Border Security Force-BSF has published Tender For Repair And Maintenance Of Amf, Distribution Panels, Mfp And Sfp Of Bfl Panels Installed At Various Bops In Aor Of 156 Bn Bsf Under Shq Bsf Udaipur.. Submission Date for this Tender is 09-12-2023. Electrical Panel Tenders in udaipur Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing and fixing MCX22, 4 pole contactor, 100 amp in existing panel board including drilling holes in existing cubical panel, making connections including dismantling of defective contractor (Including deducting the cost of old scapped material) etc as reqd.make L&T code No,CS97017, frame size 4 or its compatible to Havells /Standard/Legrand/ABB/C&S. |
2 | Providing and fixing 160 amp MCCBs, 4 pole with breaking capacity 36 KA, 415 volts with suitable operating mechanism extended rotary handle and spreader terminal in existing cubical panel board including drilling holes in cubical panel, making connections (Including deducting the cost of old scapped material) etc as reqd.Make-L&T Cat No.CM98065OONO or its equivalent make ofHavells/Standard/ Legrand/ ABB/ C&S. |
3 | Providing and fixing 32 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixingin existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning etc as reqd. L&T make cat no.SK95703or its compatible to Havells/or its equivalent make ofHavells/Standard/ Legrand/ABB/C&S. |
4 | Providing and fixing 63 amps ,415 volt ,TPN Disconnector fuse switch unit open execution with suitable HRC fuse link,for fixingin existing SS enclosure with door interlock facility including dismantling of defective one, driliing holes complete with connections,tetsing, commisioning etc as reqd.L&T make cat no.SK95704 or its compatible to Havells/or its equivalent make of Havells/Standard/legrand.(including less of retrive/scrapped material, dismentle TPN disconnector fuse switch will not be taken back) |
5 | Providing and fixing 125 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixingin existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning (Including deducting the cost of old scapped material) etc as reqd. L&T make cat no.SK95001 or its compatible to Havells/or its equivalent make of Havells/ABB/Standard/Legrand. |
6 | Providing and fixing Combined Digitaltype display meter suitable for measuring Ac voltage, current, KWH, KW, PFFrequency etc having three line display3 phase multifunction meter in existing cubical panel board including, making connections (Including deducting the cost of old scapped material) etc as reqd. Make L&T code No.WL441010OOOO or its equivalent make of havells/ABB/seimens/Legrand/C&S. |
7 | Replacement of defective spare contact coil for 160 amp,240 volt MCX32, 4 pole contactor, making connections including dismantling of defective contractor kit(Including deducting the cost of old scapped material) etc as reqd.make L&T code No,CS94196 or its compatible to Havells/Standard/Legrand/C&S. |
8 | Supplying and making interconnections with following size of single core PVC insulated 1.1 KV grade copper conductor cable betweenswitch gears, bus bars etc of existing panel including providing suitable size cable lugs/ thimbles (Including deducting the cost of old scapped material) etc complete as required.(Finolex/Polycab /KEI /Havells/L&T).i)16 SQMM single core Heavy Duty copper cable. |
9 | Supplying and making interconnections with following size of single core PVC insulated 1.1 KV grade copper conductor cable betweenswitch gears, bus bars etc of existing panel including providing suitable size cable lugs/ thimbles (Including deducting the cost of old scapped material) etc complete as required.(Finolex/Polycab /KEI /Havells/L&T).ii)35 SQmm single core Heavy Duty copper cable. |
10 | Providing and fixing of 250 amps , 415 volt, Bolted fuse link suitable for 125 amps disconnector fuse unit, size A4 conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST30769 or its compatible to Havells/Standard/Legrand/Schneider . |
11 | Providing and fixing of 125 amps , 415 volt, Bolted fuse link suitable for 125 amps disconnector fuse unit, size A4 conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST30769 or its compatible to Havells/Standard/Legrand/Schneider . |
12 | Providing and fixing of 63 amps , 415 volt, Bolted fuse link suitable for 63 amps disconnector fuse unit, size A1L, conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST35828 or its compatible to Havells /Standard/Legrand/Schneider . |
13 | Providing and fixing of 32 amps , 415 volt, Bolted fuse link suitable for 32 amps disconnector fuse unit, size A1L, conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST34529 or its compatible to Havells/Standard/Legrand/Schneider . |
14 | Supplying & fixing ofLED indicator 16 mm surface mounted low power consumption, surge & low voltage glow protection cat no SIL, in the yellow and Blue colours, L&T make, including connections with 0.75 sqmm FRLS single copper conductor cable etc. as reqd. |