Tender For Electrification For Augmentation/Rejuvenation/Restoration Of Neeri Wells/Ponds In Csir-Neeri, Nagpur., nagpur-Maharashtra

Council Of Scientific And Industrial Research-CSIR has published Tender For Electrification For Augmentation/Rejuvenation/Restoration Of Neeri Wells/Ponds In Csir-Neeri, Nagpur.. Submission Date for this Tender is 12-12-2023. Electrification Work Tenders in nagpur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

40929232
Tender For Electrification For Augmentation/Rejuvenation/Restoration Of Neeri Wells/Ponds In Csir-Neeri, Nagpur.
Open Tender
Indian
Maharashtra
nagpur
12-12-2023

Tender Details

Tender For Electrification For Augmentation / Rejuvenation / Restoration Of Neeri Wells / Ponds In Csir-Neeri, Nagpur.; 1 Supplying Armoured Cable 4 Core 10 Sq. Mm: Armoured Cable Of Xlpe Insulated ( Cross Linked Polyethylene ) Pvc Sheathed, Armoured With Galvanized Round / Strip Steel, 1100 V. Grade Conforming To I.S. 1554 ( Part-1 ) & Is: 7098 ( Part-1 ) , 4 Core 10 Sq. Mm. Stranded Aluminium Conductor. Contractor Should Submit Return Cable Test Report Duly Certified From Oem / Govt. Lab. Institute Before Installation. 2 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Cable Up To 35 Sq. Mm. Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Efilling The Trench Etc As Required. 3 Supplying And Laying Of 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. 4 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 4 X 10 Sq. Mm ( 25Mm ) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 5 Numbering Of Ceiling Fan / Exhaust Fan / Pump / Led Fittings With Painting As Required. 6 Sitc Of Open Well Submersible ( Horizontal Type ) Pump Set Of 3 Phasesupply, With A Head Range Of 12-18 M, Discharge Range Of Up To 320 Lpm, Motor Of Class B Insulation, 415 Volt, The Material Of The Body Is Ci / Ss, With 10-Meter Length Flat Submersible Cable Without Joint, With Parashot / Nylon Rope Of 10-16 Mm Dai. For Hanging The Motor, Required Dol Starter With An Indicator For Starting The Pump As Required And Warranty 2 Years. 7 Supply Of 6.5 Meter Height Street Tubular Pole Having Bottom Section Od Not Less Than 125 Mm And As Per Is Specification With 5Mm Thick Base Plate. Single Arm Bracket Of One Mtr. Length. The Pole Shall Have A Smooth Surface. The Pole Should Have Painted With Two Coats Of Red Oxide And Two Coats Of Silver Enamel Paintetc. As Required. 8 Supplying And Fixing 5 A To 32 A Rating, 240 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 9 Erection Metallic Pole : Erection Of Metallic Pole Of Above 4.5 Meter And Upto 6.5 Meter Length In Cement Concrete 1:3:6 ( 1 Cement; 3 Coarse Sand : 6 Gradedstone Aggregate 40 Mm Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required. 10 Supplying And Erecting Metal Box Of Size 250X200x100 Mm 18 Swg Thick Permanent Silver Colour With Din Rail, Bakelite Connector 4 Way Strip Having Locking Arrangement. Danger Notice Plate. Two Hinges At Top, Two Clamps With Nut Bolt And Spring Wisher, And Providing Gasket On Door, Sealing Of All Holes With Proper Materialetc. As Required. 11 P / F Street Light Luminaires 45 W: Providing And Fixing Street Light Fitting In The Existing Pole / Bracket, Fitting Shall Be Comprises Of Die Cast Aluminium Housing, Pipe Mounting Type With A Normal System Lumen Output Of 4500 Lumens. The Luminaire Shall Have A Rated System Lifetime Of 35000 Burning Hours. The Luminaire Shall Have High Efficiency Diffuser, Heat Resistance Toughened Glass. The Total Power Consumption Should Not Exceed 45 Watts, Operates On Voltage 150-240 V Etc. Complete With All Accessories, Ip 66 Protection For Optical Compartment With High Power Leds And Driver With Efficiency > 0.85, Optics Should Be Such That It Gives Uniform Distribution And Having Surge Protection Device Of 5 Kvetc. As Required. 12 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Three Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 13 P / F 6 Swg Gi Wire : Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 14 Supplying And Fixing Of Light Class G.I. Pipe Of 50 Mm Dia. ( Nominal ) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required.

Key Value

Document Fees
Refer document
EMD
INR 10200.0 /-
Tender Value
INR 5.07 Lakhs /-

BOQ Items

Name of Work:- Electrification for Augmentation/Rejuvenation/Restoration of NEERI Wells/Ponds in CSIR-NEERI, Nagpur.
Sl. No. Item Description
1Supplying armoured cable 4 core 10 Sq. mm: armoured cable of XLPE insulated (cross linked polyethylene) PVC sheathed, armoured with galvanized round / strip steel, 1100 V. grade conforming to I.S. 1554 (part-1) & IS: 7098 (part-1), 4 core 10 Sq. mm. stranded aluminium conductor. Contractor should submit return cable test report duly certified from OEM/ Govt. lab. Institute before installation.
2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of cable up to 35 Sq. mm. direct in ground including excavation, sand cushioning, protective covering and efilling the trench etc as required.
3Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
4Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 10 sq. mm (25mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
5Numbering of Ceiling fan/ Exhaust fan/ pump/ LED fittings with painting as required.
6SITC of Open well submersible (Horizontal Type) pump set of 3 Phasesupply, with a Head Range of 12-18 m, Discharge range of up to 320 LPM, motor of Class B insulation, 415 Volt, the material of the body is CI/SS, with 10-meter length flat submersible cable without joint, with parashot/nylon rope of 10-16 mm dai. for hanging the motor, required DOl starter with an indicator for starting the pump as required and Warranty 2 years.
7Supply of 6.5 Meter height street tubular pole having Bottom section OD not less than 125 mm and as per IS specification with 5mm thick base plate. Single arm bracket of one mtr. length. The pole shall have a smooth surface. The pole should have painted with two coats of red oxide and two coats of silver enamel paintetc. as required.
8Supplying and fixing 5 A to 32 A rating, 240 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9Erection metallic pole : Erection of metallic pole of above 4.5 meter and upto 6.5 meter length in cement concrete 1:3:6 (1 cement; 3 coarse sand : 6 gradedstone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
10Supplying and erecting metal box of size 250x200x100 mm 18 swg thick permanent silver colour with DIN rail, Bakelite connector 4 way strip having locking arrangement. Danger notice plate. Two hinges at top, Two clamps with nut bolt and spring wisher, and providing gasket on door, Sealing of all holes with proper materialetc. as required.
11P/F Street light luminaires 45 w: Providing and fixing Street light fitting in the existing pole/ bracket, fitting shall be comprises of die cast aluminium housing, pipe mounting type with a normal system lumen output of 4500 Lumens. The luminaire shall have a rated system lifetime of 35000 burning hours. The luminaire shall have high efficiency diffuser, heat resistance toughened glass. The total power consumption should not exceed 45 Watts, operates on voltage 150-240 V etc. complete with all accessories, IP 66 protection for optical compartment with high power LEDs and driver with efficiency > 0.85, optics should be such that it gives uniform distribution and having surge protection device of 5 kvetc. as required.
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Three poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
13P/F 6 SWG GI wire : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
14Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.