc ( 1:3:6 ) Type C-1 ( Using 20Mm Graded Stone Aggregate ) Including Excavation And Earth Work In Soft / Loose Soil, Returning, Filling In With Excavated Soil And Disposal Of Surplus Spoil To A Distance Not Exceeding 50M And Shown In Electrical Plate No 3 Of Ssr 2009 ( Part-I ) Complete All As Specified And Directed. 57 Supplying & Installing Of Earth Continuity Copper Conductor Or Main Earthing Lead 32Mm X 6Mm Thick, Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc Complete All As Specified And Directed. 58 Material And Labour For Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 59 Fire Hydrant System 60 Supplying, Installing, Testing And Commissioning Ofg.I. Pipes Conforming To Is 1239 Pt – I Heavy Grade Class-C For 25Mm Dia To 150Mm Dia And Is:3589 Gr. 410, Min 6Mm Thick Forabove 150Mm Dia With Suitable Type Of Supports ( Shall Be Fabricated By M.S. Channel / Angle / Flat ) , Anchor Fasteners, Bolt, Nuts, Clamps, U Bolts, Pipe Fittings Such As Reducers, Tees, Elbows, Flanges. Including Cutting, Grooving, Welding, Fixing In / On Walls, Ceiling By Using Suitable Supports Etc, As Per Drawings. 4 Mm Thick Polymeric Corrossion Protection Tape Conforming To Is 10221 And Painting With Bituminous Paint After Laying And Testing To 13.5 Kg / Sq. Cm Hydraulic Pressure After Installation Etc As Per Specification Complete Forthe Following Size :- 61 ( A ) 150 Mm Dia Bore 62 ( A ) 100 Mm Dia Bore 63 Supplying, Installing, Testing And Commissioning Of Hume Pipe 250Mm Dia For Under Ground Pipe Np3 With Collar & Accessories Complete All As Specified An Direcred. 64 Supplying, Installing, Testing And Commissioning Of Stainless Steel Single Hydrant Valve 63 Mm Dia As Per Is 5290, With 80 Mm Dia Flanged Inlet , Blank Caps , Chain And Hand Wheels & Necessary Nut, Bolt, Washer & Gaskets Etc With 1.5 M Heightyard Hydrant Of Gi 80Mm Dia Both End Flanged Complete All As Specified And Direcred.. 65 Supplying, Installing, Testing And Commissioning Of Rrl Hose Pipe Of 15 Mtrs. Long 63Mm Dia, Conforming To Is 636 Type A With Instantaneous Stainless Steel Couplings Complete All As Specified And Directed 66 Supplying, Installing, Testing And Commissioning Of Stainless Steel Branch Pipe , 63Mm Dia Instantaneouspattern Inlet And With 20 Mm Dia Nozzle Conforming To Is 903, Suitable For Inter Connectionto Hose Pipe Coupling Complete All As Directed. 67 Supplying & Installing Of Ms Cabinet ( Outdoor Type ) Of Size 800X600x250mm, 16 Gauge Thickness Havingcentral Openingand 4 Mmthick Glazedglass Doors ( Two Nos. ) Suitably Marked “Fire” On The Outside Complete All As Specified And Direcred. 68 Supplying, Installing, Testing And Commissioningof 4 Way Fire Brigade Inlet Connection Including Non Return Butterfly Valve 150Mm Dia Including Necessary Flanges, Nut, Bolt, Washer & Gaskets Etc. Complete All As Directed. 69 Supplying , Installing, Testing And Commissioning Of Gun Metal 25 Mm Dia, Air Release Valve With 25 Mm Dia Forged Brass Ball Valve With All Necessaries Complete All As Directed. 70 Supplying, Installing, Testing And Commissioning Of Stainless Steel Single Hydrant Valve As Per Is 5290, With 63 Mm Dia Instantaneous Outlet Of 80 Mm Dia Flanged Inlet , Blank Caps , Chain And Hand Wheels & Necessary Nut, Bolt, Washer & Gaskets Etc. Complete All As Directed. 71 Supplying & Installing, Of First Aid Hose Reel Drum Of 180° Swinging Type With 19Mm Dia Rubber Braided Hose Of 36M. Length With Ball Valve And 6Mm Diameter Shut Off Nozzle, Hose Reel Shall Conforming To Is 884 Complete All As Specified An Direcred. 72 Supplying & Installing Of Ms Cabinet ( Indoor Type ) Of Size 800X600x250mm, 16 Gauge Thickness Havingcentral Openingand 4 Mmthick Glazedglass Doors ( Two Nos. ) Painted Fire Red Out Side And Brilliant White Inside Yard, Suitably Marked “Fire” On The Outside Complete All As Specified An Direcred. 73 Supply And Fixing Ceiling Fans Complete With Blades, Down Rods, Electronic Regulator And Accessories, 230 V, 1200 Mm Sweep. Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current Motor ( Bldc ) Including Making Connections Complete All As Specified And Directed. 74 Supply And Fix Exhaust Fan, Steel Body Ac Single Phase. 230V Of Size 300Mm Sweep With, Blades, And Frame And Louvers Including Making Connections Complete All As Specified And Directed. 75 S&F Surface / Wall Mountingled Batten, Extruded Aluminium Housing Provided For Efficient Heat Dissipation With Poly Carbonate Diffuser & Intergrated Electronic Driver Including 20 Watt Led Including Making Connections Complete Fitting As Specified And Directed 76 S&F Surface / Wall Mounting10 Watt Led Batten With Inbuilt Smart Sensor Auto Dimmable Powder Coated Extruded Aluminium Housing Provided For Efficient Heat Dissipation With Poly Carbonate Diffuser & Intergrated Electronic Driverincluding Making Connections Complete As Specified And Directed 77 M&L For Provision Of Sub Main Wiring With Two Runs Of Single Core Frls Pvc Insulated, Unsheathed, Mutistranded Copper Conductor Cable Of Size 4.0 Sqmm Drawn In And Including Pvc Rigid Conduit Not Less Than 20Mm Dia With Its Accessories, Surface Type, Including One Run Of Single Core Fr Pvc Insulated, Unsheathed, Mutistranded Copper Conductor Cable Of Size 4.0 Sqmm As Earth Continuity And Connected Of Common Earth Dolly Complete All As Specified & Directed. Note:- Two Runs Of 4.0 Sqmm Cable & One Run Of 4.0 Sqmm Cable Alongwith Pvc Conduit Including Its Accessories Shall Be Measured And Paid One Unit Length Complete All As Specified And Directed. . 78 Supply And Laying Or Fixing Or Passing Through Pipe, 1100 Volts Grade Heavy Duty Cable With Pvc Insulated Aluminium Conductor Served With An Inner Sheathing Of Pvc Tape Armoured With Galvanised Steel Wire Or Tape And Overall Pvc Sheathed 4 Sqmm Nominal Cross Section In Service Connections Complete All As Specified And Directed. 79 S&F 1.50 Mtr Long House Service Bracket, Made Out Of 32Mm Dia Light Grade Gi Pipe, Bent To Shape Including Ms Hook & Stay Or Guy And Fixed To Wall / Poles Including All Necessary Nut / Bolts Complete All As Specified And Directed. 80 Material & Labour For Earthing With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6.00Mm Thick Burried Directly In Ground Vertically At A Depth Not Less Than 2.25 Metre Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Metre Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Using Gi Wire 4 Sqmm As Earthin Lead ( Upto The Body Of The Equipment ) By Means Of Bolts, Nuts, Check Nuts And Washers Made Of Galvanised Iron And Thimbles And Protected By Medium 40 Mm Dia Gi Pipeconnected To Main Switch Board Or Main Control Board Or Equipment And Gi Pipe Medium Grade 20Mm Bore For Watering And Including Funnel, Wire Mesh, 40Mm Thick Rcc Pit Cover Reinforcedwith 8Mm Dia Tmt Bar At 75C / C Both Ways And Lifting Arrangement By Providing Handles ( 02 Nos ) Of 12Mm Dia Ms Round Bar And Pcc Chamber Pit With Pcc ( 1:3:6 ) Type C-1 ( Using 20Mm Graded Stone Aggregate ) Including Excavation And Earth Work In Soft / Loose Soil, Returning, Filling In With Excavated Soil And Disposal Of Surplus Spoil To A Distance Not Exceeding 50M And Shown In Electrical Plate No 3 Of Ssr 2009 ( Part-I ) Complete All As Specified And Directed. 81 Supply And Fixing Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Including Making Connections Complete All As Specified And Directed. 82 Supply And Fixing Exhaust Fan, Steel Body Ac Single Phase 230V Of Size 380Mm Sweep With Blades And Frame And Louvers Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 18-12-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-12-2023
2 25-12-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-12-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 136400.0 /-
Tender Value
INR 74.26 Lakhs /-
Disclaimer :