}

Tender For Supply Ofmaterial, Design, Erection, Testing, Commissioning, Forshiftingand Utility Relocation Plan Ofht/Lt Lines, Transformers Crossing Over/Falling Underunder Electrical Sub-Division, Hpsebl, Rait Under Electrical Division Hpsebl Shahpur.. ( , kangra-Himachal Pradesh

Himachal Pradesh State Electricity Board has published Tender For Supply Ofmaterial, Design, Erection, Testing, Commissioning, Forshiftingand Utility Relocation Plan Ofht/Lt Lines, Transformers Crossing Over/Falling Underunder Electrical Sub-Division, Hpsebl, Rait Under Electrical Division Hpsebl Shahpur.. ( . Submission Date for this Tender is 30-12-2023. Electrification Work Tenders in kangra Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40930238
Corrigendum : Tender For Supply Ofmaterial, Design, Erection, Testing, Commissioning, Forshiftingand Utility Relocation Plan Ofht/Lt Lines, Transformers Crossing Over/Falling Underunder Electrical Sub-Division, Hpsebl, Rait Under Electrical Division Hpsebl Shahpur.. (
Tender
Indian
Himachal Pradesh
Kangra
30-12-2023

Tender Details

Tender For Supply Ofmaterial, Design, Erection, Testing, Commissioning, Forshiftingand Utility Relocation Plan Ofht / Lt Lines, Transformers Crossing Over / Falling Underunder Electrical Sub-Division, Hpsebl, Rait Under Electrical Division Hpsebl Shahpur.. ( Seop-48 / 2023-24-11 Kv Ht Line 2 Prov. Conductor ( Aaac ) ( Including Cutting & Sagging ) 7 / 3.15Mm² ( 100Mm² ) 3 Prov. Gi Wire 8 Swg For Guarding 4 Prov. St Pole 9Mtr. Long W / L 200 Kg 5 Prov. Rcc Muff Of 2000 Mm Length 6 Prov. A.I. Knee Bracing Set 2X ( 750X50x50 ) Mm For Single Pole 7 Angle Iron For Earth Wire 1600X50x50mm 8 Angle Iron For Earth Wire 2500X50x50mm 9 Prov. C.I. / F.G. X-Arm ( 600X100x50 ) Mm For Single Go Switch Supporting Channel 10 Prov. C.I. / F.G. X-Arm ( 1500X100x50 ) Mm For Single Pole & Double Pole 11 Prov. C.I. X-Arm For Double Pole Structure ( 2400X100x50 ) Mm 12 Prov. A.I. Bracing Set For Double Pole Structure ( 1500X50x50 ) Mm & ( 2700X50x50 ) Mm. Each ( 2 No. Per Set ) 13 Prov. 11 Kv Pin Insulator With Pin Helically Formed Fitting 14 Prov. Disc Insulator Set ( Cleaves And Tong ) Helically Formed Fitting 15 Prov. Ht Stay Set Complete Including Guy Assembly & Helicallyfitting 16 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 17 Prov. G.O.Switch 400A 18 Prov. Ht Earthing For Pcc / Steel Pole 19 Prov. Danger Plate ( 250X200x1.6 Mm ) 20 Prov. M.S. Nuts And Bolts ( Off Sizes ) 21 Prov. Top Clamp For Pole ( M.S. Flat 50X6 Mm ) 22 Prov. Barbed Wire 23 Prov. Aluminium Paint 24 Prov. Back / Half Clamp ( M.S. Flat50x6 Mm ) 25 Prov. Full Clamp ( M.S. Flat 50X6 Mm ) 26 Prov. Eye Hook For Earth Wire 27 Erection Charges Complete In All Respect. 28 Transportation Charges Complete In All Respect. 29 Dimentlement Chargescomplete In All Respect. 30 Ht Metering 31 Prov. 11 Kv Ct Pt Unit 32 Prov. S / T Pole9mtr. W / L200 Kg 33 Prov. Rcc Muff Of 2000 Mm Length 34 Prov. C.I. X-Arm ( 100X50x6 Mm ) Length 2800 X 4Nos 35 Prov. C.I ( 100X50x6 Mm ) Length 460Mm X 2No For Supporting Main Channel Of Ct Pt Unit 36 Prov. Transformer Belting A.I ( 2800X50x50 Mm ) 37 Prov. Transformer Belting A.I ( 460X50x50 Mm ) 38 Prov. C.I. For Fuse Unit / Ab Switch ( 2800X75x40 Mm ) 39 Prov. A.I X Arm For Lightning Arrestor ( 2800X50x50 Mm ) & Ht Metering Box 40 Prov. G.O.Switch 400A 41 Prov. D.O.Fuse 42 Prov. Lightning Arrestors 43 Prov. Disc Insulator Fitting 44 Prov. Stay Set Complete 45 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 46 Prov. Pipe Earthing 47 Ht Energy Meter 11000 / 110V 48 Prov. Half Clamp ( M.S. Flat 50X6 Mm ) 49 Prov. Full Clamp ( M.S. Flat 50X6 Mm ) 50 Prov. M.S. Nuts And Bolts ( Off Sizes ) 51 Prov. Aluminium Thimble 52 Prov. Aluminium Thimble 53 Prov. Lead-Tin Solder ( 60:40 ) 54 Prov. Solder Flux 55 Prov. Danger Plate 56 Prov. Barbed Wire 57 Prov. Aluminium Paint. 58 Prov. Aaac 7 / 3.15Mm² Conductor For Earthing 59 Prov. Msci ( 600X100x50mm ) For Go Switch Supporting To Handle 60 Chain Link Fencing , Angle Iron , Gate Etc For Ct Pt Unit Fencing 61 Erection Charges Complete In All Respect. 62 Transportation Chargescomplete In All Respect. 63 Dimentlement Charges Complete In All Respect. 64 3-Phase Lt Line 65 Prov. ( Acsr ) Conductor ( Including Cutting & Sagging ) 7 / 3.15Mm² ( 50Mm² ) 66 Prov. G.Iwire 8 Swg For Earthwire 67 Prov. S / T Pole 8 Mtr. W / L 200Kg. 68 Prov. S / T Pole 9 Mtr. W / L 200Kg. 69 Prov. Rcc Muff Of 1800 Mm Length 70 Prov. Lt Cable ( 3.5 Core ) 120 Mm2 For T / F Common Pole 71 Prov. Aluminium Paint 72 Prov. A.I.X. Arm ( 75X75x6 ) ( Length 1.50 Meter ) 73 Prov. X-Arm Clamp 74 Prov. Eye Hook Bolt 75 Prov. Lt Stay Set 76 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 77 Prov. Shackle Insulator 78 Prov. D-Iron. 79 Prov. Gi Reel 80 Prov. Spriel Pvc Spacer 81 Prov. M.S. Nuts And Bolts ( Off Sizes ) 82 Erection Charges Complete In All Respect. 83 Transportation Charges Complete In All Respect. 84 Dimentlement Chargescomplete In All Respect. 85 100Kva S / Stn Airport 86 Prov. 11 / 0.4 Kv, 100 Kva Distribution Transformer 87 Prov. S / T Pole9mtr. W / L200 Kg 88 Prov. Rcc Muff Of 2000 Mm Length 89 Prov. C.I. X-Arm ( 100X50x6 Mm ) Length 2800 X 4Nos 90 Prov. C.I ( 100X50x6 Mm ) Length 460Mm X 2No For Supporting Main Channel Of Transformer 91 Prov. Transformer Belting A.I ( 2800X50x50 Mm ) 92 Prov. Transformer Belting A.I ( 460X50x50 Mm ) 93 Prov. Transformer Bed ( 1.2X1.5X1.5 M ) Plinth 94 Prov. C.I. For Fuse Unit / Ab Switch ( 2800X75x40 Mm ) 95 Prov. A.I X Arm For Lightning Arrestor ( 2800X50x50 Mm ) & Lt Distribution Box 96 Prov. G.O.Switch 400A 97 Prov. D.O.Fuse 98 Prov. Lightning Arrestors 99 Prov. Disc Insulator Fitting 100 Prov. Stay Set Complete 101 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 102 Prov. Pipe Earthing 103 Prov. Lt Distribution Panel Box With Mccb 100 Kva 104 Prov. Half Clamp ( M.S. Flat 50X6 Mm ) 105 Prov. Full Clamp ( M.S. Flat 50X6 Mm ) 106 Prov. M.S. Nuts And Bolts ( Off Sizes ) 107 Prov. Aluminium Thimble 108 Prov. Aluminium Thimble 109 Prov. Lead-Tin Solder ( 60:40 ) 110 Prov. Solder Flux 111 Prov. Danger Plate 112 Prov. Barbed Wire 113 Prov. Lt Cable ( 3.5 Core ) 120 Mm2 114 Prov. Energy Meter ( 3-Phase, 4-Wire ) 100-200 / 5 Act Type 115 Prov. Aluminium Paint. 116 Prov. Aaac 7 / 3.15Mm² Conductor For Earthing 117 Prov. Ai ( 750X50x50mm ) For Transformer Belting 118 Prov. Msci ( 600X100x50mm ) For Go Switch Supporting To Handle 119 Chain Link Fencing , Angle Iron , Gate Etc For Transformer Fencing 120 Erection Charges Complete In All Respect. 121 Transportation Charges Complete In All Respect. 122 Dimentlement Chargescomplete In All Respect. 123 100Kva Salangri 124 Prov. 11 / 0.4 Kv, 100 Kva Distribution Transformer 125 Prov. S / T Pole9mtr. W / L200 Kg 126 Prov. Rcc Muff Of 2000 Mm Length 127 Prov. C.I. X-Arm ( 100X50x6 Mm ) Length 2800 X 4Nos 128 Prov. C.I ( 100X50x6 Mm ) Length 460Mm X 2No For Supporting Main Channel Of Transformer 129 Prov. Transformer Belting A.I ( 2800X50x50 Mm ) 130 Prov. Transformer Belting A.I ( 460X50x50 Mm ) 131 Prov. Transformer Bed ( 1.2X1.5X1.5 M ) Plinth 132 Prov. C.I. For Fuse Unit / Ab Switch ( 2800X75x40 Mm ) 133 Prov. A.I X Arm For Lightning Arrestor ( 2800X50x50 Mm ) & Lt Distribution Box 134 Prov. G.O.Switch 400A 135 Prov. D.O.Fuse 136 Prov. Lightning Arrestors 137 Prov. Disc Insulator Fitting 138 Prov. Stay Set Complete 139 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 140 Prov. Pipe Earthing 141 Prov. Lt Distribution Panel Box With Mccb 100 Kva 142 Prov. Half Clamp ( M.S. Flat 50X6 Mm ) 143 Prov. Full Clamp ( M.S. Flat 50X6 Mm ) 144 Prov. M.S. Nuts And Bolts ( Off Sizes ) 145 Prov. Aluminium Thimble 146 Prov. Aluminium Thimble 147 Prov. Lead-Tin Solder ( 60:40 ) 148 Prov. Solder Flux 149 Prov. Danger Plate 150 Prov. Barbed Wire 151 Prov. Lt Cable ( 3.5 Core ) 120 Mm2 152 Prov. Energy Meter ( 3-Phase, 4-Wire ) 100-200 / 5 Act Type 153 Prov. Aluminium Paint. 154 Prov. Aaac 7 / 3.15Mm² Conductor For Earthing 155 Prov. Ai ( 750X50x50mm ) For Transformer Belting 156 Prov. Msci ( 600X100x50mm ) For Go Switch Supporting To Handle 157 Chain Link Fencing , Angle Iron , Gate Etc For Transformer Fencing 158 Erection Charges Complete In All Respect. 159 Transportation Charges Complete In All Respect. 160 Dimentlement Charges Complete In All Respect. 161 250Kva Gaggal 162 Prov. 11 / 0.4 Kv, 250 Kva Distribution Transformer 163 Prov. S / T Pole9mtr. W / L200 Kg 164 Prov. Rcc Muff Of 2000 Mm Length 165 Prov. C.I. X-Arm ( 100X50x6 Mm ) Length 2800 X 4Nos 166 Prov. Transformer Foundation ( 2.5X2.5X2.5 M ) Plinth 167 Prov. C.I. For Fuse Unit / Ab Switch ( 2800X75x40 Mm ) 168 Prov. A.I X Arm For Lightning Arrestor ( 2800X50x50 Mm ) & Lt Distribution Box 169 Prov. G.O.Switch 400A 170 Prov. D.O.Fuse 171 Prov. Lightning Arrestors 172 Prov. Disc Insulator Fitting 173 Prov. Stay Set Complete 174 Prov. Stay Wire 7 / 3.15 Mm ( @ 6.0 Kg Per Stay Set ) 175 Prov. Pipe Earthing 176 Prov. Lt Distribution Panel Box With Mccb 250 Kva 177 Prov. Half Clamp ( M.S. Flat 50X6 Mm ) 178 Prov. Full Clamp ( M.S. Flat 50X6 Mm ) 179 Prov. M.S. Nuts And Bolts ( Off Sizes ) 180 Prov. Aluminium Thimble 181 Prov. Aluminium Thimble 182 Prov. Lead-Tin Solder ( 60:40 ) 183 Prov. Solder Flux 184 Prov. Danger Plate 185 Prov. Barbed Wire 186 Prov. Lt Cable ( 3.5 Core ) 240 Mm2 187 Prov. Energy Meter ( 3-Phase, 4-Wire ) 300-400 / 5 Act Type 188 Prov. Aluminium Paint. 189 Prov. Aaac 7 / 3.15Mm² Conductor For Earthing 190 Prov. Ai ( 750X50x50mm ) For Transformer Belting 191 Prov. Msci ( 600X100x50mm ) For Go Switch Supporting To Handle 192 Chain Link Fencing , Angle Iron , Gate Etc For Transformer Fencing 193 Erection Charges Complete In All Respect. 194 Transportation Charges Complete In All Respect. 195 Dimentlement Charges Complete In All Respect. 196 Quantities Are Mentioned Above Are Tentative And Actual Quantity Shall Be Worked Out After Check Survey To Be Carried Out By The Successful Tender And Detailed Engineering And Finalization Of Tower Location Chart.Payment Shall Be Made As Per Approved Bill Of Material / Actual Quantities Measured At Site.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-12-2023 SEOP-48/2023-24 Date 15-12-2023
2 15-12-2023 seop-48/2023-24 (ii) Date 19-12-2023
3 19-12-2023 SEOP-48/2023-24 (III) Date 22-12-2023
4 22-12-2023 SEOP-44/2023-24 (IV) Date 26-12-2023
5 27-12-2023 SEOP-48/2023-24 (V) Date 30-12-2023

Key Value

Document Fees
INR 1180 /-
EMD
INR 40542.0 /-
Tender Value
INR 40.54 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail